Search NASA⌕ Search

SEARCH · Search NASA

Results for “Battery failure analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Fire Protection Engineering Technical Report for Electric Vehicles and Lithium-Ion Batteries

This fire protection engineering technical report discusses and presents the properties, data, and safety of select lithium-ion batteries. Lithium-ion batteries have increased in usage and a fire scenario analysis must be created for each situation where they may be introduced in buildings to determine the risk associated if a battery failure were to occur.

25 ENERGY STORAGE↗

LogPath: Log data based energy consumption analysis enabling electric vehicle path optimization

Vehicle navigation and path optimization require a more meticulous approach when it deals with EVs (electric vehicles) and SDVs (software-defined vehicles), due to lengthy charging times and the lack of charging infrastructure. Long-distance freight EV trucking needs path guidance with accurate energy consumption estimates to prevent charging-related failures. We developed a novel energy consumption estimation approach that only uses battery log data to extract major vehicle parameters to increase EV navigation accuracy without additional sensors. This is enabled by extracting multiple drive modes from the log data for analysis. The system provides 1) routes, 2) charge locations, 3) charging times, and 4) optimal vehicle speeds that guarantee the shortest travel time. Here we successfully validated the system using log data collected from an EV and Tesla's Supercharging map in the US and compared it with the commercially available navigation system, Tesla's trip planner, whose capabilities solely include charging time and routing.

EV (Electric vehicles) navigation↗

Correlative acoustic time-of-flight spectroscopy and X-ray imaging to investigate gas-induced delamination in lithium-ion pouch cells during thermal runaway

It remains difficult to detect internal mechanical deformation and gas-induced degradation in lithium-ion batteries, especially outside specialized diagnostics laboratories. In this work, we demonstrate that electrochemical acoustic time-of-flight (EA-ToF) spectroscopy can be used as an insightful and field-deployable diagnostic/prognostic technique to sense the onset of failure. A 210 mAh commercial lithium-ion cell undergoing thermal abuse testing is probed with in situ and operando EA-ToF spectroscopy, together with simultaneous fractional thermal runaway calorimetry (FTRC) and synchrotron X-ray imaging. The combination of X-ray imaging and EA-ToF analysis provides new understanding into the through-plane mechanical deformation in lithium-ion batteries through direct visualisation and the acoustic ToF response. Internal structural changes, such as gas-induced delamination, are identified using EA-ToF spectroscopy due to variations in the attenuation and signal peak shifts. This is corroborated using X-ray imaging, demonstrating EA-ToF spectroscopy as a promising technique for detecting onset of battery failure.

25 ENERGY STORAGE↗

Mechanistic understanding of aging behaviors of critical-material-free Li 4 Ti 5 O 12 //LiNi 0.9 Mn 0.1 O 2 cells with fluorinated carbonate-based electrolytes for safe energy storage with ultra-long life span

Behind-the-meter storage (BTMS) systems - a viable method to minimize potential risk of blackout events and stabilize the grid - require a different type of cost-effective energy storage with excellent safety, ultra-long (>20 years) cycle life and reasonable energy density compared that of electric vehicles. To increase the energy density and reduce the cost of a long-term cyclable lithium-titanate-based cell, it is required to employ a critical-material-free high voltage cathode and an electrolyte with good electrochemical and transport properties. In this report the long-term electrochemical performance and behaviors of selected critical-material-free Li 4 Ti 5 O 12 (LTO)//LiNi 0.9 Mn 0.1 O 2 (LNMO) full cells for BTMS applications are evaluated and analyzed in the optimized voltage range of 1.4-2.7 V at 45 degrees C with different fluorinated carbonate-based electrolytes. The fluoroethylene carbonate (FEC)-based electrolyte cell shows the highest capacity retention of 57.9% and Coulombic efficiency (CE) of 99.96% after 1000 cycles, potentially attributed to a dense, homogenous and less resistive LiF-rich solid-electrolyte interphase (SEI) layer formed on the surface of LTO that may mitigate electrolyte decomposition and maintain relatively low cell impedance during cycling. The 3,3,3-fluoroethylmethyl carbonate (F-EMC)-based electrolyte cell, however, presents the worst performance with lower capacity and a sharp decrease of CE, due to unstable and non-uniform SEI formation and continuous oxidative electrolyte decomposition. This mechanistic understanding of cell aging behaviors and failure mechanisms with detailed analysis of surface chemistry and electrode morphology can guide design of new electrode chemistries and electrolyte formulations for the development of BTMS batteries.

25 ENERGY STORAGE↗

ASCEND: Asymptotically compatible strong form foundations for nonlocal discretization

Nonlocal models naturally handle a range of physics of interest to SNL, but discretization of their underlying integral operators poses mathematical challenges to realize the accuracy and robustness commonplace in discretization of local counterparts. This project focuses on the concept of asymptotic compatibility, namely preservation of the limit of the discrete nonlocal model to a corresponding well-understood local solution. We address challenges that have traditionally troubled nonlocal mechanics models primarily related to consistency guarantees and boundary conditions. For simple problems such as diffusion and linear elasticity we have developed complete error analysis theory providing consistency guarantees. We then take these foundational tools to develop new state-of-the-art capabilities for: lithiation-induced failure in batteries, ductile failure of problems driven by contact, blast-on-structure induced failure, brittle/ductile failure of thin structures. We also summarize ongoing efforts using these frameworks in data-driven modeling contexts. This report provides a high-level summary of all publications which followed from these efforts.

97 MATHEMATICS AND COMPUTING↗

Microstructural Analysis of the Effects of Thermal Runaway on Li-Ion and Na-Ion Battery Electrodes

Thermal runaway is a phenomenon that occurs due to self-sustaining reactions within batteries at elevated temperatures resulting in catastrophic failure. Here, the thermal runaway process is studied for a Li-ion and Na-ion pouch cells of similar energy density (10.5 Wh, 12 Wh, respectively) using accelerating rate calorimetry (ARC). Both cells were constructed with a z-fold configuration, with a standard shutdown separator in the Li-ion and a low-cost polypropylene (PP) separator in the Na-ion. Even with the shutdown separator, it is shown that the self-heating rate and rate of thermal runaway in Na-ion cells is significantly slower than that observed in Li-ion systems. The thermal runaway event initiates at a higher temperature in Na-ion cells. The effect of thermal runaway on the architecture of the cells is examined using X-ray microcomputed tomography, and scanning electron microscopy (SEM) is used to examine the failed electrodes of both cells. In conclusion, from examination of the respective electrodes, likely due to the carbonate solvent containing electrolyte, it is suggested that thermal runaway in Na-ion batteries (NIBs) occurs via a similar mechanism to that reported for Li-ion cells.

25 ENERGY STORAGE↗

Characterising thermal runaway within lithium-ion cells by inducing and monitoring internal short circuits

Lithium-ion batteries are being used in increasingly demanding applications where safety and reliability are of utmost importance. Thermal runaway presents the greatest safety hazard, and needs to be fully understood in order to progress towards safer cell and battery designs. Here, we demonstrate the application of an internal short circuiting device for controlled, on-demand, initiation of thermal runaway. Through its use, the location and timing of thermal runaway initiation is pre-determined, allowing analysis of the nucleation and propagation of failure within 18 650 cells through the use of high-speed X-ray imaging at 2000 frames per second. Furthermore, the cause of unfavourable occurrences such as sidewall rupture, cell bursting, and cell-to-cell propagation within modules is elucidated, and steps towards improved safety of 18 650 cells and batteries are discussed.

30 DIRECT ENERGY CONVERSION↗

Evolution and Degradation Patterns of Electrochemical Cells Based on the Analysis of Interfacial Phenomena at Li Metal Anode/Electrolyte Interfaces

In this work, we report the results of a theoretical–computational analysis of the solid electrolyte interphase (SEI) growth and degradation dynamics occurring in lithium metal batteries during cycling. We use ab initio-kinetic Monte Carlo simulations to generate a synthetic data set, which is analyzed by machine learning methods. We aim to determine: (i) how modifications in interfacial interaction energies between solid electrolyte interphase (SEI) blocks and between Li ions and SEI facets impact the Coulombic efficiency (CE) of the battery and (ii) what factors, including reactions, microscopic transport, and other interfacial events, may lead to cell performance “failure” during prolonged charge and discharge cycles, signaled as a sharp decay in the CE over cycling. The demonstration of our approach is done on a cell including a Li metal surface interfacing with a previously introduced state-of-the-art electrolyte, and the idea can be applied to any electrochemical system. Outcomes include the identification of the leading chemical, physical, and structural variables causing cell failure and relating them to the electrolyte formulation, thus paving the way to future more refined analysis and electrolyte design.

batteries↗

Efficient Simulation and Abuse Modeling of Mechanical-Electrochemical-Thermal Phenomena in Lithium-Ion Batteries

NREL's Energy Storage team is exploring the effect of mechanical crush of lithium ion cells on their thermal and electrical safety. PHEV cells, fresh as well as ones aged over 8 months under different temperatures, voltage windows, and charging rates, were subjected to destructive physical analysis. Constitutive relationship and failure criteria were developed for the electrodes, separator as well as packaging material. The mechanical models capture well, the various modes of failure across different cell components. Cell level validation is being conducted by Sandia National Laboratories.

25 ENERGY STORAGE↗

A knowledge-based system for monitoring the electrical power system of the Hubble Space Telescope

The design and the prototype for the expert system for the Hubble Space Telescope's electrical power system are discussed. This prototype demonstrated the capability to use real time data from a 32k telemetry stream and to perform operational health and safety status monitoring, detect trends such as battery degradation, and detect anomalies such as solar array failures. This prototype, along with the pointing control system and data management system expert systems, forms the initial Telemetry Analysis for Lockheed Operated Spacecraft (TALOS) capability.

Eddy, Pat↗

Exploring thermal runaway propagation in Li-ion batteries through high-speed X-ray imaging and thermal analysis: Impact of cell chemistry and electrical connections

Battery safety design is important to consider from the individual Li-ion cell to the level of the macro-system. On the macro-level, failure in one single cell can lead to propagation of the thermal runaway and rapidly set a whole battery pack on fire. Factors that can impact the propagation outcome, such as cell model/chemistry and electrical connection are here investigated using a combination of measurements. Several abusive tests were conducted, combining two different cell models (Molicel P42A and LG M50, both 21700s) in series and parallel connections (16 tests per configuration). Overall, a propagation outcome of 56% was measured from the 32 conducted tests, a minimum temperature of 150 °C was required to initiate propagation, and the fastest propagation occurred in 123 s. Temperature measurements were higher in series connected cells, initiating the discussion of cell chemistry and internal resistance on this effect. The difference in current-flow during thermal runaway in series and parallel connections, and how this can affect the temperature evolution is further discussed. Spatio-temporal mapping of X-ray radiography allowed us to derive the speed of thermal runaway evolution inside the battery and has shown that series connected cells, in particular P42A, occur faster. It was further observed that deviant sidewall behaviors such as temperature-induced breaches and pressure-induced ruptures occurred in P42As only respective nail-penetrated cells only.

25 ENERGY STORAGE↗

Failure mechanisms of single-crystal silicon electrodes in lithium-ion batteries

Long-term durability is a major obstacle limiting the widespread use of lithium-ion batteries in heavy-duty applications and others demanding extended lifetime. As one of the root causes of the degradation of battery performance, the electrode failure mechanisms are still unknown. In this paper, we reveal the fundamental fracture mechanisms of single-crystal silicon electrodes over extended lithiation/delithiation cycles, using electrochemical testing, microstructure characterization, fracture mechanics and finite element analysis. Anisotropic lithium invasion causes crack initiation perpendicular to the electrode surface, followed by growth through the electrode thickness. The low fracture energy of the lithiated/unlithiated silicon interface provides a weak microstructural path for crack deflection, accounting for the crack patterns and delamination observed after repeated cycling. On the basis of this physical understanding, we demonstrate how electrolyte additives can heal electrode cracks and provide strategies to enhance the fracture resistance in future lithium-ion batteries from surface chemical, electrochemical and material science perspectives.

25 ENERGY STORAGE↗

Evaluation program for secondary spacecraft cells: Cycle life test

The service life and storage stability for several storage batteries were determined. The batteries included silver-zinc batteries, nickel-cadmium batteries, and silver-cadmium batteries. The cell performance characteristics and limitations are to be used by spacecraft power systems planners and designers. A statistical analysis of the life cycle prediction and cause of failure versus test conditions is presented.

Harkness, J. D.↗

Battery Thermal Characterization

A well-designed thermal management system is critical to the life and performance of electric-drive vehicles (EDVs) hybrids (HEVs), plug-in hybrids (PHEVs), and all-electric vehicles (EVs). Temperature and temperature uniformity both significantly affect the performance, lifespan, and safety of vehicle energy storage devices. NREL conducts thermal management research and development (R&D) to optimize battery performance and extend useful life. A recognized leader in battery thermal analysis and characterization, NREL evaluates electrical and thermal performance of battery cells, modules, and packs, full energy storage systems, and the interaction of these systems with other vehicle components. The lab's performance assessments factor in the design of the thermal management system, the thermal behavior of the cell, battery lifespan, and safety of the energy storage system, as well as full integration into a vehicle. The lithium-ion (Li-ion) batteries found in most of today's electric-drive vehicles are smaller and more lightweight than previous nickel-metal hydride (NiMH) technology, but they are also more sensitive to overheating, overcharging, and extreme spikes in temperature known as thermal runaway. High temperatures diminish battery life and increase battery replacement costs, while low temperatures decrease battery power and capacity, all of which impact vehicle range, performance, and affordability. NREL's breakthrough research is focused on reducing thermal barriers to achieve more uniform temperatures. NREL uses its R&D 100 Award-winning Isothermal Battery Calorimeters, the only instruments in the world capable of such precise thermal measurements, for much of this research. Calorimeter readings are paired with thermal imaging of batteries using infrared cameras to evaluate battery temperature distribution. In addition, NREL is working with industry to develop computer-aided engineering software tools to optimize thermal management of batteries. NREL's analysis for the U.S. Advanced Battery Consortium (USABC) show that optimized thermal management can increase battery power by more than 10%. Without proper thermal management, an EDV battery can last more than 10 years in a temperate climate, like in Minnesota, but only 7 years in a hot climate, such as in Arizona. In extreme instances, battery overheating can pose safety hazards, including fires. Performance: Maintaining desired temperature ranges is critical in optimizing EDV battery storage capacity, lifespan, and performance, and eventually impacts cost and consumer acceptance. NREL's breakthrough research focuses on achieving more uniform temperatures while a vehicle is in motion and actively generating heat, as well as when it is parked and exposed to ambient temperatures over prolonged periods of time. Safety: Most energy storage systems deliver maximum performance at higher temperatures. However, this extreme heat can overload systems and create dangerous conditions. NREL evaluation helps to more effectively regulate thermal characteristics, providing greater safeguards and stronger performance. NREL has invented a device that emulates internal short circuits in batteries to better understand how to prevent future failures and related hazards.

25 ENERGY STORAGE↗

Quantitative Analysis of Origin of Lithium Inventory Loss and Interface Evolution over Extended Fast Charge Aging in Li Ion Batteries

During the extreme fast charging (XFC) of lithium-ion batteries, lithium inventory loss (LLI) and reaction mechanisms at the anode/electrolyte interface are crucial factors in performance and safety. Determining the causes of LLI and quantifying them remain an essential challenge. We present mechanistic research on the evolution and interactions of aging mechanisms at the anode/electrolyte interface. We used NMC 532 /graphite pouch cells charged at rates of 1, 6, and 9 C up to 1000 cycles for our investigation. The cell components were characterized after cycling using electrochemical measurements, inductively coupled plasma optical emission spectroscopy, 7 Li solid-state nuclear magnetic resonance spectroscopy, and high-performance liquid chromatography/mass spectrometry. The results indicate that cells charged at 1 C exhibit no Li plating, and the increase of SEI thickness is the dominant source of the Li loss. In contrast, Li loss in cells charged at 9 C is related to the formation of the metallic plating layers (42%) the SEI layer (38.1%) and irreversible intercalation into the bulk graphite (19%). XPS analysis suggests that the charging rate has little influence on the evolution of SEI composition. The interactions between competing aging mechanisms were evaluated by a correlation analysis. In conclusion, the quantitative method established in this work provides a comprehensive analytical framework for understanding the synergistic coupling of anodic degradation mechanisms, forecasting SEI failure scenarios, and assessing the XFC lithium-ion battery capacity fade.

25 ENERGY STORAGE↗

A Discussion of the Failure of a Quad Diode Module and Efforts to Assure the Flight Spares

In 2019 the International Space Station (ISS) experienced an on on-orbit failure that affected 1 of 28 Battery Charge Discharge Units (BCDUs). Telemetry pointed to a short circuit failure of a Power Rectifier Quad Diode Module. Astronauts removed the failed unit from service which was then returned to Earth for failure analysis. The failure analysis confirmed that the quad diode module had failed short circuit. The investigation identified silver dendrites had grown on the insulated, sloped edge of the mesa semiconductor die of the failed diode and also a 2nd diode in the same quad diode module. Voids between the diode’s protective encapsulating ring and the die provided space within which dendrites were able to form and cause catastrophic failure. The NASA Engineering & Safety Center (NESC) convened a EEE Parts Sub-Team to investigate root cause and to assist with risk assessment for all of the flight diode modules (4 distinct production lots) and the flight spares (from a 5th lot). Analysis of the original diode manufacturer’s read and record screening test data identified some lots which contained diodes with parametric instabilities that could signal conditions suited for silver dendrite formation. Computed Tomography (CT) X-ray screening inspection was performed on flight spare modules to identify diodes that do not exhibit voids between the edge of die and encapsulating ring as a mitigation against dendrite formation.

Jay Brusse↗