Search NASA⌕ Search

SEARCH · Search NASA

Results for “CCDs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Sub-GeV dark matter and neutrino searches with Skipper-CCDs: status and prospects

Thick fully-depleted charge-coupled devices (CCDs) with high-resistivity silicon are used in a wide range of scientific applications, from particle detection to astronomical imaging. Their low noise and high charge collection efficiency allow us to reach unprecedented sensitivity to physical processes with low-energy transfers. The newly-developed Skipper-CCD enhances this sensitivity by reducing the read-out noise reaching a sub-electron resolution. In this work, we summarize the fundamentals of the skipper-CCD operation and the prospects for both sub-GeV dark-matter searches and the detection of coherent elastic neutrino-nucleus scattering. A brief discussion of the challenges associated with the construction of the foreseen detectors with multi-kilogram target mass is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral analysis using CCDs

Charge-coupled devices (CCDs) are ideally suited for performing sampled-data transversal filtering operations in the analog domain. Two algorithms have been identified for performing spectral analysis in which the bulk of the computation can be performed in a CCD transversal filter; the chirp z-transform and the prime transform. CCD implementation of both these transform algorithms is presented together with performance data and applications.

Hewes, C. R.↗

Present and future CCDs for UV and X-ray scientific measurements

Interacting quantum efficiencies in excess of 50 percent have been demonstrated with CCDs throughout the spectral range 600-9,00 A, and comparable sensitivity is expected to continue to wavelengths as short as a few Angstroms. Nondispersive X-ray spectra throughout the 250-8000 V range have been obtained with an FWHM spectral resolution of 200-250 eV. At present, however, both spectral and spatial resolution is limited at some energies by the diffusion of photogenerated charge into more than one picture element. Progress in reducing charge diffusion is reported, with particular attention given to a theoretical diffusion model and its implications for further improvement.

Janesick, J. R.↗

CCDs at Lick Observatory

Improved sensitivity to light and uniformity of response has been obtained using various surface treatments of thinned CCDs. Procedures are described and some results are shown. The Lick Observatory data acquisition system is briefly described. A new thermoelectrically-cooled CCD camera for telescope guiding has been designed and built. The camera is described and preliminary results at the telescope are given.

Robinson, Lloyd B.↗

Fano-noise-limited CCDs

Recent developments of scientific CCDs have produced sensors that achieve ultra low read noise performance (less than 2 electrons rms) and near perfect charge transfer efficiency (0.9999996) without the addition of a fat-zero. This progress has now made it possible to achieve Fano-noise-limited performance in the soft X-ray where the detector's energy resolution is primarily limited by the statistical variation in the charge generated by the interacting X-ray photon. In this paper, Fano-noise-limited test data is presented for two different CCD types and a CCD derived estimate of the Fano factor is determined. By evaluating ultra low-modulation images (less than 1 electron peak-to-peak) it is shown that the CCD's global CTE is now superior to its read noise floor. To capitalize on this capability CCD manufacturers are now focusing their attention on reducing the noise floor below the 1 electron level thereby matching the sensor's CTE performance. This improvement, if accomplished, will push Fano-noise-limited performance for the CCD into the extreme ultra-violet.

Janesick, James↗

Performance characteristics of CCDs for the ACIS experiment

The search for the optimum CCD to be used at the focal surface of the Advanced X-ray Astrophysics Facility (AXAF) is described. The physics of the interaction of X-rays in silicon through the photoelectric effect is reviewed. CCD technology at the beginning of the AXAF definition phase is summarized, and the results of the CCD enhancement program are discussed. Other sources of optimum CCDs are examined, and CCD enhancements made at MIT Lincoln Laboratory are addressed.

Garmire, Gordon P.↗

Scientific grade CCDs from EG & G Reticon

The design and performance of three scientific grade CCDs are summarized: a 1200 x 400 astronomical array of 27 x 27 sq micron pixels, a 512 x 512 scientific array of 27 x 27 sq micron pixels and a 404 x 64 VNIR array of 52 x 52 sq micron pixels. Each of the arrays is fabricated using a four phase, double poly, buried n-channel, multi-pinned phase CCD process. Performance data for each sensor is presented.

Cizdziel, Philip J.↗

Radiation test results on TK 1024 CCDs

Results are presented from tests on TK 1024 CCDs with a multipinned phase (MPP) implant built into an experiental mask set. The average dark current as a function of temperature increased by a factor of about 3 for the 5 krads of gammas, which is a 10-fold increase for the extra 2 krads of protons. Histograms of the dark current show two types of dark current, an average level change, and dark current spikes.

Delamere, Alan↗

Taking the CCDs to the ultimate performance for low threshold experiments

Scientific grade CCDs show atractive capabilities for the detection of particles with small energy deposition in matter. Their very low threshold of approximately 40 eV and their good spatial reconstruction of the event are key properties for currently running experiments: CONNIE and DAMIC. Both experiments can benefit from any increase of the detection efficiency of nuclear recoils at low energy. In this work we present two different approaches to increase this efficiency by increasing the SNR of events. The first one is based on the reduction of the readout noise of the device, which is the main contribution of uncertainty to the signal measurement. New studies on the electronic noise from the integrated output amplifier and the readout electronics will be presented together with result of a new configuration showing a lower limit on the readout noise which can be implemented on the current setup of the CCD based experiments. A second approach to increase the SNR of events at low energy that will be presented is the studies of the spatial conformation of nuclear recoil events at different depth in the active volume by studies of new effects that differ from expected models based on not interacting diffusion model of electrons in the semiconductor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Threshold Acquisition controller for Skipper CCDs

The development of the Skipper Charge Coupled Devices (Skipper-CCDs) has been a major technological breakthrough for sensing very weak ionizing particles. The sensor allows to reach the ultimate sensitivity of silicon material as a charge signal sensor by unambiguous determination of the charge signal collected by each cell or pixel, even for single electron-hole pair ionization. Extensive use of the technology was limited by the lack of specific equipment to operate the sensor at the ultimate performance. In this work a simple, single-board Skipper-CCD controller is presented, aimed for the operation of the detector in high sensitivity scientific applications. The article describes the main components and functionality of the Low Threshold Acquisition (LTA) together with experimental results when connected to a Skipper-CCD sensor. Measurements show unprecedented deep sub-electron noise of 0.039 e$^-_{rms}$/pix for 5000 pixel measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Achieving Single-Electron Sensitivity at Enhanced Speed in Fully-Depleted CCDs with Double-Gate MOSFETs

We introduce a new output amplifier for fully-depleted thick p-channel CCDs based on double-gate MOSFETs. The charge amplifier is an n-type MOSFET specifically designed and operated to couple the fully-depleted CCD with high charge-transfer efficiency. The junction coupling between the CCD and MOSFET channels has enabled high sensitivity, demonstrating sub-electron readout noise in one pixel charge measurement. We have also demonstrated the non-destructive readout capability of the device. Achieving single-electron and single-photon per pixel counting in the entire CCD pixel array has been made possible through the averaging of a small number of samples. We have demonstrated fully-depleted CCD readout with better performance than the floating diffusion and floating gate amplifiers available today, in both single and multisampling regimes, boasting at least six times the speed of floating gate amplifiers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Astronomical Spectroscopy with Skipper CCDs: First Results from a Skipper CCD Focal Plane Prototype at SIFS

We present the first on-sky results from an ultra-low-readout-noise Skipper CCD focal plane prototype for the SOAR Integral Field Spectrograph (SIFS). The Skipper CCD focal plane consists of four 6k x 1k, 15 $\mu$m pixel, fully-depleted, p-channel devices that have been thinned to ~250 $\mu$m, backside processed, and treated with an anti-reflective coating. These Skipper CCDs were configured for astronomical spectroscopy, i.e., single-sample readout noise < 4.3 e- rms/pixel, the ability to achieve multi-sample readout noise $\ll$ 1 e- rms/pixel, full-well capacities ~40,000-65,000 e-, low dark current and charge transfer inefficiency (~2 x 10$^{-4}$ e-/pixel/s and 3.44 x 10$^{-7}$, respectively), and an absolute quantum efficiency of $\gtrsim$ 80% between 450 nm and 980 nm ($\gtrsim$ 90% between 600 nm and 900 nm). We optimized the readout sequence timing to achieve sub-electron noise (~0.5 e- rms/pixel) in a region of 2k x 4k pixels and photon-counting noise (~0.22 e- rms/pixel) in a region of 220 x 4k pixels, each with a readout time of $\lesssim$ 17 min. We observed two quasars (HB89 1159+123 and QSO J1621-0042) at redshift z ~ 3.5, two high-redshift galaxy clusters (CL J1001+0220 and SPT-CL J2040-4451), an emission line galaxy at z = 0.3239, a candidate member star of the Bo\"{o}tes II ultra-faint dwarf galaxy, and five CALSPEC spectrophotometric standard stars (HD074000, HD60753, HD106252, HD101452, HD200654). We present charge-quantized, photon-counting observations of the quasar HB89 1159+123 and show the detector sensitivity increase for faint spectral features. We demonstrate signal-to-noise performance improvements for SIFS observations in the low-background, readout-noise-dominated regime. We outline scientific studies that will leverage the SIFS-Skipper CCD data and new detector architectures that utilize the Skipper floating gate amplifier with faster readout times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterising CCDs with cosmic rays

The properties of cosmic ray muons make them a useful probe for measuring the properties of thick, fully depleted CCD sensors. The known energy deposition per unit length allows measurement of the gain of the sensor's amplifiers, whilst the straightness of the tracks allows for a crude assessment of the static lateral electric fields at the sensor's edges. The small volume in which the muons deposit their energy allows measurement of the contribution to the PSF from the diffusion of charge as it drifts across the sensor. In this work we present a validation of the cosmic ray gain measurement technique by comparing with radioisotope gain measurments, and calculate the charge diffusion coefficient for prototype LSST sensors.

79 ASTRONOMY AND ASTROPHYSICS↗

An automated system to measure the quantum efficiency of CCDs for astronomy

We describe a system to measure the Quantum Efficiency in the wavelength range of 300 nm to 1100 nm of 40 × 40 mm n-channel CCD sensors for the construction of the 3.2 gigapixel LSST focal plane. The technique uses a series of instrument to create a very uniform flux of photons of controllable intensity in the wavelength range of interest across the face the sensor. This allows the absolute Quantum Efficiency to be measured with an accuracy in the 1% range. Finally, this system will be part of a production facility at Brookhaven National Lab for the basic component of the LSST camera.

79 ASTRONOMY AND ASTROPHYSICS↗

The physics potential of a reactor neutrino experiment with Skipper-CCDs: searching for new physics with light mediators

In this work, we explore the sensitivity to new physics of the recently proposed vIOLETA experiment: a 10 kg Skipper Charged Coupled Device detector deployed 12 meters away from a commercial nuclear reactor core. We investigate two broad classes of models which benefit from the very low energy recoil threshold of these detectors, namely neutrino magnetic moments and light mediators coupled to neutrinos and quarks or electrons. We find that this experimental setup is very sensitive to light, weakly coupled new physics, and in particular that it could probe potential explanations of the event excess observed in XENON1T. We also provide a detailed study on the dependence of the sensitivity on the experimental setup assumptions and on the neutrino flux systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Skipper-CCDs: Current applications and future

This work briefly discusses the potential applications of the Skipper-CCD technology in astronomy and reviews its current use in dark matter and neutrino experiments. An overview of the ongoing efforts to build multi-kilogram experiments with these sensors is given, in the context of the Oscura experiment. First results from the characterization of Oscura sensors from the first 200 mm wafer-fabrication run with a new vendor are presented. The overall yield of the electron counting capability of these sensors is 71%. In conclusion, a noise of 0.087 e - RMS, with 1225 samples/pix, and a dark current of (0.031±0.013) e - /pix/day at 140 K were measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗