Search NASA⌕ Search

SEARCH · Search NASA

Results for “Base heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Design and Analysis of an Integrated Additively Manufactured Test Article for Plasma-Facing Components

Current plasma-facing components (PFCs) used in helium-cooled divertor modules are complex structures with tungsten tile, steel sleeve components, and cartridges, all assembled in a helium-cooled multiple jet (HEMJ) structure. The goal of this project is to simplify the complex PFC design using additive manufacturing techniques to create a single integrated tungsten test article. Apart from the flexibility this opens up in exploring a wide array of geometries for the article, having a single integrated article significantly reduces the number of joints and parts in the article, thus reducing chances of leaks. A process called electron beam melting has shown to produce very high-density samples and unique geometries, enabling HEMJ or similar designs. To validate and optimize this novel design, the model underwent a series of computational fluid dynamics and finite element analysis simulations to replicate steady-state heat flux in the divertors. The simulations presented in this study consider a steady-state base heat flux of 5 MW/m 2 , with water serving as the coolant. Future research will explore the use of helium as a coolant, simulate edge-localized-mode conditions, and include experimental validation. Since 3D-printed tungsten is anisotropic, the build direction versus build plane of the article are taken into consideration for the test article strength. Because of the high operating temperatures and low ductility of tungsten, thermal creep and brittle fracture are important failure mechanisms to consider. In conclusion, the cap is evaluated with various flow velocities and nozzle diameters, and an optimal design choice is made for which this cap will survive the divertor conditions with a conservative safety margin.

Divertor↗

Techno-economic feasibility of geothermal energy production using inactive oil and gas wells for district heating and cooling systems in Tuttle, Oklahoma

Oil and gas wells have been drilled in the United States and often encounter hot co-produced water possibly suitable for geothermal direct-use applications. Here this study evaluated geothermal resources, heating and cooling demand, and techno-economic potential of four oil and gas wells repurposed for geothermal energy production to serve two public schools and 250 nearby houses in Tuttle, Oklahoma, USA. Subsurface geology in the study area primarily consists of Permian to Mississippian sandstone and limestone formations approximately from 2 km to 3.5 km depth. With a geothermal gradient of 25.3 °C/km, the temperature of geothermal energy production was estimated as 68.2 °C at 2.1 km. The potential of calcite scaling within boreholes and pipes was minimal. Using the characterized reservoir properties, techno-economic analyses were conducted for evaluating levelized costs of geothermal energy production for direct-use heating and cooling and district heating systems with five different production scenarios. Heating and cooling demand in two schools and 250 houses and additional 0.3 MW and 0.6 MW base heating loads for potential geothermal direct-use applications in the study area were also incorporated in the modeling. Results indicated that the levelized cost of heating of geothermal district heating systems utilizing existing wells were significantly lower than those of conventional geothermal energy systems that include well drillings. The geothermal energy production with doublet and quartet configurations was generally sufficient to supply total annual heating demand in the district, while a peaking boiler was used to supply peak loads. Doublet configurations showed higher production temperature with a lower thermal drawdown than the quartet configurations. The doublet system at 2.1 km production depth with 9.3 kg/s flow rate represented the optimal levelized cost of $71/MWh and 91.2% utilization factor. These results imply that the Tuttle geothermal district heating system is techno-economically feasible and comparable to geothermal district heating systems in the United States and the regional natural gas rate for residentials by recycling inactive oil and gas wells with no drillings.

15 GEOTHERMAL ENERGY↗

Modeling Tool Development and Validation for Solar Industry Process Heat Using Particle Thermal Energy Storage

U.S. industry sectors used 26.2 quadrillion Btu and accounted for 33% of total energy consumption in 2021 according to the Energy Information Agency. Industrial process heat accounts for 70% of industrial energy use with application temperatures ranging from 60 degrees -1100 degrees C. Industry processes, heavily relying on fossil fuels of cheap coal or natural gas, differ widely in operating conditions and load requirements which makes them difficult to standardize and imposes great challenges in decarbonization. Industry processes require reliable energy supply and vary widely in temperature ranges. Storing energy from renewable sources is necessary to improve reliability and to mitigate renewable intermittency when replacing carbon fuel-based heat supplies to achieve energy savings and reduce emissions. To this end, we have developed a particle-based thermal energy storage (TES) technology using low-cost and highly stable silica sand as a storage medium. The economic and performance-based analysis is key for renewable energy sources to reliably supply industry process heat and ultimately displace fossil fuels for decarbonization. The diversified industrial processes need case-by-case analysis and design. Therefore, an adaptive modeling tool is key for renewable power with energy storage to meet industry demands. Thus, a modeling tool to simulate a solar industry process heat system using the particle TES has been developed using the object-oriented equation-based language Modelica and the commercial platform of Modelon Impact. The Modelica-based software tool provides a general simulation environment for the design of reliable solar energy sources integrated with TES for various industrial process applications at different temperatures for economic competence with fossil fuels such as coal and natural gases. It uses both customized and standard component modeling modules in Modelon libraries for the flexibility to be adapted to a specific energy demand application. The particle TES system establishes a uniform energy supply platform with an efficient heat exchanger and particle thermal energy reservoir integrated with renewable powers. The particle TES system can provide a wide temperature range and can have a large storage temperature difference that increases storage energy density; therefore, it can be an adaptable energy storage system integrated with renewable power to supply 24/7 heat for industry decarbonization.

concentrated solar thermal↗

Tariff Setting in the District Heating Sector: Recommendations Based on International Experience

Ukraine’s district heating (DH) system is an essential resource for the country and has the potential to provide efficient, local, and renewable energy to a large share of the population. However, inefficient regulation and management have caused the sector to experience a vicious cycle of financial, operational, and technological problems. Overcoming these challenges and building a sustainable DH system requires comprehensive reforms, which could attract significant investment, improve the quality of services, and increase the efficiency of DH. One of the key elements of a comprehensive reform program should be a comprehensive reform of the tariff system. The purpose of this report is to provide analysis of European models for tariff regulation and recommendations for reforms to Ukraine’s DH tariff system. The report presents several case studies from European countries, followed by analysis of the current tariff system in Ukraine and barriers to effective regulation. Based on these findings, the report proposes actions Ukraine could take to improve the tariff regulatory system and promote a sustainable DH sector.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Identifying Molecular Scale Interactions of Nucleating Agents with Salt Hydrates for Thermal Energy Storage Applications

Latent heat based thermal energy storage is of interest as a method to mitigate and time-shift thermal load peaks and hence reduce energy demands for heating and cooling buildings. Notably, Glauber’s salt (GS) presents a good choice as a phase change material (PCM) for building applications because it has a melting point near room temperature (i.e., 32.4 °C), a large heat of fusion and energy density, and is low cost (~ $100/ton). However, there are several known limitations to using GS as a PCM, such as incongruent melting, high degree of supercooling, and formation of other hydration states, which renders GS unsuitable for practical use. Inorganic crystals acting as nucleating agents can avoid some of these issues with GS [1]. Understanding nucleation behavior through typical calorimetry experiments offers limited insight into the molecular-scale mechanisms. Here, we report isothermal titration calorimetry [2] to investigate the interactions between sodium sulfate salt and an organic nucleating agent - glycine. Our experiments provide qualitative and quantitative understanding of how glycine interacts with sodium sulfate across various temperatures. The findings offer insights into the nucleation onset temperature (24°C) and underscore the pivotal role of glycine's zwitterionic structure in facilitating nucleation. This preliminary work provides a foundation for subsequent exploration of nucleating agents that would be incorporated in different salt hydrate systems. 1. Purohit, B. K., and V. S. Sistla. "Inorganic salt hydrate for thermal energy storage application: A review." Energy Storage 3, no. 2 (2021): e212. 2. Velázquez-Campoy, Adrián, Hiroyasu Ohtaka, Azin Nezami, Salman Muzammil, and Ernesto Freire. "Isothermal titration calorimetry." Current protocols in cell biology 23, no. 1 (2004): 17-8.

calorimetry, nucleation & growth↗

Optofluidic memory and self-induced nonlinear optical phase change for reservoir computing in silicon photonics

Nanophotonics allows to employ light-matter interaction to induce nonlinear optical effects and realize non-conventional memory and computation capabilities, however to date, light-liquid interaction was not considered as a potential mechanism to achieve computation on a nanoscale. Here, we experimentally demonstrate self-induced phase change effect which relies on the coupling between geometric changes of thin liquid film to optical properties of photonic waveguide modes, and then employ it for neuromorphic computing. In our optofluidic silicon photonics system we utilize thermocapillary-based deformation of thin liquid film capable to induce nonlinear effect which is more than one order of magnitude higher compared to the more traditional heat-based thermo-optical effect, and allowing operation as a nonlinear actuator and memory element, both residing at the same compact spatial region. The resulting dynamics allows to implement Reservoir Computing at spatial region which is approximately five orders of magnitude smaller compared to state-of-the-art experimental liquid-based systems.

42 ENGINEERING↗

Modelling and Simulation of a Thermoelectric Heat Pump with Micro-Channel Heat Transfer

Thermoelectric heat pumps (TEHPs) have advantages of modularity and simple design for heating and cooling in some applications. Models of thermoelectric (TE) heat pumps are widely studied. Nevertheless, most existing modeling work focuses on the TE material or air-sourced TE modules. TEHP modeling, especially the relationship between modules and heat exchangers, has not been comprehensively conducted. This work presents a water-to-water TEHP modeling framework that combines Goldsmid’s approach for TE material performance, Gnielinski’s correlation for convective heat transfer, and thermal balance theory for heat exchange networks. This combined framework provides an accurate theoretical analysis of the water-to-water TEHP system. Subsequently, the framework was used to empirically determine TE material properties (electric resistivity, thermal conductivity, and Seebeck coefficient) that minimize modeling errors versus experimentally observed values from the literature. Finally, an additional set of experimental TEHP data was used to validate the model, all with relative absolute deviations of approximately 10% when predicting heating capacity and 10%–20% when forecasting cooling capacity at a 30 K temperature lift. For future work, people can further develop models of TEHPs with an air-based heat sink on one side and water channels on the other side.

Wan, Hanlong↗

In Situ High-Temperature Ultrafast Electron Diffraction through Integrated Furnace and MEMS Platforms

Temperature fundamentally governs phase stability, defect evolution, and transport behavior in materials. Despite its central role, direct measurements of structural evolution at elevated temperatures on ultrafast timescales have remained limited. Here, we report the design, integration, and validation of 2 complementary in situ heating platforms that substantially extend the thermal operating range of ultrafast electron diffraction (UED). A compact furnace-type heating stage enables stable diffraction measurements from room temperature to 800 K with ±0.1 K stability under ultrahigh vacuum, achieved through multi-sensor feedback control, dual air-cooling channels, and a thermally isolated motion stage. In parallel, a microelectromechanical system (MEMS)-based heating platform provides rapid thermal response and access to extreme temperatures ≥1,373 K with ±0.1 K stability over hundreds-micrometer regions while supporting simultaneous electrical biasing for electrothermal coupling studies. Absolute temperature calibration is established using diffraction-based thermometry via aluminum lattice expansion and independently validated through in situ melting of bismuth thin films. UED measurements further reveal pronounced temperature-dependent nonequilibrium lattice dynamics in bismuth, including modifications to electron–phonon coupling and Debye–Waller behavior, as well as enhanced ultrafast diffuse scattering in aluminum at elevated temperatures. Together, these developments establish a practical framework for quantitative, time-resolved studies of temperature-driven kinetics and nonequilibrium structural dynamics under extreme thermal environments.

Bai, Qianqian [Chinese Academy of Sciences (CAS), ↗

Comparative Performance of Low Global Warming Potential (GWP) Refrigerants as Replacement for R-410A in a Regular 2-Speed Heat Pump for Sustainable Cooling

Heat pumps are currently being developed to reduce the energy footprint for residential and commercial building space conditioning and water heating loads in cold climates. To mitigate the nocuous impact of greenhouse gas emissions on the environment, and to create a carbon-neutral building stock, alternate lower-GWP refrigerants must also replace the predominant use of R-410A, without re-engineering the mechanical hardware. In this paper, we analyze the performance of lower-GWP alternative refrigerants (R-32, R-452B, R-454B, and R-466A) relative to the conventional R-410A and draw conclusions on the relative performances to meet cooling loads. The simulations are accomplished using the heat pump design model, a well-known, public-domain design tool with a free web interface and downloadable desktop version to support public use and the HVAC R&D community. The contributions contain detailed, hardware-based heat exchanger and system analyses to provide a comprehensive assessment. The results of the simulation are scrutinized from the first (capacity and energy efficiency) and second laws (exergy analysis) to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate lower-GWP refrigerants to replace R-410A using the same hardware. The results have practical value in engineering heat pumps in an economy that is compelled to alter by the consequences and uncertainties of climate change, to reduce its anthropogenic carbon footprint.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Split Heat Pump Using Low GWP Refrigerants

Conventional refrigerants, e.g. R-410A have high global warming potentials (GWP) > 1800. They are being phased out to protect the environment. The candidates to replace R-410A include R-32, R-452B, R-454B and R-466A for heat pump applications. These candidates are intended for drop-in replacement, i.e. having minimum modifications on existing systems. The paper investigates the low GWP refrigerants drop-in application via system simulations using a well-regarded, hardware-based heat pump model. A baseline heat pump having all fin-and-tube heat exchangers and a two-speed compressor was used. Cross-comparisons were made under rated conditions of ambient temperatures, compressor speeds, indoor air flow rates, respectively for cooling and heating operations. The seasonal performance indices, i.e. SEER and HSPF are presented.

Shen, Bo↗

Seasonal performance evaluation of zero-superheat active refrigerant charge control for variable-speed heat pumps

Heat pumps account for a significant portion of electricity consumption in buildings, making their energy efficiency a critical area of research. Control optimization is recognized as an effective approach for enhancing the efficiency of building HVAC systems. Specifically, since the efficiency of heat pumps increases with reduced superheat and the optimal refrigerant charge level varies with operating conditions, zero-superheat active charge control is a promising strategy to maximize the system’s COP. However, due to its complexity, this control strategy remains in the research phase and has only been tested under limited operating conditions. This paper proposes a methodology to evaluate the seasonal performance improvement of zero-superheat active charge control across a full range of heating conditions in buildings. The methodology includes the development of an optimal controller that utilizes an accumulator to store excess refrigerant and manages the active charge level at zero superheat through subcooling control, as well as the creation of a detailed physics-based heat pump model. Targeted a 3-ton variable-speed heat pump with R410A refrigerant, we selected ten U.S. cities representing different climate regions for seasonal performance evaluation. Our simulations indicate that, depending on the climate conditions, the optimal control strategy could achieve energy savings ranging from 5.8 % to 8.0 % over the entire heating season. These results suggest that zero-superheat active charge control, combined with coordinated compressor and fan speeds, could substantially improve the energy efficiency of heat pump systems while maintaining the required heating capacity.

Guo, Fangzhou↗

An Optimization-Based HVAC Load and PV Disaggregation Methodology With Contextual Supervision

Here, this letter presents an optimization-based Heating, Ventilation, and Air Conditioning (HVAC) and PV disaggregation approach. This letter builds on the previous works of authors, which discuss HVAC disaggregation strategy for aggregated levels without requiring sub-metered information. This letter expands on previous works to discuss optimization-based HVAC disaggregation by varying PV penetration scenarios with joint disaggregation of HVAC load and PV.

Analytics↗

Nuclear Thermal Energy Storage Configurations for Industrial Combined Heat and Power Supply: Conceptual Study and Engineering Designs

The industries examined in this report primarily rely on moderate-temperature heat provided by gas- or coal-fired boilers and combined heat and power (CHP) plants, delivered through standard process steam systems. High-temperature energy demands are often industry-specific and typically exceed the capabilities of high-temperature gas-cooled reactors (HTGRs). While it is technically feasible to replace process steam from fossil-based heat sources with nuclear energy, certain industries, such as methanol production and pulp and paper, face technoeconomic challenges in integrating nuclear energy without major changes or a technological shift. This is mainly due to the limited external energy demand remaining after the use of internal byproducts, waste heat recovery, and simple efficiency improvements. Achieving full decarbonization of these processes with nuclear energy would require significant technological advancements, involving experimental technology and substantial investments, making widespread adoption in existing industrial plants unlikely in the near term. This study reviews TES options in the context of enabling a flexible CHP supply while maintaining a steady nuclear heat input. Heat storage systems that interface between the reactor primary fluid and the CHP system offer superior performance and flexibility. Specifically, steam extraction downstream of the reheater with a two-tank molten-salt TES appears as the best solution regarding thermodynamic system benefits and system drawbacks. Using selected system configurations, a conceptual design of an industrial energy park was developed for industries with varying energy demands, such as steel production plants utilizing electric arc furnaces (EAFs) and chemical plants, as well as for those with constant energy demands, like petroleum refineries. This design highlights the capabilities of TES and explores its potential business cases. The study also conceptually develops the potential for integrating additional energy sources with nuclear systems through the implementation of TES. The potential of the HTGR-TES-CHP system was also evaluated considering key uncertainties such as industrial demand profiles, external grid access availability, and eligible tax credit levels, using the Holistic Energy Resource Optimization Network. Sensitivity of net present value to these uncertainties was analyzed to determine the optimal number of nuclear reactors (and CHP systems) and the suitable TES capacity. The results were interpreted from a decision-maker’s perspective, focusing on three key areas: deployment strategy (oversized units vs. undersized units with TES support), industrial process characteristics (thermal-intensive single profiles vs. electricity-intensive combined profiles), and operational goals (maximizing profits vs. minimizing natural gas (NG) consumption or external grid dependence). The optimization results indicate that the HTGR-TES-CHP system significantly reduces reliance on NG boilers for individual industrial processes by 9-60% (in NG capacity factor), with an average reduction of 38%, compared to standalone NG boiler operation case (Business As Usual [BAU]). For combined industrial processes, the reduction ranges from 37-77%, with an average of 60%. Additionally, the system greatly reduces dependence on external grids. In meeting industrial electrical demands, a 33-100% self-sufficient internal electricity supply is achieved for single industrial process, with an average of 74%, compared to the BAU scenario, where 100% of electricity is imported. For combined processes, 35-100% of internal electricity demands are met by the reactor, with an average of 73%. At last, the relative NG price levels at which the proposed HTGR-TES-CHP system can cost-effectively enter the market currently dominated by existing NG boilers were estimated. For a moderate HTGR CAPEX level ($\$$2500/kWth, $\$$6329/kWe), the analysis suggests that NG prices must be 2.5 to 7 times higher than HTGR variable operating and maintenance costs for single industrial process, and 5.5 to 9.5 times higher for a combined process scenario. Tax credit modeling shows that the Investment Tax Credit significantly reduces the price threshold needed to break even, making the system competitive with NG boilers in certain cases.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

Thermal Integration of Advanced Nuclear Reactors with a Reference Refinery, Methanol Synthesis, and a Wood Pulp Plant (Rev.1)

The present report is intended to provide process flow diagrams (PFDs) and energy and mass balance data sheets for a U.S. industrial sector subset with which nuclear heat and power could be integrated—a subset that includes the oil refining, methanol and pulp and paper industries. Coupling options for integrating nuclear energy into these industries are quantitatively outlined for reference systems, and future work will extend this analysis in greater detail. Opportunities for integrating small modular nuclear reactors (SMNRs) were investigated for each of the industrial process configurations. Aspen HYSYS and Cycle-Tempo models for a high-temperature gas-cooled reactor were developed to evaluate the proposed integration. This introductory evaluation provides a general description and assessment of the operating principles, reactor coolant core outlet temperature, and reactor size to be integrated with industry. The industrial processes of oil refining and the production of methanol, pulp and paper were simulated by using Aspen HYSYS, Aspen Plus, and the PRELIM (Petroleum Refinery Life Cycle Inventory Model) tool to develop process details. Cycle-Tempo models then extend the process modeling results to obtain net energy demands (e.g., heat, steam, and electricity) when accounting for process steam and waste heat recovery. This information is intended to foster the analysis of integrating an SMNR to decarbonize industrial facilities. The SMNR would provide reliable, competitive, and sustainable clean energy while reducing carbon emissions and other environmental impacts, such as water withdrawals, consumption, and contamination. The refining industry, exhibited in Figure ES1, is a leading consumer of fossil -fuel-based heat, power, and hydrogen in the U.S. industrial sector, generating over 164 million metric tons (MMT) of CO 2 emissions in 2023. The overall mass and energy pertaining to a generalized complex refinery in the United States is reflected in Figure ES1, along with energy metrics regarding integration with a nuclear power plant (NPP). Data sheets were developed to indicate the energy requirements for the overall refinery and each refinery process. The data sheet for the overall refinery is shown in Table ES2.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Calibration approach and range of observed sap flow influences transpiration estimates from thermal dissipation sensors

Calibrating thermal dissipation (TD) sap flow sensors has become increasingly important to accurately estimate whole-tree transpiration, but it is unclear how the calibration approach itself influences the resulting coefficients and estimates. Here, we compare the two most common calibration approaches, gravimetric and potometric, using TD sensors inserted into Eucalyptus benthamii tree stems. The gravimetric approach uses an excised stem segment devoid of branches and leaves and pushes water through the stem using gravity, a positive force. The potometric approach uses a severed stem containing an intact canopy placed upright in a reservoir where water is pulled through the stem via transpiration, a negative force. We hypothesized that the positive pressure associated with gravimetric calibration would overestimate conductive sapwood area relative to that estimated from potometric calibration and that coefficients from these different approaches would result in different estimates of transpiration when applied to intact trees. We also predicted that calibrations could improve transpiration estimates by targeting the range of observed sap flow rates (i.e., K values) in intact trees. Conductive sapwood area was higher under gravimetric calibrations and resulting estimates of transpiration were lower compared to potometric calibrations. Segmented calibration curves, which fit two separate curves for the relationship between sap flux density (Fd) and sap flux index (K) based on the range of sap flow rates observed in intact trees, increased transpiration estimates from both gravimetric and potometric coefficients and diminished the magnitude of difference in transpiration estimates between approaches. Researchers should be aware that calibration approach and range of observed sap flow profoundly influences transpiration estimates from TD sensors and this likely applies to calibrations of other heat-based sap flow sensors.

54 ENVIRONMENTAL SCIENCES↗

Methodology for interpretable reinforcement learning model for HVAC energy control

Deep reinforcement learning (DRL) approaches have been used in various application areas to improve efficiency, optimization, or automation. However, very little is known about how the DRL algorithms make decisions and what features affect their performance. Using a case study of a DRL based Heating, Ventilation and Air Conditioning (HVAC) optimization methodology, we demonstrate how we can address these challenges by applying interpretability tools and systematically exploring the model inputs for better understanding the DRL behaviour and decision making process. We developed a methodology for interpretable reinforcement learning and evaluated our approach in real-world house located in Knoxville, TN. Our findings explain the reasoning behind DRL-based optimization decisions under different circumstances which has been discussed and confirmed by the experts in the field.

Kotevska, Olivera↗

MFRED, 10 second interval real and reactive power for groups of 390 US apartments of varying size and vintage

Abstract Building electricity is a major component of global energy use and its environmental impacts. Detailed data on residential electricity use have many interrelated research applications, from energy conservation to non-intrusive load monitoring, energy storage, integration of renewables, and electric vs. fossil-based heating. The dataset presented here, Multifamily Residential Electricity Dataset (MFRED), contains the electricity use of 390 apartments, ranging from studios to four-bedroom units. All apartments are located in the Northeastern United States (IECC-climate-zone 4 A), but differ in their heating/cooling system and construction year (early to late 20 th century). To adhere to privacy guidelines, data were averaged across 15 apartments each, based on annual electricity use. MFRED includes real and reactive power, at 10-second resolution, for January to December 2019 (246 million data points). The annual average real power per apartment is 343 W (3.27 W/m 2 of floor area), with strong variation between seasons and apartment size. Considering its large number of apartments, high time resolution, real and reactive power, and 12-month duration, MFRED is currently unique for the multifamily-sector.

97 MATHEMATICS AND COMPUTING↗