Beamline for E-beam processing at UITF

Electron beam irradiation is a method that has shown a good potential to reduce several pollutants in wastewater. One of the main challenges towards wider adoption of this method is the need for compact, reliable, cost-effective, high-power accelerators. Jefferson Lab is working on the design and prototyping of accelerator components, based on superconducting radio-frequency (SRF) technology, aiming at accelerators for industrial applications. The LDRD project aimed at designing, procuring, installing, and commissioning a beamline at the Upgraded Injector Test Facility (UITF) accelerator to allow electron-beam irradiation studies of different materials, beginning with wastewater. The availability of such beamline allows exploring the ability of electron-beam radiation to reduce or eliminate so-called “forever chemicals” that can be found in wastewater or industrial sites. After successful commissioning, the beamline was used to irradiate wastewater samples with different concentrations of 1,4-dioxane, in collaboration with Hampton Roads Sanitation District (HRSD).

42 ENGINEERING↗

Electron Beam Treatment of Ballast Water

Members from the Great Waters Research Collaborative (GWRC), a project of the University of Wisconsin-Superior (UWS) Lake Superior Research Institute (LSRI), will be bringing two water types to simulate the electron beam removal process for ballast waters. These two types are named low challenge and high challenge. The Low Challenge water is highly transparent water with very low concentration of total suspended solids and dissolved organic carbon. The High Challenge water is like Duluth-Superior Harbor water with low transparency and higher concentration of total suspended solids and dissolved organic carbon. Both water types will undergo a series of applied electron beam radiations and analysis to meet ballast water discharge standards. For the analysis there are standard test organisms that will be evaluated for mortality. Heterotrophic bacteria (E. coli) along with Selenastrum capricornutum will be used and then Eucyclops spp. (or Hyalella azteca) and Daphnia magna will also be evaluated.

43 PARTICLE ACCELERATORS↗

Power loss analysis for optical cavity of X-ray free-electron laser oscillator at 10 KeV

We investigate properties of optical elements in the optical cavity of an X-ray free electron laser oscillator with emphasis on power loss of a monochromatic Gaussian radiation beam upon passing through them using analytical and numerical approaches. Here we assume the optical cavity comprises of refractive lenses and Bragg crystals exploiting symmetric Bragg scattering. For lens, we include the focusing and curvature effects while we include the angular filtering due to finite Darwin width of Bragg crystals. Our results indicate feasibility of Xray power outcoupling in the range of 0.5-28 % with intra-cavity reflectivity of 67-95 % at 10.321 KeV.

43 PARTICLE ACCELERATORS↗

Effect of interparticle fields and radiation reaction on beam dynamics

The dynamics of relativistic particles in an intense electromagnetic field can be described by the Landau-Lifshitz (LL) equation, where the radiation reaction (RR) is accounted for via a self-force, and interparticle fields are often neglected as an approximation. However, the inclusion of interparticle fields is necessary to ensure energy-momentum conservation, particularly during coherent emission. Here we present (i) an analytical proof showing that the energy-momentum conservation law of the Hamilton-Rohrlich-Dirac action, which is divergence free and describes a generic system of interacting charges, respects causality and provides physically sensible results; (ii) a simple generalization of the LL equation for many particles evaluated as a function of the total field, i.e., the sum of the external and interparticle fields. By performing first-principles numerical simulations of a neutral, relativistic bunch of electrons and positrons (e − /e + ) colliding with a laser pulse, this theory is shown to satisfy energy-momentum conservation when interparticle fields and RR are simultaneously taken into account; and (iii) the combined effect of interparticle fields and RR primarily affects the tail of the particle energy distribution. Additionally, our first-principles simulations show that the effect of interparticle fields on beam energy loss becomes smaller when most of the radiated energy is incoherent.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam Spill in Downstream Transport due to Injector Faults [PowerPoint]

We have investigated injector faults with numerical experiments. For this investigation we used the nominal tune that is also being used to assess beam stability. Beam spill in the DST due to a serious injector fault was evaluated using the LSP slice algorithm. Only the most serious fault investigated (-350 keV) caused beam spill in the DST. DST transport focusing solenoids limit the beam spill. Beam spill in the DST is the result of large halo caused by betatron oscillations of the mismatched beam. Bremsstrahlung radiation from the DST beam spill was estimated from Tom Martin scaling normalized to DARHT-I. In conclusion, Scorpius is reasonably safe from beam spill radiation in the DST due to injector faults.

43 PARTICLE ACCELERATORS↗

Mode matching method for absorption spectroscopy systems

Systems and methods for controlling optical feedback in an optical system. A resonant optical cavity includes at least two cavity mirrors, one of which is a cavity coupling mirror, and has a plurality of optical resonance cavity modes. A radiation source emits a beam of continuous wave radiation and is capable of being scanned whereby a mean optical frequency of the continuous wave radiation beam is adjustable over a range of frequencies, wherein the radiation source is responsive to optical feedback radiation emerging from the cavity, and wherein the mode matching optics couples the beam of continuous wave radiation to the cavity via the cavity coupling mirror. The radiation source and the mode matching optics are aligned so that a mode fill ratio is reduced relative to a maximum mode fill ratio, wherein the laser beam is coupled with a fundamental cavity mode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of the Beam Losses and the Radiation Levels in the Electrostatic Septum for Slowextraction at 8 GEV

Extraction of beam from the Fermilab Delivery Ring for the Mu2e Experiment is hindered by large radiative losses initiated within the electrostatic septum (ESS) components of the resonant extraction system (RES). Of particular concern are beam losses causing potential damages to the support components of the RES, diminished intensity for experimental statistics, and high radiation levels in the area of the RES. Here we present the detailed study of beam energy deposition and radiation levels of components and surrounding regions of the ESS in the RES at Fermilab using the MARS Monte Carlo code system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monte Carlo simulations demonstrating physics of equivalency of gamma, electron-beam, and X-ray for radiation sterilization

We report the sterilization of medical devices using the gamma rays from the decay of cobalt-60 has accumulated decades of experience of the performance of the materials and devices that are irradiated. The use of radiation using electron beams and x-rays has much less experience and this leads to questions of equivalency between these three technologies. Computer simulations were conducted to model the relevant physical processes of the interactions of each of the three forms of radiation in order to compare the spectra of electron energies at energies below 500 keV. It is predominantly the electrons below this threshold that produce the sterilization dose. No difference in energy spectra was seen between the three types of initial radiation. It is concluded that there is no energy dependent difference between gamma, e-beam, and x-ray for radiation sterilization.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reconstruction of beam parameters and betatron radiation spectra measured with a Compton spectrometer

The photon flux resulting from high-energy electron beam interactions with high-field systems, such as those found in the upcoming FACET-II experiments at the SLAC National Accelerator Laboratory, yields deep insight into the electron beam’s underlying dynamics during the interaction. However, extracting this information is an intricate process. To demonstrate how to approach this challenge using modern methods, this paper utilizes simulated data that models plasma wakefield acceleration-derived betatron radiation in experiments to determine reliable methods of reconstructing key beam and beam-plasma interaction properties. For betatron radiation measurements, translating the observed 200⁢ keV to 30⁢ MeV photon double-differential energy-angle spectra obtained from an advanced Compton spectrometer requires testing multiple methods to optimize the pipeline from its response to incident electron beam information. The paper compares maximum likelihood estimation and machine learning to refine the translation of photon spectra into precise electron beam metrics, such as spot size, energy, and emittance, enhancing the understanding of beam behavior within these dense, high-field environments. We also introduce machine learning and the expected maximization algorithm to reconstruct the primary photon spectrum, employing a multilayer neural network for regression analysis of the energy and angle spectra. With appropriate modifications, the advanced methods reproduce relevant incident beam parameters with high accuracy, even for beam sizes in the <10 μ⁢m range. This capacity is critical to understanding intense beam propagation and its optimization in plasma.

Beam code development & simulation techniques↗

Pulsed-Beam Transmission Electron Microscopy and Radiation Damage

Here, we review the use of pulsed electron-beams in transmission electron microscopes (TEMs) for the purpose of mitigating specimen damage. We begin by placing the importance of TEMs with respect to materials characterization into proper context, and we provide a brief overview of established methods for reducing or eliminating the deleterious effects of beam-induced damage. We then introduce the concept of pulsed-beam TEM, and we briefly describe the basic methods and instrument configurations used to create so-called temporally structured electron beams. Following a brief overview of the use of high-dose-rate pulsed-electron beams in cancer radiation therapy, we review historical speculations and more recent compelling but mostly anecdotal findings of a pulsed-beam TEM damage effect. This is followed by an in-depth technical review of recent works seeking to establish cause-and-effect relationships, to conclusively uncover the presence of an effect, and to explore the practicality of the approach. These studies, in particular, provide the most compelling evidence to date that using a pulsed electron beam in the TEM is indeed a viable way to mitigate damage. Throughout, we point out current gaps in understanding, and we conclude with a brief perspective of current needs and future directions.

36 MATERIALS SCIENCE↗

Dose-Weighted Radiographic Source-Spot Size

The spatial resolution of a flash radiograph is determined by the time-integrated size of the radiation source. Since the radiation pulse includes the beam head and tail, which may be substantially larger than the beam body, the radiation source is larger than the focused flattop of the electron beam pulse. Moreover, the radiation dose rate is weighted by both beam current and electron energy, and it is the radiation dose that forms the radiograph image. Therefore, in order to estimate radiographic resolution from computer simulations of a focused electron beam, one should use a dose weighted moment analysis of the radiation source distribution. This approach is used to show that, in the absence of beam effects other than space-charge and emittance, radiographic resolution for Scorpius exceeds requirements, regardless of reasonable timing options for current and gap-voltage pulses.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electro-optic sampling based characterization of broad-band high efficiency THz-FEL

Extremely high beam-to-radiation energy conversion efficiencies can be obtained in a THz FEL using a strongly tapered helical undulator at the zero-slippage resonant condition, where a circular waveguide is used to match the radiation group velocity to the electron beam longitudinal velocity. In this paper we report on the first electro-optic sampling (EOS) based measurements of the broadband THz FEL radiation pulses emitted in this regime. The THz field waveforms are reconstructed in the spatial and temporal domains using multi-shot and single-shot EOS schemes respectively. The measurements are performed varying the input electron beam energy in the undulator providing insights on the complex dynamics in a waveguide FEL.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiation Characterization Summary: NETL Beam Port 1/5 Free-Field Environment at the 128-inch Core Centerline Adjacent (NETL-FF-BP1/5-128-cca)

This document presents the facility-recommended characterization of the neutron, prompt gamma ray, and delayed gamma ray radiation fields in the University of Texas at Austin Nuclear Engineering Teaching Laboratory (NETL) TRIGA reactor for the beam port 1/5 free-field environment at the 128-inch location adjacent to the core centerline. The designation for this environment is NETL-FF-BP1/5-128-cca. The neutron, prompt gamma ray, and delayed gamma ray energy spectra, uncertainties, and covariance matrices are presented as well as radial and axial neutron and gamma ray fluence profiles within the experiment area of the cavity. Recommended constants are given to facilitate the conversion of various dosimetry readings into radiation metrics desired by experimenters. Representative pulse operations are presented with conversion examples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Modular Accelerator Robotics Framework for AD Robotics

Accelerator tunnels, such as the ones at Fermilab, remain highly radioactive after beam shutoff due to induced radiation from the beam. This residual radiation creates a hazardous environment for manual inspection and repair of beamline components. To minimize worker radiation dose and reduce beam downtime, the AD Robotics Initiative previously built a fleet of low-cost custom mobile robots. However, the custom Python sockets server-client architecture lacked standardization, causing development delays and complicating the integration of new sensors and actuators. Here, we developed a modular system using ROS2 and Docker to standardize the teleoperation and control interfaces. This system was validated by implementing a teleoperation controller with real-time, low-latency, and high-definition video feedback. The aim of this framework is for a new feature or even a robot to be integrated into the system simply by documenting the hardware configuration. Current integration of LiDAR, Odometry, and Depth Cameras provides the foundation for Simultaneous Localization and Mapping (SLAM) tasks. Finally, future work involves integration into the accelerator control system and the attachment of a 6 degree-of-freedom robotic arm for telemanipulation.

Rayyan Khan, M. [Fermilab; Rensselaer Poly.; Unlis↗

Modular Accelerator Robotics Framework Implementation For Accelerator Inspection

Accelerator tunnels, such as the ones at Fermilab, remain highly radioactive after beam shutoff due to induced radiation from the beam. This residual radiation creates a hazardous environment for manual inspection and repair of beamline components. To minimize worker radiation dose and reduce beam downtime, the AD Robotics Initiative previously built a fleet of low-cost custom mobile robots. However, the custom Python sockets server-client architecture lacked standardization, causing development delays and complicating the integration of new sensors and actuators. Here, we developed a modular system using ROS2 and Docker to standardize the teleoperation and control interfaces. This system was validated by implementing a teleoperation controller with real-time, low-latency, and high-definition video feedback. The aim of this framework is for a new feature or even a robot to be integrated into the system simply by documenting the hardware configuration. Current integration of LiDAR, Odometry, and Depth Cameras provides the foundation for Simultaneous Localization and Mapping (SLAM) tasks. Finally, future work involves integration into the accelerator control system and the attachment of a 6 degree-of-freedom robotic arm for telemanipulation.

Rayyan Khana, M. [Unlisted, US, IL] (ORCID:0009000↗