Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM PROFILES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Initial beam-profiling tests with the NML prototype station at the Fermilab A0 Photoinjector

The beam-profile diagnostics station prototype for the superconducting rf electron linac being constructed at Fermilab at the New Muon Lab has been tested. The station uses intercepting radiation converter screens for the low-power beam mode: either a 100-{micro}m thick YAG:Ce single crystal scintillator or a 1-{micro}m thin Al optical transition radiation (OTR) foil. The screens are oriented with the surface perpendicular to the beam direction. A downstream mirror with its surface at 45 degrees to the beam direction is used to direct the radiation into the optical transport. The optical system has better than 20 (10) {micro}m rms spatial resolution when covering a vertical field of view of 18 (5) mm. The initial tests were performed at the A0 Photoinjector at a beam energy of {approx}15 MeV and with micropulse charges from 25 to 500 pC for beam sizes of 45 to 250 microns. Example results will be presented.

43 PARTICLE ACCELERATORS↗

Fiber Optic Picosecond Laser Pulse Transmission Line for Hydrogen Ion Beam Profile Measurement

We present a fiber optic laser pulse transmission line for non-intrusive longitudinal profile measurement of the hydrogen ion (H-) beam at the front-end of the Spallation Neutron Source (SNS) accelerator. The 80.5 MHz, 2.5 ps, multi-killowatt optical pulses are delivered to the accelerator beam line through a large mode area polarization maintaining optical fiber to ensure a high measurement stability. The transmission efficiency, output laser beam quality, pulse jitter and pulse width broadening over a 100-ft fiber line are experimentally investigated. A successful measurement of the H- beam microbunch (~130 ps) profile is obtained. Our experiment is the first demonstration of particle beam profile diagnostics using fiber optic laser pulse transmission line.

fiber optic↗

Inverse planning for IMRT with nonuniform beam profiles using total-variation regularization (TVR)

Purpose: Radiation therapy with high dose rate and flattening filter-free (FFF) beams has the potential advantage of greatly reduced treatment time and out-of-field dose. Current inverse planning algorithms are, however, not customized for beams with nonuniform incident profiles and the resultant IMRT plans are often inefficient in delivery. The authors propose a total-variation regularization (TVR)-based formalism by taking the inherent shapes of incident beam profiles into account. Methods: A novel TVR-based inverse planning formalism is established for IMRT with nonuniform beam profiles. The authors introduce a TVR term into the objective function, which encourages piecewise constant fluence in the nonuniform FFF fluence domain. The proposed algorithm is applied to lung and prostate and head and neck cases and its performance is evaluated by comparing the resulting plans to those obtained using a conventional beamlet-based optimization (BBO). Results: For the prostate case, the authors' algorithm produces acceptable dose distributions with only 21 segments, while the conventional BBO requires 114 segments. For the lung case and the head and neck case, the proposed method generates similar coverage of target volume and sparing of the organs-at-risk as compared to BBO, but with a markedly reduced segment number. Conclusions: TVR-based optimization in nonflat beam domain provides an effective way to maximally leverage the technical capacity of radiation therapy with FFF fields. The technique can generate effective IMRT plans with improved dose delivery efficiency without significant deterioration of the dose distribution.

60 APPLIED LIFE SCIENCES↗

Accuracy and Resolution Evaluation of the E-Beam Profile Scanner at the Fermilab Main Injector

The objective of this work is to assess the accuracy of measurements made by the Electron Beam Profile Scanner (EBPS), which captures the trajectory of an electron beam with and without a proton beam present. The proton beam induces deflection in the electron beam, which is influenced by proton charges. For high-resolution images, the probe beam needs to be of high intensity, small diameter, and small divergence, evaluated using a phosphor screen and an optical transition radiation (OTR) screen. The capabilities of the Kimball Physics electron gun (eGun) will be considered for accuracy. Additionally, the Zemax software will be utilized to characterize the optical elements.

Mwaniki, M. W. [IIT, Chicago] (ORCID:0000000169057↗

Generation of strong terahertz fields exceeding 8 MV/cm at 1 kHz and real-time beam profiling

We demonstrate high-field (>8 MV/cm) terahertz generation at a high-repetition-rate (1 kHz) via two-color laser filamentation. Here, we use a cryogenically cooled femtosecond laser amplifier capable of producing 30 fs, 15 mJ pulses at 1 kHz as a driver, along with a combination of a thin dual-wavelength half-waveplate and a Brewster-angled silicon window to enhance terahertz generation and transmission. We also introduce a cost-effective, uncooled microbolometer camera for real-time terahertz beam profiling with two different modes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

From Conducting Paint to Ion Chamber and Beam Profile Monitor

This paper describes the process of using conducting paint in the fabrication of Ion Chambers and Beam Profile Monitors. After a brief introduction, a number of examples of chamber designs are described, along with the role that conducting paint plays in their design.

43 PARTICLE ACCELERATORS↗

From Conducting Paint to Ion and Beam Profile Chamber

This paper describes the process of using conducting paint in the fabrication of Ion Chambers and Beam Profile Monitors. After a brief introduction, a number of examples of chamber designs are described, along with the role that conducting paint plays in their design.

43 PARTICLE ACCELERATORS↗

WIRE SCANNER FOR HIGH INTENSITY BEAM PROFILE DIAGNOSITICS

A control and data acquisition system of a high speed wire scanner is developed for high intensity beam profile diagnostics. The control system of the wire scanner includes two IOCs, a Soft IOC and a VME IOC. The Soft IOC connects with an Aerotech Ensemble motor drive through EPCIS motor record and controls the movement of the wire scanner. An Electrical Input card samples the real-time position of the wire through an incremental encoder, and generates a pulse to synchronize a VME ADC data acquisition card, which digitizes and samples the beam-induced signal after pre-amplification. A VME Relay Output card is installed to control the Brake Solenoid and Actuator Solenoid. All the VME I/O cards are installed on one VME crate and controlled by the VME IOC. The system configuration and software of the wire scanner are under development.

Yan, J.↗

Effect of the pump beam profile and wavefront on the amplified signal wavefront in optical parametric amplifiers

We present a theoretical and experimental analysis of the signal phase introduced by the pump-beam wavefront and spatial profile during optical parametric amplification (OPA) process. The theory predicts the appearance of an additional wavefront in the amplified signal beam that is proportional to the spatial derivative of the pump-beam wavefront. The effect of the pump-beam profile on the signal-beam wavefront is also investigated. Our experiments tested these theoretical predictions by comparing the wavefront of the signal beam before and after amplification in a multi-joule broadband OPA. The measured signal wavefront was shown to have the expected dependence on the pump-beam profile and wavefront. These results can be considered when designing petawatt-scale ultrabroadband optical parametric chirped-pulse–amplification systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Target design optimization for an electron accelerator driven subcritical facility with circular and square beam profiles.

A subcritical facility driven by an electron accelerator is planned at the Kharkov Institute of Physics and Technology (KIPT) in Ukraine for medical isotope production, materials research, training, and education. The conceptual design of the facility is being pursued through collaborations between ANL and KIPT. As part of the design effort, the high-fidelity analyses of various target options are performed with formulations to reflect the realistic configuration and the three dimensional geometry of each design. This report summarizes the results of target design optimization studies for electron beams with two different beam profiles. The target design optimization is performed via the sequential neutronic, thermal-hydraulic, and structural analyses for a comprehensive assessment of each configuration. First, a target CAD model is developed with proper emphasis on manufacturability to provide a basis for separate but consistent models for subsequent neutronic, thermal-hydraulic, and structural analyses. The optimizations are pursued for maximizing the neutron yield, streamlining the flow field to avoid hotspots, and minimizing the thermal stresses to increase the durability. In addition to general geometric modifications, the inlet/outlet channel configurations, target plate partitioning schemes, flow manipulations and rates, electron beam diameter/width options, and cladding material choices are included in the design optimizations. The electron beam interactions with the target assembly and the neutronic response of the subcritical facility are evaluated using the MCNPX code. the results for the electron beam energy deposition, neutron generation, and utilization in the subcritical pile are then used to characterize the axisymmetric heat generation profiles in the target assembly with explicit simulations of the beam tube, the coolant, the clad, and the target materials. Both tungsten and uranium are considered as target materials. Neutron spectra from tungsten and uranium are very similar allowing the use of either material in the subcritical assembly without changing its characteristics. However, the uranium target has a higher neutron yield, which increases the neutron flux of the subcritical assembly. Based on the considered dimensions and heat generation profiles, the commercial CFD software Star-CD is used for the thermal-hydraulic analysis of each target design to satisfy a set of thermal criteria, the most limiting of which being to maintain the water temperature 50 below the boiling point. It is found that the turbulence in the inlet channels dissipates quickly in narrow gaps between the target plates and, as a result, the heat transfer is limited by the laminar flow conditions. On average, 3-D CFD analyses of target assemblies agree well with 1-D calculations using RELAP (performed by KIPT). However, the recirculation and stagnation zones predicted with the CFD models prove the importance of a 3-D analysis to avoid the resulting hotspots. The calculated temperatures are subsequently used for the structural analysis of each target configuration to satisfy the other engineering design requirements. The thermo-structural calculations are performed mostly with NASTRAN and the results occasionally compared with the results from MARC. Both, NASTRAN and MARC are commercially available structural-mechanics analysis software. Although, a significant thermal gradient forms in target elements along the beam direction, the high thermal stresses are generally observed peripherally around the edge of thin target disks/plates. Due to its high thermal conductivity, temperatures and thermal stresses in tungsten target are estimated to be significantly lower than in uranium target. The deformations of the target disks/plates are found to be insignificant, which eliminate concerns for flow blockages in narrow coolant channels. Consistent with the specifications of the KIPT accelerator to be used in this facility, the electron beam power is 100-kW with electron energy in the range of 100 to 200 MeV. As expected, the 100 MeV electrons deposit their energy faster while the 200-MeV electrons spread their energy deposition further along the beam direction. However in that electron energy range, the energy deposition profiles near the beam window require very thin target plates/disks to limit the temperatures and thermal stresses.

43 PARTICLE ACCELERATORS↗

Influence of laser beam profile on electromagnetically induced absorption

We compared, experimentally and theoretically, Hanle electromagnetically induced absorption (EIA) obtained using Gaussian and {Pi}-shaped laser beams 3 mm in diameter. The study was done by measuring the transmission of a laser locked to the F{sub g}=2{yields}F{sub e}=3 transition at the D{sub 2} line of {sup 87}Rb in a vacuum cell. EIA linewidths obtained for the two laser profiles were significantly different in the range of laser intensities 1-4 mW/cm{sup 2}. EIA with the {Pi}-shaped laser beam has a broad intensity maximum and linewidths larger than those obtained with the Gaussian beam profile. We also studied Hanle EIA by measuring the transmission of selected segments of the entire laser beam by placing a small movable aperture in front of the detector. Waveforms so obtained in Hanle EIA resonances were strongly influenced both by the radial distance of the transmitted segment from the beam center and by the radial profile of the laser beam. We show that outer regions of Gaussian beam, and central regions of the {Pi}-shaped beam generate the narrowest lines. The different behaviors of EIA owing to different beam profiles revealed by both theory and experiment indicate the importance of the radial profile of the laser beam for proper modeling of coherent effects in alkali metal vapors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

All-optical structuring of laser-driven proton beam profiles

Here, extreme field gradients intrinsic to relativistic laser-interactions with thin solid targets enable compact MeV proton accelerators with unique bunch characteristics. Yet, direct control of the proton beam profile is usually not possible. Here we present a readily applicable all-optical approach to imprint detailed spatial information from the driving laser pulse onto the proton bunch. In a series of experiments, counter-intuitively, the spatial profile of the energetic proton bunch was found to exhibit identical structures as the fraction of the laser pulse passing around a target of limited size. Such information transfer between the laser pulse and the naturally delayed proton bunch is attributed to the formation of quasi-static electric fields in the beam path by ionization of residual gas. Essentially acting as a programmable memory, these fields provide access to a higher level of proton beam manipulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Skimmer-Nozzle Configuration Measurements for a Gas Sheet Beam Profile Monitor

Understanding the characteristics of the gas sheet being produced and optimal configuration of the gas injection system is essential to the the performance of a gas sheet beam profile monitor. A gas injection system test stand has been built at Fermilab to test various nozzle and slit configurations. The distance between the nozzle and slit can be changed to find an optimal configuration. Using a moveable cold cathode gauge the gas profile is measured.

43 PARTICLE ACCELERATORS↗

Laser wire beam profile monitor in the Spallation Neutron Source (SNS) superconducting linac

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is an accelerator based neutron scattering facility. The SNS uses the large scale high energy superconducting linac (SCL) to provide high beam power utilizing hydrogen ion (H-) beams. For the diagnostics of high-brightness H- beam in the SCL, nonintrusive methods have to be developed. This paper describes design, implementation, theoretical analysis and experimental demonstration of a nonintrusive profile monitor system based on photodetachment, also known as laser wire, installed in the SNS-SCL. The SNS laser wire system is the largest of its kind with a capability of measuring both horizontal and vertical profiles of an operational H- beam at each of the 23 cryomodule stations along the SCL beam line by employing a single light source. Presently 9 laser wire stations have been commissioned which measures H- beam profiles at 9 different locations corresponding to energy levels of 200 MeV to 1 GeV. The laser wire diagnostics has no moving parts inside the beam pipe, causes no contamination on the superconducting surface, and can be run parasitically on an operational neutron production H- beam.

43 PARTICLE ACCELERATORS↗

Lightwave-driven electron emission for polarity-sensitive terahertz beam profiling

The full exploitation of advanced light sources in the terahertz (THz) frequency range requires versatile experimental tools to fully characterize the spatial, temporal, and spectral shapes of the THz electric field. Several techniques for passive THz beam profiling exist that offer information about the temporally integrated intensity. Thus, any information about the electric field itself is lost. Here, we show that a UV–visible light emission produced via a lightwave-driven field emission from single-layer metasurfaces can be used to visualize the peak electric field distribution of THz beams in real time. Our technique is scalable up to frequencies approaching the plasma frequency of the metal used for the metasurface. Uniquely, our device is sensitive to the absolute polarity of the THz lightwave. These findings demonstrate a general pathway to designing metamaterial-based field-sensitive optical detectors suitable for the entire THz and IR spectral region.

42 ENGINEERING↗

A real-time intercepting beam-profile monitor for a medical cyclotron

There is a lack of real-time continuous beam-diagnostic tools for medical cyclotrons due to high power deposition during proton irradiation. To overcome this limitation, we have developed a profile monitor that is capable of providing continuous feedback about beam shape and current in real time while it is inserted in the beam path. This enables users to optimize the beam profile and observe fluctuations in the beam over time with periodic insertion of the monitor.

43 PARTICLE ACCELERATORS↗

Installation Status of the Electron Beam Profiler for the Fermilab Main Injector

The planned neutrino program at Fermilab requires large proton beam intensities in excess of 2 MW. Measuring the transverse profiles of these high intensity beams is challenging and often depends on non-invasive techniques. One such technique involves measuring the deflection of a probe beam of electrons with a trajectory perpendicular to the proton beam. A device such as this is already in use at the Spallation Neutron Source at ORNL and the installation of a similar device is underway in the Main Injector at Fermilab. The present installation status of the electron beam profiler for the Main Injector will be discussed together with some simulations and test stand results.

43 PARTICLE ACCELERATORS↗