Search NASA⌕ Search

SEARCH · Search NASA

Results for “Backup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Consumer Benefits of Clean Energy: The resilience value of residential solar + storage systems in the continental U.S.

Meeting national and state decarbonization goals requires a transition to clean energy technologies. Energy efficiency, demand flexibility, renewable energy and storage can reduce consumers’ electricity bills, lower total electricity system costs, and provide health and resilience benefits. Berkeley Lab developed a series of briefs that explore these consumer benefits of a clean energy transition. Clean energy resources that are located behind the meter have the potential to benefit the hosting customers by providing affordability, environmental, and reliability and resilience value. Solar plus storage systems (PVESS) are clean energy resources that can supply backup power without requiring fuel resupply or increasing local emissions. This report examines the regional value of PVESS for resilience by calculating a benefit-cost ratio (BCR) that considers the annual resiliency benefits of PVESS and the annualized cost of the investment. In addition, we estimate the expected technical mitigation potential of PVESS systems at the county-level to these expected events, and characterize the customer interruption costs by determining the value of lost load at the state level.

14 SOLAR ENERGY↗

Creating a Salt Batch: Challenges and Lessons Learned

CONCLUSION • The overall Salt Batch system has been honed through each iteration of the process • Increased communication across facilities and work groups has enabled the salt team to react swiftly to emergent items and identify improvement opportunities • Even the best plans require backup options – Emergent items can appear at any time during the process – Flexibility to adapt to the unexpected is a must-have team mindset • To date, every salt batch compiled has been qualified and approved as feed for SWPF – No feed break has occurred between the Tank Farm and SWPF

Goldblatt, Joshua B. [Savannah River National Labo↗

Low Yield Nuclear Monitoring Physics Experiment 1 – Integrated Data Acquisition System Design and Initial Observations

The report documents the design of the Integrated Data AcQuisition (IDAQ) system and observations recorded during the first in a series of underground chemical explosions conducted on the Nevada National Security Site (NNSS) in southern Nevada. Experiments are funded as part of Low Yield Nuclear Monitoring (LYNM) research and development within the United States National Nuclear Security Administration NA-22 nuclear non-proliferation program. The series is part of the broader Physical Experiment 1 (PE1) being conducted in and around the P-tunnel facility on the NNSS. Each explosive experiment utilizes several tons of comp-B to generate signals recorded by a broad suite of instrumentation. The IDAQ serves as the backbone for all subsurface instrumentation providing precise time synchronization, remote control, data exfiltration and backup, along with recording several sensing modalities throughout the underground complex that includes ground motion, environmental conditions, and electromagnetic signals.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Precision Time Protocol Performance Testing Over Optical Transport Network

The US Department of Energy Office of Electricity has partnered with Oak Ridge National Laboratory (ORNL) to find alternative precision timing solutions for the nation’s power grid. This effort is in response to the vulnerabilities identified in the Global Navigation Satellite System (GNSS), of which the US Global Positioning System (GPS) platform is a part. Additionally, Executive Order 139055 has highlighted the need for alternative or backup timing solutions. ORNL has established a Timing Lab and has been testing various technologies and timing devices as part of this effort. Precision Time Protocol (PTP), and the off-the-shelf timing devices and network connections that support it, are among the alternatives being tested. This work reports the accuracy of PTP over an Optical Transport Network (OTN) and is part of a series published by the Center for Alternative Synchronization and Timing (CAST).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybrid Powered Command Trailers Cost-Benefit Analysis Tool: User Guide and Examples

U.S. Forest Service (USFS) wildfire base camps use portable power for electrical needs, including yurts and trailers from which logistics staff work during the incident. These yurts and trailers are conventionally powered by portable diesel generators. Hybrid portable power systems consisting of a combination of solar photovoltaics (PV), battery energy storage systems (BESS), and/or backup diesel generators have been used in recent years and were piloted by the National Technology and Development Program (NTDP) on incidents in fall 2024 as part of NTDP's Portable Power Project. As part of that project, this work included the development of two Excel-based tools and two reports explaining the tools. The first tool, the Incident Energy Systems Model, is an Excel-based tool that models the power output of hybrid portable power systems powering yurts and/or trailers at fire camps over a typical day. The associated report (published separately) outlines a user guide for the model and walks through two scenarios. The two scenarios are 1) trailers powered by rooftop solar PV, batteries, and a back-up diesel generator, and 2) trailers powered by ground mount solar PV, batteries, and a back-up diesel generator. The second tool is a high-level cost-benefit analysis of the same two types of portable power systems, and is location independent.

14 SOLAR ENERGY↗

Incident Energy Systems Model: User Guide and Examples

U.S. Forest Service (USFS) wildfire base camps use portable power for electrical needs, including yurts and trailers from which logistics staff work during the incident. These yurts and trailers are conventionally powered by portable diesel generators. Hybrid portable power systems consisting of a combination of solar photovoltaics (PV), battery energy storage systems (BESS), and/or backup diesel generators have been used in recent years and were piloted by the National Technology and Development Program (NTDP) on incidents in fall 2024 as part of NTDP's Portable Power Project. As part of that project, this work included the development of two Excel-based tools and two reports explaining the tools. The first tool, the Incident Energy Systems Model, is an Excel-based tool that models the power output of hybrid portable power systems powering yurts and/or trailers at fire camps over a typical day.

14 SOLAR ENERGY↗

Hydrogen Transportation and Distributed Energy Systems Seismic Risk Assessment for Cascadia Subduction Zone Airport Facilities

Portland International Airport in Oregon is exploring operating a fleet of 28 fuel cell electric buses to support airport operations and possibly provide backup power during outages. In this report, we evaluate the risk of hydrogen deployment at an airport considering the potential for seismic activity. We present a seismic risk assessment for pressurized piping for a generic hydrogen refueling station at the airport. Only pressurized piping was considered in the risk analysis because of its vulnerability and availability of fragility information unlike the other components. Seismic capacity of other components should be included as more information becomes available.

08 HYDROGEN↗

​​Hydrogen Transportation and Distributed Energy Systems Seismic Risk Assessment for Cascadia Subduction Zone Airport Facilities​

Portland International Airport in Oregon is exploring operating a fleet of 28 fuel cell electric buses to support airport operations and possibly provide backup power during outages. In this report, we evaluate the risk of hydrogen deployment at an airport considering the potential for seismic activity. We present a seismic risk assessment for pressurized piping for a generic hydrogen refueling station at the airport. Only pressurized piping was considered in the risk analysis because of its vulnerability and availability of fragility information unlike the other components. Seismic capacity of other components should be included as more information becomes available. To characterize the seismic hazard, we considered the initiating event frequency of a Cascadia Subduction Zone earthquake event based on data from the literature. Seismic stressors that translate to the site from an earthquake event are expressed as peak ground acceleration. Site disturbance is characterized as a function of soil conditions, represented by different shear wave velocity values, which affect how seismic waves propagate and impact structures. Pipe fragility curves as a function of seismic capacity were used to correlate ground acceleration and failure probability. These fragility characteristics were combined with site-specific soil conditions to calculate the probability of pipe rupture during a seismic event. It should be noted that multiple simultaneous failures due to an earthquake event as a common cause are not considered. Some epistemic uncertainties such as self-exciting shocks, aftershocks, and the time variant nature of the ground motion are not considered either.

08 HYDROGEN↗

Cost Benefit Analysis of Solar PV for the City of Oldsmar, FL

The City of Oldsmar is in the early stages of exploring renewable energy opportunities as a part of their initiative to reduce energy costs, improve backup power capacity, and begin the transition to more sustainable operations. The city is particularly interested in deploying a floating or ground-mounted solar PV system at its wastewater treatment plant. Currently, there are no solar PV installations in Oldsmar and there has been hesitancy to implement such a project due to the possible capital costs and limited technical capacity. Despite this the initiative has gained internal buy-in among staff working for the city. To assist with gaining more buy-in and making future decisions the city sought technical assistance (TA) from the Energy to Communities (E2C) Expert Match Program. Through the Expert Match Program, the city received TA provided by the Pacific Northwest National Lab (PNNL) to evaluate the cost effectiveness of several solar options. This report details the analysis and results of the work performed for TA.

14 SOLAR ENERGY↗

Next-Generation Energy Technologies for Connected and Automated On-Road Vehicles (NEXTCAR) - Predictive Data-Driven Vehicle Dynamics and Powertrain Control: from ECU to the Cloud (Final Scientific/Technical Report)

This project developed and demonstrated a predictive, data-driven vehicle control system designed to improve energy efficiency and driving performance. The team created intelligent self-driving car technology that optimizes fuel and electricity use by proactively planning vehicle actions. By combining Level 4 autonomous driving capabilities with vehicle-to-everything (V2X) connectivity, the system enables vehicles to adjust speed and change lanes in response to traffic signals, surrounding vehicles, and road conditions, reducing unnecessary stops and delays. In testing, the system improved vehicle fuel economy by more than 30% and reduced travel time by approximately 10%, compared to a conventional adaptive cruise control baseline. These results demonstrate the technical effectiveness of using predictive, V2X-enabled strategies, such as traffic light timing and surrounding traffic awareness, to inform real-time vehicle powertrain control and driving behavior. Additionally, a supporting cloud platform was developed to provide dispatch and route recommendations as well as to log vehicle data, demonstrating the economic feasibility of this approach at the fleet level. By optimizing dispatching and routing operations, this technology enables electric fleet operators to use their vehicles more efficiently and reduce reliance on diesel backups, lowering both operating costs and energy consumption. Overall, this project’s technology advances the future of clean, energy-efficient transportation, enabling vehicles and fleets to reduce energy waste, cut costs, and lower emissions through intelligent automation and connectivity.

33 ADVANCED PROPULSION SYSTEMS↗

Project Planning for Community Resilience: Aquinnah and Chilmark, Massachusetts

This report presents the findings of an energy system planning study for the towns of Aquinnah and Chilmark, MA, on the island of Martha’s Vineyard, conducted under the U.S. Department of Energy ETIPP program. The study used the DER-CAM model to optimize the deployment of PV and battery microgrids to enhance energy resilience against power outages, particularly winter storms. Key findings show that PV is highly cost-effective and delivers net annual savings. However, due to limited rooftop space and low winter solar output, PV and battery storage alone cannot support the full critical load during outages. Solutions incorporating conventional backup generators were found to be more economically viable for achieving 100% critical load support.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Preliminary Analysis of Nuclear-Powered Data Center Scenarios

This report provides a comprehensive analysis of the potential for nuclear energy to meet the growing energy demands of data centers (DCs). It evaluates the technical, economic, and socio-environmental implications of coupling Nuclear Power Plants (NPPs) with DCs, providing initial responses to several key research questions: What is the potential increased energy demand from DCs in the U.S., in the short, medium and long term? The U.S. is experiencing a rapid increase in energy demand from DCs, with projections indicating a total increase of 24-74 GWy(e) by 2028. Meeting this demand with nuclear energy would require 27–85 GWe of installed capacity. While this surge is expected to slow in the long term, the DC industry needs reliable, scalable, and clean energy sources. How much nuclear capacity can be deployed to meet DC demand and in which timeframe? Several pathways for increasing nuclear capacity were identified, including uprates, restarts of recently retired reactors, power purchase agreements with existing fleet, and new construction. Approximately 20‒28 GWe of nuclear capacity could be dedicated to DCs by the early 2030s. How much High Assay Low Enriched Uranium (HALEU) would be needed to support some nuclear deployment scenarios for DCs? Meeting the deployment targets announced by Google and Amazon for the Kairos Power Fluoride-Salt-Cooled High-Temperature Reactor or KP-FHR (~500 MWe by 2035) and the Xe-100 (~1 GWe by 2040), respectively, requires ramping up 19.75% enriched HALEU production to ~6 t/yr by 2040. What types of nuclear energy/DC coupling options exist, and what are the different benefits/challenges? Five coupling options were analyzed, ranging from grid-connected configurations to colocated, behind-the-meter setups. Key design considerations include the proximity to high- and/or medium-voltage transmission lines, the desired internal fault tolerance, and the sources of alternative/backup power during outages. Each coupling option offers unique benefits and challenges in terms of reliability, system costs, regulation, timeline, etc. A list of NPP/DC deployment scenarios was developed, considering existing or newly built NPP or DC projects. Colocated DCs with new small modular reactors or large reactors on greenfield and brownfield sites are the focus of this report. What types of reactors, especially what size, may be incentivized by DCs? Reactor sizing optimization revealed that the ideal reactor size and number of units depend on DC demand, coupling configurations defined in this report, and other economic factors. Larger reactors are preferred for high-demand DCs and grid-connected systems, while larger number of smaller reactors are better suited for DC configurations without grid backup. Which sites may be compatible with co-located nuclear-powered DCs? Siting those projects is a complicated evaluation factoring local water resources, grid connection availability and reliability, IT infrastructure, local work force, proximity to population zones, etc. For this effort greenfield and brownfield sites such as retired coal-fired plants were used to evaluate this question. This evaluation is not meant to recommend any particular site but it highlights key siting criteria and demonstrates large-scale site availability. What are the socio-economic impacts of co-located nuclear-powered DCs? Those projects generate substantial economic benefits to the local economy, particularly in urban settings. Hyperscale DCs colocated with nuclear power plants (sized around 1 GW of power) can create nearly 1,700 jobs for annual operations and more than 7,300 jobs among the supply chain and local businesses as a result of increased household spending. Rural projects also provide significant benefits, but at lower magnitudes compared to urban deployments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Typical Use Cases for Energy Storage in Rural Areas

Public power utilities and cooperatives play a crucial role in delivering reliable and affordable electricity to remote and sparsely populated regions. Unlike their urban counterparts, these utilities often face a unique set of challenges that can complicate their operations and service delivery. One of the primary challenges is the vast geographical area they must cover, which often results in higher transmission and distribution costs per customer. Additionally, public power utilities in rural areas often cannot afford the investments required to maintain and upgrade aging grid infrastructure to provide reliable and resilient power or withstand the impacts of recurring, severe weather events, which can cause extended outages and disrupt service delivery. Energy storage has emerged as a promising tool to help public power utilities meet these challenges. By enabling the storage of excess energy during low demand periods and providing a source of backup electricity during outages, energy storage systems can help utilities balance supply and demand more effectively. Additionally, they can help integrate a portfolio of various energy sources, reduce the need for expensive peak power purchases and provide ancillary services that stabilize the grid. This white paper describes potential use cases for energy storage in rural areas as well as documents a set of relevant example projects by project types.

24 POWER TRANSMISSION AND DISTRIBUTION↗

McGrath Community Energy Planning

The City of McGrath, a remote Alaskan community reliant on diesel fuel, developed a Community Energy Plan through the Energy Technologies Innovation Partnership Project (ETIPP) to address high energy costs, infrastructure vulnerabilities, and long-term sustainability. Guided by community-led priorities and technical assistance from partners including NREL, REAP, and ANTHC, the plan identifies eight focus areas: distribution system upgrades, solar and battery integration, river energy potential, emergency backup power, housing efficiency, water system losses, independent power producer models, and targeted funding strategies. The plan combines local knowledge with technical analysis to chart a path toward a more resilient, affordable, and sustainable energy future for McGrath.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Digital Grid Twin–Direct Communication Scheme Test Bed for Assessing Relay-to-Relay Radio Antenna and Optical Fiber Performance and Misoperations

This study introduces a novel “Digital Grid Twin–Direct Communication Scheme” test bed. This advanced platform evaluates point-to-point communication between transmitter and receiver relays with optical fiber and radio omnidirectional antenna systems, implemented at the Advanced Protection lab in the Grid Research Innovation and Development Center at Oak Ridge National Laboratory. The increased diversity of energy sources has led to more protective relay misoperations. In North America, microgrid protection schemes now use point-to-point communication along distribution lines between relays to implement advanced logic in nonradial grids that include both high- and low-inertia generators. This trend challenges utilities to minimize misoperations while ensuring rapid fault clearance and accurate selectivity coordination between primary and backup relays. This study assesses relay-to-relay communication schemes by introducing an advanced testing platform based on a digital grid twin protection test bed using a synchronized time source system. The platform evaluates the communication system using radio antennas or optical fiber links by integrating protective relays that operate breakers within the digital twin and record relay events and communication signals. In the experiments, transmitter and receiver relays were configured with inverse time overcurrent and breaker trip detection logic to assess the total time of the communication protection schemes based on the sum of the relay protection element operating time, radio latency, propagation delay, baud rate delay, and relay processing time. These delays were derived from recorded relay events and communication signals from the interface of a real-time simulator set as a digital grid twin. The test bed successfully simulated various electrical faults along a distribution line while ensuring effective and reliable point-to-point communication between transmitter and receiver relays. The radio antenna communication system exhibited latency because of the radio. This latency depends on the baud rate setting and type of radio application; in general, the higher the baud rate, the lower the radio latency. The measured radio latency (for Mirrored Bits with an encryption card at 9,600 bps) was about 9–10 ms. Additionally, calculated propagation delay per mile for radio antennas and optical fiber was 5.36 µs/mi and 8.04 µs/mi, respectively. Optical fiber communication did not demonstrate radio latency. Instead, the protection element operating time depends mainly on the protection logic function set in the relay, and the relay processing time depends on the processing rate of the relay in samples per power system cycle.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microgrid Hardening Design Toolkit: Puerto Rico Use Case

This document provides a comprehensive example of the microgrid hardening framework and the Sandia developed Microgrid Hardening Design Toolkit v0.27 using a census tract in a coastal area of southern Puerto Rico as a case study. The census tract (72123953100) is located in the municipality of Salinas. Currently, the La Margarita neighborhood within this census tract is part of the Department of Energy’s Cohort 5 of the Energy Technology Innovation and Partnership Program (ETIPP). The neighborhood’s local energy cooperative, Abeyno Coop, has been operating several residential solar photovoltaic (PV) and battery energy storage system (BESS) installations (with around 30 rooftop solar systems as of 2026). As part of the ETIPP project, Abeyno Coop is planning to integrate a larger microgrid into the existing distribution feeder in the area, including solar PV and BESS to supply energy for homes and critical loads such as the medical facilities and the community center that provides emergency shelter and backup power during outages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of Commercially Available Proprietary Vehicle-to-Home Systems: A V2X Connect Project Report

Bidirectional charging and Vehicle-to-Home (V2H) technologies enable the energy stored in a plug-in hybrid electric vehicle’s (PHEV) or battery electric vehicle’s (BEV) onboard battery to supply residential loads during grid outages and support broader energy management objectives. Conventional backup solutions, such as Uninterruptible Power Supplies (UPS) and standalone inverter systems, are limited in capacity and scalability, whereas PHEV/BEV-based storage offers substantially greater energy reserves that can sustain household loads for extended periods.

33 ADVANCED PROPULSION SYSTEMS↗