Search NASA⌕ Search

SEARCH · Search NASA

Results for “Air separation unit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Local Air Quality Impacts of a Peak-Shaving Diesel Generator Unit in Waynesville, North Carolina

The Waynesville Electric Department in Waynesville, North Carolina, operates a 2,000-kW diesel generator with a 4% capacity factor, emitting less than 1 ton annually of PM2.5, VOCs, carbon monoxide (CO), and sulfur dioxide (SO2), and approximately 1.8 tons of NO. The National Laboratory of the Rockies (NLR) conducted high-resolution, near-source air-quality modeling to evaluate the generator's impacts. Results indicate minimal effects on ambient pollutant concentrations: annual PM2.5 increases are below 0.0004 microgrm/m3 for local census tracts, while CO and SO2 levels increase by less than 0.00004 ppm and 0.0002 ppb, respectively. Estimated annual premature mortality attributable to PM2.5 exposure is less than 0.001 cases across Haywood County, with an associated economic impact of approximately $12,000. This report complements a separate technoeconomic analysis to inform Waynesville's investment strategies for demand reduction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Polar Bear™ – Innovative Capture of Storage Tank Vapors

Polar Bear™ is a patented technology developed by the Energy & Environmental Research Center (EERC) to capture storage tank vapors and eliminate methane emissions from upstream oil- and gas-producing facilities. Sparked by early commercial investment, the EERC licensed the technology and extended the intellectual property to storage tanks. Polar Bear™ is uniquely engineered and adapted to individual lower-producing facilities where there is otherwise no economic alternative for capturing tank vapors. A high number of small producing oil and gas wells are distributed across the country. The aggregate contributes to a significant volume of emissions. Because of the lack of economy of scale, gas volumes from these facilities are typically not recovered and contribute to methane emissions. Polar Bear™ provides a fit-for-purpose compression solution that addresses cost by reducing complexity with respect to conventional vapor recovery units and eliminating oil changes. Unique to Polar Bear™ is the capability to separate oxygenated gas from storage tank vapors. Storage tanks are designed to “breathe,” allowing gas to enter and escape during internal level and temperature changes. This infiltration of air into the tank headspace imparts undesirable oxygen content with respect to pipeline gathering. Polar Bear™ separates the vapor stream, allowing oxygen-rich gas to be used as fuel on-site while recovering the liquids-rich portion of the gas where oxygen content is minimized. A prototype system was tested to verify process models, evaluate operational performance, and advance the technology readiness level from 5 to 6. Results provide a good match between experimental measurements and process models, indicating the models are useful for future scale-up and field design. Various mixtures of nitrogen and liquefied petroleum gas were tested to understand the mass balance of nitrogen and how it relates to the potential control of oxygen content. Findings indicate that less than 2000 ppm of oxygen is likely to remain in the liquid portion of the gas in field applications. The research and development prepare the technology for field implementation to eliminate routine and fugitive methane emissions from storage tanks.

02 PETROLEUM↗

Separating Sensible and Latent Cooling with Electrically Charged Rotating Vortexes and Vapor Capturing Air Handler Technology

The dehumidification of air is a highly energy-intensive process, typically requiring vapor compression systems to cool the air below its dew point temperature. This project investigated air dehumidification achieved by electrostatic and dielectrophoresis forces in electrosprays and centrifugal principles in cyclone separators. As a practical implementation of these processes, Electrospray Vortical Flow eXchanger (EVFX) prototypes were designed, fabricated, and tested. Electrosprays were employed to energize water droplets, which then captured water vapor via dielectrophoresis. A cyclone separator was positioned downstream of the electrosprays. This combination increased the dehumidification efficiency and controlled the flow of the water vapor condensate removed from the air.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analyzing LF/VLF Lightning Waveforms to Estimate D-region Electron Density Profiles

Lightning waveforms in the low frequency (LF; 30-300 kHz) and the very low frequency (VLF; 3-30 kHz) bands can be exploited to produce data-driven ionospheric D-region electron density profile (EDP) estimates with significantly higher spatial and temporal coverage than previously available. The lightning waveforms used in this paper are signals detected in the LF/VLF of negative cloud-to-ground lightning by the Earth Networks Total Lightning Detection Network. Each waveform contains a ground wave and a time-delayed ionospheric reflection. The time delay between the ground wave and ionospheric reflection has previously been used to estimate a single specular reflection altitude, where LF/VLF emissions are reflected by the ionosphere. Here, we expand upon previous methods to include filtering and spectral analysis, and account for oblique propagation to produce higher-order estimates for reflection altitudes and corresponding electron densities. Once estimated, reflection altitudes and corresponding electron densities can be used to derive parameters β and h’, which define an EDP for the D-region. In this study, the lightning waveform (LW) analysis is demonstrated using a single representative 24-hour dataset over the Southeast United States, and then extended to a total of 10 separate datasets with varying locations and ionospheric conditions. The LW-derived D-region EDPs are in agreement with predictions made by the Faraday International Reference Ionosphere model, and the LW EDPs β and h’ values are consistent with previous LF/VLF-derived estimates.

D-region ionosphere↗

SPRUCE Surface N2O fluxes measured with LI-7820, 2024

This dataset contains N2O (nitrous oxide) efflux rates measurements from the Spruce and Peatland Responses Under Changing Environments (SPRUCE) experimental site within the Marcell Experimental Forest in northern Minnesota, USA. Measurements were made manually with a LiCor N2O/H2O analyzer (LI-7820) and paired SmartChamber (LI-8200-01S) in June, August, and October (2024-06-24 to 2024-10-22). During each measurement, the SmartChamber was placed on 8” PVC collars that were installed in May 2024. N2O flux was derived from 10-minute flux measurements processed using SoilFluxPro software (v5.3.1) and fit to a linear model. Model slope and R2 are reported along with soil water, soil temperature, and air temperature observations made with SmartChamber sensors. N2O is a gaseous N species formed during the microbial processes of denitrification and ammonia oxidation, and is a powerful greenhouse gas. This dataset contains one data file in comma-separate values (*.csv) format. Additional metadata are provided: one data dictionary and a file-level metadata file in comma-separate values (.csv) format and a user guide in PDF (*.pdf) format.

54 ENVIRONMENTAL SCIENCES↗

Multi-Split Variable Refrigerant Flow (VRF) System Building Energy Simulations Using Performance Maps

Multi-split variable refrigerant flow (VRF) systems are highly energy-efficient HVAC (heating, ventilation and air conditioning) technologies that connect a single outdoor unit to multiple independent indoor terminal units using a common refrigerant circuit and a variable-speed compressor. Building energy simulations that incorporate VRF systems help model their unique operational characteristics and predict energy consumption in specific building designs. Traditionally, EnergyPlus models these systems by employing multiple sets of performance curves to characterize both individual terminal units and the outdoor unit. However, producing these curves is labor intensive and error prone, and they often do not capture all the key input and output variables. This paper introduces a novel approach that uses multi-dimensional performance maps to model VRF systems in building environments for space cooling. In this approach, performance maps are developed at the component level—separately for the outdoor unit and for each indoor terminal. The new modeling method is validated within EnergyPlus via a Python plug-in that contains a simple solver loop to coordinate the component-level, indoor, and outdoor unit maps. Furthermore, because performance maps can span more variables than traditional performance curves, they offer the opportunity to implement advanced controls, such as enhanced dehumidification and compressor modulation. A VRF air conditioner’s hardware system was modeled using the DOE/ORNL Heat Pump Design Model, which was automated to produce extensive performance maps for both the indoor and outdoor units.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

Electrospinner Upgrades for Nanofiber Production

Electrospinning is an inexpensive and flexible method for producing nanofibers. Nanofibers are highly adaptable with potential applications in accelerator target systems, air and water filtration, and biomedicine. This project aims to upgrade and test an existing roll-to-roll electrospinner that is more economical for industrial nanofiber production. Varying the diameter of nanofiber can change its functional properties. The current unit cannot adjust spinneret-collector separation, which determines nanofiber diameter. The electro-spinneret channel also does not have lateral adjustment capabilities for precise alignment. Lastly, the viscosities of our polymer solutions have not been quantified. Solution injection into the channel is presently inconsistent because of imperfect nozzle sizing, resulting in waste and decreased efficiency. Modeling was done with Siemens NX CAD software, and viscosity was measured using a Brookfield DVE-LV viscometer. A dual scissor lift design for channel displacement, powered by a dual-shaft DC motor coupled to precision lead screws, was approved and construction was started. Preliminary channel modifications also were initiated. Going forward, the scissor lift system will be integrated and evaluated with our electrospinner, along with further channel modifications. Viscosity measurements of polyvinyldimethylformamide (PVDF) were recorded with inconsistent results due to inadequate testing conditions. Future viscosity trials must be completed in accordance with testing requirements. The optimization and commercialization of roll-to-roll electrospinner units can make nanofiber production more feasible for many new industries and consumer products.

Black, Niko↗

Crystallization-assisted water adsorption in amorphous molecular adsorbents

Efficient and stable water adsorbents are essential for removing moisture from natural gas and olefins during their production. Industrial desiccants such as alumina and zeolites require high regeneration temperatures, while metal-organic frameworks often suffer from limited long-term stability and reusability. Here, we introduce a new type of molecular desiccants (M-PyC) that, in principle, can be reused indefinitely. These simple molecular coordination complexes undergo fully reversible phase transitions between crystalline and amorphous states through the decoordination (bond breaking) and recoordination (bond reforming) of water molecules. They exhibit high water uptake (30 wt%) and superb selectivity, excluding hydrocarbons entirely. Their effectiveness for dehydration, combined with low regeneration temperature, fast desorption kinetics, low-cost and green synthesis, easy scalability to kilogram quantities, and essentially unlimited recyclability, makes them truly competitive dehydration agents for industrial separations. The use of amorphous molecular adsorbents, where crystallinity and porosity are no longer stringent requirements, and the adsorption-desorption process entirely under ambient air, offers a conceptually different approach to adsorption-based separation science and potentially realistic solution to the long-standing challenge of sustained stability in coordinate-bonded adsorbents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Iodination of PEGylated Polymers Counteracts the Inhibition of Fibrinogen Adsorption by PEG

Poly(ethylene glycol), PEG, known to inhibit protein adsorption, is widely used on the surfaces of biomedical devices when biofilm formation is undesirable. Poly(desaminotyrosyl-tyrosine ethyl ester carbonate), PDTEC, PC for short, has been a promising coating polymer for insertion devices, and it has been anticipated that PEG plays a similar role if it is copolymerized with PC. Earlier studies show that no fibrinogen (Fg) is adsorbed onto PC polymers with PEG beyond the threshold weight percentage. This is attributed to the phase separation of PEG. Further, iodination of the PC units in the PC polymer, (I 2 PC), has been found to counteract this Fg-repulsive effect by PEG. Here, in this study, we employ surface-sensitive X-ray techniques to demonstrate the surface affinity of Fg toward the air–water interface, particularly in the presence of self-assembled PC-based film, in which its constituent polymer units are assumed to be much more mobile as a free-standing film. Fg is found to form a Gibbs monolayer with its long axis parallel to the aqueous surface, thus maximizing its interactions with hydrophobic interfaces. It influences the amount of insoluble, surface-bound I 2 PC likely due to the desorption of the formed Fg–I 2 PC complex and/or the penetration of Fg onto the I 2 PC film. The results show that the phase behavior at the liquid–polymer interface shall be taken into account for the surface behavior of bulk polymers surrounded by tissue. The ability of PEG units rearranging into a protein-blocking layer, rather than its mere presence in the polymer, is the key to antifouling characteristics desired for polymeric coating on insertion devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Xanthos-Lake Dataset

The Xanthos-Lake v1.0 dataset provides the input data, trained machine-learning models, and simulation outputs needed to characterize lake water balance, snow and ice conditions, and mixing-layer temperature within the Xanthos global hydrological modeling framework. The dataset supports lake representation across a wide range of lake sizes and hydroclimatic conditions by combining xLSIM, a basin-specific machine-learning emulator of lake snow, ice, ice-cover fraction, and mixing-layer temperature, with the Xanthos-Lake water-balance model. The archive contains NetCDF datasets used to train and evaluate xLSIM, trained model weights, processed meteorological and lake-property inputs, and basin- and lake-category-specific simulation outputs. These materials are organized into four primary data groups, described below. Snowice_model_inputs: Contains the NetCDF input data used to train xLSIM. The xLSIM machine-learning framework uses three lake-based datasets. The meteorological forcing dataset provides monthly relative humidity, specific humidity, surface wind speed, maximum and minimum air temperature, downward longwave and shortwave radiation, snowfall, surface air pressure, and total precipitation. Lake surface area is included as an additional static predictor. The target-state dataset provides lake ice thickness, snow depth, snow cover, and lake mixing-layer temperature, while a companion lake-surface dataset provides the lake ice-cover fraction. Before training, ice thickness and snow depth are converted from meters to centimeters, mixing-layer temperature is converted from kelvin to degrees Celsius and constrained to nonnegative values, and ice-cover fraction is converted from a fraction to a percentage. The predictor variables are normalized using statistics calculated across the selected lakes and time steps. Snowice_model_outputs: Contains the NetCDF outputs generated by xLSIM. For each basin, xLSIM produces a file containing observed and predicted lake-state variables for the training, validation, and testing periods. The modeled variables include lake ice thickness, snow depth, snow cover, mixing-layer temperature, and lake ice-cover fraction. For basins without a sufficiently persistent snow-and-ice signal, the emulator predicts only mixing-layer temperature. The outputs also include training and validation loss histories, the selected model configuration, identifiers of the lakes used in training, and SHAP-based feature-importance information at the global, lake, and seasonal-regime levels. The trained machine-learning model weights are provided separately within the dataset archive. Together, these files support model evaluation and subsequent coupling with the Xanthos-Lake water-balance framework. XanthosLAKES: Contains the NetCDF input data used by the Xanthos-Lake framework. Monthly meteorological inputs include relative and specific humidity, downward shortwave and longwave radiation, mean, maximum, and minimum air temperature, wind speed, precipitation, snowfall, and surface air pressure. Static lake-property datasets provide lake identifiers, geographic locations, surface area, volume, mean depth, elevation, drainage area, fetch, outlet-routing information, and associated Xanthos grid-cell attributes. Separate bathymetric datasets provide the coefficients of the area–depth and volume–depth relationships for each aggregated lake unit. GLEV-based records provide observed lake surface area and evaporation data used to initialize lake states, define reference conditions, and calibrate and evaluate the model. Xanthos-Lake Outputs: Contains the basin- and lake-category-specific NetCDF outputs generated by Xanthos-Lake. Monthly variables include lake surface area, storage volume, outlet discharge, evaporation rate, evaporation volume, lake–groundwater exchange, lake inflow, ice thickness, snow depth, snow-cover fraction, ice-cover fraction, and mixing-layer temperature. The files also contain lake-specific calibration and validation statistics, including normalized root-mean-square error, mean absolute error, Nash–Sutcliffe efficiency, Kling–Gupta efficiency, and percent bias. Stored calibrated and derived parameters include the weir discharge coefficient, fractional freeboard, groundwater exchange coefficient, reference water level, corresponding reference surface area and storage volume, weir-width adjustment factor, and the fraction of routed inflow entering the lake. Basin identifiers, lake category, simulation period, calibration and validation periods, and parameter-schema information are retained as NetCDF metadata.

Abeshu, Guta [Pacific Northwest National Laborator↗

TARP Identifying Critical Thresholds for Acute Response of Plants and Ecosystems to Water Stress at Walker Branch Watershed, 2002-2005

This dataset contains data from a manipulative field study aimed at identifying critical thresholds for acute response of plants and ecosystems to water stress (TARP) that took place at Walker Branch Watershed in Oak Ridge, Tennessee from 2002-2005 (2002-06-20 to 2005-12-16). The study used understory tents for the removal of 100% of the growing-season throughfall and stem flow, to provide data on the impact of acute drought on mechanisms responsible for growth and mortality of deciduous forest canopy trees representative of common plant functional types (Liriodendron and Quercus). Through three years of manipulation (2003, 2004 and 2005; pretreatment measurements in 2002) various measures of tree response to surface moisture deficits were recorded including root and leaf traits, plant nonstructural carbohydrates status, hourly sapflow, basal area, and periodic observations of foliar photosynthesis and conductance. Additionally, environmental data such as air and soil temperature, soil water content, and soil matric potential were recorded. This dataset contains data 16 files in comma-separate (*.csv) format. Additional metadata are provided: 16 data dictionaries and a file-level metadata file in comma separate (*.csv) format and a user guide in PDF (*.pdf) format.

basal area↗

Research, Development and Demonstration of Advanced Vehicle Technologies in Clean Motor Fuels (CRADA Final Report)

NREL/DOE has been funding research, development, and demonstration (RD&D) projects to facilitate the deployment of alternative fuels into the marketplace in order to achieve three objectives: 1) enhance the reduction of mobile source emissions in California and the U.S.; 2) increase U.S. competitiveness and economic prosperity; and 3) preserve the environment through the reduction of emissions and toxins from the motor vehicle population. The Lewis-Presley Air Quality Management Act requires the South Coast Air Quality Management District to establish a program to encourage participation in projects to increase the utilization of clean-burning fuels. The parties seek to collaborate on a joint RD&D project to perform a field test on a small vehicle fleet operating on Fischer-Tropsch synthetic diesel fuel. Recently the 106th U.S. Congress designated "gas-to-liquid" (GTL) transportation fuels that are produced from domestic products as alternative fuels under the Energy Policy Act of 1992 (EPACT). Niche markets could develop quickly for these fuel products, perhaps especially for the use of Fischer-Tropsch synthetic fuels in centrally fueled vehicle fleets in California. NREL and its project partners from the U.S. Department of Energy and West Virginia University have recently conducted what we believe to be the first-ever controlled tests of Fischer-Tropsch synthetic fuels in heavy vehicles. These tests have shown that Fischer-Tropsch fuels can be substituted in unmodified trucks and buses without any detectable loss in drivability and performance. Compared to a California diesel fuel baseline, neat Shell Fischer-Tropsch fuel emitted about 12% lower NOx and 24% lower particulate matter over a five-mile driving route while maintaining the same fuel economy on an energy equivalent basis. Whereas these exhaust emissions reductions from these previous studies have been impressive, far greater exhaust emissions reductions can be achieved if the vehicles are retrofitted with emissions control technologies that are enabled by Fischer-Tropsch fuels. For this program, a test fleet would be selected and retrofitted with continuously regenerating traps (CRT’s) or diesel particulate filters (DPF's). The University of West Virginia, under a separate subcontract to SCAQMD will have the responsibility to test and measure the emissions from the test fleet of vehicles.

33 ADVANCED PROPULSION SYSTEMS↗

Electrochemical Direct Air Capture of CO 2 Using Redox-Active Textiles

We have used vapor phase chemistry to construct a textile electrode that comprises an immobilized PCET agent, poly(1-aminoanthraquinone) (PAAQ) encapsulated within a conductive polymer, and incorporated it into CO 2 -separating electrochemical flow cells. This system facilitates pH-swing-driven carbon capture from a 1% CO 2 feed and air, with the former at a competitively low energetic cost of 202 kJ/molCO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SPARTAN and IMPROVE Comparison Experiment (SPICE) Interim Campaign Report

SPICE (the SPARTAN and IMPROVE Comparison Experiment) aims to obtain and quantify comparisons between aerosol PM 2.5 mass concentration measurements from the University of Oklahoma (OU) Surface Particulate Matter Network (SPARTAN) station and the U.S. Environmental Protection Agency (EPA) Interagency Monitoring of Protected Visual Environments (IMPROVE) station hosted by the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility at ARM’s Southern Great Plains (SGP) observatory in Oklahoma. Aerosols—both natural and anthropogenic—affect human populations in multiple ways. Much of ARM’s research focuses on how aerosols influence weather and climate through their optical and radiative effects, as well as their impacts on clouds and precipitation. However, aerosols also pose direct risks to humans and other organisms through inhalation, with the severity of health impacts depending on particle size, chemical composition, and duration of exposure. The IMPROVE network was established by the U.S. EPA to monitor air quality, including visible clarity as well as total and chemically speciated aerosol mass concentrations. The ARM SGP site hosts the IMPROVE SOGP station. Separately, the SPARTAN network operates a globally distributed set of stations similar to IMPROVE but with an emphasis on remote deployment and semi-autonomous operation for use beyond the borders of the United States (IMPROVE only operates within the U.S.). The University of Oklahoma operates a SPARTAN station. To establish confidence in the OU SPARTAN instrumentation and measurement protocol relative to the EPA-certified IMPROVE station, the OU SPARTAN station is currently deployed at SGP in close proximity to the IMPROVE SOGP station. The SPICE campaign was envisioned as a contiguous calendar-year effort for 2025 to capture seasonal variation in mass loading as well as composition. However, independent of the SPICE campaign, the SPARTAN network adopted a new filter construction part-way through the year, interrupting our contiguous data set. Thus, to obtain a contiguous data set with a uniform consistent configuration, SPICE desires an extension through 2026.

54 ENVIRONMENTAL SCIENCES↗

MRPP UO x Product Recover System Upgrade

The Material Recovery Pilot Plant (MRPP) produces U 3 O 8 /OU 3 product in powder form. This product must be collected, and cyclonic separators are an efficient method for collecting particles from an air stream. However, the M10 SafeVac currently installed at MRPP has design flaws and is failing. A new, semi-custom cyclonic separator from Hanningfield has been designed and ordered to replace the SafeVac. The Hanningfield model will be more efficient and better designed to suit the recovery at MRPP, increasing the quality of research produced at the plant. Unit cost is $118,000 with a 24 week lead time. It is expected to be operational by January 2025.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mission Analysis for Marine Renewable Energy to Provide Power for Marine Carbon Dioxide Removal

The mission of this project was to provide a preliminary feasibility assessment of powering different marine carbon dioxide removal (mCDR), marine carbon capture, and marine carbon sequestration strategies with marine energy. In this report, carbon capture refers to methods that can separate or capture carbon dioxide (CO 2 ) from the air or ocean; carbon sequestration refers to methods that store CO 2 obtained by capture methods out of the atmosphere for long periods of time; and carbon dioxide removal (CDR) refers to methods that do both. The project found that mCDR powered by marine energy and offshore wind energy available in the United States could meet global CDR scales needed by 2040 and 2050 to limit warming to 1.5 degrees C by 2100. Note that this preliminary estimate assumes that it is possible to harvest all the marine and offshore wind resources available in the United States with existing technology options, and it does not account for the power needed for monitoring these methods, as these power needs are not yet well defined and require further research. Additionally, these CDR scales will still require emissions reductions.

16 TIDAL AND WAVE POWER↗

H 2 O and CO 2 Sorption in Ion-Exchange Sorbents: Distinct Interactions in Amine Versus Quaternary Ammonium Materials

This article examines how water (H₂O) and carbon dioxide (CO₂) interact with two classes of ion-exchange sorbents — a primary amine sorbent and a quaternary ammonium (QA⁺) sorbent — using calorimetry, thermal gravimetric analysis, gas analysis, and molecular modeling. Here, the QA⁺ sorbent exhibits stronger binding to both H₂O and CO₂ but also shows thermal stability limitations. Mixed-gas experiments reveal that humidity strongly influences CO₂ uptake and that moisture-driven sorbent regeneration enables cyclic moisture swing CO₂ capture, with implications for low-energy CO₂ separation from dilute gas streams.

36 MATERIALS SCIENCE↗

Modeling the use of mobile modular gas samplers in near-field detection

The Wireless Independent Noble Gas Sampler (WINGS) is a mobile, modular gas sampling system designed for use in low infrastructure environments. In the case of a suspected underground nuclear explosion (UNE), WINGS units could be deployed to detect noble gases emanating from the suspected explosion site or identify gases originating from another source entering the local area from offsite. In conclusion, this work uses the atmospheric transport modeling tool inline WRF-HYSPLIT to test the effectiveness of WINGS units around a suspected UNE site as a function of sampler density and distance from the emission point of gases from a UNE.

Air sampling↗