Search NASA⌕ Search

SEARCH · Search NASA

Results for “Airborne Imaging Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Estimation of Aerosol Optical Depth, Pressure Elevation, Water Vapor and Calculation of Apparent Surface Reflectance from Radiance Measured by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) Using a Radiative Transfer Code

The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is an imaging spectrometer that measures spatial images of the total up welling spectral radiance from 400 to 2500 nm at 10 nm spectral intervals. Quantitiative research and application objectives for surface investigations require conversion of the measured radiance to surface reflectance or surface leaving radiance. In this paper we describe a set of algorithms to estimate aerosol optical depth, atmospheric water vapor, and surface pressure height from the AVIRIS measured radiance.

infrared↗

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) spectrometer design and performance

The development of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) has been completed at JPL. This paper outlines the functional requirements of the spectrometer optics subsystem, and describes the spectrometer optical design. The optical subsystem performance is shown in terms of spectral modulation transfer functions, radial energy distributions, and system transmission at selected wavelengths for the four spectrometers. An outline of the spectrometer alignment is included.

Macenka, Steven A.↗

Imaging systems for the delineation of spectral properties of geologic materials in the visible and near-infrared

The current status of imaging systems for the identification of the spectral properties of geologic minerals in the visible and near infrared ranges is reviewed. The technical characteristics of the most important instruments are given, including the MSS and TM, the Airborne Imaging Spectrometer, (AIS) the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), and the Shuttle Imaging Spectrometer Experiment (SISEX). It is pointed out that none of the current systems have sufficient spectral resolution to identify mineralogy on the basis of absorption characteristics in the visible, near-infrared or shortwave-infrared bands. The development of new systems with higher spectral resolution is discussed.

Marsh, S. E.↗

Evaluation of Airborne Visible/Infrared Imaging Spectrometer Data of the Mountain Pass, California carbonatite complex

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data of the Mountain Pass, California carbonatite complex were examined to evaluate the AVIRIS instrument performance and to explore alternative methods of data calibration. Although signal-to-noise estimates derived from the data indicated that the A, B, and C spectrometers generally met the original instrument design objectives, the S/N performance of the D spectrometer was below expectations. Signal-to-noise values of 20 to 1 or lower were typical of the D spectrometer and several detectors in the D spectrometer array were shown to have poor electronic stability. The AVIRIS data also exhibited periodic noise, and were occasionally subject to abrupt dark current offsets. Despite these limitations, a number of mineral absorption bands, including CO3, Al-OH, and unusual rare earth element bands, were observed for mine areas near the main carbonatite body. To discern these bands, two different calibration procedures were applied to remove atmospheric and solar components from the remote sensing data. The two procedures, referred to as the single spectrum and the flat field calibration methods gave distinctly different results. In principle, the single spectrum method should be more accurate; however, additional fieldwork is needed to rigorously determine the degree of calibration success.

Crowley, James↗

Calibration Of Airborne Visible/IR Imaging Spectrometer

Paper describes laboratory spectral and radiometric calibration of Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) applied to all AVIRIS science data collected in 1987. Describes instrumentation and procedures used and demonstrates that calibration accuracy achieved exceeds design requirements. Developed for use in remote-sensing studies in such disciplines as botany, geology, hydrology, and oceanography.

Vane, G. A.↗

Mapping alteration in the Goldfield Mining District, Nevada, with the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

Analysis of the data acquired by the Airborne Visible/IR Imaging Spectrometer over the Goldfield Mining District, Nevada, demonstrates the unique capabilities of high resolution imaging spectrometers for alteration mapping and identification of mineralogy. The study focuses on the 2-2.45 micron window, as alteration minerals of interest have their distinctive spectral reflectance features in this region. An attempt was made to map the spatial distribution of the individual minerals and produce a mixture maps showing their relative abundance on a pixel-by-pixel basis, focussing on selected subareas. Software and SNR performances limited success in detailed mapping.

Carrere, Veronique↗

Recent Improvements to the Airborne Visible/Infrared Imaging Spectrometer (AVRIS)

Several improvements have been made to the Airborne Visible/Infrared Imaging Spectrometer (AVRIS) since 1994--new focal plane arrays, a new analog and digital chain and an onboard calibration lamp controlled by radiance feedback. These changes increased the signal-to- noise ratio by 2 to 3 times, eliminated noise spikes and the need for spectral sampling, and greatly reduced dark-current noise.

AVRIS improvements spectrometer↗

Compensation for the Atmosphere in Radiance Measured by the Airborne Visible/Infrared Imaging Spectrometer and Applications to an Advanced Land Remote Sensing System

The Airborne Visible/Infrared Imaging Spectrometer measures spatial images of the total upwelling spectral radiance from 400 to 2500 nm through 10 nm spectral channels. Quantitative research and application objectives for surface investigations require conversion of the measured radiance to surface reflectance or surface leaving radiance. To calculate apparent surface reflectance an estimation of atmospheric water vapor abundance, cirrus cloud effects, surface pressure elevation and aerosol optical depth is also required. Algorithms for the estimation of these parameters from the AVIRIS data themselves are described. Based upon these determined atmospheric parameters we show an example of the calculation of apparent surface reflectance from the AVIRIS-measured radiance using a radiative transfer code.

Airborne Visible/Infrared Imaging Spectrometer AVI↗

Quantitative investigations of geologic surfaces utilizing airborne visible/infrared imaging spectrometer (AVIRIS) and polarimetric radar (AIRSAR) data for Death Valley, California

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) and polarimetric radar (AIRSAR) data were collected over Death Valley, California, USA, in September 1989. These two data sets were used to quantitatively characterize both the mineralogy and surface structure of the valley floor. Field mapping and characterization of the salt flats across the valley identified 16 separate units. The AVIRIS data were calibrated using the 'empirical line' method, and spectra extracted for the 16 units. A water vapor map was generated from the AVIRIS data and showed spatial variations in its distribution due to evaporation of surface water. Unmixing of the 16 spectral units produced maps of endmember abundance.

Kierein-Young, Kathryn S.↗

Use of high spectral resolution airborne visible/infrared imaging spectrometer data for geologic mapping: An overview

Specific examples of the use of AVIRIS (Airborne Visible/Infrared Imaging Spectrometer) high spectral resolution data for mapping, alteration related to ore deposition and to hydrocarbon seepage, and alluvial fans are presented. Correction for atmospheric effects was performed using flat field correction, log residuals, and radiative transfer modeling. Minerals of interest (alunite, kaolinite, gypsum, carbonate iron oxides, etc.) were mapped based upon the wavelength position, depth and width of characteristic absorption features. Results were checked by comparing to existing maps, results from other sensors (Thematic Mapper (TM) and TIMS (Thermal Infrared Multispectral Scanner)), and laboratory spectra of samples collected in the field. Alteration minerals were identified and mapped. The signal to noise ratio of acquired AVIRIS data, long to 2.0 microns, was insufficient to map minerals of interest.

Carrere, Veronique↗

Multispectral remote sensing as stratigraphic and structural tool, Wind River Basin and Big Horn Basin areas, Wyoming

The use of Landsat TM, Airborne Imaging Spectrometer, and airborne Thermal IR Multispectral Scanner data in the geological evaluation of two sites in central Wyoming is described and illustrated with diagrams, maps, photographs, sample images, and tables of numerical data. The value of the remotely sensed information on the areal variation of attitude, sequence, thickness, and lithology of exposed strata is demonstrated; details of the data analysis are given; and the specialized software packages employed are briefly characterized.

Lang, Harold R.↗

Atmospheric water mapping with the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), Mountain Pass, California

Observations are given of the spatial variation of atmospheric precipitable water using the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) over a desert area in eastern California, derived using a band ratio method and the 940 nm atmospheric water band and 870 nm continuum radiances. The ratios yield total path water from curves of growth supplied by the LOWTRAN 7 atmospheric model. An independent validation of the AVIRIS-derived column abundance at a point is supplied by a spectral hygrometer calibrated with respect to radiosonde observations. Water values conform to topography and fall off with surface elevation. The edge of the water vapor boundary layer defined by topography is thought to have been recovered. The ratio method yields column abundance estimates of good precision and high spatial resolution.

Conel, James E.↗

Comparison of laboratory calibrations of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) at the beginning and end of the first flight season

Spectral and radiometric calibrations of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) were performed in the laboratory in June and November, 1987, at the beginning and end of the first flight season. Those calibrations are described along with changes in instrument characteristics that occurred during the flight season as a result of factors such as detachment of the optical fibers to two of the four AVIRIS spectrometers, degradation in the optical alignment of the spectrometers due to thermally-induced and mechanical warpage, and breakage of a thermal blocking filter in one of the spectrometers. These factors caused loss of signal in three spectrometers, loss of spectral resolution in two spectrometers, and added uncertainty in the radiometry of AVIRIS. Results from in-flight assessment of the laboratory calibrations are presented. A discussion is presented of improvements made to the instrument since the end of the first flight season and plans for the future. Improvements include: (1) a new thermal control system for stabilizing spectrometer temperatures, (2) kinematic mounting of the spectrometers to the instrument rack, and (3) new epoxy for attaching the optical fibers inside their mounting tubes.

Vane, Gregg↗

Hyperspectral data analysis for estimation of foliar biochemical content along the Oregon transect

The NASA Oregon Transect Ecosystem Research (OTTER) project completed a data acquisition phase. Data were acquired with several airborne imaging spectrometers. Included were the Airborne Visible and Infrared Imaging Spectrometer (AVIRIS) aboard the ER-2, the Advanced Solidstate Array Spectrometer (ASAS) aboard the C-130, and the Fluorescence Line Imager (FLI) and Compact Airborne Spectrographic Imager (CASI), both aboard light aircraft. In addition, Spectron visible and near-infrared data were acquired in transects across study areas from a low-altitude ultralight craft. Sunphotometer data were taken approximately coincident with each overflight for atmospheric correction of the aircraft data.

Johnson, Lee F.↗

Science Measurement Requirements for Imaging Spectrometers from Airborne to Spaceborne

This slide presentation reviews the objectives of the work to create imaging spectrometers. The science objectives are to remotely determine the properties of the surface and atmosphere (physics, chemistry and biology) revealed by the interaction of electromagnetic energy with matter via spectroscopy. It presents a review the understanding of spectral, radiometric and spatial science measurement requirements for imaging spectrometers based upon science research results from past and current airborne and spaceborne instruments. It also examines the future requirements that will enable the next level of imaging spectroscopy science.

radiometric requirements↗

Geometric and radiometric preprocessing of airborne visible/infrared imaging spectrometer (AVIRIS) data in rugged terrain for quantitative data analysis

A geocoding procedure for remotely sensed data of airborne systems in rugged terrain is affected by several factors: buffeting of the aircraft by turbulence, variations in ground speed, changes in altitude, attitude variations, and surface topography. The current investigation was carried out with an Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) scene of central Switzerland (Rigi) from NASA's Multi Aircraft Campaign (MAC) in Europe (1991). The parametric approach reconstructs for every pixel the observation geometry based on the flight line, aircraft attitude, and surface topography. To utilize the data for analysis of materials on the surface, the AVIRIS data are corrected to apparent reflectance using algorithms based on MODTRAN (moderate resolution transfer code).

Meyer, Peter↗

Use of the Airborne Visible/Infrared Imaging Spectrometer to Calibrate the Optical Sensor on Board the Japanese Earth Resources Satellite-1

In this paper, we describe an experiment to calibrate the Optical Sensor on board the Japanese Earth Resources Satellite-1 with data acquired by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). This experiment establishes the suitability of AVIRIS for the calibration of spaceborne sensors in the 400 to 2500 nm spectral region.

spaceborne↗