Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Acceleration of Glass Alteration Rates Induced by Zeolite Seeds at Controlled pH

As the glass-water reaction proceeds, certain glass compositions undergo a delayed acceleration in the alteration rate – a phenomenon that is commonly referred to as Stage III behavior – which generally coincides with zeolite formation. However, studying Stage III in the laboratory is difficult because the time scale required to observe Stage III behavior can vary from months to several years, and the solution conditions that initiate this acceleration remain poorly understood. Consequently, the development of a corrosion test method capable of quantifying Stage III rates in a timely manner would be of great benefit to both the scientific community and policy makers concerned with nuclear waste disposal. In this work, we induced and measured the acceleration in the corrosion rate of the AFCI glass by seeding static corrosion tests with zeolite Na-P2 at fixed pH90°C values ranging from 9.5 to 11.5. The induced Stage III rates increased linearly with increasing pH and were measured to be between the forward and residual rates of AFCI. Tests designed to compare induced Stage III rates obtained for different seeding times showed that the induced Stage III rates were faster in the absence of an alteration layer. In summary, the use of the seeded test method allows for a conservative quantification of Stage III rates in a relatively short, one-month time period.

Neeway, James J.↗

Accelerating GNNs on GPU Sparse Tensor Cores through N:M Sparsity-Oriented Graph Reordering

Recent advancements in GPU hardware support have introduced the capability to leverage N:M sparse patterns for substantial performance gains. Graphs in Graph Neural Networks (GNNs) are typically sparse, but the sparsity is often irregular, not conforming to such sparse patterns. In this paper, we propose a novel graph reordering algorithm, the first of its kind, to reshape irregular graph data into the N:M structured sparse pattern at the tile level, allowing linear-algebra-based graph operations in GNNs to benefit from the N:M sparse hardware. The optimization is lossless, maintaining the accuracy of GNN. It can remove 98-100\% violations of the N:M sparse patterns at the vector level, and increase the proportion of conforming graphs in SuiteSparse collection from 5-9\% to 88.7-93.5\%. On A100 GPUs, the optimization accelerates Sparse Matrix Matrix (SpMM) by up to 43X (2.3X -- 7.5X on average) and speeds up the key graph operations in GNNs on real graphs by as much as 8.6X (3.5X on average).

artificial intelligence, graph neural networks↗

Impact Report: Quantum Systems Accelerator

The Quantum Systems Accelerator (QSA) is a U.S. National Quantum Information Science Research Center established in August 2020 and funded by the Department of Energy (DOE) Office of Science. QSA is composed of 15 partner institutions— universities and national laboratories—bringing together pioneers of many of today’s unique quantum information science (QIS) and engineering capabilities. Led by Lawrence Berkeley National Laboratory (Berkeley Lab), with Sandia National Laboratories (Sandia Labs) as the lead partner, 250+ QSA researchers are catalyzing U.S. leadership in a fast-growing field that seeks solutions to the Nation’s and the world’s most pressing problems by harnessing the laws of quantum mechanics.

97 MATHEMATICS AND COMPUTING↗

Influence of the ambient acceleration field upon acute acceleration tolerance in chickens

The paper measured the acceleration tolerance of domestic fowl (Rhode Island Red cocks), acutely exposed to a 6 Gz field, as the time over which a normal heart rate can be maintained. This period of circulatory adjustment ends abruptly with pronounced bradycardia. For chickens which previously have been physiologically adapted to 2.5 -G field, the acute acceleration tolerance is greatly increased. The influence of the ambient acceleration field on the adjustment of the circulatory system appears to be a general phenomenon.

Smith, A. H.↗

First-order Fermi acceleration in solar flares as a mechanism for the second-step acceleration of prompt protons and relativistic electrons

Solar flare data from June 27, 1980 balloon-based observations were studied in terms of the hard X ray component. A temporal delay of 3 sec was observed for the X ray emissions above 235 keV. The delay occurred relative to the low-energy electrons and indicated a second acceleration stage. An estimation of the acceleration rate of the first-order Fermi process operating in a closed flare loop was found to be in agreement with the resulting data, including the acceleration of both protons and relativistic electrons. Additional support for the first-order Fermi process is noted in the fact that flares generally occur in magnetic loops, a condition which allows energetic particles to continually interact with the upward moving shock fronts. A correlation has also been observed between the delay times and the H-alpha areas, encouraging the interpretation that the delay times are the shock transit times.

Bai, T.↗

The Influence of Passive Acceleration and Exercise+Acceleration on Work Capacity and Orthostasis

The losses of aerobic power and orthostatic tolerance are significant effects of manned C) spaceflight that can negatively impact crew health and safety. Daily acceleration and aerobic training may ameliorate these effects. To determine the influence of passive intermittent +Gz acceleration (PA) training and active acceleration + interval exercise (AE) training on work 0 0 capacity and the acute (1 min) response to 70 deg head-up tilt, 6 men (X-Bar SD: age, 33 +/- 6 y; height, 178.3 +/- 4.6 cm; mass, 86.3 +/- 6.6 kg) participated in two 3-wk training protocols. It was hypothesized that PA and AE training would improve orthostatic tolerance and that the addition of aerobic conditioning, would not alter this effect.

Simonson, S. R.↗

The Awful Truth About Zero-Gravity: Space Acceleration Measurement System; Orbital Acceleration Research Experiment

Earth's gravity holds the Shuttle in orbit, as it does satellites and the Moon. The apparent weightlessness experienced by astronauts and experiments on the Shuttle is a balancing act, the result of free-fall, or continuously falling around Earth. An easy way to visualize what is happening is with a thought experiment that Sir Isaac Newton did in 1686. Newton envisioned a mountain extending above Earth's atmosphere so that friction with the air would be eliminated. He imagined a cannon atop the mountain and aimed parallel to the ground. Firing the cannon propels the cannonball forward. At the same time, Earth's gravity pulls the cannonball down to the surface and eventual impact. Newton visualized using enough powder to just balance gravity so the cannonball would circle the Earth. Like the cannonball, objects orbiting Earth are in continuous free-fall, and it appears that gravity has been eliminated. Yet, that appearance is deceiving. Activities aboard the Shuttle generate a range of accelerations that have effects similar to those of gravity. The crew works and exercises. The main data relay antenna quivers 17 times per second to prevent 'stiction,' where parts stick then release with a jerk. Cooling pumps, air fans, and other systems add vibration. And traces of Earth's atmosphere, even 200 miles up, drag on the Shuttle. While imperceptible to us, these vibrations can have a profound impact on the commercial research and scientific experiments aboard the Shuttle. Measuring these forces is necessary so that researchers and scientists can see what may have affected their experiments when analyzing data. On STS-107 this service is provided by the Space Acceleration Measurement System for Free Flyers (SAMS-FF) and the Orbital Acceleration Research Experiment (OARE). Precision data from these two instruments will help scientists analyze data from their experiments and eliminate outside influences from the phenomena they are studying during the mission.

Source record↗

Anderson acceleration stability in NDA-accelerated k-eigenvalue problems

Anderson acceleration (AA) has been used to improve the stability and convergence rate of multiphysics iterative methods for reactor analysis. Most applications studied assume a tightly converged solution for the different physics problems, and AA is usually applied to state variables like temperature, density, and heat generation rate. In this paper, we study the theoretical performance of AA in NDA-accelerated k-eigenvalue problems. The problems and algorithms studied are simplified from the coupled iteration scheme adopted by MPACT and many other high-fidelity whole-core reactor codes. Compared to previous analyses of AA for these iteration schemes, we study the case with a partially converged neutronics solution and possibly partially converged nonlinear diffusion acceleration (NDA)/coarse mesh finite difference (CMFD) solutions. We observe that the performance of the iteration scheme with AA is very sensitive to the initial guess and is affected by the partially converged CMFD solutions. When the NDA solution is fully converged, using AA cannot achieve the optimal convergence rate in large-sized problems. Conversely, if the NDA solution is partially converged, the iteration scheme with AA can diverge or converge extremely slowly. It is found that the loss of robustness for AA is due to the fact that it is applied to the iterative subspace of state variables rather than the fundamental unknowns of the governing equations. To improve the robustness, the scalar flux should also be considered in the implementation of AA. After considering the residuals of flux, we observe that the stability is regardless of the partial convergence of NDA solutions. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Extended Accelerated Stress Testing (EAST) of Glass/Glass, Glass/Backsheet and Glass/Transparent Backsheet PV Modules: Influence of EVA and POE Encapsulants: Preprint

This paper presents the indoor extended accelerated stress testing (EAST) results of glass/glass (GG), glass/backsheet (GB) and glass/transparent backsheet (GT) modules having identical cells and two different encapsulant types, ethyl-vinyl-acetate (EVA) and polyolefin-elastomer (POE). Six 4-cell modules having the above-mentioned construction combinations were subjected to extended ultraviolet (UV; 600 kWh/m2), damp-heat (DH; 2000 hours) and thermal-cycling (TC; 600 cycles) tests. The post-stress UV fluorescent imaging, electroluminescent imaging, reflectance spectrophotometry and colorimetry results indicated that the grid finger degradation and encapsulant browning are slightly higher in the GG modules compared to the GB modules. The post-stress IV test results indicated, in general, that the GG/EVA modules tend to perform inferior to the GG/POE modules with the EAST evaluation.

EVA↗

A 100-kW 1300-MHz Magnetron With Amplitude and Phase Control for Accelerators

Calabazas Creek Research, Inc. (CCR), in collaboration with Fermilab and Communications and Power Industries, LLC (CPI), developed a 100-kW peak, 10-kW average, 1300-MHz, magnetron-based, RF system with amplitude and phase control for driving accelerators. Phase locking was achieved using an approach originated at Fermilab that uses phase modulation of the locking signal to control the amplitude and phase into a superconducting cavity on a fast time scale. Experimental results, including demonstration of phase locking and amplitude control, are reported.

43 PARTICLE ACCELERATORS↗

Determination of CO 2 capture during accelerated carbonation of engineered cementitious composite pastes by thermogravimetry

The concerns about greenhouse gas emissions have triggered investigations among the scientific community. The accelerated carbonation curing has been used as a tool to capture CO 2 at early stages of cement-based material fabrication. In a previous study, the authors quantified the amount of CO 2 captured in portland cement pastes by thermal analysis, at high relative humidity precure conditions. In the present work, the authors quantified the amount of CO 2 captured in binary pastes derived from engineered cementitious composites (ECC), a family of composites worldwide used, whose one of their features is the precure at low relative humidity conditions. Two types of ECC pastes (1.2 and 2.2) were submitted to 4 h and 24 h of accelerated carbonation after 24 h of initial hydration. Using thermogravimetry and derivative thermogravimetry, the amounts of captured CO 2 and respective carbonation degrees were quantified. Furthermore, the results showed that ECC paste 1.2 presented the highest values of captured CO 2 and carbonation degree, considering all reactive components. In contrast, ECC paste 2.2 presented the highest values of these two parameters, when considering only portland cement as reactive component. For both pastes, the hydration degrees of the carbonated samples were higher than those of the non-carbonated references, indicating that in the used operating conditions, carbonation enhances ECC paste hydration.

42 ENGINEERING↗

Toxicokinetics of benzo[a]pyrene in humans: Extensive metabolism as determined by UPLC-accelerator mass spectrometry following oral micro-dosing

Benzo[a]pyrene (BaP), produces tumors of skin, lung, liver, kidney and stomach in animals, enhances lung cancer in epidemiological studies and is a known human carcinogen. The EPA cancer slope risk factor for oral BaP exposure is 1 per mg/kg-day. The remarkable sensitivity (attomole 14C; precision 0.5-2% in biological samples) of accelerator mass spectrometry (AMS) makes possible [14C]-BaP dosing of humans with de minimus risk. A micro-dose of 46 ng (5 nCi), was given in 3 separate cycles to 5 human volunteers with a minimum 2 weeks between dosing. Blood was collected over 72 hours and BaP and BaP metabolites ([14C]-BaPeq) measured using AMS. [14C]-BaPeq appeared in plasma with an average Tmax of 75 minutes and Cmax 116-326 fM (29-82 fg/mL). Non-compartmental half-lives in plasma ranged from 30.7-114.2 hours and area under the curve values (AUC0-72 hr) 649-2060 fg x hr x mL-1. A two compartmental model yielded first-order rate constants (Ka, K12, K21, Kela and Kelß) of 0.92, 0.49, 0.12, 0.05 and 0.01 fg/hr, respectively. The T1/2a and T1/2ß were 1.14 and 89 hours, respectively. The actual interval between dosing was 20-420 days with no impact on a low intra-individual variation. No covalent [14C]-BaPeq-DNA adducts from peripheral blood mononuclear cells (PBMCs) were detected (LLOD of 10 fg [14C]-BaPeq adducts/mg DNA) 12-72 hours post-dosing negating the use of this cancer biomarker in risk assessment. We assert that the most relevant model for humans is humans. AMS and micro-dosing could be used to enhance the accuracy of pharmacokinetics and potentially risk assessments.

pharmacokinetcs, Polycyclic aromatic hydrocarbons↗

First Simultaneous Acceleration of Multiple Charge States of Heavy Ion Beams in a Large-Scale Superconducting Linear Accelerator

Experimental studies of the simultaneous acceleration of three-charge-state 129 Xe 49+,50+,51+ beam from 17 to 180 MeV/nucleon in a superconducting linear accelerator are presented. The beam parameters for each individual- and multiple-charge-state beam were measured and compared with the particle tracking simulations. Detailed measurements were performed to characterize the multiple-charge-state beam’s recombination after a second-order achromat and isopath 180° bending system. As a result of the recombination of three charge states in the six-dimensional phase space, the xenon beam intensity was increased by 2.5-fold compared to the single-charge-state beam. Lastly, the results presented in the Letter fully validate the possibility to produce and utilize high-quality multiple-charge-state heavy-ion beams in a large-scale superconducting linac to increase the available beam power on an isotope production target.

43 PARTICLE ACCELERATORS↗

Inverted Geometry Ceramic Insulators in High Voltage DC Electron Guns for Accelerators

A direct current (dc) high voltage photo-emission electron gun operating at 130 kV is utilized at the Jefferson Lab (JLab) Continuous Electron Beam Accelerator Facility to generate spin-polarized electrons for nuclear physics experiments. Over the past decade, JLab has tested and implemented inverted-geometry ceramic insulators in photoguns, connecting the cathode electrode in vacuum to the high voltage power supply using commercial high voltage cables. This contribution reports on tests performed up to 375 kV dc, implementation of inverted insulators in a 300 kV dc photogun generating magnetized electron beams, and describes plans to develop a reliable insulator-cable connector for applying 500 kV dc to a future polarized beam photogun operating reliably and without field emission at 350 kV.

Hernandez-Garcia, C.↗