Search NASA⌕ Search

SEARCH · Search NASA

Results for “Alternating current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Probing radiation damage by alternated current conductivity as a method to characterize electron hopping conduction in DNA molecules

Analysis of AC electrical conductivity of deoxyribonucleic acid (DNA) thin films, irradiated with ultraviolet (UV) light, revealed that electrical conduction arises from DNA chain electron hopping between base-pairs and phosphate groups. The hopping distance calculated from correlated barrier hopping model equals the distance between DNA base-pairs, which is consistent with the loss of conductivity with irradiation time arising from a decrease in phosphates groups. In the high frequency regime, at a given frequency, real part of conductivity strongly depends on irradiation time particularly for low dose levels suggesting the use of DNA based films for UV radiation sensors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical properties of the atmospheric pressure helium plasma jet generated by alternative current (a.c.) power supply

In this work, an atmospheric pressure plasma jet (APPJ) was produced to generate cold flowing post-discharge plasma of pure helium gas. The main aim of this study was to generate cold flowing APPJ of pure helium gas and to determine how their optical emission spectrum change influences varying different flow rates. Lengths of early, middle, and late post-discharge plasma (jet) regions and their fluctuations were determined, respectively. Then, ignition condition dependence of the post-discharge plasma for flow rate was specified at a constant voltage. Spectroscopic studies of an atmospheric pressure plasma jet of helium were presented via analyzing OH, N{sub 2}, N{sub 2}{sup +}, oxygen, and helium intensities for various flow rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

What is the Impact of Utility Demand Charges on an Alternating Current Level 2 Elective Vehicle Supply Equipment Host?

The EVSE delivered by The EV Project included both residential and non-residential units. Approximately 4,000 non-residential ACL2 EVSE were installed in workplace environments, fleet applications and publicly accessible locations near retail centers, parking lots, and similar locations. The Blink ACL2 utilized in The EV Project is capable of charging at up to 7.2 kW power, although most vehicles in The EV Project charged at about 3.7 kW. This power can be a significant additional electrical load for the charging site host. This concern becomes greater when several EVSE are in operation on a site at the same time. Many electric utilities include maximum power demand as part of their commercial rate structure. The demand charge incurred by a commercial customer is related to the peak power used during a monthly billing cycle. This is in contrast to the total energy usage that is the more familiar utility charge seen for residential service. A demand charge is typically calculated based on the highest average power level over a 15 minute period during the monthly billing cycle and is not a cumulative-type charge. One objective of The EV Project was to elucidate the motivations and hindrances to potential site hosts of non-residential EVSE. The imposition of electric utility demand charges represents such a potential hindrance. This subject was introduced in the paper: DC Fast Charge - Demand Charge Reduction1, specifically dealing with DC Fast Chargers. The concept remains relevant to ACL2 EVSE, especially when several EVSE are deployed at the same site, which occurred frequently in the EV Project. In fact, the average number of ACL2 EVSE per site was 2.58 and varied by market from 1.79 to 3.45 per site. This paper identifies the impact of demand charges on non-residential ACL2 hosts in The EV Project

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Best Practices Utilized by The EV Project for Non-Residential Alternating Current Level 2 ?Electric Vehicle Supply Equipment Infrastructure Planning

The lack of public charging infrastructure for plug-in electric vehicles (PEVs) has been identified as a barrier to their widespread adoption. Federal and state grants have been awarded to promote public charging and encourage retail businesses to install charging infrastructure. A common question for charger installations is, “Where should the chargers be placed?” One of the objectives of the EV Project was to study the interaction of PEV drivers with the public infrastructure, so The EV Project attempted to develop a method to determine where EVSE should be placed. In the early stages of PEV sales in local markets, the options for siting publicly accessible EVSE were: • Plan locations associated with key attraction sites where PEV parking is anticipated • Directly solicit retail and public charging hosts for widespread placement • Ask the PEV drivers who were early adopters where they want public infrastructure • Identify sites near known high traffic areas

33 ADVANCED PROPULSION SYSTEMS↗

Characterize Clustering of Non-Residential Alternating Current Level 2 Electric Vehicle Supply Equipment

The EVSE deployed by The EV Project included both residential and non-residential units. Approximately 4,000 non-residential AC Level 2 (ACL2) EVSE were installed in workplace environments, fleet applications and those publicly accessible located near retail centers, parking lots, and similar locations. The Blink ACL2 is capable of charging at up to 7.2 kW power, although most vehicles in The EV Project charged at about 3.7 kW. The charge rate and energy consumed to recharge the battery are determined by the plug-in electric vehicle’s (PEV’s) on-board battery management system. The impact on the local electrical grid becomes greater when several EVSE are charging PEVs on a site at the same time, or when several commercial EVSE sites are geographically close and charging simultaneously. This may place stresses on the local power transformer providing energy to these sites. What insight can The EV Project data provide in characterizing the effect of several geographically close non-residential EVSE?

33 ADVANCED PROPULSION SYSTEMS↗

Methods, systems and apparatus for controlling operation of two alternating current (AC) machines

A system is provided for controlling two AC machines. The system comprises a DC input voltage source that provides a DC input voltage, a voltage boost command control module (VBCCM), a five-phase PWM inverter module coupled to the two AC machines, and a boost converter coupled to the inverter module and the DC input voltage source. The boost converter is designed to supply a new DC input voltage to the inverter module having a value that is greater than or equal to a value of the DC input voltage. The VBCCM generates a boost command signal (BCS) based on modulation indexes from the two AC machines. The BCS controls the boost converter such that the boost converter generates the new DC input voltage in response to the BCS. When the two AC machines require additional voltage that exceeds the DC input voltage required to meet a combined target mechanical power required by the two AC machines, the BCS controls the boost converter to drive the new DC input voltage generated by the boost converter to a value greater than the DC input voltage.

47 OTHER INSTRUMENTATION↗

Construction and evaluation of photovoltaic power generation and power storage system using SiC field-effect transistor inverter

A power storage system using spherical silicon (Si) solar cells, maximum power point tracking charge controller, lithium-ion battery and a direct current-alternating current (DC-AC) inverter was constructed. Performance evaluation of the DC-AC inverter was carried out, and the DC-AC conversion efficiencies of the SiC field-effect transistor (FET) inverter was improved compared with those of the ordinary Si-FET based inverter.

14 SOLAR ENERGY↗

Comparative study of 0° X-cut and Y + 36°-cut lithium niobate high-voltage sensing

A comparison study between Y + 36° and 0° X-cut lithium niobate (LiNbO{sub 3}) was performed to evaluate the influence of crystal cut on the acoustic propagation to realize a piezoelectric high-voltage sensor. The acoustic time-of-flight for each crystal cut was measured when applying direct current (DC), alternating current (AC), and pulsed voltages. Results show that the voltage-induced shift in the acoustic wave propagation time scaled quadratically with voltage for DC and AC voltages applied to X-cut crystals. For the Y + 36° crystal, the voltage-induced shift scales linearly with DC voltages and quadratically with AC voltages. When applying 5 μs voltage pulses to both crystals, the voltage-induced shift scaled linearly with voltage. For the Y + 36° cut, the voltage-induced shift from applying DC voltages ranged from 10 to 54 ps and 35 to 778 ps for AC voltages at 640 V over the frequency range of 100 Hz–100 kHz. Using the same conditions as the Y + 36° cut, the 0° X-cut crystal sensed a shift of 10–273 ps for DC voltages and 189–813 ps for AC voltage application. For 5 μs voltage pulses, the 0° X-cut crystal sensed a voltage induced shift of 0.250–2 ns and the Y + 36°-cut crystal sensed a time shift of 0.115–1.6 ns. This suggests a frequency sensitive response to voltage where the influence of the crystal cut was not a significant contributor under DC, AC, or pulsed voltage conditions. The measured DC data were compared to a 1-D impedance matrix model where the predicted incremental length changed as a function of voltage. When the voltage source error was eliminated through physical modeling from the uncertainty budget, the combined uncertainty of the sensor (within a 95% confidence interval) decreased to 0.0033% using a Y + 36°-cut crystal and 0.0032% using an X-cut crystal for all the voltage conditions used in this experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrical transport behavior of nonstoichiometric magnesium-zinc ferrite

This paper presents the direct current conductivity, alternate current conductivity and dielectric properties of nonstoichiometric magnesium-zinc ferrite below room temperature. The frequency exponent (s) of conductivity shows an anomalous temperature dependency. The magnitude of the temperature exponent (n) of dielectric permittivity strongly depends on frequency and its value decreases with increasing frequency. The grain boundary contribution is dominating over the grain contribution in conduction process and the temperature dependence of resistance due to grain and grain boundary contribution exhibits two activation regions. The ferrite shows positive alternating current magnetoconductivity. The solid state processing technique was used for the preparation of nanocrystalline ferrite powder from oxides of magnesium, zinc and iron. The X-ray diffraction methods were used in determining the structure and composition of obtained ferrite, while multimeter, impedance analyzer, liquid nitrogen cryostat and electromagnet were used in the study of conducting and dielectric properties of ferrite.

36 MATERIALS SCIENCE↗

DC-AC electrical transformer

An apparatus and corresponding systems and methods for managing electric power, particularly a transformer system and method, and more specifically a transformer for transforming direct current to alternating current. An example apparatus includes a chamber configured to contain plasma. The apparatus includes input electrodes disposed at least partially within the chamber, and configured to receive direct current input into the chamber. The input electrodes are configured to cause the input direct current to induce motion in the plasma. Motion induced in the plasma transforms current flowing there-through. Output electrodes extend from the chamber, which output electrodes may rotated in a controlled manner. The output electrodes conduct a three or one phase alternating current, from the induced motion in the plasma, for delivery from the chamber.

42 ENGINEERING↗

Evaluation of Delamination of X80 Pipeline Steel Coating Under Alternating Stray Current Via Scanning Electrochemical Microscopy

The delamination of epoxy coating on X80 pipeline steel was evaluated under various stray alternating current (AC) interferences (0-300 A/m{sup 2}). Qualitative and quantitative analyses were carried out using scanning electrochemical microscopy (SECM), electrochemical impedance spectroscopy (EIS), and three-dimensional digital microscopy. The results show that the SECM current is directly proportional to the soaking time and applied current density. The variation in SECM current curve shape indicates the delamination distance of epoxy coatings at the defect area. The depths of corrosion pits at 50, 100, and 300 A/m{sup 2} stray currents were 140, 160, and 240 μm, respectively. The corrosion pits also became wider with increasing current densities. With increasing stray AC densities, both the coating delamination and pit depth became more severe at the same soaking time. The EIS results show that the change in impedance was not significant without stray current, whereas the impedance first decreased and then increased when stray current was applied. These results are consistent with the SECM measurements.

36 MATERIALS SCIENCE↗