Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam sensitive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

X-Ray Absorption near Edge Structure Spectroscopic Study of Hayabusa Category 3 Carbonaceous Particles

Analyses with a scanning transmission x-ray microscope (STXM) using x-ray absorption near edge structure (XANES) spectroscopy were applied for the molecular characterization of two kinds of carbonaceous particles of unknown origin, termed category 3, which were collected from the Hayabusa spacecraft sample catcher. Carbon-XANES spectra of the category 3 particles displayed typical spectral patterns of heterogeneous organic macromolecules; peaks corresponding to aromatic/olefinic carbon, heterocyclic nitrogen and/or nitrile, and carboxyl carbon were all detected. Nitrogen-XANES spectra of the particles showed the presence of N-functional groups such as imine, nitrile, aromatic nitrogen, amide, pyrrole, and amine. An oxygen-XANES spectrum of one of the particles showed a ketone group. Differences in carbon- and nitrogen-XANES spectra of the category 3 particles before and after transmission electron microscopic (TEM) observations were observed, which demonstrates that the carbonaceous materials are electron beam sensitive. Calcium-XANES spectroscopy and elemental contrast mapping identified a calcium carbonate grain from one of the category 3 particles. No fluorine-containing molecular species were detected in fluorine-XANES spectra of the particles. The organic macromolecular features of the category 3 particles were distinct from commercial and/or biological ‘fresh (non-degraded)’ polymers, but the category 3 molecular features could possibly reflect degradation of contaminant polymer materials or polymer materials used on the Hayabusa spacecraft. However, an extraterrestrial origin for these materials cannot currently be ruled out.

Asteroides↗

The Baryon Mapping Experiment (BMX), a 21cm intensity mapping pathfinder

The Baryon Mapping eXperiment (BMX) is an interferometric array designed as a pathfinder for a future post- reionization 21 cm intensity mapping survey. It consists of four 4-meter parabolic reflectors each having offset pyramidal horn feed, quad-ridge orthomode transducer, temperature-stabilized RF amplification and filtering, and pulsed noise injection diode. An undersampling readout scheme uses 8-bit digitizers running at 1.1 Gsamples/sec to provide access to signals from 1.1 - 1.55 GHz (third Nyquist zone), corresponding to HI emission from sources at redshift 0 < z < 0.3. An FX correlator is implemented in GPU and generates 28 GB/day of time-ordered visibility data. About 7,000 hours of data were collected from Jan. 2019 - May 2020, and we will present results on system performance including sensitivity, beam mapping studies, observations of bright celestial targets, and system electronics upgrades. BMX is a pathfinder for the proposed PUMA intensity mapping survey in the 2030s.

79 ASTRONOMY AND ASTROPHYSICS↗

Understanding In-Situ Structure and Chemistry at Battery Interfaces Through Time-Resolved Cryo-EM

Transmission and scanning transmission electron microscopy are vital tools for characterizing interfacial structure and chemistry at high spatial resolutions but are limited by the fact that many materials are quickly damaged by electron beam irradiation. This is a challenge particularly for materials relevant to energy applications, such as lithium-containing battery materials, organic-inorganic hybrids, and liquid electrolytes. Cryogenic electron microscopy (cryo-EM) offers a partial solution to this issue by stabilizing beam-sensitive solid-solid or solid-liquid interfaces for characterization, but typical cryo-EM sample preparations are ex situ and thus cannot capture interfaces in their electrified state of interest to applications. Here, we present a method to prepare cryo-EM samples of electrified battery interfaces in situ to preserve the time-resolved structures and chemistry that arise under applied current or bias.

batteries↗

Dual-Cantilever-Beam Accelerometer

Sensitivity to velocity changes along beam axis reduced. Weighted-end cantilever beams of accelerometer deflected equally by acceleration in y direction. When acceleration to right as well as up or down, right beam deflected more, while left beam deflected less. Bridge circuit averages outputs of strain gauges measuring deflections, so cross-axis sensitivity of accelerometer reduced. New device simple and inexpensive.

Reynolds, Emmitt A.↗

Physical origin of the frequency shifts in cesium beam frequency standards: Related environmental sensitivity

When observed in a cesium beam frequency standard, the hyperfine transition frequency of the atoms differs slightly from the invariant transition frequency of the unperturbed atoms at rest. The various physical and technical origins of the frequency offsets are stated. They relate to fundamental physical effects, to the method of probing the atomic resonance and to the frequency control of the slaved oscillator. The variation of the frequency offsets under a change of the value of the internal operating characteristics is considered. The sensitivity to a change of the magnetic induction, the microwave power, and the temperature is given. A comparison is made of the sensitivity of cesium beam frequency standards of the commercially available type, making use of magnetic state selection, and of devices under study, in which the state preparation and detection is accomplished optically. The pathways between the external stimuli and the physical origin of the frequency offsets are specified.

Audoin, Claude↗

Multi-Wavelength, Multi-Beam, and Polarization-Sensitive Laser Transmitter for Surface Mapping

A multi-beam, multi-color, polarized laser transmitter has been developed for mapping applications. It uses commercial off-the-shelf components for a lowcost approach for a ruggedized laser suitable for field deployment. The laser transmitter design is capable of delivering dual wavelengths, multiple beams on each wavelength with equal (or variable) intensities per beam, and a welldefined state of polarization. This laser transmitter has been flown on several airborne campaigns for the Slope Imaging Multi-Polarization Photon Counting Lidar (SIMPL) instrument, and at the time of this reporting is at a technology readiness level of between 5 and 6. The laser is a 1,064-nm microchip high-repetition-rate laser emitting energy of about 8 microjoules per pulse. The beam was frequency-doubled to 532 nm using a KTP (KTiOPO4) nonlinear crystal [other nonlinear crystals such as LBO (LiB3O5) or periodically poled lithium niobiate can be used as well, depending on the conversion efficiency requirements], and the conversion efficiency was approximately 30 percent. The KTP was under temperature control using a thermoelectric cooler and a feedback monitoring thermistor. The dual-wavelength beams were then spectrally separated and each color went through its own optical path, which consisted of a beam-shaping lens, quarterwave plate (QWP), and a birefringent crystal (in this case, a calcite crystal, but others such as vanadate can be used). The QWP and calcite crystal set was used to convert the laser beams from a linearly polarized state to circularly polarized light, which when injected into a calcite crystal, will spatially separate the circularly polarized light into the two linear polarized components. The spatial separation of the two linearly polarized components is determined by the length of the crystal. A second set of QWP and calcite then further separated the two beams into four. Additional sets of QWP and calcite can be used to further split the beams into multiple orders of two. The spatially separated beams had alternating linearly polarization states; a half-wave plate (HWP) array was then made to rotate the alternating states of A multi-beam, multi-color, polarized laser transmitter has been developed for mapping applications. It uses commercial off-the-shelf components for a lowcost approach for a ruggedized laser suitable for field deployment. The laser transmitter design is capable of delivering dual wavelengths, multiple beams on each wavelength with equal (or variable) intensities per beam, and a welldefined state of polarization. This laser transmitter has been flown on several airborne campaigns for the Slope Imaging Multi-Polarization Photon Counting Lidar (SIMPL) instrument, and at the time of this reporting is at a technology readiness level of between 5 and 6. The laser is a 1,064-nm microchip high-repetition-rate laser emitting energy of about 8 microjoules per pulse. The beam was frequency-doubled to 532 nm using a KTP (KTiOPO4) nonlinear crystal [other nonlinear crystals such as LBO (LiB3O5) or periodically poled lithium niobiate can be used as well, depending on the conversion efficiency requirements], and the conversion efficiency was approximately 30 percent. The KTP was under temperature control using a thermoelectric cooler and a feedback monitoring thermistor. The dual-wavelength beams were then spectrally separated and each color went through its own optical path, which consisted of a beam-shaping lens, quarterwave plate (QWP), and a birefringent crystal (in this case, a calcite crystal, but others such as vanadate can be used). The QWP and calcite crystal set was used to convert the laser beams from a linearly polarized state to circularly polarized light, which when injected into a calcite crystal, will spatially separate the circularly polarized light into the two linear polarized components. The spatial separation of the two linearly polarized components is determined by the length of the crystal. A cond set of QWP and calcite then further separated the two beams into four. Additional sets of QWP and calcite can be used to further split the beams into multiple orders of two. The spatially separated beams had alternating linearly polarization states; a half-wave plate (HWP) array was then made to rotate the alternating states of

Yu, Anthony W.↗

Identification and evaluation of linear damping models in beam vibrations

Sensitive method, identifying effective damping mechanisms, involves comparing experimentally determined ratio of first to second mode magnification factors related to common point on beam. Cluster size has little effect on frequencies of elements, magnification factor decreases with cluster size, and viscous and stress damping are dominant damping mechanisms.

Boers, B. L.↗

Contrast analysis in two-beam laser interference lithography

Interference lithography enables large area, sub-µm, periodic patterning without photomasks or projection lithography tools. We show that optical contrast, which is the fundamental design variable of interference lithography, enforces coupled constraints on source coherence, beam pointing stability, field size, polarization state, and the intensity balance between beams. The analysis enables selection and alignment tolerance of components to meet a specific design requirement. In particular, the analysis reveals that grating beam splitters are significantly less sensitive to beam pointing and polarization misalignment than plate beam splitters.

Miller, David B. (ORCID:0000000207755284)↗

Optical Monitoring of Weld Penetration

Robotic welding controlled by reliable, relatively-noise-free optoelectronic unit. Bounding off meniscus of pool of molten metal, laser beam impinges on position-sensitive photodetector. Beam diameter adjusted for width of weld. Optical filters screen out light from arc. Made from small, low-cost components and utilizing optical fibers to conduct signals, system immune to electromagnetic interference common in industrial environments. Aimed for automatic welders, robot welders in particular and also adaptable to other types of welding, including tungsten/inert-gas, laser, and electron-beam techniques.

Maram, J.↗

Beam results for the new super-conducting booster at Jefferson Lab

The performance results of a new super-conducting booster for the CEBAF injector at Jefferson Lab, could be of interest for other similar electron injectors. A recent addition of this new booster has provided us the ability to achieve a more adiabatic acceleration and therefore an improvement to the beam dynamics and beam brightness. It has also simplified the design and operation of the section of the injector responsible for accelerating the electron beam from a few hundred keV to several MeV (typically 6.7 MeV). The addition of the new booster was part of an upgrade to the CEBAF injector to improve the beam quality for future physics experiments with high sensitivity to beam quality. The booster consists of two cavities: a 2-cell cavity followed by a 7-cell cavity. This combination allows for a wide range of input electron beam energies, from 130 keV to more than 300 keV. In fact, during the last year, the booster was successfully operated with 140,180, and 200 keV input beam energies as the electron gun was being upgraded. This paper describes the new booster, presents beam optics data results from different beam studies, commissioning, and the physics quality beam operation.

Accelerator Physics↗

Pressurized Gas Beam Monitor for Extremely High Intensities – Phase II

A novel pressurized gas-filled multi-RF-cavity beam profile monitor has been studied that is simple and robust in high-radiation environments. Charged particles passing through each RF-cavity in the monitor produce intensity-dependent ionized plasma, which changes the gas permittivity. Standard RF techniques to measure the change in quality factor (Q) and frequency (f) as a function of time are then used to determine the change in permittivity and corresponding beam intensity in each cavity in the profile monitor. The sensitivity to beam intensity is adjustable using gas pressure and RF gradient. The performance of the gas-filled beam profile monitor has been numerically simulated to evaluate the sensitivity of permittivity measurements and the effectiveness of calibration strategies. An entire multi-RF-cavity system has been designed and a demonstration test has been prepared.

43 PARTICLE ACCELERATORS↗

Electro-optic sampling beam position monitor for relativistic electron beams

Here, an electro-optic sampling beam position monitor for installation at the SLAC National Accelerator Laboratory FACET-II facility is described. Simulations of the detector signal were performed using realistic electron beam current profiles, demonstrating that this single-shot, non-destructive, compact detector is capable of resolving the relative transverse offset and longitudinal separation of an ultra-relativistic, two-bunch electron beam to order 1 μm and 10 fs, respectively. A design study was performed to optimize the detector’s response to the ultra-relativistic two-bunch electron beam utilized in plasma wakefield accelerator experiments. In addition, the expected sensitivity to beam tilt is studied for typical electron beams used in free electron lasers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A mass sensitivity analysis of lunar orbiting beam power systems

At NASA Lewis Research Center, the feasibility of beaming power from orbiting satellites to the surface of the moon was studied. Reference microwave and laser beam power concepts were found to be 1/3 to 1/6 the mass of surface solar systems. Further analysis was performed to determine the sensitivity of the reference concepts to technology performance levels and mission architecture scenarios, such as beaming to multiple surface sites and lunar rovers. Previous studies concluded that frequencies above 35 GHz for the microwave systems were not critical for reducing the main base mass; however, when multiple sites and rovers are considered, this may become necessary. In addition, for the laser system, the pointing accuracy of the satellites becomes a critical factor for rover applications. These issues and other important results of the parametric studies, are discussed.

Stavnes, Mark W.↗

Modeling of joints for the dynamic analysis of truss structures

An experimentally-based method for determining the stiffness and damping of truss joints is described. The analytical models use springs and both viscous and friction dampers to simulate joint load-deflection behavior. A least-squares algorithm is developed to identify the stiffness and damping coefficients of the analytical joint models from test data. The effects of nonlinear joint stiffness such as joint dead band are also studied. Equations for predicting the sensitivity of beam deformations to changes in joint stiffness are derived and used to show the level of joint stiffness required for nearly rigid joint behavior. Finally, the global frequency sensitivity of a truss structure to random perturbations in joint stiffness is discussed.

Belvin, W. Keith↗

Probing BSM Oscillatory Signals with the DUNE Detectors and the LBNF Neutrino Beam: NSI and Sterile Neutrino Sensitivities

The Deep Underground Neutrino Experiment (DUNE) is a flagship long-baseline accelerator neutrino experiment under construction in the U.S. With a 1,300 km distance between its Near Detector (ND) and Far Detector (FD), the world’s most intense LBNF (Long-Baseline Neutrino Facility) neutrino beam, and high-resolution LArTPC (Liquid Argon Time Projection Chamber) detectors, DUNE will measure the neutrino oscillation parameters with unprecedented precision. In addition to the determination of the neutrino mass ordering and the potential discovery of Charge-Parity violation in the leptonic sector, DUNE's capabilities present a unique opportunity for probing Beyond the Standard Model (BSM) physics signals with neutrinos. Examples of BSM physics manifestations include the presence of Non-Standard Interactions (NSI) of neutrinos with matter, or the existence of sterile neutrinos that mix with 3-Flavor neutrinos. In this study, we present a joint ND+FD fit to simulated data assessing DUNE's sensitivity to probing neutrino NSI, as well as scenarios including sterile neutrino mixing.

Prais, Luiz [Cincinnati U.] (ORCID:000000018224947↗