Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced condition monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization through Integration of Miniaturized High Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

High-Temperature Multi-Process Sensor Development and Demonstration at a Full-scale PC Combustion System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution of wall conditions in utility boilers. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of a coal-fired utility boiler in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution of wall conditions in utility boilers. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of a coal-fired utility boiler in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

42 ENGINEERING↗

Distributed, Intelligent Edge-Sensing for a Smarter Grid

The electric grid is undergoing major transformations and developments resulting in unprecedented levels of volatility, uncertainty, and stress on grid infrastructure. Smart sensors and methods aiding in advanced visibility and situational awareness are key for tackling these issues. In this work, a decentralized architecture is proposed, where sensing, local computation and control capability are embedded in the edge devices, communicating with a set of trusted 'data mules' in a 'delay-tolerant' manner, while functioning autonomously. This system has been designed and implemented as an overall platform – called Global Asset Monitoring, Management and Analytics (GAMMA) Platform intended to provide the backbone for a global array of sensors and actuators. Further, as a building block for advanced current sensing solutions, a smart, low-cost ‘clip-on’ current sensor based on PCB-embedded Rogowski coil has been developed. The sensor hosts a novel signal conditioning stage allowing an 'auto-tuning' feature, resulting in a universal current sensor design for measuring a wide range of currents, including faults for smart grid applications. Finally, the research proposes a method to instrument and monitor key parameters for the most common electric utility asset – the pole-top distribution transformer. The work done in this research enables scalable, edge-intelligent sensing solutions for monitoring grid infrastructure, allowing utility operators to gain advanced visibility in an economical way.

Kulkarni, Shreyas Bhalchandra↗

Technology Maturation of Wireless Harsh Environment Sensors For Improved Condition Based Monitoring Of Coal Fired Power Generation

The overall goal of this project was to demonstrate and develop the usage of high-temperature (HT) harsh-environment (HE) wireless surface acoustic wave resonator (SAWR) sensor technology to promote reliable maintenance through condition-based maintenance (CBM) for field applications in harsh service conditions associated with power plant environments. The project aimed to advance the HT HE wireless SAWR sensor technology from TRL 5 to TRL 7. In addition to HT HE wireless temperature sensing, efforts were dedicated during this project to investigate, develop and increase the TRL from 3 to 5 for the following technologies: (a) HT HE strain sensors to address additional CBM monitoring needs, such as boiler tube mechanical / thermal stresses, which can provide early indications for boiler tube cracking and failure; and (b) HT aluminum nitride (AlN) and scandium aluminum nitride (ScAlN) based piezoelectric thin film fabrication and implementation of SAW sensors, with the goal of releasing the need to use single crystal piezoelectric materials for SAWRs and thus broaden possible technology applications to non-planar and harder to modify surfaces. To achieve the goals mentioned above, UMaine and its partner, Environetix Technologies Corporation, established partnerships with the following power plants: Longview Power (Maidsville, WV), a coal-fired power plant; Penobscot Energy Recovery Corp (PERC, Orrington, ME), a waste-to-energy power plant; and the UMaine Steam Plant (Orono, ME), an oil / natural gas power plant. To realize wireless HT HE SAWR sensor systems in these harsh service conditions, the University of Maine research team worked with Environetix and these power plants to define, design, fabricate, test and validate a mature prototype wireless temperature SAWR sensor system for boiler tube applications within the HT HE of the reheater pass damper chamber to directly and wirelessly monitor the temperature at eighteen independent boiler tube locations. The system included three levels, or “tiers”, of wireless communication to enable remote monitoring: Tier 1, the wireless link in the reheater pass damper chamber directly accessing the sensors on the boilers; Tier 2, the wireless local area network link, transmitting processed sensor information within the power plant to the Tier 3, a commercial wireless signal carrier company for secure remote data monitoring outside of the power plant. Regarding the wireless sensor system installed at Longview Power, temperature information from the boilers was continuously transmitted from the Longview boilers at Maidsville, WV, to Environetix headquarters, Orono, ME, over a 34 month period, when the system was finally decommissioned. Strain sensors and piezoelectric ScAlN thin film sensors were successfully installed on the exhaust duct at the UMaine Steam Power plant. The advances in wireless strain sensors and thin film piezoelectric film fabrication and testing were performed mostly in UMaine laboratories and field tested at the UMaine Steam Plant, due to its close proximity to UMaine/Environetix, access to the plant facility, and due to difficulties in accessing the other power plants during the COVID shut-down period. The project accomplished the TRL level increase of the targeted CBM technologies through the successful fabrication, installation, test, and validation of dedicated and commercial wireless sensor systems, utilizing the three different power plants. The outcomes of this project, including the wireless sensor data capability, are expected to yield an advance for CBM in harsh power plant environments. The reduction of maintenance costs, improved safety during plant operation, and increased power plant efficiency will lead to increased revenues (i.e., fewer forced outages) due to better process monitoring enabled by the wireless HT HE SAWR temperature sensor technology.

20 FOSSIL-FUELED POWER PLANTS↗

Open data sets for assessing photovoltaic system reliability

Photovoltaic (PV) systems have become a cornerstone of renewable energy strategies, particularly due to the significant reduction in solar power costs over the past decade. However, the long-term reliability of PV installations presents a persistent challenge, requiring the development of advanced monitoring and predictive maintenance strategies. A wide range of data types is used to evaluate the health of PV systems, including environmental conditions, electrical performance, and inspection imagery. These data enable methodologies such as machine learning (ML) models for lifetime prediction and computer vision techniques for defect detection. However, the acquisition of high-quality and comprehensive data is difficult, particularly in terms of long-term consistency and data variety. Publicly available data sets serve as valuable resources for addressing these challenges, but they often suffer from fragmentation and are difficult to access. This paper presents a comprehensive review of existing open-source data sets related to PV degradation, analyzing their features, functionalities, and potential applications. We categorize these data sets based on the specific aspects of PV system information they cover, such as environmental conditions, operational monitoring, image inspection and module materials, and propose relevant tools and ML models for processing them. In addition, we propose practices for future data collection and usage, while also discussing potential directions in data-driven research. Our aim is to enhance data utilization and publication among researchers and industry professionals, promoting a deeper understanding of the role of data in enhancing the performance and durability of PV systems.

14 SOLAR ENERGY↗

Correlating Time-Resolved Pressure Measurements With Rim Sealing Effectiveness for Real-Time Turbine Health Monitoring

Purge flow is bled from the upstream compressor and supplied to the under-platform region to prevent hot main gas path ingress that damages vulnerable under-platform hardware components. A majority of turbine rim seal research has sought to identify methods of improving sealing technologies and understanding the physical mechanisms that drive ingress. While these studies directly support the design and analysis of advanced rim seal geometries and purge flow systems, the studies are limited in their applicability to real-time monitoring required for condition-based operation and maintenance. As operational hours increase for in-service engines, this lack of rim seal performance feedback results in progressive degradation of sealing effectiveness, thereby leading to reduced hardware life. To address this need for rim seal performance monitoring, this study utilizes measurements from a one-stage turbine research facility operating with true-scale engine hardware at engine-relevant conditions. Time-resolved pressure measurements collected from the rim seal region are regressed with sealing effectiveness through the use of common machine learning techniques to provide real-time feedback of sealing effectiveness. Two modeling approaches are presented that use a single sensor to predict sealing effectiveness accurately over a range of two turbine operating conditions. Here, the results show that an initial purely data-driven model can be further improved using domain knowledge of relevant turbine operations, which yields sealing effectiveness predictions within 3% of measured values.

42 ENGINEERING↗

Correlating Time-Resolved Pressure Measurements With Rim Sealing Effectiveness for Real-Time Turbine Health Monitoring

Purge flow is bled from the upstream compressor and supplied to the under-platform region to prevent hot main gas path ingress that damages vulnerable under-platform hardware components. A majority of turbine rim seal research has sought to identify methods of improving sealing technologies and understanding the physical mechanisms that drive ingress. While these studies directly support the design and analysis of advanced rim seal geometries and purge flow systems, the studies are limited in their applicability to real-time monitoring required for condition-based operation and maintenance. As operational hours increase for in-service engines, this lack of rim seal performance feedback results in progressive degradation of sealing effectiveness, thereby leading to reduced hardware life. To address this need for rim seal performance monitoring, the present study utilizes measurements from a one-stage turbine research facility operating with true-scale engine hardware at engine-relevant conditions. Time-resolved pressure measurements collected from the rim seal region are regressed with sealing effectiveness through the use of common machine learning techniques to provide real-time feedback of sealing effectiveness. Two modelling approaches are presented that use a single sensor to predict sealing effectiveness accurately over a range of two turbine operating conditions. Results show that an initial purely data-driven model can be further improved using domain knowledge of relevant turbine operations, which yields sealing effectiveness predictions within three percent of measured values.

Compressors↗

Embedded Aluminum Nitride Sensors for Advanced Reactors

This project aims to manipulate the of growth of aluminum nitride (AlN) inclusions in an iron-chromium-aluminum (FeCrAl) alloy, using the principle of powder metallurgy and heat treatment methods. to promote the formation of AlN phase within FeCrAl for embedded sensing. This effort seeks to fill in a gap with respect to robust sensor hardware for ubiquitous structural health monitoring of advanced nuclear reactors. A systematic evaluation of various solid-state methods will be performed to understand the influence of process conditions on AlN growth and to promote the growth of desirable AlN phase. Fabricated specimens will be analyzed to investigate the AlN structures that are formed using a suite of tools to characterize the concentration, morphology, and distribution of AlN within the FeCrAl substrate.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Wireless Sensor Modalities at a Nuclear Plant Site to Collect Vibration Data

One of the major contributors to the total operating costs of domestic nuclear fleet of reactors today is the operation and maintenance (O&M) costs. These include labor-intense preventive maintenance programs involving manually-performed inspection, calibration, testing, and maintenance of plant assets at periodic frequency and time-based replacement of assets at periodic frequency, irrespective of their conditions. This has resulted in a labor-centric business model to achieve high capacity factors. To build an optimal maintenance program, it’s time to transition from this labor-centric business model to a technology-centric business model. Fortunately, there are technologies (advanced sensor, data analytics, and risk assessment methodologies) that will support this transition. The technology-centric business model will result in significant plant life extension and reduction of time-based maintenance activities. This will drive down O&M costs as labor is a rising cost and technology is a declining cost. This approach will lay the foundation for real-time condition assessment of plant assets, allowing condition-based maintenance to enhance plant safety, reliability, and economics of operation. The goal of this project is to address challenges in the area of digital monitoring, i.e., the application of advanced sensor technologies (particularly wireless sensor technologies) and science-based data analytic capabilities to advance online monitoring and predictive maintenance in nuclear plants to improve plant performance (efficiency gain and economic competitiveness). To achieve the project goal, in partnership with Exelon Generating Company (Exelon), researchers from Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) are performing research and development (R&D) to demonstrate application of wireless sensors using the distributed antenna system and advanced data analytics to achieve predictive maintenance. In the report, wireless vibration sensors, vibration data and its indicator are described. The wireless vibration sensors presented in this report support three types of wireless communication, namely, Wi-Fi, cellular, and 900 MHz. These wireless vibration sensors are considered by partner plant site for installation on plant asset to enable online vibration monitoring to replace periodic measurements. These vibration data along with other plant process data will be utilized to develop diagnostic and prognostic models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent Advances in Machine Learning for Fiber Optic Sensor Applications

Over the last three decades, fiber optic sensors (FOS) have gained a lot of attention for their wide range of monitoring applications across many industries, including aerospace, defense, security, civil engineering, and energy. FOS technologies hold great promise to form the backbone for next‐generation intelligent sensing platforms that offer long‐distance, high‐accuracy, distributed measurement capabilities and multiparametric monitoring with resilience to harsh environmental conditions. The major limitations posed by FOS are 1) cross‐sensitivity, 2) enormous volume and large data generation, 3) low data processing speed, 4) degradation of signal‐to‐noise ratio over the fiber length, and 5) overall cost of sensor and interrogator systems. These challenges can be overcome by building advanced data analytics engines enabled by recent breakthroughs in machine learning (ML) and artificial intelligence (AI). This article presents a comprehensive review of recent studies that integrate ML and AI algorithms with FOS technologies. This review also highlights several FOS technology development directions that promise a significant impact on widespread use for several industrial applications, with an emphasis on energy systems monitoring. A perspective on future directions for further research development is also provided.

97 MATHEMATICS AND COMPUTING↗

Monitoring river flow status using low-cost wildlife camera and image segmentation artificial intelligence

Continuous measurement and monitoring of surface water coverage in non-perennial streams are essential for understanding the exchange fluxes between surface and subsurface waters under both inundated and non-inundated conditions. In this study, a wildlife camera photo-based framework was developed to monitor small stream water inundation, depth, discharge, and velocity. Two advanced machine learning models, YOLOv8 and Mask2Former, were utilized to efficiently analyze images captured by wildlife cameras. The accuracy of the framework was validated against on-site depth measurements at six sites in the Yakima River Basin, along with the gage height, discharge, and velocity data from four USGS sites. This approach facilitates long-term, continuous monitoring and quantification of river intermittency and water availability with high precision and low cost, thereby advancing river ecosystem research and management.

machine learning↗

Arctic Deployment of a Fully Integrated Self-Powered Drifting Buoy Harvesting Wave Energy via a Triboelectric Nanogenerator

The Arctic Ocean remains one of the most poorly sampled regions on Earth, where improved in situ environmental monitoring is vital for advancing oceanographic and atmospheric studies. However, data collection efforts are constrained by the short operational lifespans and high costs of conventional systems. Drifting buoys powered by pendulum-driven wave energy harvesters offer a cost-effective alternative, yet earlier designs have neither been optimized for real-world wave conditions nor validated in the Arctic. In this study, we develop a self-powered drifting buoy that integrates a pendulum-driven triboelectric nanogenerator (TENG) system with a mechanical motion rectifier, a high-gear-ratio transmission, and power management circuits. Through coupled buoy–pendulum dynamic simulations and laboratory testing using a motion simulator, we identify an optimal pendulum mass of 1.6 kg (12.7% of total buoy weight) that maximizes energy output while maintaining buoy stability. Laboratory experiments achieved average power outputs of 12.7 mW under Arctic-like wave and temperature conditions. The system was successfully deployed in the Bering Sea, where it generated 11 J of energy in 3.1 m waves, marking the first Arctic deployment of a TENG-based drifting buoy for sea surface temperature monitoring. This work establishes a cost-effective framework for designing self-powered Arctic monitoring platforms and advances the feasibility of long-term environmental observations in real Arctic waters.

marine enerby↗

Acoustic Monitoring of Pyroprocessing Equipment

This paper provides an introduction to using acoustic monitoring to advance detection techniques for pyroprocessing in support of nuclear safeguards and non-proliferation. The usage of free air acoustic monitoring has been previously demonstrated at Idaho National Laboratory (INL) facilities such as the Advanced Test Reactor and the National Security Test Range. However, the proposed work revolves around a new deployment environment, the Fuel Conditioning Facility, that brings forward several questions regarding the performance of the technology in non-free air media. The confinement of the pyroprocessing equipment to a heavily shielded hot cell, the atmosphere of the hot cell containing argon gas, and the radiation dose inside the hot cell are all new environments for acoustic monitoring. To our knowledge, acoustic measurements have not been completed in such an environment before. This offers a new opportunity to study not only the acoustic signatures of the equipment inside of the hot cell, but also the propagation of the signals through the hot cell and at distances away from their origination. The objective of this paper is to explain the planned instruments to monitor the Fuel Conditioning Facility in order to evaluate acoustic signals emitted from equipment during various stages of operation. Identifying these signals can potentially enable the identification of specific pieces of equipment used in pyroprocessing and produce information of their operational status. If successful, this type of monitoring could offer a new method to aid in safeguards and proliferation detection of pyroprocessing activities.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

The ARENA Test Bed – A Versatile Resource for I&C Development and Validation

The Accelerated and Real-time Experimental Nodal Assessment (ARENA) Test Bed at the Pacific Northwest National Laboratory (PNNL) is a versatile resource for development and validation of instrumentation and control (I&C) technologies. This capability was created to facilitate in-situ testing of nuclear electrical cables in various simulated operational environments. Using cable trays, a control box, and selected test components, low voltage cables can be staged to experience local adverse environments such as elevated temperature and water immersion. Cable condition can be continuously monitored over time to track the effect of local stresses using nondestructive assessment tools. A heads-up display (ARENA TV) plots key data in real-time for users. The ARENA Test Bed has recently been used to evaluate the potential for spread spectrum time domain reflectometry (SSTDR) to monitor thermal aging of a portion of live cable powering a three-phase motor. The arrangement provided the opportunity to directly compare the performance of the novel online SSTDR method with offline results from the more standard frequency domain reflectometry (FDR) method. The ability of SSTDR and FDR to identify the presence of water in immersed shielded and unshielded cables and to detect ground faults was also assessed. A digital twin is being developed to track and predict FDR signals from a thermally aging conceptual cable region to compare with measured signals from the ARENA physical counterpart. The test bed concept addresses an important need in nuclear I&C monitoring tool development. New tools and techniques can be developed in the test bed and validated versus known methods and physical measurements. Digital twins and machine learning engines can be populated with measured data in a controlled environment that would not be readily available in the actual nuclear power plant. Proposed monitoring strategies can be confirmed for effectiveness through objective evaluation. It is anticipated that the PNNL ARENA Test Bed will be a valuable resource in advancing nuclear plant instrumentation.

nuclear electrical cables, ARENA Test Bed, conditi↗

Monitoring of Photovoltaic (PV) Performance and Degradation: Integrated Renewable Energy Systems (IRES) - PV Monitoring Task

The Integrated Renewable Energy System (IRES) testbed demonstration at the Pacific Northwest National Laboratory (PNNL) Sequim campus includes development of a suite of capabilities for tracking the performance of photovoltaic (PV) renewable energy components located on a floating platform (floating PV) and on a shoreline building rooftop. The marine environment represents potentially harsh and corrosive conditions for PV modules. Compared to terrestrial PV, potential concerns for offshore PV arising from high humidity and occasional contact with saltwater, marine wildlife, and aquaculture. These environmental factors can reduce electricity generation efficiency and increase the risk of electrical faults, polymer insulation or jacketing degradation and hydrolysis of the PV cell encapsulant materials. Offshore PV modules may also be exposed to lower temperatures and buoyant and vibrating motions with a floating platform. It is not clear how the long-term performance of floating PV will be affected by these factors. To understand expected energy generation through solar cells on a floating platform, monitoring of the performance of PV modules in the marine environment is needed. This report outlines a plan for long-term testing of IRES PV components utilizing resources of the PNNL Material Aging and Detection (MAaD) Science team and the Marine and Coastal Research Laboratory (MCRL). Equipment applicable for onsite testing and real-time monitoring of the PV performance associated with environmental conditions including temperature, solar irradiance, shading and soiling is included. In case of performance loss, equipment for fault detection, failure analysis, material testing, and further troubleshooting are also available. Through establishment of this capabilities, the enabling IRES project sets the stage for future research to advance off-shore and near-shore energy options for businesses and communities.

14 SOLAR ENERGY↗