Search NASA⌕ Search

SEARCH · Search NASA

Results for “Automated Mechanical Testing System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

60 records · Page 4

Evaluation of BISON metallic fuel performance modeling against experimental measurements within FIPD and IMIS databases

Simulations were conducted using the BISON fuel performance code on an automated process to read initial and operating conditions from two databases—the Fuels Irradiation and Physics Database (FIPD) and Integral Fast Reactor Materials Information System (IMIS) database. These databases contain metallic fuel data from the Experimental Breeder Reactor-II (EBR-II) and the Fast Flux Test Facility (FFTF). The work demonstrates use of an integrated framework to access EBR-II fuel pin data for evaluating fuel performance models contained within BISON to predict fuel performance of next-generation metallic fuel systems. Between IMIS and FIPD, there is enough information to conduct 1,977 unique EBR-II metallic fuel pin histories from 29 different experiments, and 338 pins from FFTF MFF-3 and MFF-5 with varying levels of details between the two databases. Each of these fuel performance histories includes a high-resolution power history, flux history, coolant channel flow rates, and coolant channel temperatures, and new model developments in BISON since the initial demonstration of this integrated framework. Fission gas release (FGR), cumulative damage fraction, fuel axial swelling, FCCI wastage thickness, cladding profilometry, and burnup were all simulated in BISON and compared to post-irradiation examination (PIE) results to evaluate BISON fuel performance modeling. Implementation of new fuel performance models into a generic BISON input file coupled with IMIS and FIPD yielded results with a better representation of physics than the initial evaluation of the integrated framework. Cladding profilometry, FGR, and fuel axial swelling were found to be in good agreement with PIE measurements for most of the pins simulated. The chosen mechanical contact solver was found to significantly impact the axial fuel swelling and cladding strain predictions when used in conjunction with the U-Pu-Zr hot-pressing model since it bound the fuel to prevent further swelling and increased hydrostatic stresses. This work suggests that fuel performance modeling in BISON under steady-state conditions represents the PIE data well and should be reassessed when new PIE data become available in IMIS and FIPD databases and when improved physical models to better capture fuel performance are added to BISON.

Paaren, Kyle M.↗

Rapid Construction of Validated Chemistry Models for Advanced Biofuels (Co-Optima Final Report)

Computer methods were developed and demonstrated that make it possible to predict the combustion and pyrolysis chemistry of proposed biofuels, even before the biofuels are ever manufactured or experimentally tested. The methods are based on first-principles calculations of reaction rates and equilibria. A large number of complicated calculations are required, so we developed a computer workflow that automates many of the steps. With the chemical structure of the biofuel and the system conditions (temperature, pressure, compositions, etc.) as the input, the computer methods can construct a detailed kinetic model with refined parameters without intense human intervention. The automation of model construction makes it practical for a single engineer to make the predictions in a reasonable time period. The accuracy of the computer predictions was tested by measuring the time-profiles of various reaction intermediates (carbon monoxide, carbon dioxide, water, formaldehyde, methane, and ethylene) formed as the biofuels pyrolyze or ignite using sophisticated laser shock tube methods. Several biofuels, including methyl propyl ether, cyclopentanone, butyl acetate isomers, etc., were carefully studied to demonstrate the validity of the proposed computational and experimental methodology. This research project opens up the possibility for assessing some proposed biofuels on the computer without expensive experimental campaigns. The new computer methods are open source and well-documented, allowing a knowledgeable modeler to easily access the developed methods and implement them in their work routine. Moreover, they are also convenient and powerful, promising for developing the fuel chemistry models needed for use in engine simulators, facilitating co-optimization of new engine designs with new fuels.

09 BIOMASS FUELS↗

Securing Grid-interactive Efficient Buildings (GEB) through Cyber Defense and Resilient System (CYDRES)

The DOE CYDRES project is driven by the urgent need to address critical research gaps in the domain of cyber-physical security of smart buildings, including Grid-interactive Efficient Buildings (GEBs). CYDRES, a real-time advanced building resilient platform, aims to enhance the cyber-attack-immune capabilities of buildings through multi-layered prevention, detection, and adaptation mechanisms. CYDRES consists of five key modules: a multi-layer network analyzer, an Automatic Fault Detection, Diagnosis, and Prognosis (AFDDP) framework, an intelligent mode selector, a cyber-resilient control framework, and a situation awareness platform. The Network Analyzer employs a data-driven framework that includes a protocol state learning tool and a CRF (Conditional Random Field) command validator. In Hardware-In-the-Loop (HIL) testbeds, it achieved 100% detection accuracy with a false alarm rate of 3%, validating its efficacy in identifying selected cyber-attacks. The AFDDP framework leverages pattern matching, PCA (Principal Component Analysis)-based strategies, and a DBN (Dynamic Bayesian Network)-based fault diagnosis approach to pinpoint the causes of physical system abnormalities using Building Automation System (BAS) data. In HIL experiments, the AFDDP module attained a detection accuracy of over 95% with a false alarm rate below 7%. Additionally, the fault detector utilized machine learning (Random Forest) and deep learning (Multi-Layer Perceptron) methods with acoustic sensor data to achieve a 100% fault detection accuracy in Heating, Ventilation, and Air-Conditioning (HVAC) equipment. The Mode Selector offered real-time impact analysis, allowing immediate actions to protect BASs in the face of emerging threats. The cyber-resilient control framework included an adaptive Model Predictive Control (MPC) and a measurement compensator, reducing temperature violations by up to 94% and improving the total demand flexibility by up to 70% in HIL experiments. Such HIL experiments covered a cyber-attack case and a physical fault case, showcasing CYDRES’ efficiency in maintaining operational continuity during threats. The situation awareness platform in Grafana enhanced real-time threat detection and response visualization, augmenting the operational awareness for building operators. CYDRES demonstrated high technical effectiveness in various test scenarios, particularly in HIL environments. The project's phased development approach ensured efficient use of resources, highlighting its practical feasibility and readiness for commercialization. By enhancing the security and resilience of building operations, CYDRES represents a significant advance in mitigating risks associated with cyber-physical systems, thereby enhancing public confidence in the safety of modern building infrastructure. Future directions for the project include expanding testing protocols, refining AFDDP methodologies, exploring more comprehensive resilient control strategies, and testing in real commercial buildings.

42 ENGINEERING↗

Sodium-Cooled Fast Reactor Reference Plant Model

This report details the progress of Idaho National Laboratory (INL) in creating a reference plant multiphysics model for the Advanced Burner Test Reactor (ABTR). This model was developed under Task 13 of the U.S. Nuclear Regulatory Commission project “Development and Modeling Support for Advanced Non-Light Water Reactors,” and is an extension of the reference plant model developed in Task 4b, which was improved upon in the following ways. (1) The discrete ordinates method was used in lieu of the super-homogenization (SPH)-corrected diffusion approximation in order to better capture the anisotropic scattering contribution and the neutron leakage change due to thermal expansion. (2) The novel neutronic spatial discretization approach, termed the ring-heterogeneous (RH) approximation, was conceptualized and introduced to capture the differential expansion of the materials in the core. This new technique proved capable of preserving fission rates and maintaining the eigenvalue within 2.5% and 266 pcm with 9 neutron energy groups, respectively. Separating the different materials in the core enables the differential expansion of materials to be explicitly accounted for, eliminating the need for problem-specific cross-section functionalization techniques. (3) The SAM model for the core and system thermal-hydraulics analysis was updated to include 61 channels instead of just four representative ones. This enables users to obtain improved spatial resolution for sodium temperature and density scalar fields. (4) All the mesh files were created via the Multiphysics Object-Oriented Simulation Environment (MOOSE) Reactor module, eliminating all reliance on external tools for mesh creation. (5) Finally, the fuel axial expansion now leverages the HT9 and UPuZr material properties that have been validated against experimental data. The reference plant model was used to perform a full-core unprotected loss of flow (ULOF) transient calculation, including neutronics, thermal and mechanical feedback mechanisms. Future work will be devoted to further enhancements of the model. Potential improvements to the model include the addition of the control rod driveline expansion feedback and the upgrading of the support plate model so as to explicitly include 3D effects. Additionally, a Nuclear Energy Advanced Modeling and Simulation funded parallel effort has completely automated the creation of the ring-heterogeneous (RH) mesh from the fully heterogeneous (FH) geometry, thus maximizing user friendliness for the sodium fast reactor sodium-cooled fast reactor (SFR) workflow and will be incorporated in future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Battery Life Prediction Using Reduced-Order Physics Models and Machine Learning (CRADA Final Report)

Phase 1 (Original CRADA, plus no-cost extension modifications #1-3, 6/1/2017 to 3/13/2021): The Australian Department of Defence (AUDoD) is performing accelerated aging tests of Li-ion batteries to benchmark their reliability and degradation characteristics. Using its previously developed battery lifetime predictive model framework, the National Laboratory of the Rockies (NLR) will develop analytical models based the AUDoD data to predict lifetime of the multiple Li-ion battery chemistries under real-world use scenarios of interest to AUDoD. The NLR model is based on physical degradation mechanisms encountered by Li-ion batteries and has been previously validated. Phase 2 (CRADA modification #4, plus no-cost extension modification #5, 2/22/2021 to 3/30/2025): Train and support Australian Department of Defence personnel to use NLR software for model-based estimation of Li-ion battery lifetime using accelerated battery aging data collected by the Australian Department of Defence. Under separate DOE funding from 2019 to 2021, NLR enhanced its battery life-prediction software using machine learning algorithms to automate portions of the model-fitting process, requiring significantly less labor and expert judgment and also adding uncertainty quantification, increasing statistical rigor. Under Phase 2, NLR will customize NLR Software and provide it to AuDoD. NLR will enhance its NLR Model to capture aging modes of AuDoD's multi-cell modules, including cell-balancing effects. NLR will develop example single-cell and multi-cell models based on one AuDoD battery aging dataset. NLR will train AuDoD personnel on NLR Software. By the conclusion of the project, NLR will have provided AuDoD the training materials, a user manual and software needed to perform their own analysis of additional and/or future battery aging datasets.

33 ADVANCED PROPULSION SYSTEMS↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗