Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Instrument automatically selects peak acceleration signal from several accelerometers

Solid state circuit selects the highest of several ac accelerometer signals and gates this signal to an output amplifier, preserving all the frequency information in the peak signal. If the amplitudes of the accelerometer signals change with time, the circuit will continually switch to the highest signal, rejecting the smaller signals.

Chapman, C. P.↗

Miniature capacitive accelerometer is especially applicable to telemetry

Capacitive accelerometer design enables the construction of highly miniaturized instruments having full-scale ranges from 1 g to several hundred g. This accelerometer is applicable to telemetry and can be tailored to cover any of a large number of acceleration ranges and frequency responses.

Coon, G. W.↗

Low level accelerometer test methods are investigated

Problems associated with testing accelerometers to an accuracy where the standard error is less than .0000001 g are centered around the elimination of uncertainties in the acceleration input to the accelerometer. By placing a test rig in free fall, the uncertainty in the earths gravity field can be eliminated.

Nelson, R. H., Jr.↗

Low G accelerometer testing

Eight different types of low-g accelerometer tests are covered on the Bell miniature electrostatically suspended accelerometer (MESA) which is known to be sensitive to less than 10 to the minus 7th power earth's gravity. These tests include a mass attracting scheme, Leitz dividing head, Wild theodolite, precision gage blocks, precision tiltmeters, Hilger Watts autocollimator, Razdow Mark 2 autocollimator, and laser interferometer measuring system. Each test is described and a comparison of the results is presented. The output of the MESA was as linear and consistent as any of the available devices were capable of measuring. Although the extent of agreement varied with the test equipment used, it can only be concluded that the indicated errors were attributable to the test equipment coupled with the environmental conditions.

Vaughan, M. S.↗

Gyro and accelerometer failure detection and identification in redundant sensor systems

Algorithms for failure detection and identification for redundant noncolinear arrays of single degree of freedom gyros and accelerometers are described. These algorithms are optimum in the sense that detection occurs as soon as it is no longer possible to account for the instrument outputs as the outputs of good instruments operating within their noise tolerances, and identification occurs as soon as it is true that only a particular instrument failure could account for the actual instrument outputs within the noise tolerance of good instruments. An estimation algorithm is described which minimizes the maximum possible estimation error magnitude for the given set of instrument outputs. Monte Carlo simulation results are presented for the application of the algorithms to an inertial reference unit consisting of six gyros and six accelerometers in two alternate configurations.

Potter, J. E.↗

Gyro and accelerometer failure detection and identification in redundant sensor systems.

An algorithm for failure detection and identification for redundant non-orthogonal arrays of single degree of freedom gyros and accelerometers is described which is optimum in the sense that detection occurs as soon as it is no longer possible to account for the instrument outputs as the outputs of good instruments operating within their noise tolerances, and identification occurs as soon as it is true that only a particular instrument failure could account for the actual instrument outputs within the noise tolerance of good instruments. An estimation algorithm is described which minimizes the maximum possible error magnitude for the given set of instrument outputs. Monte Carlo simulation results are presented for the application of the algorithms to an inertial reference unit consisting of six gyros and six accelerometers in two alternate configurations.

Potter, J. E.↗

Minimax failure detection and identification in redundant gyro and accelerometer systems.

Minimax algorithms for failure detection and identification for redundant noncolinear arrays of single-degree-of-freedom gyros and accelerometers are described. These algorithms are optimum in the sense that detection occurs as soon as it is no longer possible to account for the instrument outputs as the outputs of good instruments operating within their noise tolerances, and identification occurs as soon as it is true that only a particular instrument failure could account for the actual instrument outputs within the noise tolerance of good instruments. An estimation algorithm is described which minimizes the maximum possible estimation error magnitude for the given set of instrument outputs. Monte Carlo simulation results are presented for the application of the algorithms to an inertial reference unit consisting of six gyros and six accelerometers in two alternate configurations.

Potter, J. E.↗

Contributions to the problem of piezoelectric accelerometer calibration

After discussing the principal calibration methods for piezoelectric accelerometers, an experimental setup for accelerometer calibration by the reciprocity method is described It is shown how the use of a lock-in voltmeter eliminates errors due to viscous damping and electrical loading.

Jakab, I.↗

High-resolution width-modulated pulse rebalance electronics for strapdown gyroscopes and accelerometers

Three different rebalance electronic loops were designed, implemented, and evaluated. The loops were width-modulated binary types using a 614.4 kHz keying signal; they were developed to accommodate the following three inertial sensors with the indicated resolution values: (1) Kearfott 2412 accelerometer - resolution = 260 micro-g/data pulse, (2) Honeywell GG334 gyroscope - resolution = 3.9 milli-arc-sec/data pulse, (3) Kearfott 2401-009 accelerometer - resolution = 144 milli-g/data pulse. Design theory, details of the design implementation, and experimental results for each loop are presented.

Kennedy, E. J.↗

Accelerometer telemetry system

An accelerometer telemetry system incorporated in a finger ring is used for monitoring the motor responses of a subject. The system includes an accelerometer, battery, and transmitter and provides information to a remote receiver regarding hand movements of a subject wearing the ring, without the constraints of wires. Possible applications include the detection of fatigue from the hand movements of the wearer.

Konigsberg, E.↗

Shuttle entry trajectory reconstruction using inflight accelerometer and gyro measurements

An error analysis has been made of a Shuttle postflight entry trajectory reconstruction process to obtain trajectory state estimation errors and to assess the impact of these errors on Shuttle aerodynamic force coefficient extraction. In this analysis, the entry trajectory is assumed to be reconstructed via numerical integration of onboard accelerometer and gyro measurements and constrained to satisfy ground-based radio tracking. The trajectory state estimation errors are calculated using a Kalman-Schmidt sequential filter assuming various measurement error models and combinations of ground-based tracking. The resultant trajectory estimation errors are analyzed in a simplified perturbation process to establish the accuracy to which postflight aerodynamic force coefficients can be determined. Results are presented which show that the principal error sources affecting the trajectory reconstruction and thus the force coefficient extraction, assuming perfect atmospheric density knowledge, are the accelerometer and gyro resolution, acceleration-sensitive gyro drifts, and the alignment uncertainties associated with integration on the Shuttle.

Compton, H. R.↗

Six-Axis Superconducting Accelerometer

Sensitivity and short-term stability high. Design combines superconductivity and magnetic levitation to achieve linear-acceleration sensitivity greater than conventional linear accelerometers, and short-term angular stability better than conventional gyroscopes. Improved accelerometer used to increase precision in inertial navigation and surveying, as sensitive multiple-axis seismic sensor, as component of tensor gravity gradiometer, or to sense accelerations of stabilized platforms or spacecraft.

Paik, Ho Jung↗

Rarefied aerodynamics and upper atmospheric flight results from the Orbiter High Resolution Accelerometer Package experiment

Data from the High Resolution Accelerometer Package (HiRAP) experiment on the Space Shuttle Orbiter have been analyzed for 10 flights to produce lift-drag (L/D) ratios in the free molecule, transition, and continuum flow flight regimes. Freestream density is also obtained in the altitude range from 60 km to 160 km using an aerodynamic model based upon earlier flight analysis of accelerometer data. The results of the L/D analysis of the latest four flights have been compared with the aerodynamic model developed from the first six HiRAP missions. The new data agree with the established flight-derived model, thereby validating earlier analysis. However, the arithmetic mean of the 10 flight-derived L/D values in the free molecular flow regime is 0.053 (+ or - 0.1) as compared to the initial value of 0.10 (+ or - 0.3), determined from STS-6. Updates to the Orbiter aerodynamic model values and calibration factors have been incorporated into the density calculations for all 10 flights to provide realistic absolute density. The derived density altitude profiles, which have been normalized to the U.S. Standard Atmosphere 1976, are characterized by a large amplitude wave pattern relative to the standard as seen in the initial flight analysis.

Blanchard, R. C.↗

Dual-Cantilever-Beam Accelerometer

Sensitivity to velocity changes along beam axis reduced. Weighted-end cantilever beams of accelerometer deflected equally by acceleration in y direction. When acceleration to right as well as up or down, right beam deflected more, while left beam deflected less. Bridge circuit averages outputs of strain gauges measuring deflections, so cross-axis sensitivity of accelerometer reduced. New device simple and inexpensive.

Reynolds, Emmitt A.↗

Shuttle high resolution accelerometer package experiment results - Atmospheric density measurements between 60-160 km

Indirect or inferred values of atmospheric density encountered by the Shuttle Orbiter during reentry have been calculated from acceleration measurements made by the High Resolution Accelerometer Package (HiRAP) and the Orbiter Inertial Measurement Unit (IMU) liner accelerometers. The atmospheric density data developed from this study represent a significant gain with respect to the body of data collected to date by various techniques in the altitude range of 60 to 160 km. The data are unique in that they cover a very wide horizontal range during each flight and provide insight into the actual density variations encountered along the reentry flight path. The data, which were collected over about 3 years, are also characterized by variations in solar activity, geomagnetic index, and local solar time. Comparison of the flight-derived densities with various atmospheric models have been made, and analyses have attempted to characterize the data and to show correlation with selected physical variables.

Blanchard, R. C.↗

Power flow in a beam using a 5-accelerometer probe

A method to determine structure-borne power flow is examined which uses central finite differences to approximate the field variables required to calculate the shear and bending components of flexural vibration. An experimental study using a beam driven by a shaker was performed with the aim of comparing estimates using this proposed five-accelerometer method and the conventional two-accelerometer, free-field method. The advantages and disadvantages of the new method are pointed out.

Downing, J. Micah↗

The measurement and control of helicopter blade modal response using blade-mounted accelerometers

The measurement of helicopter blade flapping, bending, and lag modal acceleration and displacement response using blade-mounted accelerometers is described. It is shown that knowledge of the blade mode shapes is sufficient to permit separation of the modal contributions to the accelerometer signals using matrix inversion. The application of the Mckillip (1985) filter to the identification of modal rate response is described. Finally, the design of flapping, bending, and lag mode controllers utilizing the conventional mesh plate is presented. The measurement technique is illustrated using flight test results obtained using a Black Hawk helicopter.

Ham, Norman D.↗