Search NASA⌕ Search

SEARCH · Search NASA

Results for “Biomedical optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The influence of hydrothermal synthesis temperature on the electronic structure and luminescence property of Cr-doped ZnGa 2 O 4 nanoparticles

Cr-doped ZnGa 2 O 4 (CZGO) is a near-infrared-emitting material with long-lasting persistent luminescence. This unique property makes it a great candidate in optical imaging and sensing for various biomedical applications. Nanosized CZGO can be synthesized via a hydrothermal approach, but the reaction temperatures reported in existing literature vary from 120°C to 220°C, approaching the highest temperature allowed for a standard autoclave vessel. The reason for choosing a particular hydrothermal synthesis temperature has rarely been discussed, and it is unclear whether the resulting CZGO possess the same optical properties. This work compares CZGO nanoparticles synthesized at temperatures from the lowest reported 120°C and to as high as 220°C. We find that although all the synthesized CZGO are light emitting, they exhibit different luminescence intensities and respond differently to the change of excitation energy. X-ray absorption fine structure (XAFS) analysis is employed to investigate the local chemical environment around Zn, Ga and Cr, respectively. We found synthesis temperature strongly influences the Ga species formed in these particles. The energy transfer mechanism is further elucidated using X-ray excited optical luminescence (XEOL) in combination with element-specific XAFS. Two energy transfer paths are identified, which explains the different excitation energy dependencies of the observed photoluminescence.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deep Learning and Natural Language Processing for Accelerated Inverse Design of Optical Metamaterials

Optical metamaterial device design has enjoyed a long track of success over the past 50 years leading to the manipulation of light over a wide range of wavelengths spanning the ultraviolet to the far infrared. The manipulation of light over such wavelengths has already led to many technological advancements such as the design of selective radiative absorbers for solar energy, daytime passive cooling using deep space, and optical invisibility cloaks for defense applications. Further disruptive advancements in energy, defense, computing, and biomedical fields could be enabled or enhanced by future optical metamaterial devices. These technologies could lead to increased energy efficiency and hence reduced national primary energy consumption, cheap long duration energy storage, and next generation solid-state heat engines. But historically the methods to invent and develop all of these devices have been time- consuming and based mostly on intuition and iteration. Finding an optimal design can take years.

36 MATERIALS SCIENCE↗

Deep Learning and Natural Language Processing for Accelerated Inverse Design of Optical Metamaterials

Optical metamaterial device design has enjoyed a long track of success over the past 50 years leading to the manipulation of light over a wide range of wavelengths spanning the ultraviolet to the far infrared. The manipulation of light over such wavelengths has already led to many technological advancements such as the design of selective radiative absorbers for solar energy, daytime passive cooling using deep space, and optical invisibility cloaks for defense applications. Further disruptive advancements in energy, defense, computing, and biomedical fields could be enabled or enhanced by future optical metamaterial devices. These technologies could lead to increased energy efficiency and hence reduced national primary energy consumption, cheap long duration energy storage, and next generation solid-state heat engines. But historically the methods to invent and develop all of these devices have been time- consuming and based mostly on intuition and iteration. Finding an optimal design can take years. In this project we developed a machine learning-based algorithm capable of automatically generating device designs to produce desired optical properties, reducing the design cycle life in certain situations to be almost instantaneous.

36 MATERIALS SCIENCE↗

Optical recognition of constructs using hyperspectral imaging and detection (ORCHID)

Abstract Challenges to deep sample imaging have necessitated the development of special techniques such as spatially offset optical spectroscopy to collect signals that have travelled through several layers of tissue. However, these techniques provide only spectral information in one dimension (i.e., depth). Here, we describe a general and practical method, referred to as Optical Recognition of Constructs Using Hyperspectral Imaging and Detection (ORCHID). The sensing strategy integrates (1) the spatial offset detection concept by computationally binning 2D optical data associated with digital offsets based on selected radial pixel distances from the excitation source; (2) hyperspectral imaging using tunable filter; and (3) digital image binding and collation. ORCHID is a versatile modality that is designed to collect optical signals deep inside samples across three spatial (X, Y, Z) as well as spectral dimensions. The ORCHID method is applicable to various optical techniques that exhibit narrow-band structures, from Raman scattering to quantum dot luminescence. Samples containing surface-enhanced Raman scattering (SERS)-active gold nanostar probes and quantum dots embedded in gel were used to show a proof of principle for the ORCHID concept. The resulting hyperspectral data cube is shown to spatially locate target emitting nanoparticle volumes and provide spectral information for in-depth 3D imaging.

47 OTHER INSTRUMENTATION↗

Application of the Pulsed Photoacoustic Spectroscopy in Biomedicine

The use of optical spectroscopy as a diagnostic tool in biomedical applications and research has grown considerably in the last two decades. One of them is the pulsed photoacoustic or optoacoustic, which promises to be one of the most important tools for disease diagnostic studies, because while most spectroscopies exploit the optical nature of the light-tissue interaction, this field of photoacoustics uses optical energy to generate an acoustic wave which propagates in the tissue environment. The acoustic wave propagation is fundamentally related to various tissue properties and an analysis of the wave dynamics can provide insights into these properties. This work presents a review on pulsed photoacoustic spectroscopy of several photoacoustic methods to derive information about tissue and tissue phantoms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical application of bio ceramics

Ceramics are the inorganic crystalline material. These are used in various field such as biomedical, electrical, electronics, aerospace, automotive and optical etc. Bio ceramics are the one of the most active areas of research. Bio ceramics are the ceramics which are biocompatible. The unique properties of bio ceramics make them an attractive option for medical applications and offer some potential advantages over other materials. During the past three decades, a number of major advances have been made in the field of bio ceramics. This review focuses on the use of these materials in variety of clinical scenarios.

36 MATERIALS SCIENCE↗

Direct measurement of the Kirkwood-Rihaczek distribution for the spatial properties of a coherent light beam

We present a direct measurement of the Kirkwood-Rihaczek (KR) distribution for spatial properties of a coherent light beam in terms of position and momentum (angle) coordinates. We employ a two-local oscillator (LO) balanced heterodyne detection (BHD) to simultaneously extract the distribution of the transverse position and momentum of a light beam. The two-LO BHD can measure the KR distribution for any complex wave field (including quantum mechanical wave function) without applying tomography methods (inverse Radon transformation). The transformation of the KR distribution to the Wigner, Glauber-Sudarshan P, and Husimi or Q distributions in spatial coordinates are illustrated through experimental data. The KR distribution can provide the local information of a wave field, which is suitable for studying particle properties of a quantum system. Meanwhile, the Wigner function is suitable for studying wave properties such as interference, and hence provides nonlocal information of the wave field. The method developed here can be used for exploring the spatial quantum state for information processing and optical phase-space imaging for biomedical applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NASA Tech Briefs, August 2004

Topics covered include: Data Relay Board with Protocol for High-Speed, Free-Space Optical Communications; Software and Algorithms for Biomedical Image Data Processing and Visualization; Rapid Chemometric Filtering of Spectral Data; Prioritizing Scientific Data for Transmission; Determining Sizes of Particles in a Flow from DPIV Data; Faster Processing for Inverting GPS Occultation Data; FPGA-Based, Self-Checking, Fault-Tolerant Computers; Ultralow-Power Digital Correlator for Microwave Polarimetry; Grounding Headphones for Protection Against ESD; Lightweight Stacks of Direct Methanol Fuel Cells; Highly Efficient Vector-Inversion Pulse Generators; Estimating Basic Preliminary Design Performances of Aerospace Vehicles; Framework for Development of Object-Oriented Software; Analyzing Spacecraft Telecommunication Systems; Collaborative Planning of Robotic Exploration; Tools for Administration of a UNIX-Based Network; Preparing and Analyzing Iced Airfoils; Evaluating Performance of Components; Fuels Containing Methane of Natural Gas in Solution; Direct Electrolytic Deposition of Mats of MnxOy Nanowires; Bubble Eliminator Based on Centrifugal Flow; Inflatable Emergency Atmospheric-Entry Vehicles; Lightweight Deployable Mirrors with Tensegrity Supports; Centrifugal Adsorption Cartridge System; Ultrasonic Apparatus for Pulverizing Brittle Material; Transplanting Retinal Cells using Bucky Paper for Support; Using an Ultrasonic Instrument to Size Extravascular Bubbles; Coronagraphic Notch Filter for Raman Spectroscopy; On-the-Fly Mapping for Calibrating Directional Antennas; Working Fluids for Increasing Capacities of Heat Pipes; Computationally-Efficient Minimum-Time Aircraft Routes in the Presence of Winds; Liquid-Metal-Fed Pulsed Plasma Thrusters; Personal Radiation Protection System; and Attitude Control for a Solar-Sail Spacecraft.

Source record↗

Phosphazenes 2014

Phosphazene chemistry continues to expand in its breadth and application. This article discusses new research published in 2013 covering mono- and dimeric structures, cyclotriphosphazenes, linear polymers, and the use of phosphazenic structures as ligands on metal centres. Papers report new reactions and structures as well as materials designed for specific applications, such as biomedical, energy storage, flame retardant, and optical, among others. The critical similarity is the phosphazene P-N structure that gives this area of study wide variation. Mirroring the diversity in chemistry are the tools used to probe structure and behaviour. These techniques include Nuclear Magnetic Resonance (NMR) spectrometry, various optical methods, electrochemistry, membrane transport experiments, etc. Furthermore, computational methods, such as Density Functional Theory (DFT), have been used to provide additional insight. This article is organized by structure, beginning with monomeric, dimeric, and non-cyclic phosphazenes first, followed by the cyclic and linear morphologies, with reported potential applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Topology-imprinting in nonlinear metasurfaces

Flat optical components, or metasurfaces, have transformed optical imaging, data storage, information processing, and biomedical applications by providing unprecedented control over light-matter interactions. These nano-engineered structures enable compact, multidimensional manipulation of light’s amplitude, phase, polarization, and wavefront, producing scalar and vector beams with unique properties such as orbital angular momentum and knotted topologies. This flexibility has potential applications in optical communication and imaging, particularly in complex environments such as atmospheric turbulence and undersea scattering. However, designing metasurfaces for shorter wavelengths, such as visible and ultraviolet light, remains challenging due to fabrication limitations and material absorption. Here, we introduce an innovative concept called topology imprinting using judiciously designed all-dielectric nonlinear optical metasurfaces to replicate desired waveforms at fundamental and harmonic frequencies, opening promising avenues for advanced photonic applications.

42 ENGINEERING↗

Photonic crystal fibres in biomedical investigations

The state of the art in the field of design and study of photonic crystal fibres for biomedical applications is considered and some original results recently obtained by the authors are presented. Optical properties of the fibres that offer prospects of their wide application as biological sensors, 'labs-on-a-chip', and facilities of electromagnetic radiation control in a wide range of wavelengths aimed at designing novel biomedical instrumentation are considered (optical technologies in biophysics and medicine)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Functional imaging and assessment of the glucose diffusion rate in epithelial tissues in optical coherence tomography

Functional imaging, monitoring and quantitative description of glucose diffusion in epithelial and underlying stromal tissues in vivo and controlling of the optical properties of tissues are extremely important for many biomedical applications including the development of noninvasive or minimally invasive glucose sensors as well as for therapy and diagnostics of various diseases, such as cancer, diabetic retinopathy, and glaucoma. Recent progress in the development of a noninvasive molecular diffusion biosensor based on optical coherence tomography (OCT) is described. The diffusion of glucose was studied in several epithelial tissues both in vitro and in vivo. Because OCT provides depth-resolved imaging of tissues with high in-depth resolution, the glucose diffusion is described not only as a function of time but also as a function of depth. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

60 APPLIED LIFE SCIENCES↗

Generation, transport, and detection of linear accelerator based femtosecond-terahertz pulses

The generation and detection of intense terahertz (THz) radiation has drawn a great attention recently. The dramatically enhanced energy and peak electric field of the coherent THz radiation can be generated by coherent superposition of radiated fields emitted by ultrafast electron bunches. The femtosecond (fs)-THz beamline construction at the Pohang Accelerator Laboratory (PAL) was completed in the end of 2009. The fs-THz beamline at PAL can supply ultrafast and intense fs-THz radiation from a 75 MeV linear accelerator. The radiation is expected to have frequency up to 3 THz ({approx}100 cm{sup -1}) and the pulse width of <200 fs with pulse energy up to 10 {mu}J. This intense THz source has great potential for applications in nonlinear optical phenomena and fields such asmaterial science, biomedical science, chemistry, and physics, etc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method for Impeding Degradation of Porous Silicon Structures

This invention relates to surface modification of porosified silicon (pSi) structures with poly(alkylene) glycols for the purpose of controlled degradation of the silicon matrix and tailored release of encapsulated substances for biomedical applications. The pSi structures are currently used in diverse biomedical applications including bio-molecular screening, optical bio-sensoring, and drug delivery by means of injectable/orally administered carriers and implantable devices. The size of the pores and the surface chemistry of the pSi structure can be controlled during the microfabrication process and thereafter. A fine regulation of the degradation kinetics of mesoporous silicon structures is of fundamental importance. Polyethylene glycols (PEGs) represent the major category of surface modifying agents used in classical drug delivery systems and in pharmaceutical dosage forms. PEGylation enables avoidance of RES uptake, thus prolonging circulation time of intravenously injectable nanovectors. PEG molecules demonstrate little toxicity and immunogenicity, and are cleared from the body through the urine (molecular weight, MW less than 30 kDa) or in the feces (MW greater than 30kDa). The invention focuses on the possibility of finely tuning the degradation kinetics of the pSi nanovectors and other structures through surface conjugation of PEGs with various backbone lengths/MWs. To prove the concept, pSi nanovectors were covalently conjugated to seven PEGs with MW from 245 to 5,000 Da and their degradation kinetics in physiologically relevant media (phosphate buffer saline, PBS pH7.4, and fetal bovine serum) was assessed by the elemental analysis of the Si using inductive coupled plasma atomic emission spectroscopy (ICP-AES). The conjugation of the PEG with lowest MW to the nanovectors surface did not induce any change in the degradation kinetics in serum, but inhibited degradation and consequently the release of orthosilicic acid into buffer. When PEGs with the longer chains were evaluated, Si mass loss from the nanovectors was slowed down, and the PEGylated structures were almost fully degraded within 18 24 hours in serum and within 48 hours in PBS. The most dramatic effect was observed for high MW PEGs 3,400 and 5,000 Da, which prominently inhibited the degradation of the systems, with complete degradation achieved only after four days. For these PEGs, during the early stages of the degradation, there was a lag period of little or no Si mass loss from the nanovector. The obtained profiles were in agreement with the erosion of the nanovector surface as observed by scanning electron microscopy.

Vilentchouk, Biana Godin↗

A New Pivoting and Iterative Text Detection Algorithm for Biomedical Images

There is interest to expand the reach of literature mining to include the analysis of biomedical images, which often contain a paper's key findings. Examples include recent studies that use Optical Character Recognition (OCR) to extract image text, which is used to boost biomedical image retrieval and classification. Such studies rely on the robust identification of text elements in biomedical images, which is a non-trivial task. In this work, we introduce a new text detection algorithm for biomedical images based on iterative projection histograms. We study the effectiveness of our algorithm by evaluating the performance on a set of manually labeled random biomedical images, and compare the performance against other state-of-the-art text detection algorithms. We demonstrate that our projection histogram-based text detection approach is well suited for text detection in biomedical images, and that the iterative application of the algorithm boosts performance to an F score of .60. We provide a C++ implementation of our algorithm freely available for academic use.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-00: Session in Memory of Robert J. Shalek: High Resolution Dosimetry from 2D to 3D to Real-Time 3D

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

Empirical electro-optical and x-ray performance evaluation of CMOS active pixels sensor for low dose, high resolution x-ray medical imaging

Monolithic complementary metal oxide semiconductor (CMOS) active pixel sensors with high performance have gained attention in the last few years in many scientific and space applications. In order to evaluate the increasing capabilities of this technology, in particular where low dose high resolution x-ray medical imaging is required, critical electro-optical and physical x-ray performance evaluation was determined. The electro-optical performance includes read noise, full well capacity, interacting quantum efficiency, and pixels cross talk. The x-ray performance, including x-ray sensitivity, modulation transfer function, noise power spectrum, and detection quantum efficiency, has been evaluated in the mammographic energy range. The sensor is a 525x525 standard three transistor CMOS active pixel sensor array with more than 75% fill factor and 25x25 {mu}m pixel pitch. Reading at 10 f/s, it is found that the sensor has 114 electrons total additive noise, 10{sup 5} electrons full well capacity with shot noise limited operation, and 34% interacting quantum efficiency at 530 nm. Two different structured CsI:Tl phosphors with thickness 95 and 115 {mu}m, respectively, have been optically coupled via a fiber optic plate to the array resulting in two different system configurations. The sensitivity of the two different system configurations was 43 and 47 electrons per x-ray incident on the sensor. The MTF at 10% of the two different system configurations was 9.5 and 9 cycles/mm with detective quantum efficiency of 0.45 and 0.48, respectively, close to zero frequency at {approx}0.44 {mu}C/kg (1.72 mR) detector entrance exposure. The detector was quantum limited at low spatial frequencies and its performance was comparable with high resolution a:Si and charge coupled device based x-ray imagers. The detector also demonstrates almost an order of magnitude lower noise than active matrix flat panel imagers. The results suggest that CMOS active pixel sensors when coupled to structured CsI:Tl can be used for conventional and advanced digital mammography due to their low noise, high resolution performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detecting and Tracking Nonfluorescent Nanoparticles Probes in Live Cells

Precisely imaging and tracking dynamic biological processes in live cells are crucial for both fundamental research in life sciences and biomedical applications. Nonfluorescent nanoparticles are emerging as important optical probes in live-cell imaging because of their excellent photostability, large optical cross sections, and low cytotoxicity. Here, we provide a review of recent development in optical imaging of nonfluorescent nanoparticle probes and their applications in dynamic tracking and biosensing in live cells. A brief discussion on cytotoxicity of nanoparticle probes is also provided.

36 MATERIALS SCIENCE↗