Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Test Reactor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Monitoring Methods for Early Detection of Inadvertent Fission Product Release at the Advanced Test Reactor

Isotope effluent data obtained during three instances of experiment failures at the Advanced Test Reactor (ATR) are analyzed to provide an overview of the methods used to detect initial signs of unintended fission product release. The data is contextualized with the operational experience, including means of identification and subsequent mitigation strategies, gained during these events. General trends as well as variations in isotopic behavior between the three failures are explored. Background on the Real Time Monitor, a High Purity Germanium detector, and other fission product monitoring systems utilized at the Advanced Test Reactor is also provided. The presented analysis was used to establish administrative action levels which are currently utilized by ATR for early detection of experiment fission product release. Early identification provides time to make programmatic decisions before approaching safety and environmental limits.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Improving to the neutron fluence rate monitor measurement system at the Advanced Test Reactor

The existing fluence monitor wire scanning system at the Advanced Test Reactor (ATR) was designed and installed for use in the Engineering Test Reactor (ETR) when it began operation in 1958. The wire scanner was operated in ETR for over 20 years until ATR began operation, when it was moved to the ATR west canal area in 1971 and subsequently moved to the west canal in 2006 where it presently resides. With a continued service life of 65 years the system is well beyond the typical design life of 20 years for these types of systems. The need to update the data acquisition and control system was identified, and the benefits of replacing the existing sodium iodide (NaI) detector with an electronically cooled high-purity germanium (HPGe) detector are discussed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

PLANNING FOR NUCLEAR TESTING AFTER CORE INTERNALS CHANGEOUT #6 IN THE ADVANCED TEST REACTOR

A series of physics tests were planned for the Advanced Test Reactor (ATR) after the sixth Core Internals Changeout (CIC) in 2021. These tests verify nuclear characteristics of the new reflector and shim mechanisms and are validation cases for core models. This work describes planning for these tests and compares the physics tests with those performed previously in ATR. This work also identifies unique characteristics of ATR that result in the need for unique tests.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Impact of High-Reactivity Advanced Test Reactor Experiments on Photon Heating in Nearby Experiment Locations

The Advanced Test Reactor’s (ATR’s) distinctive ability to provide a wide range of irradiation conditions is attractive for programs pursuing fuel qualification experiments. These potentially high-fuel-load experiments are a relatively new development and produce unexplored effects on nearby experiments. Here, this paper explores how photon heating of such an experiment may affect other nearby experiment programs, ultimately serving to better inform decisions regarding experiment design and risks to programmatic goals. The MC21 (Monte Carlo for the 21st Century) code is used to model and study how gamma heat generation rates and axial effects impact different ATR positions. The results reveal that the proximity of a given experiment’s position to the high-fuel-load one can significantly alter that experiment’s expected axial profile.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Validation of High-Fidelity Reactor Physics Models for Support of the KJRR Experimental Campaign in the Advanced Test Reactor

The Korea Atomic Energy Research Institute is currently in the process of qualifying a Low-Enriched Uranium fuel element design for the new Ki-Jang Research Reactor (KJRR). As part of this effort, a prototype KJRR fuel element was irradiated for several operating cycles in the Northeast Flux Trap of the Advanced Test Reactor (ATR) at the Idaho National Laboratory. The KJRR fuel element contained a very large quantity of fissile material (618g 235U) in comparison with historical ATR experiment standards (<1g 235U), and its presence in the ATR flux trap was expected to create a neutronic configuration that would be well outside of the approved validation envelope for the reactor physics analysis methods used to support ATR operations. Accordingly it was necessary, prior to high-power irradiation of the KJRR fuel element in the ATR, to conduct an extensive set of new low-power physics measurements with the KJRR fuel element installed in the ATR Critical Facility (ATRC), a companion facility to the ATR that is located in an immediately adjacent building, sharing the same fuel handling and storage canal. The new measurements had the objective of expanding the validation envelope for the computational reactor physics tools used to support ATR operations and safety analysis to include the planned KJRR irradiation in the ATR and similar experiments that are anticipated in the future. The computational and experimental results demonstrated that the neutronic behavior of the KJRR fuel element in the ATRC is well-understood, both in terms of its general effects on core excess reactivity and fission power distributions, its effects on the calibration of the core lobe power measurement system, as well as in terms of its own internal fission rate distribution and total fission power per unit ATRC core power. Taken as a whole, these results have significantly extended the ATR physics validation envelope, thereby enabling an entire new class of irradiation experiments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improving to the neutron fluence rate monitor measurement system at the Advanced Test Reactor [Poster]

The existing fluence monitor wire scanning system at the Advanced Test Reactor (ATR) was designed and installed for use in the Engineering Test Reactor (ETR) when it began operation in 1958. The wire scanner was operated in ETR for over 20 years until ATR began operation, when it was moved to the ATR west canal area in 1971 and subsequently moved to the west canal in 2006 where it presently resides. With a continued service life of 65 years the system is well beyond the typical design life of 20 years for these types of systems. The need to update the data acquisition and control system was identified, and the benefits of replacing the existing sodium iodide (NaI) detector with an electronically cooled high-purity germanium (HPGe) detector are discussed. The wirescanner system in the ATR canal is utilized after every reactor cycle by the ATR Radiation Measurements Laboratory (RML) to assess the activation of cobalt and nickel dosimeter wires during the cycle. These wires become activated through exposure to thermal and fast neutrons respectively during the irradiation cycle and are highly radioactive upon shutdown. It is for this reason that the wirescanner is used in the ATR canal rather than transporting the dosimeters to another facility. A scoping study was performed to develop a base-line design to ensure that existing capabilities could be replaced with a new system. The new hardware will enable automated measuring of several flux monitor holders without necessitating the removal of the flux wires. In this way, flux wire measurements will be performed with minimal dose to the technicians and will not be limited by canal operations as is presently the case. The new control and acquisition software will be based on commercially available and supported systems that have a wide user-base to provide long-term stability. An electronically cooled HPGe detector will be used to provide high-resolution gamma-ray measurements, an improvement from the low-resolution sodium-iodide detector that is presently deployed. The electronic cooler eliminates the need for liquid nitrogen to cool the detector head. A new collimator has been designed to house the new detector and allow for sufficient counting rates.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A standard capsule design for structural material testing in the Advanced Test Reactor

Nuclear materials testing is commonly completed in various material test and research reactors throughout the world, including the Advanced Test Reactor (ATR), but the current capsule design, analysis, and fabrication process can take years to complete. To decrease the costs and time associated with materials testing, a standard capsule has been designed which houses various specimen geometries and allows irradiation in virtually any ATR test position. The standard capsule features locking end caps which connect and lock together to form the capsule stack, eliminating the need for a basket and maximizing the quantity of specimens which are contained within the capsule. A customizable internal gas gap provides thermal resistance between the specimens and reactor coolant, making specimen temperatures from approximately 370 to 1000 K achievable. The flexibility of the capsule design allows experimenters to choose irradiation positions based off desired neutron flux, with typical fluences per cycle ranging from 8.8x10 19 to 2.3x10 21 n/cm 2 , depending on experiment position. Here this paper presents and discusses the standard capsule design and analysis.

36 MATERIALS SCIENCE↗

Completion of Nuclear Testing after Core Internals Changeout #6 in the Advanced Test Reactor

A series of physics tests were conducted in 2022 for the Advanced Test Reactor (ATR) after the sixth Core Internals Changeout (CIC) in 2021. These tests verify nuclear characteristics of the new reflector and shim mechanisms and are validation cases for core models. This work describes the results of these tests and compares the physics tests with those performed previously in ATR and updates previous work reporting on planning for nuclear testing and on preliminary results of several low-power tests. This work also identifies unique characteristics of ATR that result in the need for unique tests.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

System Upgrades at the Advanced Test Reactor Help Ensure that Nuclear Energy Research Continues at the Idaho National Laboratory

Fully operational in 1967, the Advanced Test Reactor (ATR) is a first-of-its-kind materials test reactor. Located on the Idaho National Laboratory’s desert site, this reactor remains at the forefront of nuclear science, producing extremely high neutron irradiation in a relatively short time span. The Advanced Test Reactor is also the only U.S. reactor that can replicate multiple reactor environments concurrently. The Idaho National Laboratory and the Department of Energy recently invested over 13 million dollars to replace three of ATR’s instrumentation and control systems. The new systems offer the latest software and technology advancements, ensuring the availability of the reactor for future energy research. Engineers and project managers successfully completed the four year project in March while the ATR was in a scheduled maintenance outage. “These new systems represent state-of-the-art monitoring and annunciation capabilities,” said Don Feldman, ATR Station Manager. “They are comparable to systems currently used for advanced reactor designs planned for construction in the U.S. and in operation in some foreign countries.”

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status Report on Efforts to Enhance Instrumentation to Support Advanced Test Reactor Irradiations

The Department of Energy (DOE) designated the Advanced Test Reactor (ATR) as a National Scientific User Facility (NSUF) in April 2007 to support U.S. leadership in nuclear science and technology. By attracting new research users - universities, laboratories, and industry - the ATR NSUF facilitates basic and applied nuclear research and development, further advancing the nation's energy security needs. A key component of the ATR NSUF effort is to prove new in-pile instrumentation techniques that are capable of providing real-time measurements of key parameters during irradiation. To address this need, an assessment of instrumentation available and under-development at other test reactors was completed. Based on this review, recommendations were made with respect to what instrumentation is needed at the ATR; and a strategy was developed for obtaining these sensors. In 2009, a report was issued documenting this program’s strategy and initial progress toward accomplishing program objectives. In 2009, a report was issued documenting this instrumentation development strategy and initial progress toward accomplishing instrumentation development program objectives. This document reports progress toward implementing this strategy in 2010.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrumentation to Enhance Advanced Test Reactor Irradiations

The Department of Energy (DOE) designated the Advanced Test Reactor (ATR) as a National Scientific User Facility (NSUF) in April 2007 to support U.S. leadership in nuclear science and technology. By attracting new research users - universities, laboratories, and industry - the ATR will support basic and applied nuclear research and development, further advancing the nation's energy security needs. A key component of the ATR NSUF effort is to prove new in-pile instrumentation techniques that are capable of providing real-time measurements of key parameters during irradiation. To address this need, an assessment of instrumentation available and under-development at other test reactors has been completed. Based on this review, recommendations are made with respect to what instrumentation is needed at the ATR and a strategy has been developed for obtaining these sensors. Progress toward implementing this strategy is reported in this document. It is anticipated that this report will be updated on an annual basis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status Report on Efforts to Enhance Instrumentation to Support Advanced Test Reactor Irradiations

The Department of Energy (DOE) designated the Advanced Test Reactor (ATR) as a National Scientific User Facility (NSUF) in April 2007 to support the growth of nuclear science and technology in the United States (US). By attracting new research users - universities, laboratories, and industry - the ATR NSUF facilitates basic and applied nuclear research and development, further advancing the nation's energy security needs. A key component of the ATR NSUF effort at the Idaho National Laboratory (INL) is to design, develop, and deploy new in-pile instrumentation techniques that are capable of providing real-time measurements of key parameters during irradiation. To address this need, an assessment of instrumentation available and under-development at other test reactors was completed. Based on this initial review, recommendations were made with respect to what instrumentation is needed at the ATR, and a strategy was developed for obtaining these sensors. In 2009, a report was issued documenting this program’s strategy and initial progress toward accomplishing program objectives. Since 2009, annual reports have been issued to provide updates on the program strategy and the progress made on implementing the strategy. This report provides an update reflecting progress as of January 2014.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simplifying the Advanced Test Reactor LOWE Element Test Series

The Advanced Test Reactor (ATR) is one of six remaining high performance research reactors in the United States scheduled to be converted from 93% high-enriched uranium (HEU) fuel to 19.75% low-enriched uranium (LEU) fuel as part of the Department of Energy (DOE), National Nuclear Security Administration (NNSA), Office of Material Management and Minimization (MMM) reactor conversion efforts(1). The specific LEU fuel element design for the ATR is called the Low Enriched (LOWE) element. A series of fuel qualification tests are scheduled to occur over the next decade before the ATR is fully converted. In addition to several experiments of demonstration plates, a series of Element Tests (ETs) are planned for conversion, in which full sized LOWE elements are placed in ATR driver positions. The purpose of these ETs was generally to sequentially increase the amount of LEU and core power to full power, therefore creating a representative safety profile in which LEU could operate for the duration of the ATR lifetime. The planned element tests were (2): ET-1: one LOWE element at low power for once cycle ET-2: ~8 LOWE elements at low/medium power for multiple cycles, and ET-3: >8 LOWE elements for a full lobe of elements at high power for multiple cycles. Given recent improvements in modeling fidelity, scheduling considerations, and an opportunity to combine later ETs, the LEU conversion program successfully defined the operational requirements for the “ET-ATR” test, which combines the needed information collected from ET-2 and ET-3 into a single test.

42 ENGINEERING↗

Modeling of the Advanced Test Reactor Using OpenMC, Cubit and Griffin

In the pursuit of the ability to perform multiphysics simulations of the Advanced Test Reactor, it is crucial to have a fast and highly accurate deterministic model. To achieve this, a contemporary two-step method is employed. The first step involves generating homogenized cross sections using OpenMC, a cutting-edge Monte Carlo neutron transport code. OpenMC offers excellent modular capabilities, allowing for easy component integration and flexibility in incorporating new designs into the model. The second step involves deterministic transport calculations, which are performed using Griffin, a reactor multiphysics application based on the Multiphysics Object-Oriented Simulation Environment. To ensure the accurate spatial resolution and assignment of material cross sections, a Cubit-generated mesh for the Advanced Test Reactor is utilized as an intermediate step between the OpenMC and Griffin models; Griffin utilizes the mesh for its finite element solution, while OpenMC material IDs are written to the mesh file to be used in Griffin material assignments. Additionally, a Python-based script converts the cross sections generated by OpenMC into the ISOXML format required by Griffin. Preliminary comparisons indicate good agreement between the neutron multiplication factors obtained from the standalone OpenMC model and the Griffin model, with differences of less than 50 pcm in the two-dimensional geometry configuration. However, in three-dimensional calculations, an unacceptably large error is found in the Griffin solution. Future work is planned to resolve this discrepancy.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Validation of the Fast and Thermal Neutron Flux Profiles in the Advanced Test Reactor for the AGR-3/4 Experiment

The AGR-3/4 experiment was designed to irradiate TRISO particle fuel in the Advanced Test Reactor (ATR) at the Idaho National Laboratory. Temperature control of the test capsules containing the TRISO particles was important since the goal was to measure diffusion rates of fission product elements through graphite as a function of temperature. During the experiment, differences were observed between temperatures measured by the thermocouples and temperatures calculated with the thermal analysis model. To rule out the possibility that the used ATR driver fuel elements were the root cause of these temperature differences, an experiment was devised to measure the axial fast and thermal neutron flux profiles in the northeast flux trap containing the AGR-3/4 experiment. An important input parameter to the thermal analysis model was the calculated compact heat rates from the MCNP physics model. To verify these calculated heat rates were consistent with the ATR driver fuel element loading and operating lobe power, axial flux wires were inserted into ATR northeast flux trap. The measured fast and thermal neutron axial flux profiles derived from the flux wire activation showed excellent agreement with the calculated flux profiles. This agreement dispelled any concerns that the used ATR fuel elements in the northeast lobe might have introduced unusual axial flux variation. In addition, the agreement provided a validation basis for the physics calculation, specifically, (1) MCNP physics model, (2) Monte Carlo depletion methodology, (3) method used to load the ATR driver fuel, and (4) ATR measured lobe power data used in the calculation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radioisotope production at the advanced test reactor: process and lessons learned

The mission of the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) focuses on creating irradiation facilities for nuclear materials and fuels research. While radioisotope production is not a core part of the ATR mission, it is important for providing a U.S. domestic source of critical radioisotopes such as cobalt-60 (Co-60). Here, this paper gives an overview for radioisotopes currently being produced in ATR as well as other potential radioisotopes that can be produced in ATR. It also provides guidance on radioisotope production that can be applied to other test reactors.

ATR↗

After Action Report: Advanced Test Reactor Complex 2015 Evaluated Drill October 6, 2015

The Advanced Test Reactor (ATR) Complex, operated by Battelle Energy Alliance, LLC, at the Idaho National Laboratory (INL) conducted an evaluated drill on October 6, 2015, to allow the ATR Complex emergency response organization (ERO) to demonstrate the ability to respond to and mitigate an emergency by implementing the requirements of DOE O 151.1C, “Comprehensive Emergency Management System.”

99 GENERAL AND MISCELLANEOUS↗