Search NASA⌕ Search

SEARCH · Search NASA

Results for “Biological Effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Comparison of the biological effects of {sup 18}F at different intracellular levels

Highlights: • We estimated the inductions of DNA DSB in cell treated with {sup 18}F-FDG. • We found that inductions of DNA DSB are dependent on accumulation of {sup 18}F in cell. • Accumulation of {sup 18}F in cell may be indispensable for risk estimation of PET. - Abstract: We herein examined the biological effects of cells treated with {sup 18}F labeled drugs for positron emission tomography (PET). The relationship between the intracellular distribution of {sup 18}F and levels of damaged DNA has yet to be clarified in detail. We used culture cells (Chinese Hamster Ovary cells) treated with two types of {sup 18}F labeled drugs, fluorodeoxyglucose (FDG) and fluorine ion (HF). FDG efficiently accumulated in cells, whereas HF did not. To examine the induction of DNA double strand breaks (DSB), we measured the number of foci for 53BP1 that formed at the site of DNA DSB. The results revealed that although radioactivity levels were the same, the induction of 53BP1 foci was stronger in cells treated with {sup 18}F-FDG than in those treated with {sup 18}F-HF. The clonogenic survival of cells was significantly lower with {sup 18}F-FDG than with {sup 18}F-HF. We concluded that the efficient accumulation of {sup 18}F in cells led to stronger biological effects due to more severe cellular lethality via the induction of DNA DSB.

60 APPLIED LIFE SCIENCES↗

SU-F-T-131: No Increase in Biological Effectiveness Through Collimator Scattered Low Energy Protons

Purpose: To reduce the lateral penumbra of low-energy proton beams, brass collimators are often used in spot-scanning proton therapy (SSPT). This study investigates the increase in biological effectiveness through collimator scattered protons in SSPT. Methods: The SSPT system of the Hokkaido University Hospital Proton Beam Therapy Center, which consists of a scanning nozzle, a 2-cm thick brass collimator, and a 4-cm thick energy absorber, was simulated with our validated Geant4 Monte Carlo code (ver. 9.3). A water phantom was irradiated with proton pencil beams of 76, 110, and 143 MeV. The tested collimator opening areas (COA) were 5×5, 10×10, and 15×15 cm{sup 2}. Comparisons were made among the dose-averaged LET values of protons that hit the collimators (LETDColl), protons that did not hit the collimators (LETDNoColl), and all protons (LETDTotal). X-ray equivalent doses (Deq) were calculated using the linear-quadratic model with LETDNoColl and LETDTotal, and their maximum difference was determined over regions where the physical dose was greater than 10% of the peak dose of 2 Gy. Results: The ratio of the dose contribution of collimator scattered protons to that of all protons, defined as λ, was large at high proton energies and large COAs. The maximum λ value ranged from 3% (76 MeV, 5×5 cm{sup 2}) to 29% (143 MeV, 15×15 cm{sup 2}). Moreover, a large difference between LETDColl and LETDNoColl was only found in regions where λ was below 20% (ΔLETD > 2 keV/µm) and 8% (ΔLETD > 5 keV/µm). Consequently, the maximum difference between LETDNoColl and LETDTotal was as small as 0.8 keV/µm in all simulated voxels, and the difference of Deq reached a maximum of 1.5% that of the peak dose obtained at the water surface with a 76 MeV beam. Conclusion: Although collimator scattered protons have high LET, they only increase the physical dose, not the biological effectiveness.

07 ISOTOPE AND RADIATION SOURCES↗

Temporal Lobe Reactions After Carbon Ion Radiation Therapy: Comparison of Relative Biological Effectiveness–Weighted Tolerance Doses Predicted by Local Effect Models I and IV

Purpose: To compare the relative biological effectiveness (RBE)–weighted tolerance doses for temporal lobe reactions after carbon ion radiation therapy using 2 different versions of the local effect model (LEM I vs LEM IV) for the same patient collective under identical conditions. Methods and Materials: In a previous study, 59 patients were investigated, of whom 10 experienced temporal lobe reactions (TLR) after carbon ion radiation therapy for low-grade skull-base chordoma and chondrosarcoma at Helmholtzzentrum für Schwerionenforschung (GSI) in Darmstadt, Germany in 2002 and 2003. TLR were detected as visible contrast enhancements on T1-weighted MRI images within a median follow-up time of 2.5 years. Although the derived RBE-weighted temporal lobe doses were based on the clinically applied LEM I, we have now recalculated the RBE-weighted dose distributions using LEM IV and derived dose-response curves with Dmax,V-1 cm³ (the RBE-weighted maximum dose in the remaining temporal lobe volume, excluding the volume of 1 cm³ with the highest dose) as an independent dosimetric variable. The resulting RBE-weighted tolerance doses were compared with those of the previous study to assess the clinical impact of LEM IV relative to LEM I. Results: The dose-response curve of LEM IV is shifted toward higher values compared to that of LEM I. The RBE-weighted tolerance dose for a 5% complication probability (TD{sub 5}) increases from 68.8 ± 3.3 to 78.3 ± 4.3 Gy (RBE) for LEM IV as compared to LEM I. Conclusions: LEM IV predicts a clinically significant increase of the RBE-weighted tolerance doses for the temporal lobe as compared to the currently applied LEM I. The limited available photon data do not allow a final conclusion as to whether RBE predictions of LEM I or LEM IV better fit better clinical experience in photon therapy. The decision about a future clinical application of LEM IV therefore requires additional analysis of temporal lobe reactions in a comparable photon-treated collective using the same dosimetric variable as in the present study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Carbon Ion Irradiation of the Rat Spinal Cord: Dependence of the Relative Biological Effectiveness on Linear Energy Transfer

Purpose: To measure the relative biological effectiveness (RBE) of carbon ions in the rat spinal cord as a function of linear energy transfer (LET). Methods and Materials: As an extension of a previous study, the cervical spinal cord of rats was irradiated with single doses of carbon ions at 6 positions of a 6-cm spread-out Bragg peak (16-99 keV/μm). The TD{sub 50} values (dose at 50% complication probability) were determined according to dose-response curves for the development of paresis grade 2 within an observation time of 300 days. The RBEs were calculated using TD{sub 50} for photons of our previous study. Results: Minimum latency time was found to be dose-dependent, but not significantly LET-dependent. The TD{sub 50} values for the onset of paresis grade 2 within 300 days were 19.5 ± 0.4 Gy (16 keV/μm), 18.4 ± 0.4 Gy (21 keV/μm), 17.7 ± 0.3 Gy (36 keV/μm), 16.1 ± 1.2 Gy (45 keV/μm), 14.6 ± 0.5 Gy (66 keV/μm), and 14.8 ± 0.5 Gy (99 keV/μm). The corresponding RBEs increased from 1.26 ± 0.05 (16 keV/μm) up to 1.68 ± 0.08 at 66 keV/μm. Unexpectedly, the RBE at 99 keV/μm was comparable to that at 66 keV/μm. Conclusions: The data suggest a linear relation between RBE and LET at high doses for late effects in the spinal cord. Together with additional data from ongoing fractionated irradiation experiments, these data will provide an extended database to systematically benchmark RBE models for further improvements of carbon ion treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical analysis of the approximate, 3-dimensional, biological effective dose equation in multiphase treatment plans

A multiphase, approximate biological effective dose (BED{sub A}) equation was introduced because most treatment planning systems (TPS) are incapable of calculating the true BED (BED{sub T}). This work investigates the accuracy and precision of the multiphase BED{sub A} relative to the BED{sub T} in clinical cases. Ten patients with head and neck cancer and 10 patients with prostate cancer were studied using their treatment plans from Pinnacle{sup 3} 9.2 (Philips Medical, Fitchburg, WI). The organs at risk (OARs) that were studied are the normal brain, left and right optic nerves, optic chiasm, spinal cord, brainstem, bladder, and rectum. BED{sub A} and BED{sub T} distributions were calculated using MATLAB 2010b (MathWorks, Natick, MA) and analyzed on a voxel basis for percent error, percent error volume histograms (PEVHs), Pearson correlation coefficient, and Bland-Altman analysis. The maximum BED values that were calculated using the BED{sub A} and BED{sub T} methods were also analyzed. BED{sub A} was found to always underestimate BED{sub T}. The accuracy and precision of BED{sub A} distributions varied between the organs: for optic chiasm and brainstem, 50% of the patients had an overall BED{sub A} percent error of A percent error of A percent error of A distributions had maximum errors ranging from 2% to 11%, with the 11% error occurring for bladder. BED{sub A} produced much more accurate maximum BED values with adjacent organs such as normal brain, bladder, and rectum. This study has shown that BED{sub A} can calculate BED distributions with acceptable accuracy under certain circumstances. However, its consistency and accuracy strongly depend on the dose distributions of the different treatment phases. One should be cautious when using BED{sub A}.

61 RADIATION PROTECTION AND DOSIMETRY↗

Systematic review of biological effects of exposure to static electric fields. Part II: Invertebrates and plants

Highlights: • Environmental impacts of static EF were assessed in invertebrate and plant studies. • Invertebrates are able to perceive the presence of static EF near HVDC power lines. • No evidence for adverse effects on physiological functions at HVDC field levels. • Corona-action appears to cause adverse biological effects at very high field levels. • Methodological flaws in all reviewed studies lowered credibility in the results. The construction of high-voltage direct current (HVDC) lines for the long-distance transport of energy is becoming increasingly popular. This has raised public concern about potential environmental impacts of the static electric fields (EF) produced under and near HVDC power lines. As the second part of a comprehensive literature analysis, the aim of this systematic review was to assess the effects of static EF exposure on biological functions in invertebrates and plants and to provide the basis for an environmental impact assessment of such exposures.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Calculation of the biological effective dose for piecewise defined dose-rate fits

An algorithmic solution to the biological effective dose (BED) calculation from the Lea-Catcheside formula for a piecewise defined function is presented. Data from patients treated for metastatic thyroid cancer were used to illustrate the solution. The Lea-Catcheside formula for the G-factor of the BED is integrated numerically using a large number of small trapezoidal fits to each integral. The algorithmically calculated BED is compatible with an analytic calculation for a similarly valued exponentially fitted dose-rate plot and is the only resolution for piecewise defined dose-rate functions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Biological Effectiveness of Accelerated Particles for the Induction of Chromosome Damage Measured in Metaphase and Interphase Human Lymphocytes

Chromosome aberrations were investigated in human lymphocytes after in vitro exposure to 1H-, 3He-, 12C-, 40Ar-, 28Si-, 56Fe-, or 197Au-ion beams, with LET ranging from approximately 0.4-1393 keV/microm in the dose range of 0.075-3 Gy. Dose-response curves for chromosome exchanges, measured at the first mitosis postirradiation using fluorescence in situ hybridization (FISH) with whole-chromosome probes, were fitted with linear or linear-quadratic functions. The relative biological effectiveness (RBE) was estimated from the initial slope of the dose-response curve for chromosomal damage with respect to low- or high-dose-rate gamma rays. Estimates of RBEmax values for mitotic spreads, which ranged from near 0.7 to 11.1 for total exchanges, increased with LET, reaching a maximum at about 150 keV/microm, and decreased with further increase in LET. RBEs for complex aberrations are undefined due to the lack of an initial slope for gamma rays. Additionally, the effect of mitotic delay on RBE values was investigated by measuring chromosome aberrations in interphase after chemically induced premature chromosome condensation (PCC), and values were up to threefold higher than for metaphase analysis.

NASA Discipline Radiation Health↗

SU-E-T-494: Influence of Proton Track-Cell Nucleus Incidence Angle On Relative Biological Effectiveness

Purpose: To explain a Monte Carlo (MC) simulation artifact whereby differences in relative biological effectiveness (RBE) in the induction of initial double strand breaks are observed as a function of the proton track incidence angles in a geometric cell nucleus model. Secondly, to offer an alternative isotropic irradiation procedure to mitigate this effect. Methods: MC tracks of 1 MeV protons were generated in an event-by-event mode. They were overlaid on a cylindrical model of a cell nucleus containing 6×109 nucleotide base pairs. The tracks incidence angle θ with respect to the cell nucleus’s axis was varied in 10 degrees intervals, each time generating one hundred fractions of ∼2 Gy. Strand breaks were scored in the modeled DNA sugar-phosphate groups and further sub-classified into single or double strand breaks (ssbs or dsbs). For each angle, an RBE for the induction of initial dsbs with reference to Co-60 was calculated. Results: Our results show significant angular dependencies of RBE, with maximum values for incidence angles parallel to the nucleus central axis. Further examination shows that the higher cross-sections for the creation of dsbs is due to the preferential alignment of tracks with geometrical sub-parts of the cell nucleus model, especially the nucleosomes containing the sugar-phosphate groups. To alleviate the impact of this simulation artifact, an average RBE was calculated with a procedure based on a weighted sampling of the angular data. Conclusion: This work demonstrates a possible numerical artifact in estimated RBE if the influence of the particle incidence angle is not correctly taken into account. A correction procedure is presented to better conform the simulations to real-life experimental conditions. We would like to acknowledge support from the Fonds de recherche du Quebec Sante (FRQS), from the CREATE Medical Physics Research Training Network grant (number 432290) of NSERC, support from NSERC under grants RGPIN 397711-11 and RGPIN-2014-06475 and support from the CIHR under grants MOP-114910, MOP-136774 and MOP-102550.

60 APPLIED LIFE SCIENCES↗

SU-F-T-682: In-Vivo Simulation of the Relative Biological Effectiveness in Proton Therapy Using a Monte Carlo Method

Purpose: In proton therapy, the relative biological effectiveness (RBE) – compared with conventional photon therapy – is routinely set to 1.1. However, experimental in vitro studies indicate evidence for the variability of the RBE. To clarify the impact on patient treatment, investigation of the RBE in a preclinical case study should be performed. Methods: The Monte Carlo software TOPAS was used to simulate the radiation field of an irradiation setup at the experimental beamline of the proton therapy facility (OncoRay) in Dresden, Germany. Simulations were performed on cone beam CT-data (CBCT) of a xenogeneous mouse with an orthotopic lung carcinoma obtained by an in-house developed small animal image-guided radiotherapy device. A homogeneous physical fraction dose of 1.8Gy was prescribed for the contoured tumor volume. Simulated dose and linear energy transfer distributions were used to estimate RBE values in the mouse based on an RBE model by Wedenberg et al. To characterize radiation sensitivity of normal and tumor tissue, α/β-ratios were taken from the literature for NB1RGB (10.1Gy) and human squamous lung cancer (6.2Gy) cell lines, respectively. Results: Good dose coverage of the target volume was achieved with a spread-out Bragg peak (SOBP). The contra-lateral lung was completely spared from receiving radiation. An increase in RBE towards the distal end of the SOBP from 1.07 to 1.35 and from 1.05 to 1.3 was observed when considering normal tissue and tumor, respectively, with the highest RBE values located distal to the target volume. Conclusion: Modeled RBE values simulated on CBCT for experimental preclinical proton therapy varied with tissue type and depth in a mouse and differed therefore from a constant value of 1.1. Further translational work will include, first, conducting preclinical experiments and, second, analogous RBE studies in patients using experimentally verified simulation settings for our clinically used patient-specific beam conforming technique.

60 APPLIED LIFE SCIENCES↗

Characterization and biological effect of Buenos Aires urban air particles on mice lungs

Exposure to increased levels of ambient air particulate matter (PM) is associated with increased cardiopulmonary morbidity and mortality. Its association with adverse health effects and the still unclear mechanisms of action are of concern worldwide. Our objective was to analyze air PM from downtown Buenos Aires (UAP-BA), and evaluate its biological impact on normal airways. We studied the inflammatory response to intranasal instillation of UAP-BA in a short-term-exposure mouse model. We analyzed UAP-BA morphology by scanning electron microscopy and characterized particle chemical composition by energy dispersive X-ray analysis and capillary gas chromatography. We evaluated lung changes by histomorphometry and histochemical methods. Regarding size, surface area and distribution, UAP-BA proved to be small spherical ultrafine particles: free, in clusters and associated to a matrix. The particles contained polycyclic aromatic hydrocarbons, polychlorinated biphenyls and almost no metal traces. Histologically, UAP-BA induced the recruitment of phagocytes, a reduction in air spaces, an increase in mucous PAS positive cells and weak incomplete elastic fiber network. Our results demonstrate that UAP-BA causes adverse biological effects on the respiratory tract generating inflammation that, in turn, may cause tissue injury or organ dysfunction and may contribute to the pathogenesis of lung diseases.

60 APPLIED LIFE SCIENCES↗

Recent advances, and unresolved issues, in the application of computational modelling to the prediction of the biological effects of nanomaterials

Nanomaterials research is one of the fastest growing contemporary research areas. The unprecedented properties of these materials have meant that they are being incorporated into products very quickly. Regulatory agencies are concerned they cannot assess the potential hazards of these materials adequately, as data on the biological properties of nanomaterials are still relatively limited and expensive to acquire. Computational modelling methods have much to offer in helping understand the mechanisms by which toxicity may occur, and in predicting the likelihood of adverse biological impacts of materials not yet tested experimentally. This paper reviews the progress these methods, particularly those QSAR-based, have made in understanding and predicting potentially adverse biological effects of nanomaterials, and also the limitations and pitfalls of these methods. - Highlights: • Nanomaterials regulators need good information to make good decisions. • Nanomaterials and their interactions with biology are very complex. • Computational methods use existing data to predict properties of new nanomaterials. • Statistical, data driven modelling methods have been successfully applied to this task. • Much more must be learnt before robust toolkits will be widely usable by regulators.

60 APPLIED LIFE SCIENCES↗

SU-E-T-549: Modeling Relative Biological Effectiveness of Protons for Radiation Induced Brain Necrosis

Purpose: To develop a model of the relative biological effectiveness (RBE) of protons as a function of dose and linear energy transfer (LET) for induction of brain necrosis using clinical data. Methods: In this study, treatment planning information was exported from a clinical treatment planning system (TPS) and used to construct a detailed Monte Carlo model of the patient and the beam delivery system. The physical proton dose and LET were computed in each voxel of the patient volume using Monte Carlo particle transport. A follow-up magnetic resonance imaging (MRI) study registered to the treatment planning CT was used to determine the region of the necrosis in the brain volume. Both, the whole brain and the necrosis volumes were segmented from the computed tomography (CT) dataset using the contours drawn by a physician and the corresponding voxels were binned with respect to dose and LET. The brain necrosis probability was computed as a function of dose and LET by dividing the total volume of all necrosis voxels with a given dose and LET with the corresponding total brain volume resulting in a set of NTCP-like curves (probability as a function of dose parameterized by LET). Results: The resulting model shows dependence on both dose and LET indicating the weakness of the constant RBE model for describing the brain toxicity. To the best of our knowledge the constant RBE model is currently used in all clinical applications which may Result in increased rate of brain toxicities in patients treated with protons. Conclusion: Further studies are needed to develop more accurate brain toxicity models for patients treated with protons and other heavy ions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Brain-Specific Relative Biological Effectiveness of Protons Based on Long-term Outcome of Patients With Nasopharyngeal Carcinoma

Uncertainties in relative biological effectiveness (RBE) constitute a major pitfall of the use of protons in clinics. An RBE value of 1.1, which is based on cell culture and animal models, is currently used in clinical proton planning. The purpose of this study was to determine RBE for temporal lobe radiographic changes using long-term follow-up data from patients with nasopharyngeal carcinoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-H-BRA-01: BEST IN PHYSICS (THERAPY): Nano-Dosimetric Kinetic Model for Variable Relative Biological Effectiveness of Proton and Ion Beams

Purpose: Recent clonogenic cell survival and γH2AX studies suggest proton relative biological effectiveness (RBE) may be a non-linear function of linear energy transfer (LET) in the distal edge of the Bragg peak and beyond. We sought to develop a multiscale model to account for non-linear response phenomena to aid in the optimization of intensity-modulated proton therapy. Methods: The model is based on first-principle simulations of proton track structures, including secondary ions, and an analytical derivation of the dependence on particle LET of the linear-quadratic (LQ) model parameters α and β. The derived formulas are an extension of the microdosimetric kinetic (MK) model that captures dissipative track structures and non-Poissonian distribution of DNA damage at the distal edge of the Bragg peak and beyond. Monte Carlo simulations were performed to confirm the non-linear dose-response characteristics arising from the non-Poisson distribution of initial DNA damage. Results: In contrast to low LET segments of the proton depth dose, from the beam entrance to the Bragg peak, strong deviations from non-dissipative track structures and Poisson distribution in the ionization events in the Bragg peak distal edge govern the non-linear cell response and result in the transformation α=(1+c-1 L) α-x+2(c-0 L+c-2 L^2 )(1+c-1 L) β-x and β=(1+c-1 L)^2 β-x. Here L is the charged particle LET, and c-0,c-1, and c-2 are functions of microscopic parameters and can be served as fitting parameters to the cell-survival data. In the low LET limit c-1, and c-2 are negligible hence the linear model proposed and used by Wilkins-Oelfke for the proton treatment planning system can be retrieved. The present model fits well the recent clonogenic survival data measured recently in our group in MDACC. Conclusion: The present hybrid method provides higher accuracy in calculating the RBE-weighted dose in the target and normal tissues.

61 RADIATION PROTECTION AND DOSIMETRY↗