Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM LOSS MONITOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Accelerators (3/5)

Explore the source record for details and available documents.

BEAM CONTROL↗

Diamond detector technology, status and perspectives

Detectors based on Chemical Vapor Deposition (CVD) diamond have been used extensively and successfully in beam conditions/beam loss monitors as the innermost detectors in the highest radiation areas of Large Hadron Collider (LHC) experiments. The startup of the LHC in 2015 brought a new milestone where the first polycrystalline CVD (pCVD) diamond pixel modules were installed in an LHC experiment and successfully began operation. The RD42 collaboration at CERN is leading the effort to develop polycrystalline CVD diamond as a material for tracking detectors operating in extreme radiation environments. The status of the RD42 project with emphasis on recent beam test results is presented.

3D diamond detectors↗

Pre-commissioning of the wide-dynamic range halo monitor to be installed in the Fermilab MI-8 line

The beam halo can contribute to beam losses in accelerators and is very difficult to measure. With an increase in beam intensity following the PIP-II upgrade at Fermilab, the beam losses are expected to be higher with some coming from beam halo. Therefore, it is important to measure the sources of beam halo to minimize the beam losses. A modified Halo Monitor developed by J-PARC will be installed in Fermilab MI-8 transfer line to measure the beam halo. In this paper, an update on the beam profile monitor fabrication is covered. The updates include the location selection for the Halo Monitor in the MI-8 transfer line, shielding options for instrumentation, initial testing of equipment, and ray tracing simulations for the Offner optics and the targets used in the monitor.

Babacan, Betiay [IIT, Chicago; Fermilab]↗

Extremum Seeking-Based Control System for Particle Accelerator Beam Loss Minimization

Particle accelerators throughout the world vary widely in terms of age and availability of advanced noninvasive diagnostics that provide varying levels of detail about the accelerated beams. Additionally, beam loss measurements and current monitors are ubiquitous in the accelerator community, they are noninvasive, and they are some of the most important metrics in terms of preventing damage or irradiation of beam pipes and equipment for high-energy machines. However, beam loss and current measurements are difficult to use for feedback tuning because of a lack of a known analytic relationship between scalar loss measurements throughout an accelerator and the hundreds of thousands of parameters that influence the beam and time variation of the beam source itself. In this work, we present a model-independent extremum seeking (ES) controller, which has been implemented for automated tuning and optimization of the Los Alamos Neutron Science Center (LANSCE) linear ion accelerator based only on scalar quantities, such as beam loss or flux measurements. We demonstrate the approach on various accelerator subsystems, including groups of radio frequency (RF) accelerating cavities, quadrupole magnets, bending magnets, and steering magnets. This tool is now available as a use graphical user interface (GUI) in the LANSCE control room, allowing beam physicists to choose arbitrary groups of parameters and beam loss or current monitors for adaptive tuning.

43 PARTICLE ACCELERATORS↗

Beam Loss Assessment Through Use of Photomultiplier Tubes

The first machine in the Fermilab Accelerator chain, the Linac, delivers a 400 MeV proton beam. The first portion of the Fermilab Linac, the Drift Tube Linac, lacks the degree of instrumentation necessary for beam tuning. To compensate for this, photomultiplier tube (PMT s) based loss monitors were installed on either side of the first two drift tube tanks, but are not yet operational. One of the main goals in this is to make PMT's operational beam loss monitors for tuning. Noise reduction and peak finding on the PMT data is a requirement for this. A method for noise reduction and peak finding has been developed and implemented to produce a consistent and stable output. Future work includes integration with ACNET to automate input and output of data for analysis of beam loss.

Waggoner, Alexander↗

A review of various methods of detecting and measuring beam halos

Halos in high energy particle beams require constant monitoring to minimise beam losses and damage to accelerator components. Four methods of measuring halos are described: wire scanner, laser wire scanner, diamond detector and halo masking monitors. Details of their effectiveness’ from tests at various accelerators are used to evaluate how useful they are. It is found that methods making use of wire and laser wire scanners are unable to achieve a high enough dynamic range to measure the outer halo, where the intensity of particles is very low. Diamond detectors can be used to determine the presence of a halo, but are unable to reconstruct their shape. The halo masking method, which makes use of a digital micromirror device to block out high intensity light, produces very good results, but it is possible that light is scattered inside the phosphor screen used to produce an image from the beam, skewing the measurements.

43 PARTICLE ACCELERATORS↗

Pre-Commissioning of the Wide-Dynamic Range Halo Monitor to be Installed in the FERMILAB MI-8 Line

The beam halo can contribute to beam losses in accelerators and is very difficult to measure. With an increase in beam intensity following the PIP-II upgrade at Fermilab, the beam losses are expected to be higher with some coming from the beam halo. Therefore, it is important to measure the sources of beam halo to minimize the beam losses. A modified Halo Monitor developed by J-PARC will be installed in Fermilab MI-8 transfer line to measure the beam halo. In this paper, an update on the beam profile monitor fabrication is covered. The updates include the location selection for the Halo Monitor in the MI-8 transfer line, shielding options for instrumentation, and the next steps in commissioning.

Babacan, B. [IIT, Chicago; Fermilab]↗

Loss Control and Monitoring Systems for NSLS-Ii

The tunnel shielding design for the NSLS-II will provide adequate protection for beam losses up to 13nC/min or 100% of the maximum top-off injection beam current to be lost in the two periods of the ring around the injection point, while the remainder of the ring is shielded for lower losses of 1.1nC/min or ≤10% of the maximum top-off injected beam current. Additional local shielding of potential loss points in the injection region (e.g. injection septum) will be used to increase the level of loss allowed at these location during 1 Hz injection (i.e. nonTop-off injection). This shielding design will require a system to insure that beam losses don’t exceed these levels for a period of time that could potentially cause levels of radiation outside the shield walls to exceed administrative levels. This Loss Control and Monitoring (LCM) system will provide a level of loss control, loss location measurements and provide alarm indication of the level of beam power losses along the beam path from the source (e-gun, linac) thru the injection system and the storage ring. This system will consist of collimators and scrapers that will provide limits to the beam miss-steering and control the loss points of the charge, and monitors that will measure the average beam current losses along the beam path and alarm when this beam power loss exceeds the level set by the shielding specifications or administrative levels. This will require some new ideas in beam loss detection capability and collimation. The system is not intended to trip interlocks (dumping beam or terminating injection) but only to alarm that higher than normal beam power losses are observed and report where it is occurring. If the alarms conditions are not corrected within a time limit, top-off injection could be slowed down, thereby reducing the beam loss and the radiation it may be producing.

36 MATERIALS SCIENCE↗

A close look at beam aborts with rise times less than 40 ms from the years 2014-2016. Case studies.

In an effort to understand the risks of operating RHIC with an additional delay of 40 ms in the abort system, all beam aborts triggered by loss monitors at store from the years 2014, 2015 and 2016 were analyzed; and particularly fast cases, selected. The results were presented at the RHIC retreat on Jul 29, 2016. All beam aborts at injection, during the ramp and at flattop but before the “ev-lumi” event were ignored since the additional delay of 40 ms is proposed for operation at store only. Many (but not all) of the 15 studied cases are of no concern. Cases with high damage potential are rare - but not rare enough. In order to make an added 40 ms during physics store conditions as safe as reasonably possible, additional permit inputs such as 10 Hz BF power supplies, RF storage cavities, power supply error states or BPMs, in addition to significantly reduced loss monitors (LM) thresholds for selected LM should be commissioned.

43 PARTICLE ACCELERATORS↗

Upgrade to Fixed and Translating Scintillation-based Loss Detector System in the Fermilab Drift Tube Linac

The closed-off structure of the Fermilab Drift Tube Linac precludes a robust array of instrumentation from directly monitoring the H- beam that is accelerated from 750 keV to 116 MeV. To improve beam tuning and operational assessment of Drift Tube Linac performance, scintillator-based loss monitors were previously installed along the exterior of the first two accelerating cavities to assess low energy beam losses. Here we present a recent upgrade to the loss monitor system, including significant improvements in analog signal processing to address baseline-interfering noise; digitization of the signals to enable regular operational use and tuning; and a new remote operation upgrade of the translating loss monitor with precise positioning of the loss monitor along its nine-foot track. Data from the fixed and translating detectors collected under varying beam conditions validate the utility of the upgrade.

Chen, E. V. [Fermilab]↗

Monitoring Dosimetric Impact of Weight Loss With Kilovoltage (KV) Cone Beam CT (CBCT) During Parotid-Sparing IMRT and Concurrent Chemotherapy

Purpose: Parotid-sparing head-and-neck intensity-modulated radiotherapy (IMRT) can reduce long-term xerostomia. However, patients frequently experience weight loss and tumor shrinkage during treatment. We evaluate the use of kilovoltage (kV) cone beam computed tomography (CBCT) for dose monitoring and examine if the dosimetric impact of such changes on the parotid and critical neural structures warrants replanning during treatment. Methods and materials: Ten patients with locally advanced oropharyngeal cancer were treated with contralateral parotid-sparing IMRT concurrently with platinum-based chemotherapy. Mean doses of 65 Gy and 54 Gy were delivered to clinical target volume (CTV)1 and CTV2, respectively, in 30 daily fractions. CBCT was prospectively acquired weekly. Each CBCT was coregistered with the planned isocenter. The spinal cord, brainstem, parotids, larynx, and oral cavity were outlined on each CBCT. Dose distributions were recalculated on the CBCT after correcting the gray scale to provide accurate Hounsfield calibration, using the original IMRT plan configuration. Results: Planned contralateral parotid mean doses were not significantly different to those delivered during treatment (p > 0.1). Ipsilateral and contralateral parotids showed a mean reduction in volume of 29.7% and 28.4%, respectively. There was no significant difference between planned and delivered maximum dose to the brainstem (p = 0.6) or spinal cord (p = 0.2), mean dose to larynx (p = 0.5) and oral cavity (p = 0.8). End-of-treatment mean weight loss was 7.5 kg (8.8% of baseline weight). Despite a {>=}10% weight loss in 5 patients, there was no significant dosimetric change affecting the contralateral parotid and neural structures. Conclusions: Although patient weight loss and parotid volume shrinkage was observed, overall, there was no significant excess dose to the organs at risk. No replanning was felt necessary for this patient cohort, but a larger patient sample will be investigated to further confirm these results. Nevertheless, kilovoltage CBCT is a valuable tool for patient setup verification and monitoring of dosimetric variation during radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Upgrade to Fixed and Translating Scintillation-Based Loss Detector System in the Fermilab Drift Tube Linac

The closed-off structure of the Fermilab Drift Tube Linac precludes a robust array of instrumentation from directly monitoring the H- beam that is accelerated from 750 keV to 116 MeV. To improve beam tuning and op-erational assessment of Drift Tube Linac performance, scintillator-based loss monitors were previously installed along the exterior of the first two accelerating cavities to assess low energy beam losses. Here we present a recent upgrade to the loss monitor system, including significant improvements in analog signal processing to address baseline-interfering noise; digitization of the signals to enable regular operational use and tuning; and a new remote operation upgrade of the translating loss monitor with precise positioning of the loss monitor along its nine-foot track. Data from the fixed and translating de-tectors collected under varying beam conditions validate the utility of the upgrade.

Chen, Erin V. [Fermilab] (ORCID:0000000215467899)↗

BEAM CONTAINMENT SYSTEM FOR NSLS-II

The shielding design for the NSLS-II will provide adequate protection for the full injected beam loss in two periods of the ring around the injection point, but the remainder of the ring is shielded for lower losses of {le} 10% full beam. This will require a system to insure that beam losses don't exceed these levels for a period of time that could cause excessive radiation levels outside the shield walls. This beam containment system will measure, provide a level of control and alarm indication of the beam power losses along the beam path from the source (e-gun, linac) thru the injection system and the storage ring. This system will consist of collimators that will provide limits to (and potentially to measure) the beam miss-steering and control the loss points of the charge and monitors that will measure the average beam current losses along the beam path and alarm when this beam power loss exceeds the level set by the shielding specifications. This will require some new ideas in beam loss detection capability and collimation. The initial planning and R&D program will be presented.

43 PARTICLE ACCELERATORS↗

A system for monitoring the radiation effects of a proton linear accelerator

The system for real-time monitoring of radioactivity of a high-current proton linear accelerator detects secondary neutron emission from proton beam losses in transport channels and measures the activity of radionuclides in gas and aerosol emissions and the radiation background in the environment affected by a linear accelerator. The data provided by gamma, beta, and neutron detectors are transferred over a computer network to the central server. The system allows one to monitor proton beam losses, the activity of gas and aerosol emissions, and the radiation emission level of a linear accelerator in operation.

07 ISOTOPE AND RADIATION SOURCES↗

Parameter Estimation with Entangled Photons Produced by Parametric Down-Conversion

We explore the advantages offered by twin light beams produced in parametric down-conversion for precision measurement. The symmetry of these bipartite quantum states, even under losses, suggests that monitoring correlations between the divergent beams permits a high-precision inference of any symmetry-breaking effect, e.g., fiber birefringence. We show that the quantity of entanglement is not the key feature for such an instrument. In a lossless setting, scaling of precision at the ultimate ''Heisenberg'' limit is possible with photon counting alone. Even as photon losses approach 100% the precision is shot-noise limited, and we identify the crossover point between quantum and classical precision as a function of detected flux. The predicted hypersensitivity is demonstrated with a Bayesian simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved Beam Loss Accounting with Fast Data Acquisition (DAQ) Chassis

Identifying the source of beam loss events in the CE-BAF accelerator can be a challenging task. However, with our new prototype system, this task becomes more effi-cient. The system, developed in the fall of 2022, utilizes a dispersive beam position monitor (BPM) and the exist-ing switched electrode electronics BPM hardware. Previ-ously a commercial off-the-shelf data acquisition (DAQ) system was employed to capture BPM wire signals at a sample rate of 20 kS/s. The fast shutdown signal triggered the system, which disables the beam at the injector. Analysis of beam position and energy variation before a beam loss event was used to determine if the beam loss event was associated with an energy transient. The proto-type system, implemented using National Instruments hardware and LabVIEW® software, relied on a software trigger. Manual post-processing was required to ascertain whether the fault was due to an un-tripped cavity with a gradient or phase transient. This work focuses on deploying a Fast DAQ Chassis to monitor BPM hardware in real time and during beam loss events. This system was originally developed and in-stalled in CEBAF to monitor the time-domain RF control signals in the legacy analog RF systems. This technology was leveraged to also monitor BPM signals. As the new system employs a hardware trigger, developing tools to automatically identify faults linked to energy transients unrelated to cavity faults will be straightforward. This paper will discuss the project's initial updates, underlin-ing the crucial role of each member of our team in this achievement

Tiskumara, J.↗

Parameter Estimation with Entangled Photons Produced by Parametric Down-Conversion

We explore the advantages offered by twin light beams produced in parametric down-conversion for precision measurement. The symmetry of these bipartite quantum states, even under losses, suggests that monitoring correlations between the divergent beams permits a high-precision inference of any symmetry-breaking effect, e.g., fiber birefringence. We show that the quantity of entanglement is not the key feature for such an instrument. In a lossless setting, scaling of precision at the ultimate "Heisenberg" limit is possible with photon counting alone. Even as photon losses approach 100% the precision is shot-noise limited, and we identify the crossover point between quantum and classical precision as a function of detected flux. The predicted hypersensitivity is demonstrated with a Bayesian simulation.

Cable, Hugo↗