Search NASA⌕ Search

SEARCH · Search NASA

Results for “Boiling instabilities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

65 records · Page 4

Throttling Characteristics of the RL10 Derivative Common Extensible Cryogenic Engine -- Demo 1.6 and 1.7 Test Results

The Common Extensible Cryogenic Engine (CECE) is a deep throttling cryogenic Lunar Module Descent Engine (LMDE) technology development demonstrator based on the Pratt & Whitney Rocketdyne (PWR) RL10 engine. Previous testing on this engine occurred during 2006 as Demo 1.0, then Demo 1.5 in 2007, Demo 1.6 in 2008 and finally Demo 1.7 in 2010. A review of Demo 1.0, 1.5, and preliminary results of 1.6 were reported in previous JANNAF papers. Demo 1.6 was tested at the PWR E-6 test facility in November 2008. The primary goal of this series was to mitigate low frequency combustion instability observed at low power levels. To mitigate the chug, the Demo 1.6 injector was modified from the previous configurations to include an approximately 0.050 inch thick teflon-type spray-on insulation to reduce heat transfer to the LOX manifold, which was believed to be a significant contributor to the low power instability. In addition, gaseous helium injection into the LOX manifold was used as a means to stabilize the system. Also explored in this test series was mitigation for a low power 1 Hz fuel system oscillation caused by sub-critical hydrogen boiling in the chamber cooling jacket. Reduced area gas venturis were utilized to avoid the 1 Hz fuel-size oscillation by keeping the cooling jacket supercritical down to lower engine power levels. Demo 1.7 began testing in March 2010. Its primary objectives were to demonstrate closed loop control capability on mixture ratio and chamber pressure, start to lower power levels and increased throttling ramp rates. Secondary test objectives that are discussed include multiple engine starts, higher mixture ratio excursions and additional time at low power level. While the complete test series and data reduction is not yet complete for Demo 1.7, an overview and up-to-date status is provided.

Devine, Matthew K.↗

Thermal Acoustic Oscillation: Causes, Detection, Analysis, and Prevention

Thermal Acoustic Oscillations (TAO) can occur in cryogenic systems and produce significant sources of heat. This source of heat can increase the boil off rate of cryogenic propellants in spacecraft storage tanks and reduce mission life. This paper discusses the causes of TAO, how it can be detected, what analyses can be done to predict it, and how to prevent it from occurring.The paper provides practical insight into what can aggravate instability, practical methods for mitigation, and when TAO does not occur. A real life example of a cryogenic system with an unexpected heat source is discussed, along with how TAO was confirmed and eliminated.

Cryogenics↗

Dryout and Rewetting in the Pool Boiling Experiment Flown on STS-72 (PBE-2 B) and STS-77 (PBE-2 A)

Experiments were conducted in the microgravity of space in which a pool of liquid (R-113), initially at a precisely defined pressure and temperature, is subjected to a step imposed heat flux from a semi-transparent thin-film heater forming part of one wall of the container such that boiling is initiated and maintained for a defined period of time at a constant pressure level. A total of nine tests were conducted at three levels of heat flux and three levels of subcooling in each of the two space experiments in a GAS canister on the STS-77, -72, respectively. Three (3) modes of propagation of boiling across the heater surface and subsequent vapor bubble growths were observed, in addition to the two (2) modes observed in the previous microgravity pool boiling space flights on STS-47, -57, and -60. Of particular interest were the extremely dynamic or "explosive" growths, which were determined to be the consequence of the large increase in the liquid-vapor interface area associated with the appearance of a corrugated or rough interface. Predictions of circumstances for its onset have been carried out. Assumptions were necessary regarding the character of disturbances necessary for the instabilities to grow. Also, a new vapor bubble phenomena was observed in which small vapor bubbles migrated toward a larger bubble, eventually coalescing with this larger bubble. The heat transfer was enhanced approximately 30% as a result of these migrating bubbles, which is believed to be a vapor bubble manifestation of Marangoni convection and/or molecular momentum effects, sometimes referred to as vapor recoil. The circumstances of heat flux and liquid subcooling necessary to produce heater surface dryout for an initially stagnant liquid subjected to an imposed heat flux have been more closely identified.

Merte, Herman, Jr.↗

Fuel property evaluation of unique fatty acid methyl esters containing β-hydroxy esters from engineered microorganisms

Unique fatty acid methyl esters (FAME) containing ..beta..-hydroxy esters were produced using an engineered microorganism by glucose fermentation. This study investigated the properties of the unique FAME mixture both neat and in blends with conventional diesel, as well as properties of ..beta..-hydroxy esters. The unique FAME blend contained relatively shorter-chain FAME (average fatty acid chain carbon number 14.6) with 58 % monounsaturated fatty acids and 9 % saturated and monounsaturated ..beta..-hydroxy acid chains. The unique FAME had significantly lower distillation T90 (321 °C versus 352 °C) and higher cetane number (56.7 versus 52) compared to soy biodiesel. Cloud points were within method repeatability. Unexpectedly (because of the lack of methylene-interrupted double bonds), the unique FAME had low oxidation stability (1.5 h) as determined by Rancimat induction period. Stability could be improved through addition of commonly used antioxidants. We speculate that monounsaturated ..beta..-hydroxy FAME may be the source of this instability. Blends with conventional diesel up to 50 vol% showed similar kinematic viscosity (within method repeatability) as blends of conventional FAME. The unique FAME had no effect on distillation T90 even at the 80% blend level. A 30 vol% blend into conventional diesel had a Rancimat induction period of only 2 h, very nearly the same as the neat unique FAME sample. The addition of antioxidants produced blends of acceptable stability. Based on an assessment of the properties of individual ..beta..-hydroxy FAME molecules, they have higher boiling point, higher cloud point, lower cetane number, and potentially lower storage stability than analogous FAME not having the ..beta..-hydroxy group. Removing them from the fuel product in the production process may result in a biodiesel product with superior properties to what is on the market today.

09 BIOMASS FUELS↗

Hydrodynamic instabilities and heat transfer characteristics in the duct flow of a fluid in the supercritical thermodynamic regime

The behavior of fluids at supercritical thermodynamic conditions is inherently complex due to large variations in thermodynamic and transport properties. Recent numerical and experimental investigations illustrate ongoing interest for these fluids, especially supercritical CO 2 and supercritical water, for a variety of applications. For example, supercritical water reactors (SCWR) operate in this extreme condition of high-pressure and temperature, resulting in highly dynamic flow fields and unexpected heat transfer regimes. The potential heat transfer benefits in this regime are directly associated with the extreme variations in thermodynamic and transport properties, which occur at, and above, the critical point. This work characterizes the hydrodynamic instabilities that arise for fluids at supercritical thermodynamic conditions when buoyancy forces are significant. Two specific configurations are considered, a natural convection cavity flow, and a mixed convection, heated, horizontal channel flow. Natural convection flow in a cavity is a classical configuration with expected behavior below the critical point. This configuration aids in characterizing the effect of the variable properties in the supercritical thermodynamic regime. Further, limited studies in the existing literature have been conducted for low-Reynolds and intermediate-Rayleigh numbers, mixed-convection channel flows for supercritical water, which is the focus of the channel flow configuration. To investigate the thermally driven hydrodynamic instabilities in this regime, a high-order fully-implicit numerical method is used. Such strong variations in thermophysical properties (in particular, density) are difficult to simulate and an altogether compressible framework is needed. Therefore, the compressible Navier-Stokes equations are solved without any additional assumptions. The fully implicit, high-order in space and time, reconstructed discontinuous Galerkin method as implemented within the multi-physics code called ALE3D (Arbitrary Lagrangian and Eulerian in 2D and 3D), developed at Lawrence Livermore National Laboratory (LLNL), is used. This fully implicit, L-stable method accurately captures the compressible nature of the ow in the limit of very low Mach number. It has been widely accepted that above the critical point, only one phase is observed. However, recent research has indicated the existence of the distinct gas-like and liquid-like regions separated by the Widom line, the locus of the maxima of the specific heat. Along the Widom line, density decreases 6-fold, viscosity drops by a factor of 2, while specific heat spikes by an order of magnitude. These variations, specifically in density and viscosity, produce a thick pseudo-interface and flow dynamics behavior akin to film boiling. A pseudo-film at the heated wall of the cavity and the horizontal channel is observed where buoyancy forces induce mixing through the specific configurations. Further the local Rayleigh and Richardson numbers provide maps of the flow field and the buoyancy forces driving the microscopic mixing. In the first chapter, I describe a background of supercritical fluid and the various applications. The second chapter focuses on the mathematical model and numerical method used for simulations, where a description of the equation of state for supercritical water is described. The third chapter focuses on the natural convection cavity with a heated bottom wall. In this cavity a gas-like and a liquid-like flow within the supercritical thermodynamic regime are observed. The fourth chapter focuses on a forced convection, horizontal channel, distinguishing between the gas-like, liquid-like, and mixed flow regimes. Mixed convection flow, with the addition of gravitational forces in the horizontal channel show the influence of variable properties on the hydrodynamic development, heat transfer, and rising instabilities. The last chapter of this research focuses on characterizing the unstable hydrodynamics through time-averaging processes and analysis of the movement of energy through the developing plumes.

42 ENGINEERING↗

High-speed imaging of transition from fluid breakup to phase explosion in electric explosion of tungsten wires in air

High-speed visible imaging of sub-microsecond electric explosion of wires at the low specific energy deposition threshold reveals three distinct modes of wire failure as capacitor charge voltage and energy deposition are increased. For 100 micron diameter gold-plated tungsten wires of 2 cm length, deposited energies of 1.9 eV/atom produces a liquid column that undergoes hydrodynamic breakup into droplets with radii of order of wire diameter on timescales of 200 μs. Instability growth, column breakup, and droplet coalescence follow classic Rayleigh-Plateau predictions for instability of viscous fluid column. Above 3.2 eV/atom of deposited energy, wires are seen to abruptly transition to an expanding mixture of micron scale liquid-droplets and vapor within one frame (less than 3.33 μs), which has been termed ‘phase explosion’ in literature. Between these two limits, at 2.5 eV/atom of deposited energy, wire radius is unchanged for the first 10 μs before the onset of a rapid expansion and disintegration that resembles homogenous nucleation of mechanically unstable bubbles. Here, thermodynamic calculations are presented that separate cases by temperature obtained during heating: below boiling point, near boiling point, and exceeding boiling point.

42 ENGINEERING↗

Shuttle propellant loading instrumenation development

A continuous capacitance sensor was developed and an analog signal conditioner was evaluated to demonstrate the acceptability of these items for use in the space shuttle propellant loading system. An existing basic sensor concept was redesigned to provide capability for cryogenic operation, to improve performance, and to minimize production costs. Sensor development verification consisted of evaluation of sensor linearity, cryogenic performance, and stability during vibration. The signal conditioner evaluation consisted mainly of establishing the effects of the variations in temperature and cable parameters and evaluating the stability. A sensor linearity of 0.04 in. was achieved over most of the sensor length. The sensor instability caused by vibration was 0.04 percent. The cryogenic performance data show a maximum instability of 0.19 percent at liquid hydrogen temperature; a theoretical calibration can be computed a within 1 percent. The signal conditioner evaluation showed that, with temperature compensation, all error sources typically contribute much less than 1 percent. An estimate of the accuracy achievable with the sensor and signal conditioner shows an rss estimate of 0.75 in. for liquid oxygen and 1.02 in. for liquid hydrogen. These are approximately four times better than the shuttle requirements. Comparison of continuous sensor and discrete sensor performance show the continuous sensor to be significantly better when there is surface activity due to sloshing, boiling, or other disturbances.

Hamlet, J.↗

Effect of Inlet Throttling on Thermohydraulic Instability in a Large Scale Waterbased RCCS: A System-Level Analysis with RELAP5-3D

This paper presents results from system -level modeling of a water -based reactor cavity cooling system using RELAP5-3D. The computational model is benchmarked with experimental data from a half -scale RCCS test facility at Argonne National Laboratory. The model prediction is first compared with a two-phase oscillatory baseline experimental case where mixed accuracy is obtained. The model shows reasonable prediction of mass flow rate, pressure, and temperature but significant overprediction of void fraction. The model prediction is then compared with a fault case where the inlet of the risers is gradually reduced using a throttling valve. As the valve is closed, the model is able to predict some major flow phenomena observed in the experiment such as the dampening of oscillations, the reintroduction of oscillations, as well as boiling, flashing, and geysering in the risers. However, the timeline of these events are not well captured by the model. The model is also used to investigate the evolution of flow regime in the chimney. This work highlights that the semiempirical constitutive relations used in RELAP-3D could have a strong influence on the accuracy of the model in two-phase oscillatory flows.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AC loss and contact resistance in REBCO CORC ® , Roebel, and stacked tape cables

Abstract Many high-temperature superconductor (HTS) applications require superconducting cables with high currents while operating in an alternating magnetic field. HTS cables should be composed of numerous superconducting tapes to achieve the required current capacity. Alternating current and magnetic fields cause AC losses in such cables and can provoke conductor instability. AC losses and contact resistances were measured of several cable designs based on commercially available REBCO tapes at the University of Twente. The AC loss was measured under identical conditions for eight REBCO conductors manufactured according to three types of cabling methods—CORC ® (Conductor on Round Core), Roebel, and stacked tape, including a full-size REBCO CICC (cable in conduit conductor). The measurements were done at T = 4.2 K without transport current in a sinusoidal AC magnetic field of 0.4 T amplitude and frequencies from 5 to 55 mHz. The AC loss was measured simultaneously by calibrated gas flow calorimeter utilizing the helium boil-off method and by the magnetization method using pick-up coils. Also, the AC loss of two CORC® conductors and a Roebel cable was measured at 77 K. Each conductor was measured with and without background field of 1 T. The measured AC coupling loss in the CORC ® and Roebel conductors is negligible at 4.2 K for the applied conditions while at 77 K coupling loss was observed for all conductors. The absence of coupling loss at 4.2 K can be explained by shielding of the conductor interior; this is confirmed with measurement and calculation of the penetration field of CORC ® and Roebel cables. The inter-tape contact resistance was measured for CORC ® and stacked tape samples at 4.2 and 77 K. It was demonstrated that a short heat treatment of CORC ® conductor with solder-coated tapes activates tape-to-tape soldering and decreases the contact resistance. The reduction of contact resistance by two orders in magnitude to tens of nΩm is comparable with the interstrand contact resistance in ITER Nb 3 Sn type conductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Photographic Study of Liquid-Oxygen Boiling and Gas Injection in the Injector of a Chugging Rocket Engine

High-speed motion pictures were taken of conditions in the injector liquid-oxygen cavity of an RL-10 rocket engine during throttled engine operation. Photographs were taken during operation of the engine in the chugging region as the helium gas was injected to stabilize combustion, during operation at rated thrust, and during transition into chugging conditions as the gas injection was discontinued. Results of the investigation indicate that, during chugging rocket operation of the RL-10 engine, a high population of fairly large bubbles formed and collapsed within the liquid-oxygen cavity at the same frequency as the chamber pressure oscillations. When gaseous helium was injected into the liquid-oxygen cavity, a fog rapidly spread over the entire field of view, and the system immediately became stable. The injection of gaseous helium at rated conditions produced a very slight increase in engine performance but not enough to produce a net gain in a typical mission payload with the extra equipment needed. The inherent low-frequency system instability associated with the fuel system at low thrust levels was reduced by injecting either gaseous helium or hydrogen. Complete stabilization was achieved in some cases, and a reduction in the severity of the oscillations in others. This was apparently due to the ·anchoring of the phase change front to the location of the gas injection.

Conrad, E. William↗

Planar Strain-Rate-Free Diffusion Flames: Initiation, Properties, and Extinction

An effectively strain-rate-free diffusion flame constitutes the most vigorous laminar combustion of initially unmixed reactive gases. Such a diffusion flame is characterized by a relatively long residence time and by a relatively large characteristic length scale. If such a flame were also planar, providing high symmetry, it would be particularly suitable for experimental and theoretical investigations of key combustion phenomena, such as multicomponent diffusion, chemical kinetics, and soot inception, growth, and oxidation. Unfortunately, a planar strain-rate-free diffusion flame is highly disrupted in earth-gravity (e.g., in a counterflow-diffusion-flame apparatus) because of the very rapid onset (approx. 100 ms) of gravity-induced instability. Accordingly, a specially dedicated apparatus was designed, fabricated, and initially checked out for the examination of a planar strain-rate-free diffusion flame in microgravity. Such a diffusion flame may be formed within a hollowed-out squat container (initially configured as 25 cm x 25 cm x 9 cm), with isothermal, noncatalytic, impervious walls. At test initiation, a thin metallic sheet (approx. 1 mm in thickness) that separates the internal volume into two equal portions, each of dimensions 25 cm x 25 cm x 4.5 cm, is withdrawn, by uniform translation (approx. 50 cm/s) in its own plane, through a tightly fitting slit in one side wall. Thereupon, diluted fuel vapor (initially confined to one half-volume of the container) gains access to diluted oxygen (initially with the same pressure, density, and temperature as the fuel, but initially confined to the other half-volume). After a brief delay (approx. 10 ms), to permit limited but sufficient-for-flammability diffusional interpenetration of fuel vapor and oxidizer, burning is initiated by discharge of a line igniter, located along that side wall from which the trailing edge of the separator withdraws. The ignition spawns a triple-flame propagation across the 25 cm x 25 cm centerplane. When a diffusion flame is emplaced in the centerplane, any subsequent travel, and change in temperature, of that planar diffusion flame may be tracked, along with the effectively spatially uniform but temporally evolving pressure within the container. Eventually, nearly complete depletion of the stoichiometrically deficient reactant, along with heat loss to the container surfaces, effects extinction. These data afford an opportunity to check theoretical models of diffusion and chemical kinetics under conditions ranging from intense burning to flame out, or, alternatively, to evolve simple empirical representations of these phenomena. Thus, the project sought to utilize microgravity testing to elucidate commonly encountered phenomenology, arising in the commonly-encountered mode of combustion (whether related to heating, manufacturing, boiling, and propulsion, or to uncontrolled, free-burning fire in structures and wildland vegetation), of those commonly utilized fuels usually categorized as gaseous fuels (such as hydrogen, natural gas, and propane, which are gaseous under atmospheric conditions).

Fendell, Francis↗