Search NASA⌕ Search

SEARCH · Search NASA

Results for “Argon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A novel liquid argon purity monitor based on 207 Bi

A novel liquid argon purity monitor based on a 207 Bi radioactive source, emitting monochromatic internal-conversion electrons, is presented. This new monitor allows for a very precise and fast measurement of the electronegative impurities concentration in liquid argon. It can be operated continuously in liquid argon TPC experiments without interfering with the main detector operation. Different drift lengths can be assembled for the proposed device, to assess a large range of liquid argon purities while minimizing systematic uncertainties. Two prototypes have been built and successfully operated in dedicated test stands. The results and performance are reported.

double-phase↗

Measurement of isotopic separation of argon with the prototype of the cryogenic distillation plant Aria for dark matter searches

The Aria cryogenic distillation plant, located in Sardinia, Italy, is a key component of the DarkSide-20k experimental program for WIMP dark matter searches at the INFN Laboratori Nazionali del Gran Sasso, Italy. Aria is designed to purify the argon, extracted from underground wells in Colorado, USA, and used as the DarkSide-20k target material, to detector-grade quality. In this paper, we report the first measurement of argon isotopic separation by distillation with the 26 m tall Aria prototype. We discuss the measurement of the operating parameters of the column and the observation of the simultaneous separation of the three stable argon isotopes: ${}^{36}\hbox {Ar}$, ${}^{38}\textrm{Ar}$, and ${}^{40}\textrm{Ar}$. We also provide a detailed comparison of the experimental results with commercial process simulation software. This measurement of isotopic separation of argon is a significant achievement for the project, building on the success of the initial demonstration of isotopic separation of nitrogen using the same equipment in 2019.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Measurement of Differential Charged Current Quasielastic-like $\nu_\mu$–Argon Scattering Cross Sections In Kinematic Imbalance Variables With The MicroBooNE Detector

We report the first measurement of flux-integrated multi-differential cross sections for charged-current events with muon neutrinos scattering on argon with solely a muon and a single proton in the final state as a function of kinematic imbalance variables. The measurement was carried out using the Booster Neutrino Beam at Fermi National Accelerator Laboratory within the MicroBooNE Liquid Argon Time Projection Chamber detector with an exposure of 6.79 × 10 20 protons on target. Events were selected to enhance the contribution of charged-current mesonless interactions with one proton detected in the final state. The data discussed here are reported in terms of multidifferential cross sections in kinematic imbalance variables, which are generally sensitive to nuclear effects. The double-differential results in these variables can provide an excellent handle to disentagle specific nuclear aspects not easily isolated via single differential cross sections. Our results pave a path towards identifying regions of the phase-space where future interaction modeling development and Monte Carlo neutrino generator tuning efforts should concentrate. EVENT SELECTION Neutrino oscillation measurements aim to extract neutrino mixing angles, mass differences, the value of the chargeparity violating phase in the lepton sector, and to search for new physics beyond the Standard Model [1, 2]. For that to be achieved, an unprecedented understanding of neutrino-argon interactions is of utmost importance since a growing number of neutrino oscillation experiments employ Liquid Argon Time Projector Chamber (LArTPC) neutrino detectors [3–6]. The accuracy to which these experiments can extract neutrino oscillation parameters requires a good understanding of the neutrino energy. Experimentally, this energy is deduced from the measured kinetic energies of particles that are emitted following the neutrino interaction in the detector. The kinematic properties of such finalstate particles reflect complex dynamics due to nuclear and initial-state effects of the interaction [7]. However, certain categories of nuclear effects can be isolated by variables built specifically to characterize the degeneracy between such effects [8–10]. This note reports cross sections in kinematic variables sensitive to nuclear effects using events with one detected muon with momentum 0.1 < pµ < 1.2 GeV/c, and exactly one proton with 0.3 < pp < 1 GeV/c. This signal definition includes events with any number of protons below 300 MeV/c, neutrons at any momenta, and charged pions with momentum lower than 70 MeV/c. This choice is guided by the fact that their experimental signature of correlated muon-proton pairs is fairly straightforward to reconstruct [11–22]. Such events primarily originate from chargedcurrent (CC) neutrino-nucleon quasielastic (QE) scattering interactions where the neutrino removes a single intact nucleon from the nucleus without producing any additional particles. This definition can also include contributions from interactions that lead to the production of additional particles that are absent from the final state due to nuclear effects, such as pion absorption, or have momenta that are below the experimental detection threshold.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ensuring High-Purity Liquid Argon for the LBNF FDC: Collaborative Cryogenics Research Between UNICAMP and Fermilab

Ensuring High-Purity Liquid Argon for the LBNF FDC: Collaborative Cryogenics Research Between UNICAMP and Fermilab R. Doubnik1, M. Adamowski1, F. de M. Blaszczyk1, A. Hahn1, D. Montanari1, R. Mrowca1, Z. West1, C. Adriano2, T. P.M. Alegre2, D. Correia2, A. A. B. Machado2, E. Segreto2, R. G. Gonçalves3, E. M. Assaf6, J. M. Assaf3, D. Cardoso3, M. B. Fontes4, H. Da Motta4, D. Noriler5, P. J. G. Pagliuso2. 1 Fermi National Accelerator Laboratory, PO Box 500, Batavia IL 60510, United States. 2 “Gleb Wataghin” Institute of Physics, UNICAMP, Campinas-SP, 13083-859, Brazil. 3 CPqMAE - Research Center on Advanced Materials and Energy, Federal University of São Carlos (UFSCar), São Carlos, 13565-905, Brazil. 4 The Brazilian Center for Research in Physics (CBPF), Rio de Janeiro-RJ, 22290-180, Brazil. 5 School of Chemical Engineering, UNICAMP, Campinas-SP, 13083-859, Brazil. 6 São Carlos Institute of Chemistry, University of São Paulo, São Carlos-SP, 13566-590, Brazil. Email: rdoubnik@fnal.gov Abstract. The Long-Baseline Neutrino Facility (LBNF) located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, hosts the Deep Underground Neutrino Experiment (DUNE). This experiment employs cryostats containing nearly 70,000 metric tons of high-purity liquid argon (LAr). Ensuring LAr purity is critical for achieving the required electron lifetime, which directly impacts the experiment’s signal-to-noise ratio. The Horizontal Drift (HD) detector demands an electron lifetime exceeding 3 ms within its 3.5 m drift, equivalent to less than 100 parts-per-trillion (ppt) Oxygen contamination, while the Vertical Drift (VD) detector requires over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen contamination. To mitigate Nitrogen (N2) quenching of scintillation light, N2 contamination must remain below 1 ppm, as higher levels can result in up to a 20 % loss of light. The Brazil State University of Campinas (UNICAMP) significantly contributes to LBNF FDC through the development of argon purification and regeneration systems for HD and VD cryostats. UNICAMP designed and constructed the Purification Liquid Argon Cryostat (PuLArC), a small-scale test facility holding approximately 90 liters of LAr. Tests using PuLArC demonstrated that 1.2 kg of Li-FAU zeolite could reduce N₂ contamination from 20-50 ppm to 0.1-1.0 ppm within 1-2 hours. Tests at Fermilab’s Iceberg cryostat (2,596 liters) confirmed scalability, with 3 kg of Li-FAU reducing N₂ contamination from ~5 ppm to <1 ppm over 96 hours cycles without active circulation. This presentation will detail the research methods, test setups, and results, showcasing the potential of Li-FAU as an alternative to Molecular Sieve 4A for large-scale LAr systems. This advancement enhances DUNE's precision and demonstrates the impact of international collaboration on cryogenic research.

Doubnik, Roza [Fermilab]↗

Advancing Detector R&D for High-Pressure Gaseous Argon TPCs in Precision Neutrino Physics

High-pressure gaseous argon time projection chambers (HPgTPCs) represent an emerging detector paradigm for neutrino physics, combining increased target density with the intrinsic tracking and low thresholds of gaseous detectors. This approach enables detailed reconstruction of exclusive final states, improved particle identification, and sensitivity to low-energy and rare processes — capabilities that are increasingly central to precision oscillation measurements and searches for beyond-the-Standard-Model signatures. This abstract presents an overview of ongoing detector R&D toward high-pressure gaseous argon TPC operation, with emphasis on micro-pattern gas detector (MPGD) charge amplification in argon-based mixtures. We report experimental characterization of triple-GEM structures at pressures relevant for neutrino applications, including studies of multiplication factor scaling, stability, and operational voltage envelopes across gas admixtures. Measurements performed at the TOAD and GORG test stands at Fermilab help define viable amplification and electronics noise regimes in conditions where higher density imposes stricter constraints on signal formation. These results provide essential input to the optimization of high-pressure gaseous argon detectors for future neutrino experiments, including near-detector concepts such as ND-GAr in DUNE Phase II near detector upgrade. More broadly, this program shows how dedicated detector R&D can expand the precision frontier in neutrino physics by enabling complementary reconstruction capabilities beyond conventional detectors.

McConnell, Brenna [Indiana U.] (ORCID:000900041138↗

Hadron-argon cross-section measurements in ProtoDUNE-SP

The single-phase liquid argon ProtoDUNE detector (ProtoDUNE-SP) is located at CERN’s neutrino platform facility and serves as a prototype to validate the technology for the 10-kton fiducial mass liquid argon detectors for the DUNE experiment. ProtoDUNE-SP was exposed to a variety of test-beam particles (electrons, muons, pions, kaons, and protons) towards the end of 2018 collecting data in a broad range of momenta, from 0.3 - 7 GeV/c. The results will improve the understanding of final-state interactions in neutrino-argon cross-sections. The progress of the analyses towards the cross-section measurements on argon from the test-beam data collected at protoDUNE-SP will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Argon in the Martian atmosphere

Heretofore undetected argon may be a significant constituent of the Martian atmosphere with a partial pressure of 1.8 mbar. The addition of argon to the 5.5 plus or minus 0.8 mbar of CO2, deduced from ground-based spectroscopy, is consistent with the values of total pressure deduced from the Mariner radio occulation measurements. The presence of argon in the Martian atmosphere contributes to the cooling of the upper thermosphere and exosphere and may explain the difference between predicted and observed temperatures. The argon concentrations predicted here may be related to the recent observation of several tens of per cent of an inert gas, deduced from Mars-6 data.

Levine, J. S.↗

Lunar cold traps and their influence on argon-40

In polar areas of the moon the maximum temperatures reached in some permanently shaded areas are well below the temperature required to retain water ice for billions of years, and cold enough to hold other volatiles for shorter periods. Aside from water, the most significant lunar volatiles are the radiogenic gases, of which argon-40 is the most easily detected, both in situ and as retrapped ions in rocks returned from the surface on the moon. Argon-40 escapes from the moon at a surprisingly high rate that is between 3% and 6% of its total production. Its brief lifetime in the lunar exosphere is marked by numerous adsorption/desorption events. Collisions with the lunar surface in cold, permanently shaded areas lead to long term storage, forming reservoirs of trapped gas that may be disturbed occasionally to produce sudden increases in atmospheric argon. It is postulated that this may explain at least part of the time variations in Apollo 17 mass spectrometer measurements of argon that were previously attributed to internal processes associated with the release of radiogenic gases from the moon.

Hodges, R. R., Jr.↗

ARCS 3 ionospheric artificial argon ion beam injections - Waves near the heavy ion gyrofrequencies

Low-frequency electric field data below the proton gyrofrequency are presented for the duration of the argon ion beam experiment conducted as part of the Argon Release for Controlled Studies (ARCS) program. An argon ion beam was injected from the subpayload antiparallel or perpendicular to the magnetic field at altitudes from 250 to 405 km. During the injections, the wave spectra were broadband near the subpayload and narrow-band near heavy ion gyrofrequencies at perpendicular separation distances between 42 and 254 m. It is suggested that the narrow-band waves are associated with both the perpendicular argon ion beam and an unexpected flux of low-energy ions which peaked in energy near 15 eV and pitch angle near 90 deg with respect to the magnetic field.

Erlandson, R. E.↗

Measurements of argon broadened Lorentz width and pressure-induced line shift coefficients in the nu4 band of (C-12)H4

Room temperature argon broadened halfwidth and pressure-induced line shift coefficients have been determined for 118 transitions in the nu4 band of (C-12)H4 from analysis of high resolution laboratory absorption spectra recorded with the McMath Fourier transform spectrometer operated on Kitt Peak by the National Solar Observatory. Transitions up to J-double-prime = 12 have been measured using a nonlinear least-squares spectral fitting procedure. The variation of the measured halfwidth coefficients with symmetry type and rotational quantum number is very similar to that measured previously for N2 and air broadening, but the absolute values of the argon broadening coefficients are all smaller. On average, the ratio of the argon broadened halfwidth coefficient to the corresponding N2 broadened halfwidth coefficient is 0.877 + or - 0.017 (2 Sigma). More than 95 percent of the pressure-induced shifts are negative with values ranging from -0.0081 to +0.0055/cm atm. The pressure shifts in argon are nearly equal to corresponding values measured previously in N2 and air.

Rinsland, Curtis P.↗

Argon Analyses of Lherzolic Shergottites Y984028 and Y000097

Antarctic Martian meteorites Yamato (Y) 984028 and Y000027/47/97 have similar textures, mineralogy, chemistry, and isotopic composition and are possibly paired. We analyzed the argon isotopic composition of Y984028 whole rock (WR) and pyroxene mineral separates (Px) in order to evaluate their trapped Ar components and compare with Y000097 Ar data. WR and Px yield an apparent Ar-39-Ar-40 age spectra of roughly 2 Ga, much older than the crystallization age determined by other isotopic techniques. Sm-Nd and Rb-Sr ages for Y984028 are approximately 170 Ma. This discrepancy is likely the byproduct of several coexisting Ar components, such as radiogenic 40Ar*, cosmogenic Ar, and trapped Ar from the multiple minerals, as well as multiple source origins. Similarly, the reported Ar-39-Ar-40 age of Y000097 is approximately 260 Ma with a Rb-Sr age of 147+/- 28 Ma and a Sm-Nd age of 152 +/- 13 Ma [4]. Apparently Ar-Ar ages of both Y984028 and Y000097 show trapped Ar components. Stepwise temperature extractions of Ar from Y984028 Px show several Arcomponents released at different temperatures. For example, intermediate temperature data (800-1100 C) are nominally consistent with the Sm-Nd and Rb-Sr radiometric ages (approximately 170 Ma) with an approximately Martian atmosphere trapped Ar composition with a Ar-40-Ar-36 ratio of approximately 1800. Based on K/Ca distribution, we know that Ar-39 at both lower and intermediate temperatures is primarily derived from plagioclase and olivine. Argon released during higher temperature extractions (1200-1500 C), however, differs significantly. The thermal profile of argon released from Martian meteorites is complicated by multiple sources, such as Martian atmosphere, Martian mantle, inherited Ar, terrestrial atmosphere, cosmogenic Ar. Obviously, Ar release at higher temperatures from Px should contain little terrestrial atmospheric component. Likewise, Xe-129/Xe-132 from high temperature extractions (1200-1800 C) gives a value above that of terrestrial Xe ratio of 0.98. The most plausible explanation of the high temperature argon data is that it contains a Martian mantle Ar-40 component as well as excess Ar-40 assimilated from inherited magma.

Park, J.↗

Pose Measurement Performance of the Argon Relative Navigation Sensor Suite in Simulated Flight Conditions

Argon is a flight-ready sensor suite with two visual cameras, a flash LIDAR, an on- board flight computer, and associated electronics. Argon was designed to provide sensing capabilities for relative navigation during proximity, rendezvous, and docking operations between spacecraft. A rigorous ground test campaign assessed the performance capability of the Argon navigation suite to measure the relative pose of high-fidelity satellite mock-ups during a variety of simulated rendezvous and proximity maneuvers facilitated by robot manipulators in a variety of lighting conditions representative of the orbital environment. A brief description of the Argon suite and test setup are given as well as an analysis of the performance of the system in simulated proximity and rendezvous operations.

Galante, Joseph M.↗

First Measurement of the Flux-Averaged Differential Charged-Current Electron-Neutrino and Antineutrino Cross Section on Argon with the MicroBooNE Detector

The MicroBooNE experiment uses a liquid argon time projection chamber (LArTPC) located at Fermilab, Chicago. MicroBooNE is able to detect neutrinos from two accelerators: on-axis from the Booster Neutrino Beam (BNB) and off-axis from the Neutrinos at the Main Injector (NuMI). While one of the primary objectives of the MicroBooNE experiment is to search for short-baseline neutrino oscillations using the BNB, it also has a rich program of R\&D, neutrino-argon cross section measurements and beyond the standard model searches. This thesis presents a detailed study of the off-axis neutrino flux from the NuMI beam at MicroBooNE as well as measurements of the charged current flux-averaged total and differential electron neutrino and antineutrino cross section on argon using this beam. The data used in these measurements was taken during the first year of MicroBooNE running while the NuMI beam was in forward horn current mode. These are the first high statistics measurement s of ele ctron neutrino argon interactions and include the first measurement of this cross section as a function of the outgoing electron energy and with full angular coverage. The measurement is compared to the GENIE and NuWro generators and shows consistency with both.

Mistry, Krishan Jitesh↗

Comparing generator predictions of transverse kinematic imbalance in neutrino-argon scattering

The largest uncertainties in estimating neutrino-nucleus interaction cross sections lie in the incomplete understanding of nuclear effects. A powerful tool to study nuclear effects is Transverse Kinematic Imbalance. This paper presents the first detailed comparison of the predictions of multiple event generators for distributions associated with Transverse Kinematic Imbalance for neutrino interactions on argon. Predictions for muon neutrinos interacting with an argon target are obtained using four standard neutrino event generation tools (GENIE, NuWro, GiBUU and NEUT). Example opportunities for discrimination between nuclear models leveraging future measurements are highlighted. The predictions shown in this paper are motivated by studying muon neutrinos from the Fermilab Booster Neutrino Beam interacting at the location of the MicroBooNE liquid argon time projection chamber, but the methods directly apply to other accelerator-based liquid argon neutrino experiments such as SBND, ICARUS and DUNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling impurity concentrations in liquid argon detectors

Impurities in noble liquid detectors used for neutrino and dark matter experiments can significantly impact the quality of data. We present an experimentally verified model for describing the dynamics of impurity distributions in liquid argon (LAr) detectors. The model considers sources, sinks, and transport of impurities within and between the gas and liquid argon phases. Measurements of oxygen concentrations in a 20-L LAr multi-purpose test stand are compared to calculations made with this model to show that an accurate description of the concentrations under various operational conditions can be obtained. A result of this analysis is a determination of Henry’s coefficient for oxygen in LAr. Additionally, these calculations also show that some processes have small effects on the impurity dynamics and excluding them yields a solution as a sum of two exponential terms. This solution provides a simple way to extract Henry’s coefficient with negligible approximation error. It is applied to the data and the Henry’s coefficient for oxygen in LAr is obtained as 0.84 +0.09 -0.05 , consistent with literature results. Finally, based on the analysis of the data with the model, we further suggest that, for a large liquid argon detector, barriers to flow (“baffles”) installed in the gas phase to restrict flow can help reduce the ultimate impurity concentration in the LAr.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spatial profile of argon (1s 5 ) metastables in an electron beam generated plasma

Electron beams with an applied magnetic field generate a secondary cold plasma with a selective chemical composition, featuring low-energy ions and metastable species in the discharge periphery, ideal for low-damage plasma treatment of material substrates. In this work, we studied the plasma generated by an e-beam using a 4 kV voltage in a pure argon gas environment under a magnetic field of 150 G and in the pressure range of 25–90 mTorr. We measured the absolute spatial density profile of argon (1 s 5 ) metastables in an electron beam generated plasma by laser-induced fluorescence and found it to be of the order of 10 16 m −3 . The electron temperature and the electron density measured by a Langmuir probe were of the order of 10 16 m −3 and less than an eV respectively. Electron-impact quenching was identified as a significant loss mechanism for the Ar(1s 5 ) state, leading to the saturation of the metastable density at higher pressures. Outside the primary ionization region, the spatial distribution of argon metastables followed a linear diffusion profile, indicating negligible additional production in those regions.

EEDF↗

Novel Liquid Argon Time-Projection Chamber Readouts

Liquid argon time-projection chambers (LArTPCs) have become a prominent tool for experiments in particle physics. Recent years have yielded significant advances in the techniques used to capture the signals generated by these cryogenic detectors. This article summarizes these novel developments for detection of ionization electrons and scintillation photons in LArTPCs. New methods to capture ionization signals address the challenges of scaling traditional techniques to the large scales necessary for future experiments. Pixelated readouts improve signal fidelity and expand the applicability of LArTPCs to higher-rate environments. Methods that leverage amplification in argon enable measurements in the keV regime and below. Techniques to enhance collection of argon scintillation photons improve calorimetry and expand the physics program for very large detectors. Future efforts aim to demonstrate systems for the combined detection of both electrons and photons.

43 PARTICLE ACCELERATORS↗

Synodic and Semiannual Oscillations of Argon-40 in the Lunar Exosphere

The neutral mass spectrometer on the Lunar Atmosphere and Dust Environment Explorer (LADEE) spacecraft collected a trove of exospheric data, including a set of high-quality measurements of radiogenic Ar-40 over a period of 142 days. Data synthesis studies, using well-established exosphere simulation tools, show that the LADEE argon data are consistent with an exosphere-regolith interaction that is dominated by adsorption and that the desorption process generates the Armand distribution of exit velocities. The synthesis work has uncovered an apparent semiannual oscillation of argon that is consistent with temporal sequestration in the seasonal cold traps created at the poles by the obliquity of the Moon. In addition, the LADEE data provide new insight into the pristine nature of lunar regolith, its spatially varying sorption properties, and the influence of sorption processes on the synodic oscillation of the argon exosphere.

argon-40↗