Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ankle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Measurement of the depth of maximum of air-shower profiles with energies between 10 18.5 and 10 20 eV using the surface detector of the Pierre Auger Observatory and deep learning

We report an investigation of the mass composition of cosmic rays with energies from 3 to 100 EeV ( 1 EeV = 10 18 eV ) using the distributions of the depth of shower maximum X max . The analysis relies on ∼ 50 , 000 events recorded by the surface detector of the Pierre Auger Observatory and a deep-learning-based reconstruction algorithm. Above energies of 5 EeV, the dataset offers a 10-fold increase in statistics with respect to fluorescence measurements at the Observatory. After cross-calibration using the fluorescence detector, this enables the first measurement of the evolution of the mean and the standard deviation of the X max distributions up to 100 EeV. Our findings are threefold: (i) The evolution of the mean logarithmic mass toward a heavier composition with increasing energy can be confirmed and is extended to 100 EeV. (ii) The evolution of the fluctuations of X max toward a heavier and purer composition with increasing energy can be confirmed with high statistics. We report a rather heavy composition and small fluctuations in X max at the highest energies. (iii) We find indications for a characteristic structure beyond a constant change in the mean logarithmic mass, featuring three breaks that are observed in proximity to the ankle, instep, and suppression features in the energy spectrum. Published by the American Physical Society 2025

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inference of the Mass Composition of Cosmic Rays with Energies from 10 18.5 to 10 20 eV Using the Pierre Auger Observatory and Deep Learning

We present measurements of the atmospheric depth of the shower maximum X max , inferred for the first time on an event-by-event level using the surface detector of the Pierre Auger Observatory. Using deep learning, we were able to extend measurements of the X max distributions up to energies of 100 EeV ( 10 20 eV ), not yet revealed by current measurements, providing new insights into the mass composition of cosmic rays at extreme energies. Gaining a 10-fold increase in statistics compared to the fluorescence detector data, we find evidence that the rate of change of the average X max with the logarithm of energy features three breaks at 6.5 ± 0.6 ( stat ) ± 1 ( syst ) EeV , 11 ± 2 ( stat ) ± 1 ( syst ) EeV , and 31 ± 5 ( stat ) ± 3 ( syst ) EeV , in the vicinity to the three prominent features (ankle, instep, suppression) of the cosmic-ray flux. The energy evolution of the mean and standard deviation of the measured X max distributions indicates that the mass composition becomes increasingly heavier and purer, thus being incompatible with a large fraction of light nuclei between 50 and 100 EeV. Published by the American Physical Society 2025

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compliant Intramedullary Stems for Joint Reconstruction

The longevity of current joint replacements is limited by aseptic loosening, which is the primary cause of non-infectious failure for hip, knee, and ankle arthroplasty. Aseptic loosening is typically caused either by osteolysis from particulate wear, or by high shear stresses at the bone-implant interface from over-constraint. Our objective was to demonstrate feasibility of a compliant intramedullary stem that eliminates over-constraint without generating particulate wear. The compliant stem is built around a compliant mechanism that permits rotation about a single axis. We first established several models to understand the relationship between mechanism geometry and implant performance under a given angular displacement and compressive load. We then used a neural network to identify a design space of geometries that would support an expected 100-year fatigue life inside the body. We additively manufactured one representative mechanism for each of three anatomic locations, and evaluated these prototypes on a KR-210 robot. The neural network predicts maximum stress and torsional stiffness with 2.69% and 4.08% error respectively, relative to finite element analysis data. We identified feasible design spaces for all three of the anatomic locations. Simulated peak stresses for the three stem prototypes were below the fatigue limit. Benchtop performance of all three prototypes was within design specifications. Our results demonstrate the feasibility of designing patient- and joint-specific compliant stems that address the root causes of aseptic loosening. Guided by these results, we expect the use of compliant intramedullary stems in joint reconstruction technology to increase implant lifetime.

60 APPLIED LIFE SCIENCES↗

Insights into posttranslational regulation of skeletal muscle contractile function by the acetyltransferases, p300 and CBP

Here, mice with skeletal muscle-specific and inducible double knockout of the lysine acetyltransferases, p300 (E1A binding protein p300) and CBP (cAMP-response element-binding protein binding protein), referred to as i-mPCKO, demonstrate a dramatic loss of contractile function in skeletal muscle and ultimately die within 7 days. Given that many proteins involved in ATP generation and cross-bridge cycling are acetylated, we investigated whether these processes are dysregulated in skeletal muscle from i-mPCKO mice and, thus, whether they could underlie the rapid loss of muscle contractile function. Just 4–5 days after inducing knockout of p300 and CBP in skeletal muscle from adult i-mPCKO mice, there was ~90% reduction in ex vivo contractile function in the extensor digitorum longus (EDL) and a ~65% reduction in in vivo ankle dorsiflexion torque, as compared with wild type (WT; i.e., Cre negative) littermates. Despite this profound loss of contractile force in i-mPCKO mice, there were no genotype-driven differences in fatigability during repeated contractions, nor were there genotype differences in mitochondrial-specific pathway enrichment of the proteome, intermyofibrillar mitochondrial volume, or mitochondrial respiratory function. As it relates to cross-bridge cycling, remarkably, the overt loss of contractile function in i-mPCKO muscle was reversed in permeabilized fibers supplied with exogenous Ca 2+ and ATP, with active tension being similar between i-mPCKO and WT mice, regardless of Ca 2+ concentration. Actin-myosin motility was also similar in skeletal muscle from i-mPCKO and WT mice. In conclusion, neither mitochondrial abundance/function, nor actomyosin cross-bridge cycling, are the underlying driver of contractile dysfunction in i-mPCKO mice.

59 BASIC BIOLOGICAL SCIENCES↗

Spectral Properties of Globally Distributed ENA Fluxes across Diverse Regions of the Heliosphere

This study analyzes energetic neutral atom (ENA) spectral properties across distinct regions of globally distributed flux (GDF) sky maps, using Interstellar Boundary Explorer data from a full solar cycle, corrected for time dispersion. By time-shifting the data to the heliosheath using GDF source distances from D. B. Reisenfeld et al., we achieve a more accurate representation of heliosheath GDF energy spectra. We quantify ENA spectral characteristics, heliosheath line-of-sight-integrated proton pressure, and heliosheath proton temperature, comparing these to solar wind properties at 1 au and interplanetary scintillation-derived solar wind data. Our findings show that the spectral index is generally anticorrelated with heliosheath proton temperature and pressure, except in the central tail, where a partial positive correlation is observed. The lowest spectral index values occur when high-latitude heliosheath regions are dominated by fast solar wind from polar coronal holes. The south pole exhibits the flattest energy spectra due to plasma heating from both fast solar wind and a late-2014 pressure pulse. The central tail shows shorter variability (5–6 yr) for spectral index and heliosheath proton temperature, while proton pressure follows the 11 yr solar cycle. Most spectral shapes exhibit a “knee” distribution, peaking during solar maximum, with an “ankle” shape observed only at the south pole during solar cycle transitions. Asymmetry in proton pressure in the lobes is driven by the draping effect of the local interstellar magnetic field. This study provides insights into the energetic properties of GDF across the heliosphere, enhancing our understanding of the heliospheric environment.

79 ASTRONOMY AND ASTROPHYSICS↗

A model describing vestibular detection of body sway motion.

An experimental technique was developed which facilitated the formulation of a quantitative model describing vestibular detection of body sway motion in a postural response mode. All cues, except vestibular ones, which gave a subject an indication that he was beginning to sway, were eliminated using a specially designed two-degree-of-freedom platform; body sway was then induced and resulting compensatory responses at the ankle joints measured. Hybrid simulation compared the experimental results with models of the semicircular canals and utricular otolith receptors. Dynamic characteristics of the resulting canal model compared closely with characteristics of models which describe eye movement and subjective responses to body rotational motions. The average threshold level, in the postural response mode, however, was considerably lower. Analysis indicated that the otoliths probably play no role in the initial detection of body sway motion.

Nashner, L. M.↗

Further observations on the relationship of EMG and muscle force

Human skeletal muscle may be regarded as an electro-mechanical transducer. Its physiological input is a neural signal originating at the alpha motoneurons in the spinal cord and its output is force and muscle contraction, these both being dependent on the external load. Some experimental data taken during voluntary efforts around the ankle joint and by direct electrical stimulation of the nerve are described. Some of these experiments are simulated by an analog model, the input of which is recorded physiological soleus muscle EMG. The output is simulated foot torque. Limitations of a linear model and effect of some nonlinearities are discussed.

Agarwal, G. C.↗

Effects of low frequency vibration of a limb

Low frequency oscillations were applied on the ankle joint in plantarflexion/dorsiflexion rotation using a torque motor. The torque, the angular rotation and the evoked electromyogram from the gastronemius soleus and the anterior tibial muscles were recorded. Significant nonlinearities were observed in the angular rotation from 8 to 12 Hz. The following methods are used for data analysis: (1) Two cycle averaged response; (2) Fourier transform; and (3) Fourier analysis at the driving frequency. Important observations are: (1) resonance near 6 to 8 Hz; (2) slowly increasing amplitudes of oscillation near resonance; (3) self sustaining oscillations after the motor is turned off, particularly in the fatigued limb; and (4) distortion of angular rotation during which there are spontaneous recurrences of oscillation at the driving frequency.

Agarwal, G. C.↗

Development of restraint material and tucked fabric joints

A study was conducted to evaluate and select a suitable restraint material for the exterior of space suits pressurized to 4.0 PSID for normal operations, and to develop and improve tucked fabric joints for motions associated with the human shoulder, elbow, knee, waist, hip, ankle, and wrist. The many attributes of the end items are summarized to include structural integrity, simplicity, low maintenance, lightweight, high durability, low elongation, full range mobility, long life, and resistance to degradation in the operational environment.

Mcmullen, J. M.↗

Walking boot assembly

A walking boot assembly particularly suited for use with a positively pressurized spacesuit is presented. A bootie adapted to be secured to the foot of a wearer, an hermetically sealed boot for receiving the bootie having a walking sole, an inner sole, and an upper portion adapted to be attached to an ankle joint of a spacesuit, are also described.

Vykukal, H. C.↗

Load compensating reactions to perturbations at wrist joint in normal man

The electromyographic responses to step torque loads were studied in flexors and extensors at the human wrist. Based on temporal bursting patterns and functional behavior, the response was divided into four temporal components. Two early components, the myotatic (30-60 ms) late myotatic (60-120 ms) appears to be reflex response. The third postmyotatic component (120-200 ms) appear to be a triggered reaction, preceeding the fourth, stabilizing component (200-400 ms). A comparison of response at the wrist with similar data at the ankle provides the basis for a generalized classification of the response in various muscles to torque step perturbations.

Jaeger, R. J.↗

Non-steady State Effects in EHL

A number of lubricated machine elements are subjected to cyclic variations of load and speed, particularly in reciprocating machinery. It is well known that squeeze-film action plays an important role in preserving satisfactory lubricating films in many cases in which the entraining velocities fall to zero during each cycle, as in the reciprocating seal and synovial joints. The essential features of combined 'entraining' and 'normal' motion are described for both hydrodynamic and elastohydrodynamic conditions. It is shown that very small squeeze-film velocities (W), or order (h(sub o)/l)U, can lead to substantial hydrodynamic action. A brief review of previous studies of squeeze-film lubrication between spheres or cylinders and a plane is followed by reference to a recent analysis of ankle joint lubrication. It is then shown that elastohydrodynamic lubrication might be encountered in the conjunction between a piston ring and cylinder liner and that in such cases combined entraining and squeeze-film action is important. Analysis of a 2-stroke Diesel engine shows that variations in squeeze-film velocity throughout the conjunction, associated with time rates of change of elastic deformation, must be considered in a full elastohydrodynamic lubrication analysis.

Duncan Dowson↗

Glucocorticoid sensitivity, disuse, and the regulation of muscle mass

A new noninvasive immobilization procedure to be used on rats has been developed to study immobilization-induced muscle hypersensitivity to normal glucocorticoid concentration, subsequent muscle atrophy, and atrophy recovery. The immobilization procedure involves encasing the hind limb in a light-weight plasticlike cast (10 percent the usual plaster weight), completely resistant to animal gnawing. The effects of right-angle immobilization of the ankle on the slow fiber soleus, and the fast fiber extensor digitorum longus, resemble the effects of weightlessness. The increased concentration of glucocorticoid receptor sites in immobilized and denervated muscle is discussed, along with the chronic loss of muscle mass that occurs in practically all dystrophies. It is concluded that lack of mechanical work in a zero gravity environment is a major cause of glucocorticoid hypersensitivity in the body's musculature.

Almon, R. R.↗

The cosmic ray spectrum above 10(17) eV

The final analysis of the data obtained by the Sydney University Giant Airshower Recorder (SUGAR) is presented. The data has been reanalysed to take into account the effects of afterpulsing in the photomultiplier tubes. Event data was used to produce a spectrum of equivalent vertical muon number and from this a model dependent primary energy spectrum was obtained. These spectra show good evidence for the Ankle: a flattening at 10(19) eV. There is no sign of the cut-off which would be expected from the effects of the universal black body radiation.

Winn, M. M.↗

M.I.T./Canadian vestibular experiments on the Spacelab-1 mission. V - Postural responses following exposure to weightlessness

The four science crewmembers of Spacelab-1 were tested for postural control before and after a 10 day mission in weightlessness. Previous reports have shown changes in astronaut postural behavior following a return to earth's 1-g field. This study was designed to identify changes in EMG latency and amplitudes that might explain the instabilities observed post-flight. Erect posture was tested having the subject stand on a pneumatically driven posture platform which pitched rapidly and unexpectedly about the ankles causing dorsi- and plantarflexion. Electromyographic (EMG) activity from the tibialis anterior and the gastrocnemius-soleus muscles was measured during eyes open and eyes closed trials. The early (pre 500 ms) EMG response characteristics (latency, amplitude) in response to a disturbance in the posture of the subject were apparently unchanged by the 10 days of weightlessness. However, the late (post 500 ms) response showed higher amplitudes than was found pre-flight. General postural control was quantitatively measured pre- and post-flight by a 'sharpened Romberg Rails test'. This test showed decrements in standing stability with eyes closed for several days post-flight.

Kenyon, R. V.↗

Proposal for a zero-gravity toilet facility for the space station

This proposed toilet facility has a straightforward design. It has few moving parts and is easily maintained. Air and water flow provide sanitary movement of the waste. The toilet's chambers are coated with Teflon which, along with the water flow, makes it self-cleaning. An added disinfectant called Betadiene kills any bacteria that may form on the chamber walls. The chair is contoured to take into account the neutral body position and the necessary strain position for defecation. Restraints at the ankles, knees, and midsection hold the body in the chair. The waste is stored in discs of Gortex material which are inside a replaceable storage chamber. This chamber can be removed, capped and stored until eventual return to earth.

Fleri, Edgar L., Jr.↗

Spaceflight and growth effects on muscle fibers in the rhesus monkey

The effect of a 14-day spaceflight onboard Cosmos 2044 on selected morphological and metabolic properties of single muscle fibers was investigated in a nonhuman primate, Macaca mulatta. It is concluded that the 14-day spaceflight had little impact on fiber size in the soleus (S) and medial gastrocnemius (MG) muscles, whereas it appeared to be a slight decrease in sized in the tibialis anterior (TA). The mean fiber size in the postflight biopsies increased relative to preflight values. The mean fiber succinate dehydrogenase activity was found to decrease in the MG, whereas there was no apparent effect of spaceflight on the s and ta muscles. The differences in response of the S, MG, and TA to spaceflight in monkeys vs rats may be related to a species responsiveness to spaceflight, the manner in which the animals were restrained, and/or the possibility that the ankle musculature was able to function against a load while in space.

Bodine-Fowler, Sue C.↗

Changes in leg volume during microgravity simulation

Little published information exists regarding the magnitude and time course of cephalad fluid shift resulting from microgravity simulations. Six subjects were exposed to 150 min each at horizontal bed rest, 6-deg head-down tilt, and horizontal water immersion. Fluid shift was estimated by calculating leg volumes from eight serial girth measurements from groin to ankle before, during, and after exposure. Results were compared with data from the first 3 h of spacecraft. By the end of exposure, total leg volume for the six subjects decreased by 2.6 +/- 0.8 percent, 1.7 +/- 1.2 percent, and 4.0 +/- 1.6 percent for horizontal, head-down, and immersion, respectively. Changes had plateaued for horizontal and head-down and had slowed for immersion. Relatively more fluid was lost from the lower leg than the thigh for all three conditions, particularly head-down. During the first 3 h of spaceflight, total leg volume decreased by 8.6 percent, and relatively more fluid was lost from the thigh than the lower leg. The difference in volume changes in microgravity and simulated microgravity may be caused by the small transverse pressures still present in ground-based simulations and the extremely nonlinear compliance of tissue.

Thornton, William E.↗