Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALCULATION METHODS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

TH-C-BRD-02: Analytical Modeling and Dose Calculation Method for Asymmetric Proton Pencil Beams

Purpose: A dynamic collimation system (DCS), which consists of two pairs of orthogonal trimmer blades driven by linear motors has been proposed to decrease the lateral penumbra in pencil beam scanning proton therapy. The DCS reduces lateral penumbra by intercepting the proton pencil beam near the lateral boundary of the target in the beam's eye view. The resultant trimmed pencil beams are asymmetric and laterally shifted, and therefore existing pencil beam dose calculation algorithms are not capable of trimmed beam dose calculations. This work develops a method to model and compute dose from trimmed pencil beams when using the DCS. Methods: MCNPX simulations were used to determine the dose distributions expected from various trimmer configurations using the DCS. Using these data, the lateral distribution for individual beamlets was modeled with a 2D asymmetric Gaussian function. The integral depth dose (IDD) of each configuration was also modeled by combining the IDD of an untrimmed pencil beam with a linear correction factor. The convolution of these two terms, along with the Highland approximation to account for lateral growth of the beam along the depth direction, allows a trimmed pencil beam dose distribution to be analytically generated. The algorithm was validated by computing dose for a single energy layer 5×5 cm{sup 2} treatment field, defined by the trimmers, using both the proposed method and MCNPX beamlets. Results: The Gaussian modeled asymmetric lateral profiles along the principal axes match the MCNPX data very well (R{sup 2}≥0.95 at the depth of the Bragg peak). For the 5×5 cm{sup 2} treatment plan created with both the modeled and MCNPX pencil beams, the passing rate of the 3D gamma test was 98% using a standard threshold of 3%/3 mm. Conclusion: An analytical method capable of accurately computing asymmetric pencil beam dose when using the DCS has been developed.

07 ISOTOPE AND RADIATION SOURCES↗

Validation testing of Canberra-Obayashi TruckScan calculation method - 15409

Canberra Industries, Inc. [CI] has designed a new truck monitoring system 'TruckScan' for Interim Storage Facilities [ISF] in Japan. CI and Canberra Japan K.K. [CJKK] have performed validation testing of it with Obayashi Corporation at a temporary storage area in Fukushima prefecture. Decontaminated waste was put into flexible containers called Super Sacks [SS]. The customer desires to quantify the Cs-137 and Cs-134 content of each individual SS, while a group of them are on a truck. This would be done when leaving a temporary waste consolidation area and entering an ISF. The content of SSs is some combination of sand, soil, and vegetation with densities ranging from 0.3 g/cc - 1.6 g/cc. The typical weight of the trucks will be approximately 10 tons, but can vary between 4 and 20 tons. The system must be sensitive enough to detect 100 Bq/kg in 10 - 30 seconds but still have enough dynamic range to measure 1,000,000 Bq/kg material. The system will be operated in an outdoor environment. The desire to separately quantify Cs-137 and Cs-134 favors the use of a spectroscopic system as a solution. The full-scale TruckScan will consist of eight 3x3' NaI detectors, each in a lead shield with a collimated view of the truck. Four detectors are on each side of the truck, at about 1 meter from the truck, spaced at equal distances. These NaI detectors and collimators were calibrated by In Situ Object Counting System (ISOCS) mathematical efficiency calculation tool. The truck stops in-between the two sets of detectors for the short measurement period - typically 15 seconds. The special software performs gamma spectroscopy on each of the 8 spectra, and then decodes the results to determine the activity in each of the 8 [typically] SSs using a Maximum Entropy Analysis Method. Validation testing was done by using SSs filled with known material types and known concentrations of material. The results of the TruckScan assay indicate good accuracy for the wide range of conditions. In spite of the conditions being more severe than normal operations, the combined standard deviation was 20.1% for the 6 detector version and 16.6% for the 8 detector version TruckScan. When the TruckScan results were compared to the known concentrations, there was minimal bias and good correlation [y = 1.0029x, R{sup 2} = 0.914]. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Study on neutronics calculation method of SCWR with annular fuel assembly - 26804

Many Supercritical Water Reactor designs have been proposed all over the world. Annular fuel was employed in SCWR by Xi'an JiaoTong University to achieve lower fuel center temperature and lower cladding surface temperature. Different analysis codes have been developed for these designs. In this article, a neutronics calculation code for SCWR with annular fuel is developed. This code is compared with Monte-Carlo code doing both assembly and core calculation. The results showed that the spectra difference of PWRs and SCWRs is the main reason for assembly calculation errors and conventional assembly homogenization method is not suitable for SCWRs. Thus the group-collapsing and spatial-averaging method were studied to improve the accuracy. The few-group structure which contains 14 energy groups is used. The 'super-assembly' model is employed to consider effect of reflector. The results showed that the accuracy of effective multiplication factor and radial power was improved. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of dose calculation methods for brachytherapy of intraocular tumors

Purpose: To investigate dosimetric differences among several clinical treatment planning systems (TPS) and Monte Carlo (MC) codes for brachytherapy of intraocular tumors using {sup 125}I or {sup 103}Pd plaques, and to evaluate the impact on the prescription dose of the adoption of MC codes and certain versions of a TPS (Plaque Simulator with optional modules). Methods: Three clinical brachytherapy TPS capable of intraocular brachytherapy treatment planning and two MC codes were compared. The TPS investigated were Pinnacle v8.0dp1, BrachyVision v8.1, and Plaque Simulator v5.3.9, all of which use the AAPM TG-43 formalism in water. The Plaque Simulator software can also handle some correction factors from MC simulations. The MC codes used are MCNP5 v1.40 and BrachyDose/EGSnrc. Using these TPS and MC codes, three types of calculations were performed: homogeneous medium with point sources (for the TPS only, using the 1D TG-43 dose calculation formalism); homogeneous medium with line sources (TPS with 2D TG-43 dose calculation formalism and MC codes); and plaque heterogeneity-corrected line sources (Plaque Simulator with modified 2D TG-43 dose calculation formalism and MC codes). Comparisons were made of doses calculated at points-of-interest on the plaque central-axis and at off-axis points of clinical interest within a standardized model of the right eye. Results: For the homogeneous water medium case, agreement was within {approx}2% for the point- and line-source models when comparing between TPS and between TPS and MC codes, respectively. For the heterogeneous medium case, dose differences (as calculated using the MC codes and Plaque Simulator) differ by up to 37% on the central-axis in comparison to the homogeneous water calculations. A prescription dose of 85 Gy at 5 mm depth based on calculations in a homogeneous medium delivers 76 Gy and 67 Gy for specific {sup 125}I and {sup 103}Pd sources, respectively, when accounting for COMS-plaque heterogeneities. For off-axis points-of-interest, dose differences approached factors of 7 and 12 at some positions for {sup 125}I and {sup 103}Pd, respectively. There was good agreement ({approx}3%) among MC codes and Plaque Simulator results when appropriate parameters calculated using MC codes were input into Plaque Simulator. Plaque Simulator and MC users are perhaps at risk of overdosing patients up to 20% if heterogeneity corrections are used and the prescribed dose is not modified appropriately. Conclusions: Agreement within 2% was observed among conventional brachytherapy TPS and MC codes for intraocular brachytherapy dose calculations in a homogeneous water environment. In general, the magnitude of dose errors incurred by ignoring the effect of the plaque backing and Silastic insert (i.e., by using the TG-43 approach) increased with distance from the plaque's central-axis. Considering the presence of material heterogeneities in a typical eye plaque, the best method in this study for dose calculations is a verified MC simulation.

60 APPLIED LIFE SCIENCES↗

New calculation method of neutron kerma coefficients for carbon and oxygen below 30 MeV

On the basis of the statistical theory of a neutron-induced light nucleus reaction, a new kerma coefficient calculation formula, expressed as k{sub {phi}}=NijkE{sub ijk}(E{sub n}){sigma}{sub ijk}(E{sub n}), is developed in this paper. In an analysis of the n+{sup 12}C and n+{sup 16}O reactions below 30 MeV, the average energies E{sub ijk} of emitted particles of all kinds in the laboratory frame are derived in detail for different channels, allowing an exact energy balance. The optical model parameters of neutron and charged particles, which had reproduced very well the outgoing neutron double-differential cross sections in our early works, are used to obtain the cross sections {sigma}{sub ijk}. The calculated partial, elastic recoil, and total kerma coefficients for carbon and oxygen are consistent with existing experimental kerma coefficient data. The elastic cross sections and the first Legendre coefficients of elastic angular distribution derived from EBDF/B-VIIb3 are used in this paper to improve significantly the elastic recoil and total kerma coefficients.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of the Baseline USL Calculation Methods for Loosely-Coupled and Novel Neutronic Systems [Slides]

Current work includes reconstructing 187-group ENDF B/VII.1 covariance matrix for comparison study to 44-group ENDF B/VII.1 matrix to determine how covariance matrix structures affect the USL calculations and investigating the exact domination mechanism of region-wise sensitivities in a loosely-coupled system. Future work will involve seeking to understand how bias distributions change with reactivity and how to calculate propagate distribution error into USL calculations, as well as how cross section perturbation studies can be extended to other types of calculations, such as shielding calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Boundary integral equation method calculations of surface regression effects in flame spreading

A solid-phase conduction problem that is a modified version of one that has been treated previously in the literature and is applicable to flame spreading over a pyrolyzing fuel is solved using a boundary integral equation (BIE) method. Results are compared to surface temperature measurements that can be found in the literature. In addition, the heat conducted through the solid forward of the flame, the heat transfer responsible for sustaining the flame, is also computed in terms of the Peclet number based on a heated layer depth using the BIE method and approximate methods based on asymptotic expansions. Agreement between computed and experimental results is quite good as is agreement between the BIE and the approximate results.

Altenkirch, R. A.↗

Gradient Calculation Methods on Arbitrary Polyhedral Unstructured Meshes for Cell-Centered CFD Solvers

A survey of gradient reconstruction methods for cell-centered data on unstructured meshes is conducted within the scope of accuracy assessment. Formal order of accuracy, as well as error magnitudes for each of the studied methods, are evaluated on a complex mesh of various cell types through consecutive local scaling of an analytical test function. The tests highlighted several gradient operator choices that can consistently achieve 1st order accuracy regardless of cell type and shape. The tests further offered error comparisons for given cell types, leading to the observation that the "ideal" gradient operator choice is not universal. Practical implications of the results are explored via CFD solutions of a 2D inviscid standing vortex, portraying the discretization error properties. A relatively naive, yet largely unexplored, approach of local curvilinear stencil transformation exhibited surprisingly favorable properties

Meshes↗

Generating Older Adult Multimorbidity Trajectories Using Various Comorbidity Indices and Calculation Methods

Older adult multimorbidity trajectories are helpful for understanding the current and future health patterns of aging populations. The construction of multimorbidity trajectories from comorbidity index scores will help inform public health and clinical interventions targeting those individuals that are on unhealthy trajectories. Investigators have used many different techniques when creating multimorbidity trajectories in prior literature, and no standard way has emerged. This study compares and contrasts multimorbidity trajectories constructed from various methods. We describe the difference between aging trajectories constructed with the Charlson Comorbidity Index (CCI) and Elixhauser Comorbidity Index (ECI). We also explore the differences between acute (single year) and chronic (cumulative) derivations of CCI and ECI scores. Social determinants of health can affect disease burden over time; thus, our models include income, race/ethnicity, and sex differences. We use group-based trajectory modeling (GBTM) to estimate multimorbidity trajectories for 86,909 individuals aged 66–75 in 1992 using Medicare claims data collected over the following 21 years. We identify low-chronic disease and high-chronic disease trajectories in all 8 generated trajectory models. Additionally, all 8 models satisfied prior established statistical diagnostic criteria for well-performing GBTM models. Clinicians may use these trajectories to identify patients on an unhealthy path and prompt a possible intervention that may shift the patient to a healthier trajectory.

60 APPLIED LIFE SCIENCES↗