Reuse of Treated Internal or External Wastewaters in the Cooling Systems of Coal-Based Thermoelectric Power Plants

This study evaluated the feasibility of using three impaired waters - secondary treated municipal wastewater, passively treated abandoned mine drainage (AMD), and effluent from ash sedimentation ponds at power plants - for use as makeup water in recirculating cooling water systems at thermoelectric power plants. The evaluation included assessment of water availability based on proximity and relevant regulations as well as feasibility of managing cooling water quality with traditional chemical management schemes. Options for chemical treatment to prevent corrosion, scaling, and biofouling were identified through review of current practices, and were tested at bench and pilot-scale. Secondary treated wastewater is the most widely available impaired water that can serve as a reliable source of cooling water makeup. There are no federal regulations specifically related to impaired water reuse but a number of states have introduced regulations with primary focus on water aerosol 'drift' emitted from cooling towers, which has the potential to contain elevated concentrations of chemicals and microorganisms and may pose health risk to the public. It was determined that corrosion, scaling, and biofouling can be controlled adequately in cooling systems using secondary treated municipal wastewater at 4-6 cycles of concentration. The high concentration of dissolved solids in treated AMD rendered difficulties in scaling inhibition and requires more comprehensive pretreatment and scaling controls. Addition of appropriate chemicals can adequately control corrosion, scaling and biological growth in ash transport water, which typically has the best water quality among the three waters evaluated in this study. The high TDS in the blowdown from pilot-scale testing units with both passively treated mine drainage and secondary treated municipal wastewater and the high sulfate concentration in the mine drainage blowdown water were identified as the main challenges for blowdown disposal. Membrane treatment (nanofiltration or reverse osmosis) can be employed to reduce TDS and sulfate concentrations to acceptable levels for reuse of the blowdown in the cooling systems as makeup water.

01 COAL, LIGNITE, AND PEAT↗

Simplified Analysis of Pulse Detonation Rocket Engine B1owdown Gasdynamics and Performance

Pulsed detonation rocket engines (PDREs) have generated considerable research interest in recent years as a chemical propulsion system potentially offering improved performance and reduced complexity compared to conventional rocket engines. The detonative mode of combustion employed by these devices offers a thermodynamic advantage over the constant-pressure deflagrative combustion mode used in conventional rocket engines and gas turbines. However, while this theoretical advantage has spurred a great deal of interest in building PDRE devices, the unsteady blowdown process intrinsic to the PDRE has made realistic estimates of the actual propulsive performance problematic. The recent review article by Kailasanath highlights some of the difficulties in comparing the available experimental measurements with numerical models. The goal of this paper is to improve understanding of PDRE blowdown gasdynamics and performance issues through use of a simplified model that captures the essential features of the unsteady blowdown process, and yet remains computationally inexpensive. The PDRE system studied here is highly idealized, consisting of a constant-area detonation tube with one end closed and the other end open to the environment. The tube is prefilled with a gaseous propellant mixture with no initial velocity or outflow to the environment. The detonation is initiated instantaneously at the closed end of the device. Chapman-Jouguet (C-J) post-detonation gas conditions are calculated using the CET89 version of the NASA thermochemical code. The I-D, unsteady method of characteristics is used to calculate the flowfield following the detonation front. See the compressible flow texts by Thompson and Zucrow and Hoffman for details of this method. Parametric studies of the effect of mixture stoichiometry, fill temperature, and blowdown pressure ratio on performance are reported. A comparison of the performance of an idealized straight-tube PDRE with a conventional steady-state rocket engine is provided. The effect of constant-gamma and equilibrium chemistry assumptions is also examined. Additionally, in order to form an assessment of the accuracy of the model, the flowfield time history is compared to experimental data from Stanford University.

Morris, Christopher I.↗

Application of Pulse Spark Discharges for Scale Prevention and Continuous Filtration Methods in Coal-Fired Power Plant

The overall objective of the present work was to develop a new scale-prevention technology by continuously precipitating and removing dissolved mineral ions (such as calcium and magnesium) in cooling water while the COC could be doubled from the present standard value of 3.5. The hypothesis of the present study was that if we could successfully precipitate and remove the excess calcium ions in cooling water, we could prevent condenser-tube fouling and at the same time double the COC. The approach in the study was to utilize pulse spark discharges directly in water to precipitate dissolved mineral ions in recirculating cooling water into relatively large suspended particles, which could be removed by a self-cleaning filter. The present study began with a basic scientific research to better understand the mechanism of pulse spark discharges in water and conducted a series of validation experiments using hard water in a laboratory cooling tower. Task 1 of the present work was to demonstrate if the spark discharge could precipitate the mineral ions in water. Task 2 was to demonstrate if the self-cleaning filter could continuously remove these precipitated calcium particles such that the blowdown could be eliminated or significantly reduced. Task 3 was to demonstrate if the scale could be prevented or minimized at condenser tubes with a COC of 8 or (almost) zero blowdown. In Task 1, we successfully completed the validation study that confirmed the precipitation of dissolved calcium ions in cooling water with the supporting data of calcium hardness over time as measured by a calcium ion probe. In Task 2, we confirmed through experimental tests that the self-cleaning filter could continuously remove precipitated calcium particles in a simulated laboratory cooling tower such that the blowdown could be eliminated or significantly reduced. In addition, chemical water analysis data were obtained which were used to confirm the COC calculation. In Task 3, we conducted a series of heat transfer fouling tests using a condenser heat exchanger in the laboratory cooling tower, from which we confirmed that the plasma water treatment technology could prevent or significantly mitigate mineral foulings in condenser tubes when compared with the no-treatment case. With the completion of the present work, a cooling water treatment technology using pulse spark discharges is currently ready for field-validation tests. The plasma water treatment technology is a true mechanical water softener with almost no maintenance, which continuously converts hard water to soft water spending a relatively small amount of energy. Such a mechanical water softener could find wide-spread applications to solve hard water problems both in industry and at home.

20 FOSSIL-FUELED POWER PLANTS↗

Intensified Flue Gas Desulfurization Water Treatment for Reuse, Solidification, and Discharge

The goal of this final project report is to summarize the work conducted on project DE-FE0031555. In accordance with the Statement of Project Objectives (SOPO), the University of Kentucky Center for Applied Energy Research (UK CAER) (Recipient) developed a hybrid electrochemical-membrane technology for treating wet flue gas desulfurization (WFGD) blowdown from coal-fired power generation plants that (1) removes government-regulated species and total suspended solids (TSS) via electrocoagulation with solid/liquid separation to avoid further treatments by a biological method specifically for selenium, and (2) reduces total dissolved solids (TDS) in a nanofiltration unit to promote water recycle and reduce freshwater intake. Additional technological configurations were pursued, including (1) nanofiltration combined with zeolite dewatering for a near-zero liquid discharge (ZLD) scenario, and (2) polishing discharge from zeolite dewatering using capacitive deionization (CDI) with 90+% salt rejection to produce water with less than 100ppm TDS for more beneficial use. Project results verified that UK CAER’s hybrid approach addressed the complexities of WFGD blowdown with simplified unit operation at relatively low capital investment by demonstrating: (1) an effective in-situ generated solid sorbent material, green-rust (GR), that specifically removes regulated dissolved species in WFGD blowdown, including selenium, arsenic, and nitrates; (2) a low-cost, high flux nanofiltration treatment that removes both monovalent and divalent species at >80% rejection to adequately provide water recycle and extend the life of FGD equipment by mitigating chloride aided pitting corrosion mechanisms; and (3) a solidification and stabilization process using pozzolanic agents that retain regulated species and satisfy the Resource Conservation and Recovery Act (RCRA) leachate requirements. UK CAER proved electrocoagulation with GR to be an intensified solution for effluent limit guidelines (ELG), and based on preliminary techno-economic analysis (TEA), in comparison to DOE’s Case 1 for Biological Wastewater Treatment that had a purchased equipment cost (PEC) of $\$$5.26 million and a Total plant cost (TPC) of $\$$30.0 million, the EC process had a PEC of $\$$2.67 million and the TPC of $\$$17.0 million. While the electricity consumption for Case 1 was 53 kW, it was 110 kW for the EC process due to dissolving iron for a three-stage reaction design. However, electricity consumption for the EC process could be significantly reduced by adopting a counter-current reactor design for at least a 6-stage chemical reaction operation.

01 COAL, LIGNITE, AND PEAT↗

Wastewater Recycling Using a Hygroscopic Cooling System

This project by the Energy & Environmental Research Center (EERC), Baltimore Aircoil Company (BAC), and Great River Energy (GRE) evaluated the concept of recycling wastewater at a coal-fired power plant using a hygroscopic cooling system, which is an evaporative cooling technology analogous to conventional cooling towers, except that sparingly soluble dissolved solids are precipitated and removed as waste solids instead of purging them with a liquid blowdown stream. This technology can maximize the use of plant makeup water by obtaining useful evaporative cooling from wastewater while minimizing the volume of wastes needing disposal. Experimental activities were conducted in two phases, a laboratory-based evaluation of the properties of wastewater from the host site, GRE’s Coal Creek Station near Underwood, North Dakota, and a field test of a small pilot hygroscopic cooling system at the host site power plant. Findings from the laboratory study informed the design of the pilot system and the system’s field test performance served as the basis for a techno-economic analysis (TEA) of the hygroscopic recycling concept. At the preferred operating conditions identified during the TEA, the wet-bulb approach temperature of the tower was 7.3°C (13°F) and the volume of blowdown produced by the plant was reduced to 5.4% of its incoming volume. Waste solids produced during field testing were classified as nonhazardous waste based on the measured hazardous element content and evaluation of their leaching potential. However, to qualify as a solid for landfill disposal i.e., as determined by the U.S. Environmental Protection Agency’s paint filter test, it appears that a dewatering step beyond hydrocyclone separation is needed. The baseline levelized cost of wastewater disposal (LCWD) for hygroscopic wastewater recycling was estimated to be $\$ $3.69–$\$ $3.72 per m3 of plant blowdown. Capital cost was estimated to contribute over 54% to the LCWD, and parameters that impact capital cost such as the heat exchange coil material of construction and the tower’s wet-bulb approach temperature were identified as having the greatest impact on overall LCWD. A LCWD estimate prepared for the same application but using thermomechanical brine evaporation was almost 40% higher than that calculated for hygroscopic cooling, despite recovering distilled-quality water for reuse, while the LCWD for disposal-only, deep well injection was estimated to be 30% lower compared to hygroscopic wastewater recycling.

01 COAL, LIGNITE, AND PEAT↗

Quasi-One-Dimensional Modeling of Pulse Detonation Rocket Engines

Pulsed detonation rocket engines (PDREs) have generated considerable research interest in recent years as a chemical propulsion system potentially offering improved performance and reduced complexity compared to conventional rocket engines. The detonative mode of combustion employed by these devices offers a thermodynamic advantage over the constant-pressure deflagrative combustion mode used in conventional rocket engines and gas turbines. However, while this theoretical advantage has spurred a great deal of interest in building PDRE devices, the unsteady blowdown process intrinsic to the PDRE has made realistic estimates of the actual propulsive performance problematic. The recent review article by Kailasanath highlights some of the difficulties in comparing the available experimental measurements with numerical models. In a previous paper by the author, parametric studies of the performance of a single, straight-tube PDRE were reported. A 1-D, unsteady method of characteristics code, employing a constant-gamma assumption behind the detonation front, was developed for that study. Models of this type are computationally inexpensive, and are particularly useful for parametric performance comparisons. For example, a plot showing the specific impulse of various PDRE and steady-state rocket engine (SSRE) configurations as a function of blowdown pressure ratio. The performance curves clearly indicate that a straight-tube PDRE is superior in specific impulse to a SSRE with a sonic nozzle over the entire range of pressure ratios. Note, however, that a straight-tube PDRE in general does not compare favorably to a SSRE fitted with an optimized de Laval supersonic nozzle, particularly at the high pressure ratios typical for boost or in-space rocket applications. However, the calculations also show that if a dynamically optimized, supersonic de Laval nozzle could be could be fitted to a PDRE, then the specific impulse of the device would exceed that of a comparable SSRE. While such a nozzle is a considerable idealization, it is clear that nozzle design and optimization will play a critical role in whether the performance potential of PDREs can be effectively realized in practice. In order to study PDRE nozzle issues with greater accuracy, a quasi-one-dimensional, finite-rate chemistry CFD code has been developed by the author. Comparisons of the code with both the previous MOC model and experimental data from Stanford University are reported. The effect of constant-gamma and finite-rate chemistry assumptions on the flowfield and performance is examined. Parametric studies of the effect of nozzle throat size and expansion ratio, at various blowdown pressure ratios, are reported.

Morris, Christopher I.↗

Analysis of Hydrology and Interim Measure Performance in the Chromium Plume at Los Alamos National Laboratory - 20498

Hexavalent chromium, Cr(VI), is present in the regional aquifer beneath Los Alamos National Laboratory (LANL) at concentrations greater than the New Mexico groundwater standard (50 ppb). The source of the Cr is blowdown from a power plant where potassium dichromate was used as a corrosion inhibitor from 1956 to 1972. Blowdown comingled with effluent from another source and migrated approximately 3 miles down a canyon, primarily as surface flow, until reaching an alluvial infiltration zone. The infiltrating water moved vertically through a thick (approximately 900 ft), complex stratigraphic sequence of unsaturated tuffs, basalt, and unconsolidated alluvial deposits. Horizontal transport also took place within spatially limited perched groundwater horizons in the vadose zone (VZ). Breakthrough at the regional aquifer water table is thought to have occurred in multiple hydraulic windows or 'drip points' located approximately 3 miles from the initial release site at the power plant. The regional aquifer is highly heterogeneous and anisotropic, and displays unconfined behavior in an upper zone and confined behavior at depth. The Cr(VI) contamination has so far remained confined to the upper approximately 25 m of the aquifer. The ambient hydraulic gradient in the regional aquifer is toward the east/southeast, but the water table is extremely flat in the Cr plume area compared to surrounding areas. There is some local variability in flow direction, potentially related to effects of seasonal pumping from nearby Los Alamos county water-supply wells, which draw from the regional aquifer several hundred feet below the water table. An interim measure (IM) is currently operating at the site to achieve hydraulic control of plume migration using a series of extraction wells, ion-exchange treatment, and injection along the downgradient portion of the plume. The migration of Cr contamination in the aquifer has been previously evaluated using a calibrated probabilistic numerical model, which has also been used to design the spatial configuration of extraction and injection wells for the IM, and to identify locations for monitoring wells. The model is built using the Finite Element Heat and Mass (FEHM) transfer code, and the Model Analysis and Decision Support (MADS) software is used for analyses. To date, the portion of the IM system that has operated in a continuous manner has been very effective at hydraulic control. Modifications to the flow field associated with the influence of IM pumping and injection are evaluated here, with modeling constraints to be provided by recent observations of tracers injected into both monitoring wells and IM injection wells, as well as opportunistic observations of geochemical signatures of treated ion-exchange effluent injected into IM injection wells. The tracer and geochemical data provide insights into modified flow directions within the Cr plume area that cannot be otherwise obtained. Results of the modeling work are being used to inform adaptive management of IM operations and will be a valuable tool for development and refinement of long-term remediation strategies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Informing hazardous zones for on-board maritime hydrogen liquid and gas systems

The significantly higher buoyancy of hydrogen compared to natural gas means that hazardous zones defined in the IGF code may be inaccurate if applied to hydrogen. This could place undue burden on ship design or could lead to situations that are unknowingly unsafe. We present dispersion analyses to examine three vessel case studies: (1) abnormal external vents of full blowdown of a liquid hydrogen tank due to a failed relief device in still air and with crosswind; (2) vents due to naturally-occurring boil-off of liquid within the tank; and (3) a leak from the pipes leading into the fuel cell room. The size of the hydrogen plumes resulting from a blowdown of the tank depend greatly on the wind conditions. It was also found that for normal operations releasing a small amount of "boil- off" gas to regulate the pressure in the tank does not create flammable concentrations.

08 HYDROGEN↗

An Assessment of MELCOR 2.1: Containment Thermal-Hydraulic Tests in the Heissdampfreaktor (HDR) Facility

MELCOR is being developed at Sandia National Laboratories for the U.S. Nuclear Regulatory Commission. MELCOR is a fully integrated code (encompassing the reactor coolant system and the containment building) that models the progression of postulated accidents in light water reactor power plants. It provides a capability for independently auditing analyses submitted by reactor manufacturers and utilities. In order to assess the adequacy of containment thermal - hydraulic modeling incorporated in the MELCOR code, a key containment test facility was analyzed. This report documents MELCOR code calculations for simulating steam - water blowdown tests performed in the Heissdampfreaktor ( HDR) de-commissioned containment facility located near Frankfurt , Germany . These tests are a series of blowdown experiments in a large scaled test facility ; including some tests with the addition of hydrogen release which are intended to simulate a variety of postulated break s inside large containment buildings. The key objectives of this MELCOR assessment are to study: (1) the expansion and transport of high energy steam - water releases, (2) heat and mass transfer to structural passive heat sinks, and (3) containment gas mixing and stratification. Moreover, MELCOR results are compared to the CONTAIN code for the same tests.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Electrochemical Water Treatment for Cooling Towers

Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. They are the point in the system where heat is dissipated to the atmosphere through the evaporative cooling process. Cooling towers are commonly found in industrial applications and are also commonly applied to water cooled chilled water plants in medium to large commercial buildings. Cooling towers used in medium to large commercial buildings are the focus of this paper. Cooling towers consume a large amount of water. Cooling tower related water consumption is one of largest potable water loads within buildings in the United States, with over 26% of water use associated with heating and cooling. Reducing water consumption is a priority for the General Services Administration (GSA) due to Executive Order 13514, Energy Policy Act of 1992, and regional water shortage concerns. These factors have brought about the investigation of cost effective opportunities to reduce water use, such as alternative water treatment (AWT) technologies for cooling towers. Traditional water treatment approaches rely on chemicals to extend the ability of the water to hold scaling minerals in suspension, minimize corrosion, and prevent biological growth. This treatment protects the chillers and cooling tower equipment, however even when chemicals are used regularly, a certain percentage of condenser water must be blown down and made up with fresh water to maintain system water quality parameters. In addition, the use of chemicals sometimes creates a waste issue and can cause building owners to incur additional fees such as disposal or sewer charges. The current state of water treatment in GSA buildings is to contract for a fixed fee with a company specializing in a conventional chemical maintenance. There are many vendors of AWT systems. This project assesses the effectiveness of one technology provided by Dynamic Water Technologies (DWT). This project assesses the effectiveness of DWT for lowering GSA operating costs while maintaining proper water treatment. The application of the DWT technology in place of traditional chemical water treatment has the anticipated benefits of: - Saving water and water/sewer costs by reducing the amount of blowdown required due to being able to remove scale causing minerals that allows the system to operate at a higher cycles of concentration - Eliminating the need for water treatment chemicals for scale, corrosion, and biological growth - Increasing chiller efficiency by preventing scaling and removing some of the existing scale, which improves heat transfer - Maintaining very low corrosion rates. The technology was installed at the Juliette Gordon Low Federal Building located in Savannah, Georgia. The building has two cooling towers utilizing traditional chemical water treatment for the cooling water circulating through the two chiller condensers. Measurement at the site includes the flow of makeup water to the cooling towers and the blowdown flow rate from the cooling tower basins. Additionally, energy measurements include the electrical energy from the chillers, chiller water pumps, condenser water pumps, cooling tower fans and the energy used by the DWT skid and slip stream pump.

15 GEOTHERMAL ENERGY↗

Permeation testing of thermal power plant cooling water impacts of Graphite Oxide (GO)/polymer membranes

The purpose of this project was to investigate how thermoelectric power plant cooling water impacts the energy demands, permeance, and ion rejection of GO/polymer membranes using extended permeation testing. Treatment of cooling tower blowdown water is challenging since this water contains scalants (e.g.: silica, calcium sulfate, calcium carbonate) which can precipitate on membranes, decreasing membrane efficiency and lifetime. In this collaboration with EPRI and a Southwestern US utility, the performance of GO/polymer membranes in desalinating cooling tower blowdown water from three natural-gas fueled power plants was evaluated. Results of cross-flow desalination test durations of three to four weeks demonstrated the long-term stability of the membranes. GO/polymer desalination membranes were shown to tolerate drinking-water level chlorination, which could reduce capital and operational costs. Biofouling and scale formation were minimal on the GO surface, suggesting that industry standard intensive cleaning steps could be reduced. Results also demonstrated pressure-tunable rejection which would allow treat-to-need water recycling, thus likely reducing energy costs for these membranes. Further development of biofouling and scaling resistant desalination membranes could lead to reduced cost for water treatment, potentially allowing for greater use of non-traditional water supplies for thermoelectric power plants.

Biedermann, Laura↗

Continuous Monitoring and Partial Water Softening for Cooling Tower Water Treatment

Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. They are the point in the system where heat is dissipated to the atmosphere through the evaporative cooling process. Cooling towers are commonly found in industrial applications and are also often used in water-cooled chilled water plants in medium to large commercial buildings. Continuous monitoring and partial water softening for cooling towers used in medium to large commercial buildings are the focus of this paper. Cooling towers consume large amounts of water. Cooling tower-related water consumption is one of largest potable water loads within buildings in the United States, with substantial building water use associated with heating and cooling. Regional water shortages have highlighted a need to reduce water consumption; the U.S. General Services Administration (GSA) and Executive Order 13834 place priority on reducing water consumption. This priority has fueled interest in the identification, investigation, and potential broad deployment of cost-effective opportunities to reduce water use, such as alternative water treatment (AWT) technologies for cooling towers. Traditional water treatment approaches use chemicals to extend the ability of the water to hold scaling minerals in suspension, minimize corrosion, and prevent biological growth. This treatment protects the chillers and cooling tower equipment; however, even when chemicals are used regularly, a certain percentage of condenser water must be drained and made up with fresh water to maintain system water quality parameters. In addition, the use of chemicals sometimes creates a waste disposal issue and can cause building owners to incur additional fees, such as disposal or wastewater charges. To manage cooling tower water treatment, GSA typically contracts with a company specializing in conventional chemical maintenance for a fixed fee. While there are many types and vendors of AWT systems, this project assesses the effectiveness of one technology provided by Aqualogix. This system is a chilled water plant monitoring and control system aimed at optimizing system performance by reducing the blowdown occurrences used to remove mineral build-up. The technology consists of two components – continuous programmable logic control (PLC) monitoring and side-stream filtration with partial water softening. PLC monitoring calculates cycles of concentration (CoC) and determines the optimum amount of blowdown water required to satisfy all water chemistry requirements. Side-stream filtration removes suspended matter and improves biocide efficacy while precisely dispensing softened water to achieve optimal makeup water hardness. Unlike other AWT systems evaluated by GSA to date, this system does not replace the legacy treatment system but is used in addition to chemical water treatment. The vendor claims their technology will reduce water consumption, water discharge, and maintenance costs. The AWT system evaluated in this demonstration is a commercialized technology. Given its commercialized state, the system evaluated in this report is at a Technology Readiness Level 9 according to National Aeronautics and Space Administration (NASA) definitions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Validation and Comparison of HyRAM Physics Models

The Hydrogen Risk Assessment Models (HyRAM) software version 3 uses a real gas equation of state rather than the Abel-Noble equation of state that is used in 2.0 and previous versions. This change enables the use of HyRAM 3 for cryogenic hydrogen flows, whereas the Abel-Noble equation of state is not accurate at low temperatures. HyRAM 3.1 results were compared to experimental data from the literature in order to demonstrate the accuracy of the physics models. HyRAM 3.1 results were also compared to HyRAM 2.0 for high-pressure, non-cryogenic flows to highlight the differences in predictions between the two major versions of HyRAM. Validation data sets are from multiple groups and span the range of HyRAM physics models, including tank blowdown, unignited dispersion jet plume, ignited jet flame, and accumulation and overpressure inside an enclosure. Both versions 2.0 and 3.1 of HyRAM are accurate for predictions of blowdowns, diffusion jets, and diffusion flames of hydrogen at pressures up to 900 bar, and HyRAM 3.1 also shows good agreement with cryogenic hydrogen data. Overall, HyRAM 3.1 improves on the accuracy of the physical models relative to HyRAM 2.0. In most cases, this reduces the conservatism in risk calculations using HyRAM.

08 HYDROGEN↗

Reliability model of a monopropellant auxiliary propulsion system

A mathematical model and associated computer code has been developed which computes the reliability of a monopropellant blowdown hydrazine spacecraft auxiliary propulsion system as a function of time. The propulsion system is used to adjust or modify the spacecraft orbit over an extended period of time. The multiple orbit corrections are the multiple objectives which the auxiliary propulsion system is designed to achieve. Thus the reliability model computes the probability of successfully accomplishing each of the desired orbit corrections. To accomplish this, the reliability model interfaces with a computer code that models the performance of a blowdown (unregulated) monopropellant auxiliary propulsion system. The computer code acts as a performance model and as such gives an accurate time history of the system operating parameters. The basic timing and status information is passed on to and utilized by the reliability model which establishes the probability of successfully accomplishing the orbit corrections.

Greenberg, J. S.↗

Design of a mercury Propellant Storage and Distribution assembly

A study has been conducted of a Propellant Storage and Distribution (PSD) assembly for a solar electric propulsion (SEP) thrust subsystem. As a result of the trade-off study an elastomeric diaphragm propellant tank with nitrogen blowdown pressurization was the method selected for propellant expulsion. This study included the following propellant management devices: surface tension, metallic bellows, and metallic and elastomeric diaphragms. Pressurant supply concepts investigated were blowdown, externally pressure regulated, vaporizing Freon 113, and heated CO2/Zeolite. The configuration selected consists of a single propellant tank, a single main propellant latching-solenoid valve, and individual thruster latching-solenoid valves. Stainless steel was the selected tankage material and AF-E-332 was the selected diaphragm material. The PSD design characteristics and interfaces are summarized.

Holcomb, L. B.↗

Prediction of a propellant tank pressure history using state space methods

An analysis of the time response of a propellant supply system operating in the blowdown mode is presented. The supply system is part of a pump-fed propulsion system intended for use on interplanetary spacecraft. As such, the supply system must provide the pump with propellant at sufficient pressure to avoid pump cavitation. The system, consisting of the tank, the liquid propellant, the pressurant gas and propellant vapor mixture, and a film layer separating the liquid and vapor phases, is analyzed using the principles of mass and energy conservation. The resulting set of ordinary, coupled, nonlinear differential equations for the thermodynamic state variables is integrated as an initial value problem. The resulting histories of total pressure, propellant vapor pressure, propellant liquid temperature, film layer temperature, propellant vapor/pressurant gas temperature, propellant vapor mass, and propellant liquid mass enable the calculation of the net positive suction head available at the pump which determines the viability of the pump-fed system concept when operated in the blowdown mode.

Estey, P. N.↗

Effect of Reynolds number variation on aerodynamics of a hydrogen-fueled transport concept at Mach 6

Two separate tests have been made on the same blended wing-body hydrogen-fueled transport model at a Mach number of about 6 and a range of Reynolds number (based on theoretical body length) of 1.577 to 55.36 X 10 to the 6th power. The results of these tests, made in a conventional hypersonic blowdown tunnel and a hypersonic shock tunnel, are presented through a range of angle of attack from -1 to 8 deg, with an extended study at a constant angle of attack of 3 deg. The model boundary layer flow appeared to be predominately turbulent except for the low Reynolds number shock tunnel tests. Model wall temperatures varied considerably; the blowdown tunnel varied from about 255 F to 340 F, whereas the shock tunnel had a constant 70 F model wall temperature. The experimental normal-force coefficients were essentially independent of Reynolds number. A current theoretical computer program was used to study the effect of Reynolds number. Theoretical predictions of normal-force coefficients were good, particularly at anticipated cruise angles of attack, that is 2 to 5 deg. Axial-force coefficients were generally underestimated for the turbulent skin friction conditions, and pitching-moment coefficients could not be predicted reliably.

Penland, Jim A.↗

Numerical Modeling of Pulse Detonation Rocket Engine Gasdynamics And Performance

Pulse detonation rocket engines (PDREs) offer potential performance improvements over conventional designs, but represent a challenging modeling task. A quasi-1-D, finite-rate chemistry computational fluid dynamics model for PDREs is described and implemented. Four different PDRE geometries are evaluated in this work: a baseline detonation tube, a detonation tube with a straight extension, and a detonation tube with two types of converging-diverging (C-D) nozzles. The effect of extension length and C-D nozzle area ratio on the single-shot gasdynamics and performance of a PDRE is studied over a wide range of blowdown pressure ratios (1-1000). The results indicate that a C-D nozzle is generally more effective than a straight extension in improving PDRE performance, particularly at higher pressure ratios. Additionally, the results show that the blowdown process of the C-D nozzle systems could be beneficially cut off well before the pressure at the end-wall reaches the ambient value. The performance results are also compared to a steady-state rocket system using similar modeling assumptions.

Morris, Christopher I.↗