Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALORIMETERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Status of the Mu2e calorimeter readout electronics

The Mu2e experiment [1] at Fermilab will search for the neutrino-less coherent conversion of a muon into an electron in the field of a nucleus. Mu2e detectors comprise a straw tracker, an electromagnetic calorimeter and a veto for cosmic rays. The calorimeter employs 1348 Cesium Iodide crystals readout by silicon photomultipliers and fast front-end and digitization electronics. The front-end electronics consists of two discrete readout circuits (AMP-HV) for each crystal. These provide the amplification, shaping stage and linear regulation of the SiPM bias voltage and monitoring. The SiPM and front-end control electronics is implemented in a battery of mezzanine boards each equipped with an ARM processor that controls a group of 20 Amp-HV circuits distributing the low voltage and the high-voltage. The electronic is hosted in crates located on the external surface of calorimeter disks. The crates also host the waveform digitizer board (DIRAC) that performs digitization of the front end signals and transmit the digitized data to the Mu2e DAQ. Calorimeter electronic is hosted inside the cryostat and must sustain very high radiation and magnetic field so it was necessary to fully qualify it. The system design and quality assurance procedures will be reviewed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CsI(Tl) pulse shape discrimination with the Belle II electromagnetic calorimeter as a novel method to improve particle identification at electron–positron colliders

Here we describe the implementation and performance of CsI(Tl) pulse shape discrimination for the Belle II electromagnetic calorimeter, representing the first application of CsI(Tl) pulse shape discrimination for particle identification at an electron–positron collider. The pulse shape characterization algorithms applied by the Belle II calorimeter are described. Control samples of $γ, μ^+, π^±, K^±$ and $ρ/ \bar{ρ}$ are used to demonstrate the significant insight into the secondary particle composition of calorimeter clusters that is provided by CsI(Tl) pulse shape discrimination. Comparisons with simulation are presented and provide further validation for newly developed CsI(Tl) scintillation response simulation techniques, which when incorporated with GEANT4 simulations allow the particle dependent scintillation response of CsI(Tl) to be modelled. Comparisons between data and simulation also demonstrate that pulse shape discrimination can be a new tool to identify sources of improvement in the simulation of hadronic interactions in materials. The $K^0_L$ efficiency and photon-as-hadron fake-rate of a multivariate classifier that is trained to use pulse shape discrimination is presented and comparisons are made to a shower-shape based approach. CsI(Tl) pulse shape discrimination is shown to reduce the photon-as-hadron fake-rate by over a factor of 3 at photon energies of 0.2 GeV and over a factor 10 at photon energies of 1 GeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Novel X-ray scanning technique for in-situ alignment of photo-detectors in the MEGII calorimeter

Here, we describe and show results of a novel technique to measure with high precision the positions of photodetectors installed in the upgraded liquid xenon calorimeter of the MEG II experiment. The measurement was done by detecting the signal in individual photo-detectors as the front surface of the calorimeter was scanned in axial (Z) and azimuthal (Φ) directions with a precisely controlled, thin, collimated beam of X-rays obtained from a 57 CoX-ray source. The measurements were made when the calorimeter was cold and operational, under which conditions they could not otherwise be made. This technique is used to check for changes in the photodetector positions due to the effects of cooling and thermal cycling of the support structure and to provide a reference between the positions of the operational photodetectors and alignment markers on the cryostat exterior. The use of an essentially monochromatic X-ray source allowed ancillary measurements of photodetector properties, including pulse shape, relative gain, and variation in response over the photodetector surface. Measurement uncertainties below 0.6mm in Z and 0.7 mrad in Φ have been achieved, well within the requirements for the MEG II performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance measurements of the electromagnetic calorimeter and readout electronics system for the DarkQuest experiment

Here, this paper presents performance measurements of a new readout electronics system based on silicon photomultipliers for the PHENIX electromagnetic calorimeter. Installation of the lead-scintillator Shashlik style calorimeter into the SeaQuest/SpinQuest spectrometer has been proposed to broaden the experiment’s dark sector search program, an upgrade known as DarkQuest. The calorimeter and electronics system were subjected to testing and calibration at the Fermilab Test Beam Facility. Detailed studies of the energy response and resolution, as well as particle identification capabilities, were performed. The background rate in the actual experimental environment was also examined. The system is found to be well-suited for a dark sector search program on the Fermilab 120 GeV proton beamline.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The BigBite Calorimeter for the Super Bigbite Spectrometer Program at Jefferson Lab

Here, we report features of the design, construction, installation, and performance of the BigBite Calorimeter (BBCal), a lead-glass electromagnetic calorimeter constructed as part of the BigBite Spectrometer (BBS), which served as the electron arm for the Super Bigbite Spectrometer (SBS) program of high-precision neutron electromagnetic form factor measurements in Hall A at Jefferson Lab. As a total-absorption calorimeter, BBCal provided the primary electron trigger for BBS, detecting quasi-elastically scattered electrons in the 1–4 GeV energy range with an energy resolution of approximately 6.2%, position resolution of 1.2 cm, and timing resolution of 0.5 ns.

BBCal↗

Performance of the ALICE Electromagnetic Calorimeter

The performance of the electromagnetic calorimeter of the ALICE experiment during operation in 2010–2018 at the Large Hadron Collider is presented. After a short introduction into the design, readout, and trigger capabilities of the detector, the procedures for data taking, reconstruction, and validation are explained. The methods used for the calibration and various derived corrections are presented in detail. Subsequently, the capabilities of the calorimeter to reconstruct and measure photons, light mesons, electrons and jets are discussed. The performance of the calorimeter is illustrated mainly with data obtained with test beams at the Proton Synchrotron and Super Proton Synchrotron or in proton-proton collisions at $\sqrt{s}$ = 13 TeV, and compared to simulations.

47 OTHER INSTRUMENTATION↗

Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20–300 GeV/c

The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing medium and silicon sensors as an active medium in the regions of high radiation exposure, and scintillator tiles directly read out by silicon photomultipliers in the remaining regions. As part of the development of the detector and its readout electronic components, a section of a silicon-based HGCAL prototype detector along with a section of the CALICE AHCAL prototype was exposed to muons, electrons and charged pions in beam test experiments at the H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology as foreseen for the HGCAL but with much finer longitudinal segmentation. The performance of the calorimeters in terms of energy response and resolution, longitudinal and transverse shower profiles is studied using negatively charged pions, and is compared to GEANT4 predictions. This is the first report summarizing results of hadronic showers measured by the HGCAL prototype using beam test data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the local reconstruction algorithms for the CMS hadron calorimeter with Run 2 data

A description is presented of the algorithms used to reconstruct energy deposited in the CMS hadron calorimeter during Run 2 (2015–2018) of the LHC. During Run 2, the characteristic bunch-crossing spacing for proton-proton collisions was 25 ns, which resulted in overlapping signals from adjacent crossings. The energy corresponding to a particular bunch crossing of interest is estimated using the known pulse shapes of energy depositions in the calorimeter, which are measured as functions of both energy and time. A variety of algorithms were developed to mitigate the effects of adjacent bunch crossings on local energy reconstruction in the hadron calorimeter in Run 2, and their performance is compared.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using graph neural networks to reconstruct charged pion showers in the CMS High Granularity Calorimeter

A novel method to reconstruct the energy of hadronic showersin the CMS High Granularity Calorimeter (HGCAL) is presented. TheHGCAL is a sampling calorimeter with very fine transverse andlongitudinal granularity. The active media are silicon sensors andscintillator tiles readout by SiPMs and the absorbers are acombination of lead and Cu/CuW in the electromagnetic section, andsteel in the hadronic section. The shower reconstruction method isbased on graph neural networks and it makes use of a dynamicreduction network architecture. It is shown that the algorithm isable to capture and mitigate the main effects that normally hinderthe reconstruction of hadronic showers using classicalreconstruction methods, by compensating for fluctuations in themultiplicity, energy, and spatial distributions of the shower'sconstituents. The performance of the algorithm is evaluated usingtest beam data collected in 2018 prototype of the CMS HGCALaccompanied by a section of the CALICE AHCAL prototype. Thecapability of the method to mitigate the impact of energy leakagefrom the calorimeter is also demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A High-Throughput MEMS-Based Differential Scanning Calorimeter for Direct Thermal Characterization of Antibodies

Calorimeters, which can be used for rapid thermal characterization of biomolecules, are getting intense attention in drug development. This paper presents a novel MEMS-based differential scanning calorimeter (DSC) for direct thermal characterization of protein samples. The DSC consisted of a pair of temperature sensors made by vanadium oxide (VOx) film with a temperature coefficient of resistivity of –0.025/K at 300 K, a microfluidic device with high thermal insulation (2.8 K/mW), and a Peltier heater for linear temperature scanning. The DSC exhibited high sensitivity (6.1 µV/µW), low noise (0.4 µW), high scanning rate (45 K/min), and low sample consumption volume (0.63 µL). The MEMS DSC was verified by measuring the temperature-induced denaturation of lysozyme at different pH, and then used to study the thermal stability of a monoclonal antibody (mAb), an antigen-binding fragment (Fab), and a dual variable domain immunoglobulin (DVD-Ig) at pH = 6. The results showed that lysozyme is a stable protein in the pH range of 4.0–8.0. The protein stability study revealed that the transition temperatures of the intact Fab fragment, mAb, and DVD proteins were comparable with conformational stability results obtained using conventional commercial DSC. These studies demonstrated that the MEMS DSC is an effective tool for directly understanding the thermal stability of antibodies in a high-throughput and low-cost manner compared to conventional calorimeters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Design, Implementation, and Performance of the Astro-H SXS Calorimeter Array and Anti-Coincidence Detector

The calorimeter array of the JAXA Astro-H (renamed Hitomi) Soft X-ray Spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV, enabling essential plasma diagnostics. The SXS has a square array of 36 microcalorimeters at the focal plane. These calorimeters consist of ion-implanted silicon thermistors and HgTe thermalizing x-ray absorbers. These devices have demonstrated a resolution of better than 4.5 eV at 6 keV when operated at a heat-sink temperature of 50 mK. We will discuss the basic physical parameters of this array, including the array layout, thermal conductance of the link to the heat sink, resistance function, absorber details, and means of attaching the absorber to the thermistor-bearing element. We will also present the thermal characterization of the whole array, including thermal conductance and crosstalk measurements and the results of pulsing the frame temperature via alpha particles, heat pulses, and the environmental background. A silicon ionization detector is located behind the calorimeter array and serves to reject events due to cosmic rays. We will briefly describe this anti-coincidence detector and its performance.

x-ray calorimeter↗

Enhancing sensitivities to long-lived particles with high granularity calorimeters at the LHC

The search for long-lived particles (LLP) is an exciting physics opportunity in the upcoming runs of the Large Hadron Collider. In this paper, we focus on a new search strategy of using the High Granularity Calorimeter (HGCAL), part of the upgrade of the CMS detector, in such searches. In particular, we demonstrate that the high granularity of the calorimeter allows us to see “shower tracks” in the calorimeter, and can play a crucial role in identifying the signal and suppressing the background. We study the potential reach of the HGCAL using a signal model in which the Standard Model Higgs boson decays into a pair of LLPs, h → XX. After carefully estimating the Standard Model QCD and the misreconstructed fake-track backgrounds, we give the projected reach for both an existing vector boson fusion trigger and a novel displaced-track-based trigger. Our results show that the best reach for the Higgs decay branching ratio, BR(h → XX), in the vector boson fusion channel is about O(10 –4 ) with lifetime cτ X ~ 0.1–1 meters, while for the gluon gluon fusion channel it is about O(10 –5 – 10 –6 ) for similar lifetimes. For longer lifetime cτ X ~ 103 meters, our search could probe BR(h → XX) down to a few ×10 –4 (10 –2 ) in the gluon gluon fusion (vector boson fusion) channels, respectively. In comparison with these previous searches, our new search shows enhanced sensitivity in complementary regions of the LLP parameter space. We also comment on many improvements can be implemented to further improve our proposed search.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time Alignment of the CMS Hadron Calorimeter

The Hadron Calorimeter (HCAL) in the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) was recently upgraded for Run 3 (2022-2025) to introduce depth segmentation and online timing measurements. With increased segmentation and readout channels, the HCAL provides new timing capabilities for jets and hadronic tau decays with nearly 4π coverage and sensitivity to highly displaced decays within the calorimeter volume. Recent HCAL timing scans provide a valuable look at artificially delayed jets in collision data and are crucial to improving the detector’s performance. Online timing is utilized for detector alignment based on positioning the pulse rising edge, achieving an alignment accuracy of 0.5 ns, considerably higher than previous energy-weighting based approaches. Using precision arrival time measurements, significant advances have been made in understanding the propagation of hadronic showers throughout the calorimeter.

Kopp, Gillian [Princeton Univ., NJ (United States)↗

Lead tungstate calorimeter of the Jefferson Lab Eta Factory experiment

A new electromagnetic calorimeter (ECAL) consisting of 1596 lead tungstate PbWO 4 scintillating crystals has been fabricated and installed in the experimental Hall D at Jefferson Lab (JLab). The highgranularity, high-resolution calorimeter is required by the JLab Eta Factory experiment, whose main physics goal is to study rare decays of eta mesons. The ECAL replaced the inner part of the forward lead glass calorimeter of the GlueX detector. Signals from the detector will be digitized using twelve-bit flash analog-to-digital converters operated at a sampling rate of 250 MHz. The ECAL is integrated into the trigger system of the GlueX detector using electronics modules designed at JLab. The ECAL is currently at the commissioning stage and should be ready for the physics run in January 2025. We will give an overview of the JEF experiment, the design and construction of the ECAL, and the integration of the detector and its infrastructure into the Hall D experimental setup.

Somov, Alexander [Thomas Jefferson National Accele↗

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗

Charge collection and electrical characterization of neutron irradiated silicon pad detectors for the CMS High Granularity Calorimeter

The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and timing information on electromagnetic and hadronic showers in the immense pileup of the HL-LHC. The High Granularity Calorimeter (HGCAL) will use 120-, 200-, and 300-$\mu\textrm{m}$ thick silicon (Si) pad sensors as the main active material and will sustain 1-MeV neutron equivalent fluences up to about $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$. In order to address the performance degradation of the Si detectors caused by the intense radiation environment, irradiation campaigns of test diode samples from 8-inch and 6-inch wafers were performed in two reactors. Characterization of the electrical and charge collection properties after irradiation involved both bulk polarities for the three sensor thicknesses. Since the Si sensors will be operated at -30 $^\circ$C to reduce increasing bulk leakage current with fluence, the charge collection investigation of 30 irradiated samples was carried out with the infrared-TCT setup at -30 $^\circ$C. TCAD simulation results at the lower fluences are in close agreement with the experimental results and provide predictions of sensor performance for the lower fluence regions not covered by the experimental study. All investigated sensors display 60$\%$ or higher charge collection efficiency at their respective highest lifetime fluences when operated at 800 V, and display above 90$\%$ at the lowest fluence, at 600 V. The collected charge close to the fluence of $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$ exceeds 1 fC at voltages beyond 800 V.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the CMS electromagnetic calorimeter in pp collisions at √$_{s}$ = 13 TeV

The operation and performance of the Compact Muon Solenoid(CMS) electromagnetic calorimeter (ECAL) are presented, based ondata collected in pp collisions at√$_{s}$ =13 TeV at the CERN LHC, in the years from 2015 to 2018(LHC Run 2), corresponding to an integrated luminosity of151 fb$^{-1}$. The CMS ECAL is a scintillating lead-tungstatecrystal calorimeter, with a silicon strip preshower detector in theforward region that provides precise measurements of the energy andthe time-of-arrival of electrons and photons. The successfuloperation of the ECAL is crucial for a broad range of physics goals,ranging from observing the Higgs boson and measuring its properties,to other standard model measurements and searches for newphenomena. Precise calibration, alignment, and monitoring of theECAL response are important ingredients to achieve these goals. Toface the challenges posed by the higher luminosity, whichcharacterized the operation of the LHC in Run 2, the proceduresestablished during the 2011–2012 run of the LHC have been revisitedand new methods have been developed for the energy measurement andfor the ECAL calibration. The energy resolution of the calorimeter,for electrons from Z boson decays reaching theECAL without significant loss of energy by bremsstrahlung, wasbetter than 1.8%, 3.0%, and 4.5% in the |η| intervals[0.0,0.8], [0.8,1.5], [1.5, 2.5], respectively. This resultingperformance is similar to that achieved during Run 1 in 2011–2012,in spite of the more severe running conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving topological cluster reconstruction using calorimeter cell timing in ATLAS

Clusters of topologically connected calorimeter cells around cells with large absolute signal-to-noise ratio (topo-clusters) are the basis for calorimeter signal recon struction in the ATLAS experiment. Topological cell clus tering has proven performant in LHC Runs 1 and 2. It is, however, susceptible to out-of-time pile-up of signals from soft collisions outside the 25 ns proton-bunch-crossing window associated with the event’s hard collision. To reduce this effect, a calorimeter-cell timing criterion was added to the signal-to-noise ratio requirement in the clustering algorithm. Multiple versions of this criterion were tested by reconstructing hadronic signals in simulated events and Run 2 ATLAS data. The preferred version is found to reduce the out-of-time pile-up jet multiplicity by ~50% for jet p T ~ 20 GeV and by ~80% for jet p T ≳ 50 GeV, while not disrupting the reconstruction of hadronic signals of interest, and improving the jet energy resolution by up to 5% for 20 < p T < 30 GeV. Pile-up is also suppressed for other physics objects based on topo-clusters (electrons, photons, τ-leptons), reducing the overall event size on disk by about 6% in early Run 3 pile up conditions. Offline reconstruction for Run 3 includes the timing requirement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗