Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam sensitive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Pressurized Gas Beam Monitor for Extremely High Intensities – Phase II

A novel pressurized gas-filled multi-RF-cavity beam profile monitor has been studied that is simple and robust in high-radiation environments. Charged particles passing through each RF-cavity in the monitor produce intensity-dependent ionized plasma, which changes the gas permittivity. Standard RF techniques to measure the change in quality factor (Q) and frequency (f) as a function of time are then used to determine the change in permittivity and corresponding beam intensity in each cavity in the profile monitor. The sensitivity to beam intensity is adjustable using gas pressure and RF gradient. The performance of the gas-filled beam profile monitor has been numerically simulated to evaluate the sensitivity of permittivity measurements and the effectiveness of calibration strategies. An entire multi-RF-cavity system has been designed and a demonstration test has been prepared.

43 PARTICLE ACCELERATORS↗

Electro-optic sampling beam position monitor for relativistic electron beams

Here, an electro-optic sampling beam position monitor for installation at the SLAC National Accelerator Laboratory FACET-II facility is described. Simulations of the detector signal were performed using realistic electron beam current profiles, demonstrating that this single-shot, non-destructive, compact detector is capable of resolving the relative transverse offset and longitudinal separation of an ultra-relativistic, two-bunch electron beam to order 1 μm and 10 fs, respectively. A design study was performed to optimize the detector’s response to the ultra-relativistic two-bunch electron beam utilized in plasma wakefield accelerator experiments. In addition, the expected sensitivity to beam tilt is studied for typical electron beams used in free electron lasers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Probing BSM Oscillatory Signals with the DUNE Detectors and the LBNF Neutrino Beam: NSI and Sterile Neutrino Sensitivities

The Deep Underground Neutrino Experiment (DUNE) is a flagship long-baseline accelerator neutrino experiment under construction in the U.S. With a 1,300 km distance between its Near Detector (ND) and Far Detector (FD), the world’s most intense LBNF (Long-Baseline Neutrino Facility) neutrino beam, and high-resolution LArTPC (Liquid Argon Time Projection Chamber) detectors, DUNE will measure the neutrino oscillation parameters with unprecedented precision. In addition to the determination of the neutrino mass ordering and the potential discovery of Charge-Parity violation in the leptonic sector, DUNE's capabilities present a unique opportunity for probing Beyond the Standard Model (BSM) physics signals with neutrinos. Examples of BSM physics manifestations include the presence of Non-Standard Interactions (NSI) of neutrinos with matter, or the existence of sterile neutrinos that mix with 3-Flavor neutrinos. In this study, we present a joint ND+FD fit to simulated data assessing DUNE's sensitivity to probing neutrino NSI, as well as scenarios including sterile neutrino mixing.

Prais, Luiz [Cincinnati U.] (ORCID:000000018224947↗

Beam Energy Dependence of the Linear and Mode-Coupled Flow Harmonics Using the a Multi-Phase Transport Model

In the framework of the A Multi-Phase Transport (AMPT) model, the multi-particle azimuthal cumulant method is used to calculate the linear and mode-coupled contributions to the quadrangular flow harmonic (v4) and the mode-coupled response coefficient as functions of centrality in Au+Au collisions at sNN = 200, 39, 27 and 19.6 GeV. This study indicates that the linear and mode-coupled contributions to v4 are sensitive to beam energy change. Nevertheless, the correlations between different-order flow symmetry planes and the mode-coupled response coefficients show weak beam energy dependence. In addition, the presented results suggest that the experimental measurements that span a broad range of beam energies can be an additional constraint for the theoretical model calculations.

79 ASTRONOMY AND ASTROPHYSICS↗

Laser beam pointing stabilization using analog position-sensitive diodes

Laser wire scanners have been used for ion beam profile and emittance measurements at the Spallation Neutron Source linear accelerator. Due to propagation distances exceeding 100 m, reliable measurements require laser beam stabilization, previously accomplished with a feedback control loop using a digital camera as a position sensor [Hardin et al., Opt. Express 19, 2874 (2011)]. Here, this paper presents an upgraded pointing stabilization system utilizing analog position-sensitive diodes (PSDs) as the position detector, optimized with an optical diffuser. The new system significantly surpasses the previous system by offering an order-of-magnitude improvement in radiation tolerance and a bandwidth limited only by the burst repetition rate of the laser beam. Operating with a 60-Hz burst mode laser, the new system effectively suppresses laser beam drifts up to 30 Hz, compared to the previous system’s 4 Hz limit. In addition, the amplitude of spectral components below 0.1 Hz was reduced by a factor of more than 100, which is over seven times greater than was achieved by the previous system.

Data acquisition↗

Atomically resolved edges and defects in lead halide perovskites

Although edges and defects constitute only a small fraction of crystalline materials, they exert an outsized impact on a material′s properties. Organic–inorganic halide perovskites are promising next-generation semiconductor materials with superior cost effectiveness and interesting optoelectronic properties. However, clear images of their edges have remained challenging to obtain owing to their extreme sensitivity. Using truly high-speed ultralow-dose four-dimensional scanning transmission electron microscopy with dose fractionation, we perform ptychography at, to our knowledge, the lowest-dose atomic resolution to date, revealing not only the detailed atomic structure of the edges of a halide perovskite but also their structural dynamics. Here, a majority methylammonium (MA) and iodine (I) edge termination is observed in methylammonium lead iodide (MAPbI 3 ), and the damage rate of its edges and internal defects is found to depend on the concentration and type of vacancies present, with a preponderance of I vacancies in particular correlating with higher rates of damage.

4D-STEM↗

Benchmarking of X‐Ray Fluorescence Microscopy with Ion Beam Implanted Samples Showing Detection Sensitivity of Hundreds of Atoms

Abstract Single impurities in insulators are now often used for quantum sensors and single photon sources, while nanoscale semiconductor doping features are being constructed for electrical contacts in quantum technology devices, implying that new methods for sensitive, non‐destructive imaging of single‐ or few‐atom structures are needed. X‐ray fluorescence (XRF) can provide nanoscale imaging with chemical specificity, and features comprising as few as 100 000 atoms have been detected without any need for specialized or destructive sample preparation. Presently, the ultimate limits of sensitivity of XRF are unknown – here, gallium dopants in silicon are investigated using a high brilliance, synchrotron source collimated to a small spot. It is demonstrated that with a single‐pixel integration time of 1 s, the sensitivity is sufficient to identify a single isolated feature of only 3000 Ga impurities (a mass of just 350 zg). With increased integration (25 s), 650 impurities can be detected. The results are quantified using a calibration sample consisting of precisely controlled numbers of implanted atoms in nanometer‐sized structures. The results show that such features can now be mapped quantitatively when calibration samples are used, and suggest that, in the near future, planned upgrades to XRF facilities might achieve single‐atom sensitivity.

36 MATERIALS SCIENCE↗

Pulsed-Beam Transmission Electron Microscopy and Radiation Damage

Here, we review the use of pulsed electron-beams in transmission electron microscopes (TEMs) for the purpose of mitigating specimen damage. We begin by placing the importance of TEMs with respect to materials characterization into proper context, and we provide a brief overview of established methods for reducing or eliminating the deleterious effects of beam-induced damage. We then introduce the concept of pulsed-beam TEM, and we briefly describe the basic methods and instrument configurations used to create so-called temporally structured electron beams. Following a brief overview of the use of high-dose-rate pulsed-electron beams in cancer radiation therapy, we review historical speculations and more recent compelling but mostly anecdotal findings of a pulsed-beam TEM damage effect. This is followed by an in-depth technical review of recent works seeking to establish cause-and-effect relationships, to conclusively uncover the presence of an effect, and to explore the practicality of the approach. These studies, in particular, provide the most compelling evidence to date that using a pulsed electron beam in the TEM is indeed a viable way to mitigate damage. Throughout, we point out current gaps in understanding, and we conclude with a brief perspective of current needs and future directions.

36 MATERIALS SCIENCE↗

Ion beam profiling system and related methods

An ion beam profiling system include a beam profiling element, an ion sensitive element electrically isolated from the beam profiling element, an ion source configured to emit an ion beam at the beam profiling element and the ion sensitive element, and a current measuring device coupled to the ion sensitive element. The beam profiling element includes a plate of material having two parallel major surfaces, a first slit aperture extending through the plate of material and having a first longitudinal length extending in a direction parallel to the two parallel major surfaces, and a second slit aperture extending through the plate of material and having a second longitudinal length extending in a direction parallel to the two parallel major surfaces, wherein the first longitudinal length of the first slit aperture is perpendicular to the second longitudinal length of the second slit aperture.

Taylor, Chase N.↗

Dynamics of magnetic evaporative beamline cooling for the preparation of cold atomic beams

The most sensitive direct neutrino mass searches today are based on measurement of the end point of the 𝛽 spectrum of tritium to infer limits on the mass of the unobserved neutrino. To avoid the smearing associated with the distribution of molecular final states in the T-He molecule, the next generation of these experiments will need to employ atomic (T) rather than molecular (T 2 ) tritium sources, at currents of at least 10 15 atoms per second. Following production, atomic T can be trapped in gravitational and/or magnetic bottles for 𝛽 spectrum experiments, if and only if it can first be cooled to millikelvin temperatures. Accomplishing this cooling presents substantial technological challenges. The Project 8 collaboration is developing a technique based on magnetic evaporative cooling along a beamline (MECB) for the purpose of cooling T to feed a magnetogravitational trap that also serves as a cyclotron radiation emission spectroscope. Initial tests of the approach are planned in a pathfinder apparatus using atomic Li. Here, this paper presents a method for analyzing the dynamics of the MECB technique and applies these calculations to the design of systems for cooling and slowing of atomic Li and T. A scheme is outlined that could provide a current of T at the millikelvin temperatures required for the Project 8 neutrino mass search.

atom optics↗

Digital Miniature Cathode Ray Magnetometer

In this study, we introduce the concept and construction of an innovative Digital Miniature Cathode Ray Magnetometer designed for the precise detection of magnetic fields. This device addresses several limitations inherent to magnetic probes such as D.C. offset, nonlinearity, temperature drift, sensor aging, and the need for frequent recalibration, while capable of operating in a wide range of magnetic fields. The core principle of this device involves the utilization of a charged particle beam as the sensitivity medium. The system leverages the interaction of an electron beam with a scintillator material, which then emits visible light that is captured by an imager. The emitted scintillation light is captured by a CMOS sensor. This sensor not only records the scintillation light but also accurately determines the position of the electron beam, providing invaluable spatial information crucial for magnetic field mapping. The key innovation lies in the combination of electron beam projection, CMOS imager scintillation-based detection, and digital image signal processing. By employing this synergy, the magnetometer achieves remarkable accuracy, sensitivity and dynamic range. The precise position registration enabled by the CMOS sensor further enhances the device’s utility in capturing complex magnetic field patterns, allowing for 2D field mapping. In this work, the optimization of the probe’s performance is tailored for applications related to the characterization of insertion devices in light sources, including undulators.

Turqueti, Marcos↗

Cross-beam energy transfer in direct-drive ICF. I. Nonlinear and kinetic effects

Results are presented from a series of simulations examining the susceptibility of the cross-beam energy transfer (CBET) instability to nonlinear processes in the context of direct-drive inertial confinement fusion experiments on the OMEGA laser facility. These form the basis for the second paper of this series [A. G. Seaton, L. Yin, R. Follett, B. J. Albright, and A. Le, “Cross-beam energy transfer in direct-drive ICF. II. Theory and simulation of mitigation through increased laser bandwidth,” Phys. Plasmas 29, 042707 (2022)], where we examine the efficacy of increases in laser bandwidth at suppressing CBET. We choose laser and plasma conditions for the simulations that are favorable to CBET and promote nonlinearity. Through a comparison of outputs from the particle-in-cell code vector particle in cell (VPIC) and the linearized fluid code laser-plasma simulation environment (LPSE), a series of nonlinear effects have been identified in the kinetic simulations that include particle trapping, the two-ion wave decay, and ion-acoustic wave self-focusing. These effects produce time-dependent energy transfer, in contrast to the linearized fluid simulations in which a steady state is reached after an initial transient. Ion trapping is shown to allow for increased energy transfer relative to fluid simulations, with the remaining nonlinear processes acting to reduce the energy transfer. Nonlinear dynamics is contrasted for low- and high-intensity beams as well as between speckled and planar beams. For the parameters under consideration, beam profile has a significant effect on nonlinear dynamics, though the greatest sensitivity is to beam intensity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Freeze It or Leave It? Evaluating the Role of Cryo-Electron Microscopy in Battery Research

Cryogenic electron microscopy (cryo-EM) continues to gain prominence in materials science, particularly in battery research where it has enabled high-resolution, multimodal characterization of electrode materials and interfaces that otherwise degrade quickly under electron beam irradiation. But as anyone who has attempted cryo-EM techniques knows, freezing comes at a cost; cryo-EM experiments are time-consuming, highly sensitive, and carry an increased risk of artifacts due to issues such as frost contamination. Thus, when planning new characterization of battery materials or other beam-sensitive samples, it is critical to consider whether (and which) cryo-EM techniques are appropriate, based on study goals and an understanding of electron beam-sample interactions. Here we review such considerations for battery materials to elucidate the questions of when, why, and how to freeze to achieve high-quality characterization.

25 ENERGY STORAGE↗

BEAM COLLIMATION IN THE PIP-II LINAC TO BOOSTER TRANSFER LINE

The new PIP-II superconducting linac will deliver a 2 mA average H⁻ beam to the existing Booster synchrotron. The injected beam is accumulated by charge exchange over approximately 300 turns; phase space painting is used to mitigate space charge effects. To limit the power load on the internal waste beam absorber from the transverse tails of the H⁻ distribution missing the foil, the beam will be collimated in both planes in the linac to Booster transfer line using compact collimators of a novel design. Both the number of parasitic hits and the fraction of the beam missing the foil are sensitive functions of the H⁻ beam centroid position with respect to the edge of the foil. The positioning of the collimation is constrained by the availability of suitable space in the transfer line lattice, by specifics of the collimator design, by the phase space orientation at the collimator, and by the betatron phase advance to the foil needed to achieve proper orientation of the spatial distribution at the injection point. In this contribution, we describe the procedure by which collimator positions were optimized. We then discuss the expected performance of the overall system.

Johnson, David E.↗

Stability of beta-induced Alfvén eigenmodes (BAE) in DIII-D

Although the stability of ellipticity, toroidal and reversed-shear Alfvén eigenmodes (EAE, TAE, RSAE) are relatively well understood, less is known about the stability of lower-frequency modes such as the beta-induced Alfvén eigenmode (BAE) but, because they are often unstable in present devices and are implicated in fast-ion transport, understanding their stability is vital. BAE stability is studied in primarily weak or reversed shear DIII-D plasmas with sub-Alfvénic deuterium beams. Modes are classified based on electron cyclotron emission, beam emission spectroscopy, magnetics, and interferometer data. The study is limited to the initial two seconds of the discharge, where the evolving q profile provides an effective scan of the dependence of stability upon q. In a dedicated experiment, BAEs are unstable at times in the discharge when the minimum of the safety factor q min is close to a rational number. The observed mode frequencies are usually close to analytic estimates of the BAE accumulation point and the eigenfunction peaks in the vicinity of q min . Unstable BAEs usually occur in bursts that chirp rapidly in frequency. To isolate the importance of thermal and beam gradients in driving the modes, the beam and electron cyclotron heating power is altered for 50–100 ms durations in reproducible discharges. As expected from the resonance condition, BAEs depend sensitively on the beam power and injection geometry. Modes only persist for ~25 ms because the anisotropic beam population only interacts strongly with the modes over a relatively narrow range of q. Lastly, a database of over 1000 beam-heated discharges shows that BAEs are more likely to be unstable when the poloidal beta exceeds 0.5.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status of Error Correction Studies in Support of FFA@CEBAF

In this work, we examine the beam correction requirements for the FFA@CEBAF energy upgrade. Both hardware and software diagnostic and corrector components are under investigation; in particular the relationship between hardware and software optimization will be developed. To generate a representative sample of errors---from the machine lattice and other beam properties---we construct a Markov Chain Monte Carlo (MCMC) sampler which considers different probability distributions for different types of errors. This sample is used to investigate the statistical sensitivity of the beam to various diagnostic and corrective schema. Once statistics are acquired, we plan to use a variety of optimization techniques to minimize correction time for the electron beam in the FFA arcs designed for the CEBAF upgrade.

Benesch, J.↗

Optimization and active stabilization of a far-infrared laser for NSTX-U high poloidal wavenumber scattering diagnostics

The far-infrared (FIR) laser output beam power and profile are important parameters in the laser-aided diagnostics, directly influencing the spatial resolution and signal-to-noise ratio of measurements. Here, this work focuses on developing a systematic control method to enhance FIR laser beam quality through optimized mirror alignment and real-time feedback-based precision cavity length tuning. A 150 W CO 2 laser, aligned with the waveguide axis using a HeNe reference laser, serves as the pump source. The sensitivity of FIR beam intensity to pump gas pressure and thermal expansion is investigated, revealing that even a 1 µm cavity expansion can significantly degrade output power stability to about two-thirds of its original value. To address this, a feedback control module has been designed and implemented for active cavity length adjustment, stabilizing the output power at ∼30 mW. In addition, maintaining a high formic acid gas pressure ($>$190 mTorr) within the cavity ensures reliable operation. The optimized FIR laser will be deployed on the National Spherical Torus eXperiment-U high poloidal wavenumber scattering system for studying electron-scale turbulence in tokamak plasmas.

Xu, Xinhang [Univ. of California, Davis, CA (Unite↗