62 records · Page 4

Environmental Contributions to Proton Sharing in Protein Low-Barrier Hydrogen Bonds

Hydrogen bonds (H-bonds) are central to biomolecular structure and dynamics. Although H-bonds are typically characterized by well-defined proton positions, proton delocalization has been proposed to play a role in facilitating enzyme catalysis and allostery in some systems. Experimentally locating protons is difficult, hampering the study of proton mobility in H-bonds. We used neutron crystallography, atomic resolution X-ray bond length analysis, and large quantum mechanics/molecular mechanics-Born–Oppenheimer molecular dynamics (QM/MM-BOMD) simulations to comprehensively characterize the shared proton/deuteron in a Glu–Asp low-barrier hydrogen bond (LBHB) in the bacterial protein YajL that is a conventional H-bond in the homologous disease-associated human protein DJ-1. X-ray bond length analysis of protiated and perdeuterated DJ-1 and YajL shows no significant effect of deuteron substitution on these carboxylic acid-carboxylate H-bonds but does reveal an effect at the active site glutamic acid near a cysteine thiolate. Residues in an H-bonded network that might favor LBHB formation in YajL were interrogated by the mutation of homologous residues in DJ-1. A distal DJ-1 substitution increases proton delocalization in the Glu–Asp H-bond, demonstrating that mutations within extended H-bond networks can modulate proton transfer barriers in carboxylic acid-carboxylate H-bonds. In addition, proton mobility in the H-bond is correlated with dimer-spanning motions in the QM/MM-BOMD simulations of YajL and DJ-1. Our results show that proton delocalization can be tuned using combined bioinformatic, structural, and computational information, opening the possibility of using engineered proton delocalization as a probe of H-bonding environments and as a tool to test hypotheses about LBHB function.

Lin, Jiusheng [University of Nebraska, Lincoln, NE↗

Segregation behavior and phase instability of Eurofer97 after neutron irradiation to 72 dpa

Here, a reduced activation ferritic/martensitic steel, Eurofer97, was neutron irradiated in the vicinity of 300 °C in the High Flux Isotope Reactor (HFIR) up to 72 dpa. Advanced analytical scanning transmission electron microscopy and conventional transmission electron microscopy were applied to investigate the radiation-induced segregation and phase instability behavior after neutron irradiation. Amorphization was observed in M 23 C 6 carbides. Cr-rich clusters were seen within the matrix, near the lath boundaries and close to the M 23 C 6 carbides. Cr enrichment and Fe depletion were detected at both prior austenite grain boundaries and lath boundaries, despite different segregation magnitude. In addition, the enrichment of Ni, the depletion of V, and tiny cavities (presumably helium bubbles) are also found at lath boundaries. This work interrogates the evolution of microstructures after neutron irradiation, which provides detailed understanding on the microstructural aspects controlling the mechanical integrity of Eurofer97 under high-dose neutron damage.

36 MATERIALS SCIENCE↗

PING Gamma Ray and Neutron Measurements of a Meter-Sized Carbonaceous Asteroid Analog

Determining the elemental composition of carbonaceous (spectral type C) asteroids is still one of the basic problems when studying these objects. The only main source of elemental composition information for asteroids is from their optical, NIR and IR properties, which include their spectral reflectance characteristics, albedo, polarization, and the comparison of optical spectroscopy with meteorite groups corresponding to asteroids of every spectral type. Unfortunately, these sources reflect observations from widely contrasting spatial scales that presently yield a void in the continuum of microscopic and macroscopic evidence, a lack of in situ measurement confirmation, and require deeper sensing techniques to discern the nature of these asteroids. The Probing In situ with Neutrons and Gamma rays (PING) instrument is ideally suited to address this problem because it can be used to determine the bulk elemental composition, H and C content, the average atomic weight and density of the surface and subsurface layers of C-type asteroids, and can provide measurements used to determine the difference between and distinguish between different types of asteroids. We are currently developing the PING instrument that combines gamma ray and neutron detectors with a 14 Me V pulsed neutron generator to determine the in-situ bulk elemental abundances and geochemistry of C-type asteroids with a spatial resolution of 1 m down to depths of tens of cm to 1 m. One aspect of the current work includes experimentally testing and optimizing PING on a known meter-sized Columbia River basalt C-type asteroid analog sample that has a similar composition and the same neutron response as that of a C-type asteroid. An important part of this effort focuses on utilizing timing measurements to isolate gamma rays produced by neutron inelastic scattering, neutron capture and delayed activation processes. Separating the gamma ray spectra by nuclear processes results in higher precision and sensitivity elemental composition measurements. Using gated data acquisition techniques allows for the unambiguous identification of gamma ray lines from different isotopes and nuclear processes, especially in situations when limited detector resolution results in overlapping gamma ray lines that cannot be individually resolved. In this paper, we will present the PING basalt layering experimental data, taken at the test facility at NASA Goddard Space Flight Center using the time tagged event-by-event data analysis technique, compared to our MCNPX computer simulation results for the C-type asteroid and basalt layering simulant models. Comparison of these data will show the advantages, validity, and measurement sensitivity of PING's nuclear interrogation methods to obtain more precise and sensitive in situ bulk elemental composition and density measurements of the subsurface of asteroids.

Bodnarik, J.↗

Configuration and impurity quantification of AmLi sources using radiography and gamma spectroscopy

This paper presents the non-destructive assay of two AmLi sources used for detector characterization and active interrogation at PNNL, identified as MRC-101 and MRC-103. First, a detailed description of the internal configuration of 2724-BT encapsulated MRC sources is established. X-ray radiographs of the AmLi sources are reported for the first time to verify the dimensions and orientation of the encapsulation. Notably, a density variation was observed as a contrast change across the height of the source cavities. Contrary to commonly made assumptions in literature, it is indirectly observed that the AmLi source/target material only occupies a portion of the source cavity. The intensity of the prompt gamma-rays resulting from the inelastic scatter of alpha particles on 7Li was used to calculate the mass ratios of LiH:AmO2. The gamma-ray spectra revealed the presence of numerous impurities in both source and target material (243Am, 237Np, 154Eu, 23Na, and 9Be). Neutron-gamma production ratios were applied to the intensity of the Doppler-broadened peaks from alpha-induced reactions with 7Li, 9Be, and 23Na to calculate neutron rates for both sources. A neutron/alpha production yield (derived in this work) was then related to the atomic concentration of these isotopes to find the approximate masses within each source. Ultimately, the AmLi source density was estimated with prompt gamma analysis based on partial source volumes as 0.45±0.08 g/cm^3.

DTRA, AmLi, neutron↗

Multi-modal dynamic radiography using short-pulse laser-generated probe beams

Radiography is an important tool for the interrogation of dynamic experiments in the fields of dynamic properties of materials, and in condensed matter, high explosive, and high-energy-density physics. Multi-modal radiography advances the hypothesis that combining the information delivered by multiple radiographic modalities can lead to more constrained (improved) “reconstruction” of the scene than can be obtained from a single probe. We identify four modalities: multi-probe, time sequence, multi-view, and multi-messenger. Multi-probe radiography is a promising candidate for a next-generation dynamic radiographic facility. High-energy X-rays are the most frequently used probe for dynamic radiography, although recent developments show the utility of proton (pRad), electron (eRad), and neutron probe beams. Because each probing species interacts with material in the radiographic scene through quantitatively different mechanisms, each returns independent information about the scene, which can add extra constraints to the reconstruction process. How to conduct detailed, quantitative “co-analysis” of multiple data streams remains an area of active research. Multi-beam, short-pulse, laser-generated probes offer sufficient dose, an appropriate spectrum, and appropriate spatio-temporal resolution to produce high-quality dynamic radiographs. This paper reports on technology development to advance the state of the art of multi-modal/multi-probe radiography and the pursuit of both deterministic and inferential (AI/ML assisted) co-analysis methodologies to produce more constrained reconstructions from multi-modal data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Understanding and controlling water-organic co-transport in amorphous microporous materials

The transport of molecules in microporous material is a significant and active area of research in separation applications. The movement of vapor/liquid molecules in a high-loading condition in microporous spaces is especially challenging to interrogate. This project aims to understand and control the transport of complex water and organic solvent mixtures in varying structures of microporous carbon molecular sieve (CMS) and activated carbon membranes. Modeling of transport behavior in such carbonaceous samples using computational modeling is difficult due to their amorphous structure. Therefore, this research intends to study the transport mechanism of water-organic mixtures by experimentally revealing fundamental transport properties, such as guest sorption amounts as well as diffusion and permeation rates. Considering the different size and guest-host affinity of water and organic solvent molecules, the objective of this research is to understand the structural conditions within the ultramicropores and micropores that generate different types of molecular transport and selection mechanisms within such complex systems. Carbonaceous materials are developed using tailored pyrolysis techniques to pyrolyze polymeric precursors, including polyvinylidene chloride (PVDC),polyvinylidene fluoride (PVDF), polymer of intrinsic microporosity (PIM) -1, and fully aromatic polyamide. The initial stage of the research will focus on the microscopic diffusion and sorption studies of pure component water, xylene isomers, and n,n- dimethylformamide within various carbons. Additional structural investigation on CMS, such as gas physisorption and neutron scattering studies, will be executed to gain deeper insight into these structure-transport relationships. Scanning electron microscopy and X-ray photoelectron microscopy are also used to further characterize these materials. The research will progress to probe mutual diffusion of complex water-organic mixtures within various CMS microstructures. Competitive sorption and permeation studies of the binary mixtures in different microstructural CMS will be followed. The obtained binary mixture transport parameters were used to predict binary water-organic mixtures transport.

36 MATERIALS SCIENCE↗

Nondestructive measurements of residual 235 U mass of Israeli Research Reactor-1 fuel using the Advanced Experimental Fuel Counter

In 2018, a measurement campaign took place with participants from Los Alamos National Laboratory (LANL), the Nuclear Research Centre-Negev (NRCN) and Soreq Nuclear Research Center (SNRC) at the Israeli Research Reactor-1 (IRR-1) in which 14 of the reactor’s used fuel assemblies (FAs) with varied amount of depletion were measured with the nondestructive assay instrument Advanced Experimental Fuel Counter (AEFC). Designed for safeguards purposes, the AEFC measures both neutrons emitted from the FA (passive neutrons) and fission neutrons induced by an external neutron source (in this experiment, 252 Cf). Signals recorded with the AEFC include total neutron count rates (Singles), time-correlated neutron count rates (Doubles), and total gamma-ray count rates. The 235 U content of the FAs was previously assessed by two independent methods: (1) measurement of the transparency of the FA to low-energy gamma rays from an activated rhenium source (rhenium gamma transmission, or the RGT method) and (2) calculation of the 30-year burnup history of the core using detailed three-dimensional Monte-Carlo core depletion calculations. The results from the FAs that had been measured via the RGT method were used to construct the calibration curves, which translate the AEFC count rates to 235 U mass. Then, the calibration was evaluated using AEFC measurements of six additional FAs that were not measured via the RGT method. From the results, it was determined the Doubles calibration curve was more reliable than that of the Singles and follows a simple second-order polynomial fit for the whole range of residual 235 U mass content, albeit with larger statistical uncertainty. Detailed uncertainties quantification was conducted for both the AEFC Singles and Doubles. This includes the analysis of statistical uncertainties, calibration uncertainty, and random uncertainties due to the sensitivity of the AEFC to several sources of uncertainty, namely the FA position, FA orientation, interrogation source position, and ambient pool temperature. Finally, an overall total uncertainty of 6 g of 235 U is estimated for the Singles and Doubles, which is mainly due to calibration uncertainty (for the Singles) and statistical uncertainty (for the Doubles), and which constitutes 3%–6% of the 235 U total mass in the FAs, depending on their level of depletion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Experimental Feasibility Study on Applying Neutron Tomography to Encapsulated Spent Nuclear Fuel - 20050

Visual inspection makes easier to ensure the integrity and safety of spent nuclear fuel (SNF) than any classical techniques. Various classical techniques have been applied but there are no reliable methods to qualitatively and quantitatively verify spent fuel in dry storage. Thus, the present authors have developed the prototype safeguards apparatus for dry storage employing the array of He-4 gas scintillation detectors (S670E, Arktis Radiation Detectors Ltd., Switzerland), newly designed to simultaneously measure thermal and fast neutrons without any moderators. The S670E detector has a cylindrical shape with a diameter of 52 mm and active length of 600 mm (total length: 875 mm). The detector is filled by He-4 gas with an approximate pressure of 180 bar for fast neutron detection, and its inner wall is coated by Li-6 for thermal neutron detection. The scintillation lights generated via Li-6 nuclear reaction and elastic scattering are collected by 24 SiPMs linearly paired at the center of the detector. The detector delivers a TTL (Transistor-Transistor Logic) output for pulse readout and UART (Universal Asynchronous Receiver Transmitter) for device control. In order to assess feasibility of the apparatus, an experimental system has been designed, built, and optimized via computational studies. Cf-252 neutron sources and linearly arrayed detectors, working as a single detector, were occupied for this study due to the difficulties in working with SNF. The laboratory scale cask (diameter: 0.67 m, height: 1.5 m), minimized by a factor of 10 compared to the actual thickness of a commercial TN-32 cask, was also manufactured. The detector array was designed to rotate the lab-scale cask and obtain 36 image profiles at every 10 degrees. All profiles were aligned in single frame image called a sinogram, and the cross-sectional image was then fabricated by the inverse radon transform algorithm. These experiments have been repeated with different configurations and numbers of sources. Some gamma-ray sources were also measured with neutron sources in order to distinguish between neutron and gamma-ray pulses. Basically, a He-4 detector is designed to run on Linux OS so it is difficult to directly apply to Windows-based equipment widely used in S. Korea. Therefore, a new data acquisition board working on Windows OS was designed and built. The board mainly consists of FPGA (Field Programmable Gate Array) and SoC (System on Chip) for TTL pulse readout, sorting measured data, and transferring data to a user interface. In conclusion, the tomographic system at lab-scale has shown considerable potential to detect a partial or gross defect of encapsulated assemblies in dry storage. Next steps of this study will be to 1) repeatedly carry out experiments to demonstrate scientific reliability and validity, and 2) numerically integrate signals with weight factors to enhance the image quality since the suggested system based on passive interrogation method requires longer measurement time. Finally, the system will apply to a commercial dry storage phased out soon in S. Korea. (authors)

07 ISOTOPE AND RADIATION SOURCES↗