Search NASA⌕ Search

SEARCH · Search NASA

Results for “BUFFER STORAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A High Temperature Gas Reactor Integrated Energy System Using Energy Storage as a Buffer for Hydrogen Production

Analysis of an integrated energy system producing hydrogen in a high temperature steam electrolysis system via steam provided by a sensible heat thermal energy storage system charged by a high temperature gas reactor. Preliminary results over a continuous discharge cycle and single charging cycle shows minimal reactor impact despite 25% electrical power load change. Hydrogen production is held constant with steam provided by the thermal energy storage system.

08 HYDROGEN↗

Spaceborne optical disk controller development

The current status and potential applications of an optical-disk buffer (ODB) memory system being developed by an interagency consortium including NASA and the USAF are reviewed. The design goals for the ODB include usable capacity 1 Tb, maximum data rate 1.6 Gb/s, read error rate less than 10 to the -12th, time to initial access less than 100 ms, and unlimited read/write cycles. Present efforts focus on a brassboard ODB which employs 12 14-inch magnetooptic disks and 24 nine-diode read/write heads. A typical space application of an optical disk mass memory system (ODMMS) is discussed: as communications buffer, temporary storage, and/or multiuser I/O buffer for data management on the Space Station Earth Observing System. Environmental, operational, system-architecture, and functional-separation factors; critical design issues; and standardization questions for spaceborne ODMMSs are examined in detail.

Shull, Thomas A.↗

Optimizing checkpoint data placement with guaranteed burst buffer endurance in large-scale hierarchical storage systems

Non-volatile devices, such as SSDs, will be an integral part of the deepening storage hierarchy on large-scale HPC systems. These devices can be on the compute nodes as part of a distributed burst buffer service or they can be external. Wherever they are located in the hierarchy, one critical design issue is the SSD endurance under the write-heavy workloads, such as the checkpoint I/O for scientific applications. For these environments, it is widely assumed that checkpoint operations can occur once every 60 min and for each checkpoint step as much as half of the system memory can be written out. Unfortunately, for large-scale HPC applications, the burst buffer SSDs can be worn out much more quickly given the extensive amount of data written at every checkpoint step. One possible solution is to control the amount of data written by reducing the checkpoint frequency. However, a direct effect caused by reduced checkpoint frequency is the increased vulnerability window of system failures and therefore potentially wasted computation time, especially for large-scale compute jobs.

Computer Science↗

BBOS: Efficient HPC Storage Management via Burst Buffer Over-Subscription

To avoid access to PFS, dedicated BB allocation is preferred despite of severe BB underutilization. Recently, new all-flash HPC storage systems with integrated BB and PFS are proposed, which speed up access to PFS. For this reason, we adopt BB over-subscription allocation method by allowing HPC applications to use BB only for I/O phase for improving BB utilization. Unfortunately, BB over-subscription aggravates I/O interference and demotion overhead from BB to PFS, resulting in degraded performance. To minimize the performance degradation, we develop an I/O scheduler to prevent I/O congestion and a new transparent data management system based on checkpoint/restart characteristics of HPC applications. With the proposed approach, not only the BB utilization can be improved, but also high performance of applications is achieved. In our experiments, we find that BB utilization is improved at least 2.2x, and more stable and higher checkpoint performance is guaranteed compared to other approaches. Besides, we achieve up to 96.4% hit ratio of restart requests on BB and up to 3.1x higher restart performance than others.

Sung, H↗

Thermal Stress Modeling and Analysis of Packed-bed Thermocline Energy Storage Tank for INL Thermal Energy Distribution System (TEDS)

The Thermal Energy Distribution System (TEDS) at Idaho National Laboratory (INL) is a thermal-hydraulic flow loop to support the integration of co-located multiple experimental systems, where a packed-bed thermal energy storage (TES) is installed as a thermal buffer and storage unit for TEDS. The packed-bed TES is adopted in TEDS because of its benefit as a low-cost single-tank storage option compared to the traditional two-tank storage. However, thermal ratcheting is one potential design concern which is caused by the rearrangement of granular filler inside a packed-bed tank during continuous thermal cycling operation of the packed-bed TES tank. If the thermally induced stress exceeds yield strength of the tank wall, it may cause catastrophic consequences like rupture of the thermal storage tank. Thus, it is crucial to understand the phenomenon to ensure the robust operation. Based on the temperature boundary conditions given by transient thermal analyses with computational fluid dynamics (CFD) simulations, the thermal ratcheting analysis is then conducted to evaluate the hoop stress and resultant thermal ratcheting potential of the TES tanks with two different modeling approaches: (1) infinite rigidity model and (2) Drucker-Prager (DP) model. The validity of each modeling method was examined by comparing the numerical simulation with the experimental data obtained from the packed-bed TES tank for Solar One Plant and evaluate the thermal ratcheting potential of the TEDS TES tank.

25 ENERGY STORAGE↗

Thermal Modeling and Simulation of the Packed-bed Thermal Energy Storage Combined with INL Thermal Energy Distribution System

Dynamic Energy Transport and Integration Lab (DETAIL) at Idaho National Laboratory is to support experimental demonstration and validation research on Nuclear-Renewable Hybrid Energy System [1]. The Thermal Energy Distribution System (TEDS) is a thermal-hydraulic flow loop in DETAIL with its own dedicated control system to support the integration of co-located multiple experimental systems, where a packed-bed thermal energy storage (TES) is installed as a thermal buffer and storage unit. Among various TES options, the packed-bed TES is adopted in TEDS because it offers a low-cost single-tank thermal storage option compared to the traditional two-tank TES. However, since the TES tank is filled with granular fillers having different thermophysical properties from those of TES tank wall, there is a potential thermo-mechanical issue to be carefully addressed like thermal ratcheting which may pose a significant design concern for the packed-bed TES tank. Thermal ratcheting is a thermomechanical process caused by the repeated rearrangement of granular filler inside a TES tank during continuous thermal cycling operation of the packed-bed TES system. If the thermally induced stress exceeds the yield strength of a TES tank wall, catastrophic consequences may happen like rupture of the TES tank. Thus, it is important to understand the phenomenon to ensure the robust operation of the packed-bed TES tank. Given that thermal ratcheting is caused by complex interaction of thermal transport in the porous bed and solid mechanics, the accurate prediction of transient thermal behavior of the packed-bed TES tank, which is the focus of this paper, is critical to the reliable thermal ratcheting analysis. This paper discusses the numerical modeling, simulation, and validation studies that are ongoing at INL to investigate the transient thermal behavior of the packed-bed TES. Of particular concern is the transient thermal process occurring in the packed-bed TES unit that is operated in conjunction with the INL TEDS. The main goal of this research is three-fold: (i) provide preliminary insights into the transient thermal behavior of the TEDS TES tank, (ii) support the thermal measurement and validation plan for TEDS experiment, and (iii) provide transient thermal boundary conditions to support the reliable thermal ratcheting analysis of the TEDS TES tank. For the transient thermal modeling and analysis, a CFD model was developed, and the validity of the modeling approach was examined via comparing the numerical simulation results with the experimental data obtained from various design characteristics of packed-bed TES tanks. Then, the present modeling method was applied for the transient thermal analysis of the TEDS TES tank, and the results are discussed along with the potential improvement of data acquisition strategy for the future TEDS experiments for more precise validation study.

25 ENERGY STORAGE↗

Improved Stability of a Model IgG3 by DoE-Based Evaluation of Buffer Formulations

Formulating appropriate storage conditions for biopharmaceutical proteins is essential for ensuring their stability and thereby their purity, potency, and safety over their shelf-life. Using a model murine IgG3 produced in a bioreactor system, multiple formulation compositions were systematically explored in a DoE design to optimize the stability of a challenging antibody formulation worst case. The stability of the antibody in each buffer formulation was assessed by UV/VIS absorbance at 280 nm and 410 nm and size exclusion high performance liquid chromatography (SEC) to determine overall solubility, opalescence, and aggregate formation, respectively. Upon preliminary testing, acetate was eliminated as a potential storage buffer due to significant visible precipitate formation. An additional 2 4 full factorial DoE was performed that combined the stabilizing effect of arginine with the buffering capacity of histidine. From this final DoE, an optimized formulation of 200 mM arginine, 50 mM histidine, and 100 mM NaCl at a pH of 6.5 was identified to substantially improve stability under long-term storage conditions and after multiple freeze/thaw cycles. Therefore, our data highlights the power of DoE based formulation screening approaches even for challenging monoclonal antibody molecules.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a High-Rate Front-End ASIC for X-Ray Spectroscopy and Diffraction Applications

We developed a new front-end application-specific integrated circuit (ASIC) to upgrade the Maia X-ray microprobe. The ASIC instruments 32 configurable channels that perform either positive or negative charge amplification, pulse shaping, peak amplitude, and time extraction along with buffered analog storage. At a gain of 3.6 V/fC, 1-μs peaking time, and a temperature of 248 K, an electronic resolution of 13 and 10 e- rms was measured with and without a silicon drift detector (SDD) sensor, respectively. A spectral resolution of 170-eV full-width at half-maximum (FWHM) at 5.9 keV was obtained with an 55Fe source. The channel linearity was better than ± 1% with rate capabilities up to 40 kcps. The ASIC was fabricated in a commercial 250-nm process with a footprint of 6.3 mm × 3.9 mm and dissipates 167 mW of static power.

Vernon, Emerson↗

Thermal buffering of receivers for parabolic dish solar thermal power plants

A parabolic dish solar thermal power plant comprises a field of parabolic dish power modules where each module is composed of a two-axis tracking parabolic dish concentrator which reflects sunlight (insolation) into the aperture of a cavity receiver at the focal point of the dish. The heat generated by the solar flux entering the receiver is removed by a heat transfer fluid. In the dish power module, this heat is used to drive a small heat engine/generator assembly which is directly connected to the cavity receiver at the focal point. A computer analysis is performed to assess the thermal buffering characteristics of receivers containing sensible and latent heat thermal energy storage. Parametric variations of the thermal inertia of the integrated receiver-buffer storage systems coupled with different fluid flow rate control strategies are carried out to delineate the effect of buffer storage, the transient response of the receiver-storage systems and corresponding fluid outlet temperature. It is concluded that addition of phase change buffer storage will substantially improve system operational characteristics during periods of rapidly fluctuating insolation due to cloud passage.

Manvi, R.↗

TelemeTrak Final Technical Report – Award DE-SC0022722

We developed a browser-based simulation tool to evaluate whether buffering can be advantageous in various climate zones. This tool leverages the Amazon cloud services to process hundreds of simulations in a parametric sweep. This tool, still under development, will ultimately be usable by installers to determine exactly how much storage of what type to include.

25 ENERGY STORAGE↗

Phase transition and energy storage behavior of antiferroelectric PLZT thin films epitaxially deposited on SRO buffered STO single crystal substrates [Phase transition and energy storage behavior of antiferroelectric PLZT thin films epitaxially deposited on SRO buffered STO single crystal substrates]

Thin films of 300-nm-thick (Pb 0.98 , La 0.02 )(Zr 0.95 , Ti 0.05 )O 3 (PLZT) were epitaxially deposited on (100), (110), and (111) SrTiO3 single crystal substrates by pulsed laser deposition. X-ray diffraction line and reciprocal space mapping (RSM) scans were used to determine the crystal structure. Tetragonal ((001) PLZT) and monoclinic MA ((O 1 1 ) and (111) PLZT) structures were found, which influenced the stored energy density. Electric field induced antiferroelectric to ferroelectric (AFE—>FE) phase transitions were found to have a large reversible energy density of up to 30J/cm 3 . With increasing temperature, an AFE to relaxor ferroelectric (AFE—>RFE) transition was found. The RFE phase exhibited lower energy loss, and an improved energy storage efficiency. Here, the results are discussed from the perspective of crystal structure, dielectric phase transitions, and energy storage characteristics.

25 ENERGY STORAGE↗

Automotive storage of hydrogen in alane.

Although alane (AlH{sub 3}) has many interesting properties as a hydrogen storage material, it cannot be regenerated on-board a vehicle. One way of overcoming this limitation is to formulate an alane slurry that can be easily loaded into a fuel tank and removed for off-board regeneration. In this paper, we analyze the performance of an on-board hydrogen storage system that uses alane slurry as the hydrogen carrier. A model for the on-board storage system was developed to analyze the AlH{sub 3} decomposition kinetics, heat transfer requirements, stability, startup energy and time, H{sub 2} buffer requirements, storage efficiency, and hydrogen storage capacities. The results from the model indicate that reactor temperatures higher than 200 C are needed to decompose alane at reasonable liquid hourly space velocities, i.e., > 60 h{sup -1}. At the system level, a gravimetric capacity of 4.2 wt% usable hydrogen and a volumetric capacity of 50 g H{sub 2}/L may be achievable with a 70% solids slurry. Under optimum conditions, {approx}80% of the H{sub 2} stored in the slurry may be available for the fuel cell engine. The model indicates that H{sub 2} loss is limited by the decomposition kinetics rather than by the rate of heat transfer from the ambient to the slurry tank.

08 HYDROGEN↗

Evapotranspiration depletes groundwater under warming over the contiguous United States

A warmer climate increases evaporative demand. However, response to warming depends on water availability. Existing earth system models represent soil moisture but simplify groundwater connections, a primary control on soil moisture. Here we apply an integrated surface-groundwater hydrologic model to evaluate the sensitivity of shallow groundwater to warming across the majority of the US. We show that as warming shifts the balance between water supply and demand, shallow groundwater storage can buffer plant water stress; but only where shallow groundwater connections are present, and not indefinitely. As warming persists, storage can be depleted and connections lost. Similarly, in the arid western US warming does not result in significant groundwater changes because this area is already largely water limited. The direct response of shallow groundwater storage to warming demonstrates the strong and early effect that low to moderate warming may have on groundwater storage and evapotranspiration.

54 ENVIRONMENTAL SCIENCES↗

Distribution Storage Networks (Draft Version 0.3)

Distribution storage networks are interconnected distribution-level bulk energy storage devices that function as core infrastructure elements to provide both grid resilience and defense against IoT-based cyber grid security threats. The recognition that these are core grid functions changes how storage of this type valued, financed, and operated as compared to storage for ancillary grid services. Distribution storage networks make use of fast bilateral storage to buffer the grid from edge device-based volatilities; this is the essence of both its resilience capability and its cyber defense capability. These storage networks must be core grid components because resilience is an intrinsic grid characteristic and both it and cyber defense of the distribution grid are the responsibility of the distribution utility.

97 MATHEMATICS AND COMPUTING↗

Characterizing Hydrogen Storage Potential in U.S. Underground Gas Storage Facilities

Abstract Underground hydrogen storage is a long‐duration energy storage option for a low‐carbon economy. Although research into the technical feasibility of underground hydrogen storage is ongoing, existing underground gas storage (UGS) facilities are appealing candidates for the technology because of their ability to store and deliver natural gas. We estimate that UGS facilities in the United States (U.S.) can store 327 TWh (9.8 MMT) of pure hydrogen. A complete transition to hydrogen storage would reduce the collective working‐gas energy of UGS facilities by ∼75%; however, most (73.2%) UGS facilities could maintain current energy demand using a 20% hydrogen‐natural gas blend. U.S. UGS facilities can buffer 23.9%–44.6% of the high and low hydrogen demand projected for 2050, respectively, which exceeds the current percentage of natural gas demand buffered by storage. Thus, transitioning UGS infrastructure to hydrogen could substantially reduce the number of new hydrogen storage facilities needed to support a hydrogen economy.

08 HYDROGEN↗

Design-Point Techno-Economics of Brayton Cycle PTES for Combined Heat and Power

Pumped thermal energy storage (PTES) systems are grid batteries that use heat pumps to create both hot and cold thermal energy stores when there is excess electricity and then use a power cycle to convert the thermal energy into electricity when there is demand for electricity. In normal operation, Joule–Brayton PTES discharges low-grade heat at temperatures useful for thermal energy consumers like district and industrial heating. Furthermore, PTES designs, like conventional combined heat and power (CHP) technology, can be modified to sacrifice some round-trip efficiency (RTE) to increase the temperature of heat rejection. Here, this paper uses design-point performance and cost models that provide a detailed understanding of the efficiency and cost tradeoffs of rejecting heat at various temperatures in ideal-gas Brayton PTES configurations. First, we keep the heat rejection in its nominal location in the PTES system: in the discharge cycle after the low-pressure exit of the recuperator before the cold-storage heat exchanger. Next, we move the heat rejection to the discharge turbine exit. We define design-point metrics that isolate both the cost and performance penalty associated with the hotter heat rejection and attribute it exclusively to the heat economic metrics. Finally, we estimate the performance of electric heater technology to generate heat at equivalent temperatures. We find that the levelized cost of heat (LCOH), including the cost of thermal energy storage (TES) buffering the PTES and heat off-taker, compares favorably versus electric technologies and is less than the cost of natural gas for low temperature scenarios and competitive with the cost of natural gas in some regions of the contiguous U.S. in high temperature scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrifying Airport GSE: Monte Carlo Grid Impacts

Airports globally are shifting from ICE-powered to electric Ground Support Equipment (eGSE) to enhance efficiency, reduce operational costs, and improve operator health. Leveraging predictable routes, flat terrain, and low operational speeds, airports provide ideal conditions for electrification. This study evaluates freight GSE electrification at Dallas-Fort Worth International Airport (DFW), USA, using the Agile@ platform, which integrates three analytical methods: Freight Facility Model (FFM), Activity-Structure-Intensity-Fuel (ASIF), and Monte Carlo simulations. Results from 10,000 simulations indicate modest but critical increases in electricity demand and significant variability in GSE energy consumption. These insights emphasize the importance of data-driven scheduling, targeted maintenance, and strategic infrastructure planning. For high-uncertainty scenarios, airports are advised to deploy buffer energy storage systems (battery banks), implement demand-response charging strategies, schedule flexible workforce shifts, and prioritize proactive maintenance-particularly for equipment with higher operational uncertainty, such as tug tractors with trailers. Agile@ thus offers a robust, scalable, and data-driven framework to optimize long-term GSE planning and enhance reliability across diverse airport environments.

Bose, Ranjan [ORNL] (ORCID:0009000791026327)↗

Design-Point Techno-Economics of Brayton Cycle PTES for Combined Heat and Power

Pumped thermal energy storage (PTES) systems are grid batteries that use heat pumps to create both hot and cold thermal energy stores when there is excess electricity and then use a power cycle to convert the thermal energy into electricity when there is demand for electricity. In normal operation, Joule-Brayton PTES discharges low-grade heat at temperatures useful for thermal energy consumers like district and industrial heating. Furthermore, PTES designs, like conventional combined heat and power (CHP) technology, can be modified to sacrifice some round-trip efficiency RTE to increase the temperature of heat rejection. This paper uses design-point performance and cost models that provide a detailed understanding of the efficiency and cost trade-offs of rejecting heat at various temperatures in ideal-gas Brayton PTES configurations. First, we keep the heat rejection in its nominal location in the PTES system: in the discharge cycle after the low-pressure exit of the recuperator before the cold-storage heat exchanger. Next, we move the heat rejection to the discharge turbine exit. We define design-point metrics that isolate both the cost and performance penalty associated with the hotter heat rejection and attribute it exclusively to the heat economic metrics. Finally, we estimate the performance of electric heater technology to generate heat at equivalent temperatures. We find that the levelized cost of heat, including the cost of thermal energy storage (TES) buffering the PTES and heat off-taker, compares favorable versus electric technologies and is less than the cost of natural gas for low temperature scenarios and competitive with the cost of natural gas in some regions of the contiguous United States in high temperature scenarios.

CHP↗