Search NASA⌕ Search

SEARCH · Search NASA

Results for “BME”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

67 records · Page 4

Medical Scenarios Relevant to Spaceflight

The Medical Operational Support Team (MOST) was tasked by the JSC Space Medicine and Life Sciences Directorate (SLSD) to incorporate medical simulation into 1) medical training for astronaut-crew medical officers (CMO) and medical flight control teams and 2) evaluations of procedures and resources required for medical care aboard the International Space Station (ISS). Development of evidence-based medical scenarios that mimic the physiology observed during spaceflight will be needed for the MOST to complete these two tasks. The MOST used a human patient simulator, the ISS-like resources in the Medical Simulation Laboratory (MSL), and evidence from space operations, military operations and medical literature to develop space relevant medical scenarios. These scenarios include conditions concerning airway management, Advanced Cardiac Life Support (ACLS) and mitigating anaphylactic symptoms. The MOST has used these space relevant medical scenarios to develop a preliminary space medical training regimen for NASA flight surgeons, Biomedical Flight Controllers (Biomedical Engineers; BME) and CMO-analogs. This regimen is conducted by the MOST in the MSL. The MOST has the capability to develop evidence-based space-relevant medical scenarios that can help SLSD I) demonstrate the proficiency of medical flight control teams to mitigate space-relevant medical events and 2) validate nextgeneration medical equipment and procedures for space medicine applications.

Bacal, Kira↗

Exploration Medical System Demonstration (EMSD) Project

The Exploration Medical System Demonstration (EMSD) is a project under the Exploration Medical Capability (ExMC) element managed by the Human Research Program (HRP). The vision for the EMSD is to utilize ISS as a test bed to show that several medical technologies needed for an exploration mission and medical informatics tools for managing evidence and decision making can be integrated into a single system and used by the on-orbit crew in an efficient and meaningful manner. Objectives: a) Reduce and even possibly eliminate the time required for on-orbit crew and ground personnel (which include Surgeon, Biomedical Engineer (BME) Flight Controller, and Medical Operations Data Specialist) to access and move medical data from one application to another. b) Demonstrate that the on-orbit crew has the ability to access medical data/information using an intuitive and crew-friendly software solution to assist/aid in the treatment of a medical condition. c) Develop a common data management framework and architecture that can be ubiquitously used to automate repetitive data collection, management, and communications tasks for all crew health and life sciences activities.

Chin, Duane↗

Failure Modes in Capacitors When Tested Under a Time-Varying Stress

Steady step surge testing (SSST) is widely applied to screen out potential power-on failures in solid tantalum capacitors. The test simulates the power supply's on and off characteristics. Power-on failure has been the prevalent failure mechanism for solid tantalum capacitors for decoupling applications. On the other hand, the SSST can also be reviewed as an electrically destructive test under a time-varying stress. It consists of rapidly charging the capacitor with incremental voltage increases, through a low resistance in series, until the capacitor under test is electrically shorted. Highly accelerated life testing (HALT) is usually a time-efficient method for determining the failure mechanism in capacitors; however, a destructive test under a time-varying stress like SSST is even more effective. It normally takes days to complete a HALT test, but it only takes minutes for a time-varying stress test to produce failures. The advantage of incorporating specific time-varying stress into a statistical model is significant in providing an alternative life test method for quickly revealing the failure modes in capacitors. In this paper, a time-varying stress has been incorporated into the Weibull model to characterize the failure modes. The SSST circuit and transient conditions to correctly test the capacitors is discussed. Finally, the SSST was applied for testing polymer aluminum capacitors (PA capacitors), Ta capacitors, and multi-layer ceramic capacitors with both precious metal electrode (PME) and base-metal-electrodes (BME). It appears that testing results are directly associated to the dielectric layer breakdown in PA and Ta capacitors and are independent on the capacitor values, the way the capacitors being built, and the manufactures. The testing results also reveal that ceramic capacitors exhibit breakdown voltages more than 20 times the rated voltage, and the breakdown voltages are inverse proportional to the dielectric layer thickness. The possibility of ceramic capacitors in front-end decoupling applications to block the surge noise from a power supply is also discussed.

Liu, David (Donhang)↗

Three-Dimensional, Porous Anode for Use in Lithium-Ion Batteries and Method of Fabrication Thereof

A three-dimensional, porous anode material suitable for use in a lithium-ion cell. The three-dimensional, porous anode material includes active anode particles embedded within a carbon matrix. The porous structure of this novel anode material allows for the expansion and contraction of the anode without the anode delaminating or breaking apart, thus improving the life-cycle of the lithium-ion cell. An example of this three-dimensional porous anode material is a porous silicon-carbon composite formed using a bi-continuous micro-emulsion (BME) template.

Laicer, Castro↗

Parametric Failures in COTS Capacitors

Insertion of COTS components into hi-rel systems require extensive environmental testing of the parts that often results in parametric failures. Based on experience with commercial and hi-rel PME and BME ceramic capacitors and polymer and MnO2 cathode tantalum capacitors, this presentation discusses two major reasons for parametric failures. One is due to the marketing pressure that forces manufacturers to squeeze performance of COTS components thus leaving insufficient margin between the rated and actual characteristics. Another, and probably a more serious reason is degradation of characteristics caused by physico-chemical processes in materials under environmental stresses. Reliability assessment requires development of models to predict behavior of the parts during applications based on accelerated testing that might be outside the specified conditions and target applications. Examples of models developed to simulate and predict wear-out failures are presented. Risks associated with overstressing during HALT are discussed.

Teverovsky, Alexander↗

A Paradigm Shift in Quality Assurance of COTS Capacitors for Space Applications

Limitations of a traditional approach to screening and qualification of COTS capacitors for space applications that is based on burn-in and life test requirements described in the relevant military specifications are analyzed. An alternative approach that is originated from analysis of highly accelerated life testing (HALT) of capacitors susceptible to wear-out failures and allows for assessments of the risks of failure during the mission is suggested. Examples include results of reliability testing of advanced BME ceramic capacitors, polymer tantalum capacitors and multianode manganese oxide tantalum capacitors.

Alexander A Teverovsky↗

Extending quantum-mechanical benchmark accuracy to biological ligand-pocket interactions

Predicting the binding affinity of ligands to protein pockets is key in the drug design pipeline. The flexibility of ligand-pocket motifs arises from a range of attractive and repulsive electronic interactions during binding. Accurately accounting for all interactions requires robust quantum-mechanical (QM) benchmarks, which are scarce for ligand-pocket systems. Additionally, disagreement between “gold standard” Coupled Cluster (CC) and Quantum Monte Carlo (QMC) methods casts doubt on many benchmarks for larger non-covalent systems. We introduce the “QUantum Interacting Dimer” (QUID) benchmark framework containing 170 non-covalent (non-)equilibrium systems modeling chemically and structurally diverse ligand-pocket motifs. Symmetry-adapted perturbation theory shows that QUID broadly covers non-covalent binding motifs and energetic contributions. Robust binding energies are obtained using complementary CC and QMC methods, achieving agreement of 0.5 kcal/mol. The benchmark data analysis reveals that several dispersion-inclusive density functional approximations provide accurate energy predictions, though their atomic van der Waals forces differ in magnitude and orientation. Contrarily, semiempirical methods and empirical force fields require improvements in capturing non-covalent interactions (NCIs) for out-of-equilibrium geometries. The wide span of NCIs, highly accurate interaction energies, and analysis of molecular properties take QUID beyond the “gold standard” for QM benchmarks of ligand-protein systems.

Puleva, Mirela [University of Luxembourg, Luxembou↗

Combined hydrogen and lithium beam emission spectroscopy observation system for Korea Superconducting Tokamak Advanced Research

A novel beam emission spectroscopy observation system was designed, built, and installed onto the Korea Superconducting Tokamak Advanced Research tokamak. The system is designed in a way to be capable of measuring beam emission either from a heating deuterium or from a diagnostic lithium beam. The two beams have somewhat complementary capabilities: edge density profile and turbulence measurement with the lithium beam and two dimensional turbulence measurement with the heating beam. Two detectors can be used in parallel: a CMOS camera provides overview of the scene and lithium beam light intensity distribution at maximum few hundred Hz frame rate, while a 4 × 16 pixel avalanche photo-diode (APD) camera gives 500 kHz bandwidth data from a 4 cm × 16 cm region. The optics use direct imaging through lenses and mirrors from the observation window to the detectors, thus avoid the use of costly and inflexible fiber guides. Remotely controlled mechanisms allow adjustment of the APD camera’s measurement location on a shot-to-shot basis, while temperature stabilized filter holders provide selection of either the Doppler shifted deuterium alpha or lithium resonance line. The capabilities of the system are illustrated by measurements of basic plasma turbulence properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Preconditioning and Soldering on Failures of Chip Tantalum Capacitors

Soldering of molded case tantalum capacitors can result in damage to Ta205 dielectric and first turn-on failures due to thermo-mechanical stresses caused by CTE mismatch between materials used in the capacitors. It is also known that presence of moisture might cause damage to plastic cases due to the pop-corning effect. However, there are only scarce literature data on the effect of moisture content on the probability of post-soldering electrical failures. In this work, that is based on a case history, different groups of similar types of CWR tantalum capacitors from two lots were prepared for soldering by bake, moisture saturation, and longterm storage at room conditions. Results of the testing showed that both factors: initial quality of the lot, and preconditioning affect the probability of failures. Baking before soldering was shown to be effective to prevent failures even in lots susceptible to pop-corning damage. Mechanism of failures is discussed and recommendations for pre-soldering bake are suggested based on analysis of moisture characteristics of materials used in the capacitors' design.

multilayer ceramic capacitor (MLCC)↗

Cracking Failures in MLCCs and Military Specifications

Failures of MLCCs during applications might indicate problems with the screening and qualification system used. Several cracking related failures of military-grade MLCCs that have been observed over the last few years require analysis of the efficiency and completeness of the procedures used in military specifications. This presentation discusses deficiencies of the currently used procedures to reveal and prevent cracking failures in space projects and possible ways of their improvements.

reliability↗