Search NASA⌕ Search

SEARCH · Search NASA

Results for “Biofouling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Self-Replenishing Vascularized Fouling-Release Surfaces

Inspired by the long-term effectiveness of living antifouling materials, we have developed a method for the self-replenishment of synthetic biofouling-release surfaces. These surfaces are created by either molding or directly embedding 3D vascular systems into polydimethylsiloxane (PDMS) and filling them with a silicone oil to generate a nontoxic oil-infused material. When replenished with silicone oil from an outside source, these materials are capable of self-lubrication and continuous renewal of the interfacial fouling-release layer. Under accelerated lubricant loss conditions, fully infused vascularized samples retained significantly more lubricant than equivalent nonvascularized controls. Tests of lubricant-infused PDMS in static cultures of the infectious bacteria Staphylococcus aureus and Escherichia coli as well as the green microalgae Botryococcus braunii, Chlamydomonas reinhardtii, Dunaliella sauna, and Nannochloropsis oculata showed a significant reduction in biofilm adhesion compared to PDMS and glass controls containing no lubricant. Further experiments on vascularized versus nonvascularized samples that had been subjected to accelerated lubricant evaporation conditions for up to 48 h showed significantly less biofilm adherence on the vascularized surfaces. These results demonstrate the ability of an embedded lubricant-filled vascular network to improve the longevity of fouling-release surfaces.

Howell, C↗

Biofilm formation behaviour of marine filamentous cyanobacterial strains in controlled hydrodynamic conditions

Summary Marine biofouling has severe economic impacts and cyanobacteria play a significant role as early surface colonizers. Despite this fact, cyanobacterial biofilm formation studies in controlled hydrodynamic conditions are scarce. In this work, computational fluid dynamics was used to determine the shear rate field on coupons that were placed inside the wells of agitated 12‐well microtiter plates. Biofilm formation by three different cyanobacterial strains was assessed at two different shear rates (4 and 40 s −1 ) which can be found in natural ecosystems and using different surfaces (glass and perspex). Biofilm formation was higher under low shear conditions, and differences obtained between surfaces were not always statistically significant. The hydrodynamic effect was more noticeable during the biofilm maturation phase rather than during initial cell adhesion and optical coherence tomography showed that different shear rates can affect biofilm architecture. This study is particularly relevant given the cosmopolitan distribution of these cyanobacterial strains and the biofouling potential of these organisms.

Romeu, Maria J.↗

Evaluation of Pre- and Post- Redevelopment Groundwater Chemical Analyses from LM Monitoring Wells

This report documents the efforts and analyses conducted for the Applied Studies and Technology (AS&T) Ancillary Work Plan (AWP) project titled Evaluation of Pre- and Post- Redevelopment Groundwater Sample Laboratory Analyses from Selected LM Groundwater Monitoring Wells. This effort entailed compiling an inventory of nearly 500 previous well redevelopment events at 16 U.S. Department of Energy Office of Legacy Management (LM) sites, searching the literature for impacts of well redevelopment on groundwater sample quality, and—the focus of this report—evaluating the impacts of well redevelopment on field measurements and sample analytical results. Study Catalyst Monitoring well redevelopment, the surging or high-volume pumping of a well to loosen and remove accumulated sediment and biological build-up from a well, is considered an element of monitoring well maintenance that is implemented periodically during the lifetime of the well to mitigate its gradual deterioration. Well redevelopment has been conducted fairly routinely at a few LM sites in the western United States (e.g., the Grand Junction office site and the Gunnison processing site in Colorado), but at most other sites in this region it is not a routine practice. Also, until recently (2014–2015), there had been no specific criteria for implementing well redevelopment, and documentation of redevelopment events has been inconsistent. A catalyst for this evaluation was the self-identification of these inconsistencies by the Legacy Management Support contractor. As a result, in early 2015 Environmental Monitoring Operations (EMO) staff began collecting and documenting additional field measurements during well redevelopment events. In late 2015, AS&T staff undertook an independent internal evaluation of EMO's well redevelopment records and corresponding pre- and post-well-redevelopment groundwater analytical results. Study Findings Although literature discussions parallel the prevailing industry-wide assumption that well redevelopment is necessary to increase production or to extend the life of a well, no data in the literature indicate that redevelopment affects chemical signatures in monitoring wells. The comprehensive evaluation undertaken for this study also yielded no evidence that redevelopment has any quantifiable or predictable effect on groundwater sample quality. Both short-term and long-term changes in groundwater chemistry were assessed relative to preceding and subsequent well redevelopment events. Although short-term changes in specific conductance or contaminant concentrations likely attributable to well redevelopment were found at some sites, these cases were limited to a small subset of wells in which chemical stratification had been observed. Redevelopment causes mixing of the well water, resulting in short-term impacts, but not in a consistent direction. Long-term groundwater concentration trends of uranium, the primary contaminant of concern at most LM Uranium Mill Tailings Radiation Control Act (UMTRCA) sites, were evaluated for all 16 sites addressed in this study. Based on the data evaluated, there are no apparent impacts of well redevelopment on uranium trends. In most cases where deviations in trends were found, these could be attributed to water level fluctuations or other factors. A few exceptions were found where spikes or marked decreases in uranium concentrations could potentially be related to the preceding well redevelopment, but apparent impacts were neither predictable nor quantifiable. Summary and Recommendations A catalyst for this project was a concern that there was a need for strict criteria for a program-wide approach to well redevelopment at LM sites. There was also an implicit question as to whether well redevelopment was a necessary practice that was being overlooked at some sites. The primary objective of this study was to determine if there are significant differences in laboratory analytical results between pre- and post-redevelopment groundwater samples. Results of this evaluation indicate that this is not the case—groundwater concentrations of uranium, the primary contaminant of concern at most LM UMTRCA sites, generally remained unchanged pre- and post-well-redevelopment. The literature supports redevelopment of monitoring and municipal wells if signs of reduced productivity, biofouling, sediment buildup, or other conditions potentially affecting long-term well integrity are observed. In these cases, use of a downhole camera to examine the condition of the well screen and casing may be useful. However, based on the data sets examined for this study, there is no evidence that well redevelopment is needed in order to obtain samples that have the same chemical concentrations as those in the groundwater. To conclusively demonstrate that point—that is, to define chemical effects—the underlying mechanisms have to be understood. For example, if biofouling is observed in a well and is considered a potential cause of spurious or invalid chemical data, appropriate hypothesis-testing ethodology should be used to test the validity of this claim. Until late 2014, the onset of this project, there was no standard procedure for documenting well redevelopment events; some (perhaps many) had not been captured in the historical record. EMO has made notable progress in this regard since 2015, having established a format for documenting well redevelopment events and associated field measurements, as well as a data repository for capturing those records. This policy should be continued to ensure that all well redevelopment events and associated field observations are recorded and easily tracked.

54 ENVIRONMENTAL SCIENCES↗

Permeation testing of thermal power plant cooling water impacts of Graphite Oxide (GO)/polymer membranes

The purpose of this project was to investigate how thermoelectric power plant cooling water impacts the energy demands, permeance, and ion rejection of GO/polymer membranes using extended permeation testing. Treatment of cooling tower blowdown water is challenging since this water contains scalants (e.g.: silica, calcium sulfate, calcium carbonate) which can precipitate on membranes, decreasing membrane efficiency and lifetime. In this collaboration with EPRI and a Southwestern US utility, the performance of GO/polymer membranes in desalinating cooling tower blowdown water from three natural-gas fueled power plants was evaluated. Results of cross-flow desalination test durations of three to four weeks demonstrated the long-term stability of the membranes. GO/polymer desalination membranes were shown to tolerate drinking-water level chlorination, which could reduce capital and operational costs. Biofouling and scale formation were minimal on the GO surface, suggesting that industry standard intensive cleaning steps could be reduced. Results also demonstrated pressure-tunable rejection which would allow treat-to-need water recycling, thus likely reducing energy costs for these membranes. Further development of biofouling and scaling resistant desalination membranes could lead to reduced cost for water treatment, potentially allowing for greater use of non-traditional water supplies for thermoelectric power plants.

Biedermann, Laura↗

Results of the SRNL Studies of the MCU Strip Effluent Coalescers

Three potential causes of the strip effluent (SE) coalescer (SEC) failure were investigated: inorganic fouling, organic fouling, and biological fouling. From the analysis of the SEC and leachate samples from the SEC, there is no evidence that the fouling is caused by inorganic precipitates, solids, or salts. The analysis of the SEC shows the presence of organic material such as sec-butylphenol and Modifier (1-(2,2,3,3-Tetrafluoropropoxy)-3-(4-secbutylphenoxy)-2- propanol). The source of the sec-butylphenol would be from the decomposition of the Modifier in the solvent. The analysis of the SEC shows the presence of amide bonds that are likely from bacteria and other biological material. In addition, samples from the Strip Feed Tank (StFT) and the boric acid delivery tanker showed the presence of bacteria and other biological material. The most likely cause of the SEC fouling is biofouling by bacteria and other organisms that form a biofilm on the SEC fibers. The biofilm would sorb organic material in the feed to the SEC, and not readily release this material. The bacteria would use this trapped organic material to grow the biofilm, which would decrease the porosity of the SEC. The biofilm would thereby impede SEC operation through biofouling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Microbial Communities as Indicators of Microbially Induced Corrosion Potential in Stainless Steel Piping

The 200 West Area Pump-and-Treat (200W P&T) facility is part of the final remedy decision for the 200 ZP-1 Operable Unit (OU) and is the interim remedial action for 200-UP-1 OU at the Hanford Site. The facility also treats water from other sources across the site, including 200-DV-1 OU perched water, groundwater from the 200-BP-5 OU, and leachate from the Environmental Restoration Disposal Facility. The facility originally operated a biological treatment process for nitrate that resulted in systemic biofouling and loss of injection well capacity, requiring frequent and costly well rehabilitation. Biofouling has also contributed to corrosion of welds and pitting of stainless-steel piping at the facility. The biological treatment for nitrate was suspended at the end of 2019 calendar year to eliminate negative impacts from biological treatments which improve facility operations and treatment of carbon tetrachloride. Evaluation of the 200W P&T facility’s response to operational improvements, specifically the suspension of the biological treatment, provides information on the potential for continued microbially induced corrosion (MIC). To this end, historical data sets (2015-2017) were compared with molecular biological analyses of 200W P&T water samples from 2018-2020 to quantify trends in total microbial biomass and specific microbial indicator species (iron, sulfate, nitrate, and manganese reducing bacteria) known to cause and enhance metal corrosion. Results showed unequivocal reductions (in excess of 90%) in all microbiological indicators measured following the suspension of the biological treatment. Although abundance measurements for all corrosive MIC populations initially declined after removal of the treatment system, nitrate-reducing bacteria (nirK) and sulfate-reducing bacteria remain highly abundant in the system, an order of magnitude higher than the number of cells present prior to the removal of the biological treatment system [5.14e (1.4) cells/L, vs. 1.14e (0.07) cells/L, reported as average (±SD) for n=3]. In addition, there was an unexpected inflection point in 2019 where all microbial indicators increased unexpectedly in abundance in 2020 by as much as two orders of magnitude compared to 2019 samples. Given the limited number of water samples available for this analysis, the cause of the increase in microbial indicators post-biological treatment has not yet been determined. Systematic sampling of the facility for continued monitoring is recommended so that the responses of MIC populations can be evaluated to ensure that further corrosion is avoided, allowing the 200W P&T facility to operate safely and efficiently at design capacity.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhancing Lifetime and Reducing Costs for Fish Diversion Netting Structures (Final Report)

In this effort Pacific Northwest National Laboratory (PNNL) developed and demonstrated an anti-fouling coating that is effective on fish diversion structures. The coating was based on a previously developed superhydrophobic lubricant infused composite (SLIC) coating but modified for application to flexible substrates. We showed that the new reformulated coating – FlexiSLIC – can be applied to flexible fibrous structures to significantly reduce biofouling of netting and anchor lines, to enable longer operational lifetimes, reduced costs, and more reliable operations. The coating developed in this effort was tested on relevant fish diversion structural netting and rope materials (e.g. nylon, Dyneema, polypropylene) to reduce biofouling. Engagement with industry in the development and demonstration further supported progress toward commercialization of the materials.

36 MATERIALS SCIENCE↗

Local thermal actuation of material surfaces via micro- and nanowire heating for the prevention of cellular attachment and biological fouling

The invention relates in various embodiments to a composite useful as e.g. a medical implant device, and a method of treating fouling, including biofouling as may occur on an implant. The composite comprises a matrix phase and a patterned phase that comprises an energetically activatable wire intermixed with the matrix phase, the wire when energetically activated, which includes thermal activation, causes modification of at least a portion of the matrix phase to treat fouling that might otherwise occur. The method of treating biofouling may be practiced on a patent while the medical implant of the invention is in situ.

36 MATERIALS SCIENCE↗

Characterization and Well Remediation Strategies for Improved Long-term Pump and Treat System Injection Well Performance - 17272

In June of 2012 the CH2M Hill Plateau Remediation Company completed construction of a 2,500 gallon-per-minute (gpm) pump and treat (P and T) system designed to remove technetium-99, uranium, carbon tetrachloride, trichloroethene, nitrate, and total and hexavalent chromium from incoming groundwater. The entire pump and treat system consists of the following primary components: 1) extraction wells (20+); 2) a radionuclide removal facility; 3) a biological system; 4) sludge processing; 5) vapor processing; and 6) injection wells. Overall efficiency of the 200 West P and T has been adversely impacted due to fouling in vertical injection wells where treated water is being reinjected into the subsurface. Fouling of the wells is thought to be caused by bacteria producing extracellular polymeric substances (EPS), as well as high manganese and iron in the biofilm. Due to decreased specific injectivity, all injection wells are on a maintenance schedule requiring rehabilitation. During rehabilitation, the wells are out of service affecting the overall capacity of the P and T, plus the rehabilitation process adds hundreds of thousands of dollars of cost to operate the P and T each year. Chemical and biological foulants may be coming from the P and T or are already present in the subsurface and active pumping has stimulated growth of the microbes present. Chemical and microbiological characterization efforts are in progress for the biological plant and injection well system to determine causative agents in the biofouling. P and T effluent tank samples, injection well distribution tanks, bailed samples from the fouled well, and post-rehabilitation samples were analyzed. Chemical constituents analyzed include, sulfate, phosphorus, chemical oxygen demand, total organic carbon, and iron. Microbial characterization included total heterotrophs, anaerobic heterotrophs, nitrate reducing bacteria, iron reducing bacteria and sulfate reducing bacteria. Molecular biological tools employed included 16S rRNA meta-genomes, and functional gene analysis using qPCR. Chemical analysis of the P and T effluent and injection well tanks showed the presence of ∼6.5 mg/L nitrate, 96 mg/L sulfate and phosphorus levels below 1 mg/L. Bailed samples from the injection well showed similar concentrations for each chemical, but following cleaning, TOC, total iron, manganese and other constituents were higher than prior to cleaning. These data show that bacterial nutrients and metals that may precipitate are present in the well water and are likely the causative agent in the biofouling. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Challenges and Solutions in Operation and Lay-Up of the Modular Caustic- Side Solvent Extraction Unit - 20078

The Modular Caustic-Side Solvent Extraction (CSSX) Unit (MCU) was designed and constructed to provide interim salt waste processing so that the Liquid Waste Disposition Program (LWDP) could continue waste removal and tank closure until start-up of the Salt Waste Processing Facility (SWPF). MCU processes Clarified Salt Solution (CSS), or salt solution (SS) that has undergone actinide removal/filtration, to produce two waste streams: the cesium laden Strip Effluent (SE), which is incorporated into glass at the Defense Waste Processing Facility (DWPF), and the cesium depleted Decontaminated SS (DSS), which is incorporated into grout at the Saltstone Production Facility (SPF). MCU completed start-up in 2008 with an initial operating life of 3 years and design life of 5 years. Prior to reaching the end of the design life, multiple critical components were upgraded and/or replaced to mitigate risks associated with any delays in SWPF start-up. During the remainder of operation (until June 2019), MCU was challenged to maximize processing with minimal additional modifications to repair/improve aging infrastructure, while maintaining low levels of risk to workers and the environment. Notable challenges during the extended operating life of the facility involved both mechanical and operational issues. Two of the most significant issues were the increased frequency of Process Vessel Ventilation (PVV) High Efficiency Particulate Air (HEPA) filter change-outs and the biofouling of the SE coalescer (SEC). The major impacts of both issues were that replacement of these components 1) resulted in high exposure to workers, and 2) required substantial downtime, thus hindering achievement of processing goals. PVV HEPA filter replacements are required based on dose rate and differential pressure (dP) limits. After introducing a higher-curie feed to MCU, the operating time between change outs was reduced by approximately half. SEC replacements are required based on dP limits. After restarting from an extended outage, the operating life of the SEC was significantly reduced by more than half due to biofouling. As a result of extensive troubleshooting and process improvements, the facility was able to recover performance and extend the operating life of the PVV HEPA filters and the SEC media. Through troubleshooting both of these issues, the facility was also able to learn from prior experience and adapt in order to minimize down time and maintain throughput. Although the facility took advantage of short periods of downtime to perform nonintrusive troubleshooting and minor corrective/preventative maintenance activities, longer outages were periodically required for corrective maintenance involving process cell entry. During these outages, remote tools and specialized shield plates were employed to minimize dose to workers. Mock-ups of non-routine maintenance activities were critical to early identification of potential issues and improvements, which shortened outage duration. Consistent with the facility's operational strategy, evolutions needed for MCU layup were identified and sequenced to ensure safe conditions within the facility, meet pre-defined criteria for lay-up configuration, and protect workers, while minimizing the impact to SWPF integration. De-inventory and flushing of process areas was prioritized so that the total residual inventory was reduced as efficiently as possible. This paper discusses lessons learned and best practices from troubleshooting unique issues, performing complex maintenance activities, and implementing a layup strategy that best supports the overall system mission. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Uranium from Seawater Cost Analysis: Recent Updates

While it is not meant to be a direct competitor with conventionally mined uranium, seawater uranium has significant potential to sway policy makers and the public toward the long term viability of nuclear power. Given the large mass of uranium contained within the ocean and its continual replenishment by freshwater run-off and the ocean floor, seawater uranium can be considered for all practical purposes a renewable resource. In addition to this assurance of supply security placing nuclear power on equal footing with other renewable energy generation technologies, seawater uranium removes a key uncertainty by establishing a cost ceiling on uranium based fuels. Given the evolving nature of this technology, this paper aims to provide an update of the economic model to reflect recent progress. This analysis will reference a passive collection system currently under development by Oak Ridge and Pacific Northwest National Labs. This system consists of a polymer modified to contain amidoxime functional groups, a ligand with high uranium affinity. The adsorbing material is then braided into long segments so it may be moored to the bottom of the ocean where it passively collects uranium for a period on the order of weeks to months. Upon completion of its soaking campaign adsorbent is winched to the surface by work boats so the uranium may be eluted off the braids. After a chemical rinse the braids may then be redeployed for another soaking campaign and uranium elution. The adsorbent can be redeployed as many times as is economically feasible, which is a function of the degradation the material suffers upon each reuse. Noteworthy experimental progress has tightened the gap separating estimates of the optimistic and pessimistic case uranium production cost relative to the most recent analysis. It has been demonstrated before that significant uncertainty in adsorbent performance, and thus recovery cost, arises primarily from variability in adsorbent degradation upon reuse and the effects of marine biofouling on uptake. While the underlying recovery mechanism remains, significant changes have been made regarding the method of adsorbent synthesis, propagating to improvements in adsorbent durability. Additionally, further experimentation regarding the area of marine biofouling has tightened the range of expected adsorbent performance when placed in true marine conditions.

07 ISOTOPE AND RADIATION SOURCES↗

Carbon nanospikes have improved sensitivity and antifouling properties for adenosine, hydrogen peroxide, and histamine

Carbon nanospikes (CNSs) are a new nanomaterial that has enhanced surface roughness and surface oxide concentration, increasing the sensitivity for dopamine detection. However, CNS-modified electrodes (CNSMEs) have not been characterized for other neurochemicals, particularly those with higher oxidation potentials. The purpose of this study was to evaluate CNSMEs for the detection of adenosine, hydrogen peroxide (H 2 O 2 ), and histamine. The sensitivity increased with CNSs, and signals at CNSMEs were about 3.3 times higher than CFMEs. Normalizing for surface area differences using background currents, CNSMEs show an increased signal of 4.8 times for adenosine, 1.5 times for H 2 O 2 , and 2 times for histamine. CNSMEs promoted the formation of secondary products for adenosine and histamine, which enables differentiation from other analytes with similar oxidation potentials. Furthermore, CNSs also selectively enhance the sensitivity for adenosine and histamine compared to H 2 O 2 . A scan rate test reveals that adenosine is more adsorption-controlled at CNS electrodes than CFMEs. CNSMEs are antifouling for histamine, with less fouling because the polymers formed after histamine electrooxidation do not adsorb due to an elevated number of edge planes. CNSMEs were useful for detecting each analyte applied in brain slices. Because of the hydrophilic surface compared to CFMEs, CNSMEs also have reduced biofouling when used in tissue. Therefore, CNSMEs are useful for tissue measurements of adenosine, hydrogen peroxide, and histamine with high selectivity and low fouling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Use of diffusive gradients in thin films (DGT) to measure potentially bioavailable metals in southeastern USA blackwater streams

Here, we used diffusive gradients in thin films (DGT) to measure potentially bioavailable metals in coastal plain streams in the southeastern USA that exhibited strong to moderate blackwater characteristics. Metals were partitioned into particulate metals, DGT-inert metals (i.e., colloidal and refractory organic complexes not accumulated by DGT), and DGT-labile metals (i.e., free metal ions, small inorganic complexes, and labile organic complexes). We also examined the influence of different DGT deployment times using data collected from the field and a follow-up laboratory study. The DGT-measured fraction of dissolved metals in the streams was 15% for Cd, 21% for Zn, 33% for Cu, 37% for Pb, and 98% for Mn. Metals bound to particulates predominated only for Pb. Most of the Cd, Pb, Zn, and Cu were associated with colloids, refractory organic complexes, or particles. Relatively small amounts were in free ion or labile complexes likely to be bioavailable through respiratory surfaces. Modeled concentrations of free and inorganically bound Cu and Pb were lower than the DGT fraction indicating that DGT accumulated some organically bound Cu and Pb that might not have been bioavailable. DGT-exposure times in excess of 5 days may have contributed to the accumulation of partly labile organic–metal complexes and were associated with substantial biofouling that caused metal uptake by DGT to depart from linearity.

54 ENVIRONMENTAL SCIENCES↗

Microbial diversity analysis of two full-scale seawater desalination treatment trains provides insights into detrimental biofilm formation

Detrimental biofilms on RO membranes remain a crucial challenge for seawater desalination. Comparative analysis of 16S rRNA gene amplicon sequencing data revealed differences and commonalities of biofilm communities associated with unit operations in the two largest seawater desalination facilities in the U.S., the Claude "Bud" Lewis Carlsbad Desalination Plant and the Tampa Bay Seater Desalination facility. At both plants, feedwater collected at a single time point was a poor indicator of the RO membrane communities, which showed far greater taxa diversity. The analysis of prefilter cartridges from the Carlsbad plant revealed similarly high taxon diversity as the RO module biofilms, with relevant differences. Algal sequences were enriched on the prefilter cartridges as were sequences representing Bdellovibrionota, which are predatory bacteria. Sequences representing opportunistic Gammaproteobacteria (i.e., Shewanella, Woesia) were present in significantly higher relative abundance on the RO membranes than in the prefilter cartridges, suggesting growth of certain taxa in the RO modules. Untargeted metabolomics distinguished intra- and inter-desalination plant biofilm samples, highlighting the potential value of this tool for biofilm monitoring. These findings underscore the value of omics tools for effective microbial monitoring, to understand biofouling dynamics within RO desalination plants, and to provide insight for the development of ecologically-informed biofilm control measures.

59 BASIC BIOLOGICAL SCIENCES↗

Moisture-driven CO 2 direct air capture and delivery for cultivating cyanobacteria

This study demonstrates a low-energy system that passively captures CO₂ from ambient air using reusable solid sorbents and delivers it directly into alkaline cultivation media to support the growth of cyanobacteria, from laboratory flasks to outdoor raceway ponds. While long-term operation revealed challenges including biofouling and sorbent degradation, the results suggest that with improved sorbent durability, this approach could provide a scalable source of atmospheric carbon for producing sustainable fuels, proteins, natural colorants, and other bioproducts.

09 BIOMASS FUELS↗

Antifouling strategies for protecting bioelectronic devices

Bioelectronic devices are playing an increasingly important role in many areas of our lives. They power a significant portion of medical diagnostics and are becoming more and more important for delivery of therapeutics and monitoring of chronic symptoms. However, surface fouling phenomena, and especially biofouling in complex biological fluids, restricts the performance of these devices and severely reduces their useful lifespan. In this Research Update, we discuss the main principles and strategies that researchers use to prevent fouling and minimize or remove the foulants from bioelectronic device surfaces. We also survey a variety of antifouling approaches that can enhance device performance.

36 MATERIALS SCIENCE↗

An improved method for quantitatively measuring antifouling coating performance using a mussel single thread tensile adhesion test

Surface biofouling reduces the efficiency and lifespan of equipment across many industries. The development of high-performance antifouling surfaces, such as foul release coatings, benefits from test methods that can quickly identify superior antifouling surfaces in the laboratory during material development. Existing test methods poorly discriminate between different foul release coatings. Here is presented a method to assess the ability of surfaces to resist mussel adhesion using a quantitative, controlled single thread adhesion test (STAT) method, allowing for meaningful comparisons between low adhesion foul release surfaces. This method provides greater accuracy and finer resolution than push-based mussel shear adhesion methods without the difficulties associated with mussel size, thread attachment angle, or harming the mussels. The single thread tensile method is demonstrated on a variety of standard and high-performance coatings, and it is shown that the method detects differentiation between commercial foul release coatings that could not be resolved using other methods.

42 ENGINEERING↗