Search NASA⌕ Search

SEARCH · Search NASA

Results for “BLOOD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Engineering studies of vectorcardiographs in blood pressure measuring systems, appendix 2

The development of a cardiovascular monitoring system to noninvasively monitor the blood pressure and heart rate using pulse wave velocity was described. The following topics were covered: (1) pulse wave velocity as a measure of arterial blood pressure, (2) diastolic blood pressure and pulse wave velocity in humans, (3) transducer development for blood pressure measuring device, and (4) cardiovascular monitoring system. It was found, in experiments on dogs, that the pulse wave velocity is linearly related to diastolic blood pressure over a wide range of blood pressure and in the presence of many physiological perturbations. A similar relationship was observed in normal, young human males over a moderate range of pressures. Past methods for monitoring blood pressure and a new method based on pulse wave velocity determination were described. Two systems were tested: a Doppler ultrasonic transducer and a photoelectric plethysmograph. A cardiovascular monitoring system was described, including operating instructions.

Mark, R. G.↗

Some potential blood flow experiments for space

Blood is a colloidal suspension of cells, predominantly erythrocytes, (red cells) in an aqueous solution called plasma. Because the red cells are more dense than the plasma, and because they tend to aggregate, erythrocyte sedimentation can be significant when the shear stresses in flowing blood are small. This behavior, coupled with equipment restrictions, has prevented certain definitive fluid mechanical studies from being performed with blood in ground-based experiments. Among such experiments, which could be satisfactorily performed in a microgravity environment, are the following: (1) studies of blood flow in small tubes, to obtain pressure-flow rate relationships, to determine if increased red cell aggregation can be an aid to blood circulation, and to determine vessel entrance lengths, and (2) studies of blood flow through vessel junctions (bifurcations), to obtain information on cell distribution in downstream vessels of (arterial) bifurcations, and to test flow models of stratified convergent blood flows downstream from (venous) bifurcations.

Cokelet, G. R.↗

In Vivo Model to Test Implanted Biosensors for Blood pH

Biosensors for monitoring physiologic data continuously through telemetry are available for heart rate, respiration, and temperature but not for blood pH or ions affected by hydrogen ion concentration. A telemetric biosensor for monitoring blood pH on-line could be used to identify and manage problems in fluid and electrolyte metabolism, cardiac and respiratory function during space flight and the acid-base status of patients without the need for venipuncture in patients on Earth. Critical to the development of biosensors is a method for evaluating their performance after implantation. Mature rats, prepared with jugular, cannulas for repeated blood samples, were exposed to a gas mixture containing high levels of carbon dioxide (7%) in a closed environment to induce mild respiratory acidosis. Serial blood gas and pH measurements in venous blood were compared with electrical responses from sensors implanted in the subcutaneous tissue. Animals became slightly tachypneic after exposure to excess CO2, but remained alert and active. After 5 minutes, basal blood pH decreased from 7.404 +/- 0.013 to 7.289 +/- 0.010 (p less than 0.001)and PC02 increased from 45 +/- 6 to 65 +/- 4 mm. Hg (p les than 0.001). Thereafter pH and blood gas parameters remained stable. Implanted sensors showed a decrease in millivolts (mV) which paralleled the change in pH and averaged 5-6 mV per 0.1 unit pH. Implanted sensors remained sensitive to modest changes in tissue pH for one week. A system for inducing acidosis in rats was developed to test the in vivo performance of pH biosensors. The system provides a method which is sensitive, rapid and reproducible in the same and different animals with full recovery, for testing the performance of sensors implanted in subcutaneous tissues.

Arnaud, Sara B.↗

On-Orbit, Immuno-Based, Label-Free White Blood Cell Counting System with Microelectromechanical Sensor Technology (OILWBCS-MEMS)

Aurora Flight Sciences, in partnership with Draper Laboratory, has developed a miniaturized system to count white blood cells in microgravity environments. The system uses MEMS technology to simultaneously count total white blood cells, the five white blood cell differential subgroups, and various lymphocyte subtypes. The OILWBCS-MEMS detection technology works by immobilizing an array of white blood cell-specific antibodies on small, gold-coated membranes. When blood flows across the membranes, specific cells' surface protein antigens bind to their corresponding antibodies. This binding can be measured and correlated to cell counts. In Phase I, the partners demonstrated surface chemistry sensitivity and specificity for total white blood cells and two lymphocyte subtypes. In Phase II, a functional prototype demonstrated end-to-end operation. This rugged, miniaturized device requires minimal blood sample preparation and will be useful for both space flight and terrestrial applications.

Edmonds, Jessica↗

Characterization of Jugular Venous Blood Flow During Acute Fluid Shifts

INTRODUCTION Exposure to weightlessness induces a headward fluid shift and redistribution of fluids, resulting in increased internal jugular vein (IJV) cross-sectional area and altered IJV blood flow dynamics including stasis and retrograde flow. These findings may contribute to various risks of spaceflight, including thrombosis or other risks affected by cerebral venous blood flow. To date, our understanding of the cerebral venous outflow dynamics is limited to the left IJV assessed ~45and ~150days into spaceflight. Therefore, it is unknown how quickly the alterations in venous blood flow dynamics change as a result of weightlessness. The purpose of this study is to determine 1) if venous stasis is an immediate effect of weightlessness, and therefore a risk for short-duration missions, and 2) the effect of weightlessness on brachiocephalic venous flow. METHODS In this study, we will determine the effects of acute weightlessness during parabolic flight on right and left IJV cross-sectional area, as well as blood flow dynamics through the IJV and brachiocephalic veins in 12 healthy subjects. Baseline ultrasound images will be obtained on the ground prior to the parabolic flight in the seated and supine postures to determine normal changes in blood flow with posture-induced fluid shifts in a 1genvironment. Subjects will then undergo parabolic flight withrepeated,~20 second exposure to 0g. Each data collection session will include 2D ultrasonography to quantify IJV cross-sectional area and Doppler ultrasonography to characterize venous blood flow patterns in the IJV and brachiocephalic veins. RESULTS Data collection for this study is planned to take place in October, 2021.CONCLUSIONS This study will characterize the immediate venous response in the left and right IJV and brachiocephalic veins upon entry into weightlessness. The results from this parabolic flight study will be compared with previous data from International Space Station crewmembers collectedafter~45 and ~150 days into spaceflight to provide a more complete understanding of the temporal profile of changes in venous blood flow dynamics during weightlessness and whether these findings develop in veins other than the left IJV. Supported by the NASA Human Research Program.

K Marshall-Bowman↗

Blood treatment device priming devices, methods, and systems

Simple-to-use systems, methods, and devices for priming replacement blood treatment devices, for swapping the blood treatment devices out, for replacing swapped-out blood treatment devices, and other related operations are described. In embodiments, a blood treatment device can be primed while a therapy is still running. When the replacement blood treatment device is needed, the therapy can be stopped momentarily (less than a minute) for the rapid and safe swap of the blood treatment device. Blood loss can be minimized. The down time from therapy can be minimized.

Brugger, James M.↗

Effects of perfluorohexane vapor on relative blood flow distribution in an animal model of surfactant-depleted lung injury

OBJECTIVE: To test the hypothesis that treatment with vaporized perfluorocarbon affects the relative pulmonary blood flow distribution in an animal model of surfactant-depleted acute lung injury. DESIGN: Prospective, randomized, controlled trial. SETTING: A university research laboratory. SUBJECTS: Fourteen New Zealand White rabbits (weighing 3.0-4.5 kg). INTERVENTIONS: The animals were ventilated with an FIO(2) of 1.0 before induction of acute lung injury. Acute lung injury was induced by repeated saline lung lavages. Eight rabbits were randomized to 60 mins of treatment with an inspiratory perfluorohexane vapor concentration of 0.2 in oxygen. To compensate for the reduced FIO(2) during perfluorohexane treatment, FIO(2) was reduced to 0.8 in control animals. Change in relative pulmonary blood flow distribution was assessed by using fluorescent-labeled microspheres. MEASUREMENTS AND MAIN RESULTS: Microsphere data showed a redistribution of relative pulmonary blood flow attributable to depletion of surfactant. Relative pulmonary blood flow shifted from areas that were initially high-flow to areas that were initially low-flow. During the study period, relative pulmonary blood flow of high-flow areas decreased further in the control group, whereas it increased in the treatment group. This difference was statistically significant between the groups (p =.02) as well as in the treatment group compared with the initial injury (p =.03). Shunt increased in both groups over time (control group, 30% +/- 10% to 63% +/- 20%; treatment group, 37% +/- 20% to 49% +/- 23%), but the changes compared with injury were significantly less in the treatment group (p =.03). CONCLUSION: Short treatment with perfluorohexane vapor partially reversed the shift of relative pulmonary blood flow from high-flow to low-flow areas attributable to surfactant depletion.

NASA Discipline Cardiopulmonary↗

NMR of laser-polarized 129Xe in blood foam

Laser-polarized 129Xe dissolved in a foam preparation of fresh human blood was investigated. The NMR signal of 129Xe dissolved in blood was enhanced by creating a foam in which the dissolved 129Xe exchanged with a large reservoir of gaseous laser-polarized 129Xe. The dissolved 129Xe T1 in this system was found to be significantly shorter in oxygenated blood than in deoxygenated blood. The T1 of 129Xe dissolved in oxygenated blood foam was found to be approximately 21 (+/-5) s, and in deoxygenated blood foam to be greater than 40 s. To understand the oxygenation trend, T1 measurements were also made on plasma and hemoglobin foam preparations. The measurement technique using a foam gas-liquid exchange interface may also be useful for studying foam coarsening and other liquid physical properties.

Non-NASA Center↗

Multiplex detection and identification of viral, bacterial, and protozoan pathogens in human blood and plasma using an expanded high-density resequencing microarray platform

Introduction: Nucleic acid tests for blood donor screening have improved the safety of the blood supply; however, increasing numbers of emerging pathogen tests are burdensome. Multiplex testing platforms are a potential solution. Methods: The Blood Borne Pathogen Resequencing Microarray Expanded (BBP-RMAv.2) can perform multiplex detection and identification of 80 viruses, bacteria and parasites. This study evaluated pathogen detection in human blood or plasma. Samples spiked with selected pathogens, each with one of 6 viruses, 2 bacteria and 5 protozoans were tested on this platform. The nucleic acids were extracted, amplified using multiplexed sets of primers, and hybridized to a microarray. The reported sequences were aligned to a database to identify the pathogen. To directly compare the microarray to an emerging molecular approach, the amplified nucleic acids were also submitted to nanopore next generation sequencing (NGS). Results: The BBP-RMAv.2 detected viral pathogens at a concentration as low as 100 copies/ml and a range of concentrations from 1,000 to 100,000 copies/ml for all the spiked pathogens. Coded specimens were identified correctly demonstrating the effectiveness of the platform. The nanopore sequencing correctly identified most samples and the results of the two platforms were compared. Discussion: These results indicated that the BBP-RMAv.2 could be employed for multiplex detection with potential for use in blood safety or disease diagnosis. The NGS was nearly as effective at identifying pathogens in blood and performed better than BBP-RMAv.2 at identifying pathogen-negative samples.

59 BASIC BIOLOGICAL SCIENCES↗

Limb blood flow - Rest and heavy exercise in sitting and supine positions in man

The objectives of the study were twofold: (1) to determine the effect of body position (hydrostatic pressure) on total blood flow in active and passive limbs at rest and after severe exercise; and (2) to further evaluate the impedance technique for measurement of blood flow. To this end, the effect of body position on the redistribution of total blood flow in active (leg) and passive (forearm) limbs during exercise was determined by measuring total limb impedance (blood flow) in five male and one female subjects in sitting and supine positions with a modified Beckman BR-100 rheograph. The results show that, at rest and after exercise, the supine position induces significantly greater flows in the leg but not in the forearm. With severe exercise, blood flows are increased in both passive and active limbs, so that there is probably no net transfer of blood volume from passive to active muscles. The advantages of the impedance technique over other methods are stressed.

Greenleaf, J. E.↗

Blood Pump Development Using Rocket Engine Flow Simulation Technology

This paper reports the progress made towards developing complete blood flow simulation capability in humans, especially in the presence of artificial devices such as valves and ventricular assist devices. Devices modeling poses unique challenges different from computing the blood flow in natural hearts and arteries. There are many elements needed to quantify the flow in these devices such as flow solvers, geometry modeling including flexible walls, moving boundary procedures and physiological characterization of blood. As a first step, computational technology developed for aerospace applications was extended to the analysis and development of a ventricular assist device (VAD), i.e., a blood pump. The blood flow in a VAD is practically incompressible and Newtonian, and thus an incompressible Navier-Stokes solution procedure can be applied. A primitive variable formulation is used in conjunction with the overset grid approach to handle complex moving geometry. The primary purpose of developing the incompressible flow analysis capability was to quantify the flow in advanced turbopump for space propulsion system. The same procedure has been extended to the development of NASA-DeBakey VAD that is based on an axial blood pump. Due to massive computing requirements, high-end computing is necessary for simulating three-dimensional flow in these pumps. Computational, experimental, and clinical results are presented.

Kwak, Dochan↗

Automated Blood Pressure Measurement

The Vital-2 unit pictured is a semi-automatic device that permits highly accurate blood pressure measurement, even by untrained personnel. Developed by Meditron Instrument Corporation, Milford, New Hampshire, it is based in part on NASA technology found in a similar system designed for automatic monitoring of astronauts' blood pressure. Vital-2 is an advancement over the familiar arm cuff, dial and bulb apparatus customarily used for blood pressure checks. In that method, the physician squeezes the bulb to inflate the arm cuff, which restricts the flow of blood through the arteries. As he eases the pressure on the arm, he listens, through a stethoscope, to the sounds of resumed blood flow as the arteries expand and contract. Taking dial readings related to sound changes, he gets the systolic (contracting) and diastolic (expanding) blood pressure measurements. The accuracy of the method depends on the physician's skill in interpreting the sounds. Hospitals sometimes employ a more accurate procedure, but it is "invasive," involving insertion of a catheter in the artery.

Source record↗

Improved Whole-Blood-Staining Device

Dramatic improvements have been made in NASA s Whole Blood Staining Device (WBSD) since it was last described in "Whole-Blood-Staining Device," NASA Tech Briefs, Vol. 23, No. 10 (October 1999), page 64. The new system has a longer shelf life, a simpler and more effective operational procedure, improved interface with instrumentation, and shorter processing time. More specifically, the improvements have targeted bag and locking clip materials, sampling ports, and air pocket prevention. The WBSD stains whole blood collected during spaceflight for subsequent flow cytometric analysis. In short, the main device stains white blood cells by use of monoclonal antibodies conjugated to various fluorochromes, followed by lysing and fixing of the cells by use of a commercial reagent that has been diluted according to NASA safety standards. This system is compact, robust, and does not require electric power, precise mixing, or precise incubation times. Figure 1 depicts the present improved version for staining applications, which is a poly(tetrafluoroethylene) bag with a Luer-lock port and plastic locking clips. An InterLink (or equivalent) intravenous- injection port screws into the Luer-lock port. The inflatable/collapsible nature of the bag facilitates loading and helps to minimize the amount of air trapped in the fully loaded bag. Some additional uses have been identified for the device beyond whole blood staining. The WBSD has been configured for functional assays that require culture of live cells by housing sterile culture media, mitogens, and fixatives prior to use [Figure 2(a)]. Simple injection of whole blood allows cell-stimulation culture to be performed in reduced gravity conditions, and product stabilization prior to storage, while protecting astronauts from liquid biohazardous materials. Also, the improved WBSD has reconstituted powdered injectable antibiotics by mixing them with diluent liquids [Figure 2(b)]. Although such mixing can readily be performed on Earth by shaking in glass vials, it cannot readily be performed this way in outer space without entraining air bubbles. The present device can be preloaded with the powder and diluent(s) in separate compartments. The powder and diluent( s) can be mixed, without introducing air bubbles, by removing the clip(s), then shaking. This use of the device could also be advantageous in terrestrial applications because it maintains the isolation of the constituents until the time of use.

Sams, Clarence F.↗

Beat-to-Beat Blood Pressure Monitor

This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes.

Lee, Yong Jin↗

Transcriptomic Changes in Peripheral Blood Mononuclear Cells of International Space Station Crewmembers

In space, living organisms are exposed to numerous stress factors including microgravity and space radiation. For humans, these harmful environmental factors have been known to cause negative health impacts such as immune dysfunction. Understanding the mechanisms by which spaceflight impacts human health at the molecular level is critical not only for accurately assessing the risks associated with spaceflight, but also for developing effective countermeasures. This study is part of the Functional Immune Project, intended to determine alterations in crewmembers` immunobiology before, during, and after spaceflight. For this project, blood samples were collected from International Space Station (ISS) crewmembers at the following time points: i) Blood was drawn at two pre-flight time points of 180 days (L180) and 45 days (L45) before launch. ii) During flight, blood was drawn at approximately the midpoint (mid-flight, MF) of the mission, and shortly before egress from the ISS (late-flight, LF). iii) Post-flight blood samples were collected within 36 hours (R0), 30 days (R30) and 90 days (R90) after landing. For each crewmember, blood was also drawn from a matching test subject on the ground at the corresponding time point. For both the ISS crewmembers and the ground control subjects, total RNA was isolated from peripheral blood mononuclear cells (PBMC) and mRNA was analysed using next generation RNA-sequencing (NGS). Differentially expressed genes were determined by performing contrast analysis. Using the ground control subjects of all time points combined as a control, a number of dysregulated genes were identified in astronauts at MF, LF and R0, including downregulations of SMAD7 and CDKN1A at MF and LF. Some of the genes such as SERPINE1 and VEGFA were downregulated at MF and LF, but upregulated at R0, while others such as NKG7 were down regulated at all 3 time points. Pathway analysis of these differentially expressed genes indicated that the NF-κB pathway was chronically activated in space. Analysis of the consequent diseases suggested potential associations with not only immune dysfunction, but also other health risks including osteoarthritis, cardiac hypertrophy and neuroinflammation.

Maria Moreno-Villanueva↗

Transcriptomic Changes in ISS Crewmembers Suggest Decreased Metabolic Activity in Peripheral Blood Mononuclear Cells

In space, living organisms are exposed to numerous stress factors including microgravity and space radiation. For humans, these harmful environmental factors have been known to cause negative health impacts such as immune dysfunction. Understanding the mechanisms by which spaceflight impacts human health at the molecular level is critical not only for accurately assessing the risks associated with spaceflight, but also for developing effective countermeasures. This study is part of the Functional Immune Project, intended to determine alterations in crewmembers` immunobiology before, during, and after spaceflight. For this project, blood samples were collected from International Space Station (ISS) crewmembers at the following time points: i) Blood was drawn at two pre-flight time points of 180 days (L180) and 45 days (L45) before launch. ii) During flight, blood was drawn at approximately the midpoint (mid-flight, MF) of the mission, and shortly before egress from the ISS (late-flight, LF). iii) Post-flight blood samples were collected within 36 hours (R0), 30 days (R30) and 90 days (R90) after landing. For each crewmember, blood was also drawn from a matching test subject on the ground at the corresponding time point. For both the ISS crewmembers and the ground control subjects, total RNA was isolated from peripheral blood mononuclear cells (PBMC) and mRNA was analysed using next generation RNA-sequencing (NGS). Differentially expressed genes were determined by performing contrast analysis. Using the ground control subjects of all time points combined as a control, a number of dysregulated genes were identified in astronauts at MF, LF and R0, Pathway analysis of these differentially expressed genes indicated that several of the pathways related to metabolism, including LXR/RXR, NAD signaling and fatty acid betta-oxidation, were downregulated at MF and LF. We suggest that the decreased metabolic activity in space may contribute to the immune dysfunction and delayed cell cycle progression as observed in the astronauts.

Maria Moreno-Villanueva↗

Transcriptomic Analysis of ISS Crewmembers’ Peripheral Blood Mononuclear Cells Reveals Homeostatic Regulations in Space

The impact of spaceflight on the immune system has been investigated for decades. Studies conducted in cell models, animals and humans suggest that the spaceflight environment affects the innate and acquired immune systems, as the ability to recognize antigens, defend against foreign invaders, and orchestrate repair is significantly hindered. However, the molecular mechanisms behind spaceflight-induced immune dysregulations are still unclear. In this study, blood from eleven (11) International Space Station (ISS) crewmembers was collected before, during and after long duration space missions, as well as from 11 matched ground control subjects. Transcriptomic analysis was performed in isolated peripheral blood mononuclear cells (PBMCs) using the RNA-sequencing technique. In comparison to the blood samples collected from the crewmembers pre-flight, a total of ~1000 genes were found to be upregulated and ~1000 genes downregulated in PBMC collected between 4 and 6 months after they were in space. The most significantly DEGs (differentially expressed genes) include activation of RUBCNL which is an autophagy enhancer and inhibition of GRASP which regulates cell trafficking. Genes involved in cell adhesion, cell cycle progression and other functions were also dysregulated. Pathway analysis of the DEGs indicates mitochondria dysfunction, particularly reduced ATP production in the electron transport chain. Other pathways impacted by spaceflight include glycolysis, autophagy and inflammatory response. Our results suggest that, in space, blood cells may have also experienced energy depletion and reduced metabolism. Consequently, the cells may become autophagic, which is a known homeostatic mechanism for blood cells to become quiescent, but to stay alive. Further analysis of the data shows recovery of the crewmembers after mission and potential differential responses between genders to the space environment. Our data potentially explains some of the physiological changes that have been observed in space such as mitochondria dysfunction, inhibition of T cell activation and telomere lengthening. Comparison of our results with other transcriptomics studies of ISS crewmembers’ blood cells will also be presented.

Maria Moreno Villanueva↗

Exercise increases blood flow to locomotor, vestibular, cardiorespiratory and visual regions of the brain in miniature swine

1. The purpose of these experiments was to use radiolabelled microspheres to measure blood flow distribution within the brain, and in particular to areas associated with motor function, maintenance of equilibrium, cardiorespiratory control, vision, hearing and smell, at rest and during exercise in miniature swine. Exercise consisted of steady-state treadmill running at intensities eliciting 70 and 100 % maximal oxygen consumption (V(O(2),max)). 2. Mean arterial pressure was elevated by 17 and 26 % above that at rest during exercise at 70 and 100 % V(O(2),max), respectively. 3. Mean brain blood flow increased 24 and 25 % at 70 and 100 % V(O(2),max), respectively. Blood flow was not locally elevated to cortical regions associated with motor and somatosensory functions during exercise, but was increased to several subcortical areas that are involved in the control of locomotion. 4. Exercise elevated perfusion and diminished vascular resistance in several regions of the brain related to the maintenance of equilibrium (vestibular nuclear area, cerebellar ventral vermis and floccular lobe), cardiorespiratory control (medulla and pons), and vision (dorsal occipital cortex, superior colliculi and lateral geniculate body). Conversely, blood flow to regions related to hearing (cochlear nuclei, inferior colliculi and temporal cortex) and smell (olfactory bulbs and rhinencephalon) were unaltered by exercise and associated with increases in vascular resistance. 5. The data indicate that blood flow increases as a function of exercise intensity to several areas of the brain associated with integrating sensory input and motor output (anterior and dorsal cerebellar vermis) and the maintenance of equilibrium (vestibular nuclei). Additionally, there was an intensity-dependent decrease of vascular resistance in the dorsal cerebellar vermis.

Non-NASA Center↗