Search NASA⌕ Search

SEARCH · Search NASA

Results for “CHEST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Factors linked to participant attrition in a longitudinal occupational health surveillance program

For occupational medical screening programs focused on long-term health surveillance, participant attrition is a significant barrier to success. Here we investigate demographic, medical history, and clinical data from National Supplemental Screening Program (NSSP) examinees for association with likelihood of return for a second exam (rescreening). A total of 15,733 individuals completed at least one NSSP exam before December 31, 2016; of those, 4832 also completed a second exam on or before December 31, 2019. Stepwise logistic regression models were used to identify variables associated with whether a participant was rescreened in the NSSP. Individuals were less likely to return for rescreening if they had a history of any cancer; cardiovascular problems; diabetes or kidney disease; or if they used insulin. Age at time of first exam and job site category significantly influenced likelihood of return. Workers categorized as “guests” were more likely to return. Participants were less likely to return if they had an abnormal urinalysis, abnormal pulmonary function, pneumoconiosis, aortic atherosclerosis, or hearing loss at their initial exam. Participants who received a chest X-ray at their initial screening were more likely to return. The presence of health problems is strongly linked to screening program attrition. Participants who are older at the time of their initial screening exam are less likely to return. The discovery of several strong demographic, medical, and job associations reveals the importance for medical screening programs to understand and address factors that influence participant retention and, consequently, the effectiveness of long-term health surveillance activities.

60 APPLIED LIFE SCIENCES↗

How much have adverse occupational health outcomes among construction workers improved over time? Evidence from 25 years of medical screening

Background Construction workers have always had a high risk of occupational illnesses. We used 25 years of data from a medical screening program serving older construction workers to determine how much health outcomes have improved over the past 60 years. Methods We investigated changes in relative risk for chest radiographs consistent with pneumoconiosis, COPD by spirometry, lung cancer mortality, and audiometry-assessed hearing impairment among workers participating in a medical screening program. Results were stratified by decade of first construction employment: before 1960, 1960–1969, 1970–1979, 1980–1989, and after 1990. Poisson and Cox regression analyses assessed relative risk by decade adjusted for age, sex, smoking, and years of construction trade work. Results Subjects were 94% male and, on average, 60 years old with 25 years of construction work. When compared to workers employed before 1960, those first employed after 1990 experienced the following reductions in model-adjusted relative risks: chronic obstructive pulmonary disease, 32%; all pneumoconiosis, 68%; parenchymal abnormalities, 35%; pleural abnormalities, 71%; hearing impairment, 20%; and lung cancer mortality, 48%. Risks started to decline in the 1960s with greatest reductions among workers first employed after 1970. Conclusions This study demonstrates the positive impact that adoption of occupational health protections have had over the past 60 years. The greatest risk reductions were observed for outcomes with strong regulatory and legal incentives to reduce exposures and associated risks, such as those associated with inhalation hazards (asbestos and silica), while lowest improvement was for hearing impairment, for which little regulatory enforcement and few prevention incentives have been adopted.

60 APPLIED LIFE SCIENCES↗

Restrictive spirometry pattern among construction trade workers

Spirometry-based studies of occupational lung disease have mostly focused on obstructive or mixed obstructive/restrictive outcomes. We wanted to determine if restrictive spirometry pattern (RSP) is associated with occupation and increased mortality. Study participants included 18,145 workers with demographic and smoking data and repeatable spirometry. The mortality analysis cohort included 15,445 workers with known vital status and cause of death through December 31, 2016. Stratified analyses explored RSP prevalence by demographic and clinical variables and trade. Log-binomial regression models explored RSP risk factors while controlling for important confounders such as smoking, obesity, and comorbidities. Cox regression models explored mortality risk by spirometry category. Prevalence of RSP was very high (28.6%). Mortality hazard ratios for RSP were 1.50 for all causes, 1.86 for cardiovascular diseases, 2.31 for respiratory diseases, and 1.66 for lung cancer. All construction trades except painters, machinists, and roofers had significantly elevated risk for RSP compared to our internal reference group. RSP was significantly associated with both parenchymal and pleural changes seen by chest X-ray. Construction trade workers are at significantly increased risk for RSP independent of obesity. Individuals with RSP are at increased risk for all-cause mortality as well as mortality attributable to respiratory diseases, cardiovascular diseases, and lung cancer. RSP deserves greater attention in occupational medicine and epidemiology.

60 APPLIED LIFE SCIENCES↗

A prospective study on myocardial injury after BNT162b2 mRNA COVID ‐19 fourth dose vaccination in healthy persons

Aims To prospectively evaluate the incidence of myocardial injury after the administration of the fourth dose BNT162b2 mRNA vaccine (Pfizer‐BioNTech) against COVID‐19. Methods and results Health care workers who received the BNT162b2 vaccine during the fourth dose campaign had blood samples collected for high‐sensitivity cardiac troponin (hs‐cTn) during vaccine administration and 2–4 days afterward. Vaccine‐related myocardial injury was defined as hs‐cTn elevation above the 99th percentile upper reference limit and >50% increase from baseline measurement. Participants with evidence of myocardial injury underwent assessment for possible myocarditis. Of 324 participants, 192 (59.2%) were female and the mean age was 51.8 ± 15.0 years. Twenty‐one (6.5%) participants had prior COVID‐19 infection, the mean number of prior vaccine doses was 2.9 ± 0.4, and the median time from the last dose was 147 (142–157) days. Reported vaccine‐related adverse reactions included local pain at injection site in 57 (17.59%), fatigue in 39 (12.04%), myalgia in 32 (9.88%), sore throat in 21 (6.48%), headache in 18 (5.5%), fever ≥38°C in 16 (4.94%), chest pain in 12 (3.7%), palpitations in 7 (2.16%), and shortness of breath in one (0.3%) participant. Vaccine‐related myocardial injury was demonstrated in two (0.62%) participants, one had mild symptoms and one was asymptomatic; both had a normal electrocardiogram and echocardiography. Conclusion In a prospective investigation, an increase in serum troponin levels was documented among 0.62% of healthy health care workers receiving the fourth dose BNT162b2 vaccine. The two cases had mild or no symptoms and no clinical sequela. Clinical Trial Registration: ClinicalTrials.gov Identifier: NCT05308680.

Levi, Nir↗

An Alternative Casting Technique to Improve the Creep Resistance of Cast INCONEL Alloy 740H

The increasing performance requirements of power plant designs, such as advanced-ultra supercritical (A-USC), require the use of Ni-based superalloys to replace high-strength, ferritic-martensitic steels for components subjected to temperatures above 898 K (625 °C) and for austenitic stainless steels components at temperatures above 973 K (700 °C). To date, commercial Ni-based superalloy INCONEL 740H has been shown to be appropriate for use in A-USC power plants as boiler components in a wrought product. However, large complex components in boilers as well as other casings in the turbine and valve chest require castings of a thick-wall nature. Using the alloy in its cast form would be significantly valuable in terms of range of component size, geometry and complexity. Previous investigations revealed short creep lives from cast INCONEL alloy 740H. Here in this investigation, an alternative casting route that utilized a melt procedure resulting in a fine-grain casting, and in conjunction with a computationally optimized homogenization heat treatment, not only controlled the grain size and grain boundary structure but minimized chemistry variability and segregation. A primarily equiaxed and homogenous grain size distribution was obtained from this approach with better repartition of M 23 C 6 carbides along the grain boundaries. Furthermore, better than 38 pct increase was obtained for this material in comparison to the creep life obtained from the best performing conventionally cast material. More importantly, the fine-grain homogenized (FGH) casting route resulted in the Larson–Miller plot for this material that coincided with that of wrought alloy 740. At low creep stresses (with a test still in progress), the FGH casting is resulting in higher values of the LMP than the wrought alloy.

36 MATERIALS SCIENCE↗

Enabling end-to-end secure federated learning in biomedical research on heterogeneous computing environments with APPFLx

Facilitating large-scale, cross-institutional collaboration in biomedical machine learning (ML) projects requires a trustworthy and resilient federated learning (FL) environment to ensure that sensitive information such as protected health information is kept confidential. Specifically designed for this purpose, this work introduces APPFLx - a low-code, easy-to-use FL framework that enables easy setup, configuration, and running of FL experiments. APPFLx removes administrative boundaries of research organizations and healthcare systems while providing secure end-to-end communication, privacy-preserving functionality, and identity management. Furthermore, it is completely agnostic to the underlying computational infrastructure of participating clients, allowing an instantaneous deployment of this framework into existing computing infrastructures. Experimentally, the utility of APPFLx is demonstrated in two case studies: (1) predicting participant age from electrocardiogram (ECG) waveforms, and (2) detecting COVID-19 disease from chest radiographs. Here, ML models were securely trained across heterogeneous computing resources, including a combination of on-premise high-performance computing and cloud computing facilities. By securely unlocking data from multiple sources for training without directly sharing it, these FL models enhance generalizability and performance compared to centralized training models while ensuring data remains protected. In conclusion, APPFLx demonstrated itself as an easy-to-use framework for accelerating biomedical studies across organizations and healthcare systems on large datasets while maintaining the protection of private medical data.

Biomedical Research↗

Training calibration-based counterfactual explainers for deep learning models in medical image analysis

The rapid adoption of artificial intelligence methods in healthcare is coupled with the critical need for techniques to rigorously introspect models and thereby ensure that they behave reliably. This has led to the design of explainable AI techniques that uncover the relationships between discernible data signatures and model predictions. In this context, counterfactual explanations that synthesize small, interpretable changes to a given query while producing desired changes in model predictions have become popular. This under-constrained, inverse problem is vulnerable to introducing irrelevant feature manipulations, particularly when the model’s predictions are not well-calibrated. Hence, in this paper, we propose the TraCE (training calibration-based explainers) technique, which utilizes a novel uncertainty-based interval calibration strategy for reliably synthesizing counterfactuals. Given the wide-spread adoption of machine-learned solutions in radiology, our study focuses on deep models used for identifying anomalies in chest X-ray images. Using rigorous empirical studies, we demonstrate the superiority of TraCE explanations over several state-of-the-art baseline approaches, in terms of several widely adopted evaluation metrics. Our findings show that TraCE can be used to obtain a holistic understanding of deep models by enabling progressive exploration of decision boundaries, to detect shortcuts, and to infer relationships between patient attributes and disease severity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Self-Powered Autonomous Sensing System for Arctic Ocean using a Frequency-multiplied Cylindrical Triboelectric Nanogenerator

An autonomous sensing system for collecting environmental observations in the Arctic region is critical for the estimation and prediction of climate change. Ocean waves are a great source of energy for these sensing systems but there has been limited research done on small-scale energy harvesting applications in the Arctic Ocean (subsea or surface). The available wave energy in the Arctic Ocean is lower than the typical ocean wave energy due to the low wave frequency, height, and operating months. Although the available wave energy depends on the specific location in the Arctic Ocean, the wave height decreases everywhere during the winter (Jan-March) [1]. Our target location in this work is the Beaufort and Chukchi Seas, which are ice covered for about 195 days per year leaving only a few months (June-November) for wave energy harvesting [2]. During these few months, the average wave frequency is 0.2 Hz and the most common wave frequency is around 0.15 Hz. Many energy harvesting methods are unsuitable for use in the Arctic Ocean because of to the cold temperature, low wave frequency, and low wave height. Triboelectric nanogenerators (TENG) are one of the few energy harvesting methods that excel in these conditions. Zhong et al. [3] designed a stacked pendulum-structured TENG for low-frequency ocean wave energy and reported the device generated a peak power density of 11.2 W/m3 under the low wave frequency of 0.2 Hz. The autonomous sensing system we developed for the Arctic Ocean, the Arctic-TENG, is based on a frequency-multiplied cylindrical TENG (FMC-TENG) which is an optimized TENG configuration for Arctic Ocean conditions due to the high power density under low-frequency wave conditions [4]. Figure 1 shows an FMC-TENG with multiple pairs of free-standing triboelectric-layer mode materials (Aluminum and FEP). The mass and magnet attached to the rotor store gravitational potential energy which is released as kinetic energy when the potential energy overcomes the repulsive magnetic force generated by the opposing magnet attached to the stator. This force unbalance triggers a sudden rotation and swinging motion of the mass which increases the angular velocity of the system and therefore enhances the output power of the TENG system. The main components of the Arctic-TENG are a 3D-printed rotor and stator, electric and dielectric material adhesive tape, and bearings. All these materials were cold-soaked and tested at -40 °C in a chest freezer. Both the 3D-printed parts and adhesives were confirmed to have a minimal effect from the cold temperature. Multiple bearings were tested and the starting torque of each one was compared both at room temperature and -40 °C. The bearing with the lowest starting torque at -40 °C was selected for use in the Arctic-TENG. The Arctic-TENG was tested using an out-of-water motor-driven wave simulator (Figure 2). The wave simulator allows for controlled testing at a wave height of 0.2 m and frequencies between 0.1 Hz to 0.5 Hz. This wave simulator was used for both room temperature and -40 °C testing. The Arctic-TENG generated significantly more power at -40 °C compared to room temperature for each frequency tested. The system stored energy in a supercapacitor via a power management circuit, and the amount of energy stored per day was calculated at different wave frequencies. Based on the conditions at the proposed deployment location (days of non-ice-covered ocean and wave frequency), the amount of stored energy per year from Arctic-TENG was calculated to be enough energy for two transmissions every day. Durability testing was completed on the Arctic-TENG at room temperature to determine the lifetime. The rotor of the Arctic-TENG was attached to a DC motor and spun continuously for several millions of cycles without degradation of the electrical output, demonstrating the feasibility for long-term operation.

Jung, Hyunjun↗

Survey of Image Denoising Methods for Medical Image Classification

Medical imaging devices, such as X-ray machines, inherently produce images that suffer from visual noise. Our objectives were to (i.) determine the effect of image denoising on a medical image classification task, and (ii.) determine if there exists a correlation between image denoising performance and medical image classification performance. We performed the medical image classification task on chest X-rays using the DenseNet-121 convolutional neural network (CNN) and used the peak signal-to-noise ratio (PSNR) and structural similarity (SSIM) metrics as the image denoising performance measures. We first found that different denoising methods can make a statistically significant difference in classification performance for select labels. We also found that denoising methods affect fine-tuned models more than randomly-initialized models and that fine-tuned models have significantly higher and more uniform performance than randomly-initialized models. Lastly, we found that there is no significant correlation between PSNR and SSIM values and classification performance for our task.

Michael, Peter↗

Enhanced Surgical Decision-Making Tools in Breast Cancer: Predicting 2-Year Postoperative Physical, Sexual, and Psychosocial Well-Being following Mastectomy and Breast Reconstruction (INSPiRED 004)

Background: We sought to predict clinically meaningful changes in physical, sexual, and psychosocial well-being for women undergoing cancer-related mastectomy and breast reconstruction 2 years after surgery using machine learning (ML) algorithms trained on clinical and patient-reported outcomes data. Patients and Methods: We used data from women undergoing mastectomy and reconstruction at 11 study sites in North America to develop three distinct ML models. We used data of ten sites to predict clinically meaningful improvement or worsening by comparing pre-surgical scores with 2 year follow-up data measured by validated Breast-Q domains. We employed ten-fold cross-validation to train and test the algorithms, and then externally validated them using the 11th site’s data. We considered area-under-the-receiver-operating-characteristics-curve (AUC) as the primary metric to evaluate performance. Results: Overall, between 1454 and 1538 patients completed 2 year follow-up with data for physical, sexual, and psychosocial well-being. In the hold-out validation set, our ML algorithms were able to predict clinically significant changes in physical well-being (chest and upper body) (worsened: AUC range 0.69–0.70; improved: AUC range 0.81–0.82), sexual well-being (worsened: AUC range 0.76–0.77; improved: AUC range 0.74–0.76), and psychosocial well-being (worsened: AUC range 0.64–0.66; improved: AUC range 0.66–0.66). Baseline patient-reported outcome (PRO) variables showed the largest influence on model predictions. Conclusions: Machine learning can predict long-term individual PROs of patients undergoing postmastectomy breast reconstruction with acceptable accuracy. This may better help patients and clinicians make informed decisions regarding expected long-term effect of treatment, facilitate patient-centered care, and ultimately improve postoperative health-related quality of life.

60 APPLIED LIFE SCIENCES↗

Novel Chalcopyrites for Advanced Photoelectrochemical Water Splitting

With the support of DoE’s EERE office, our team has established a unique tool-chest of capabilities, including theoretical modeling (Lawrence Livermore National Laboratory: LLNL), state-of-the-art synthesis (Hawaii Natural Energy Institute: HNEI, Stanford, and the National Renewable Energy Laboratory: NREL) and advanced materials and interfaces characterization (University of Nevada, Las Vegas: UNLV, and Lawrence Berkeley National Laboratory: LBNL), to accelerate the development of high efficiency and durable chalcopyrite materials for advanced photoelectrochemical (PEC) water splitting. Using this synergistic approach, we have successfully created new wide bandgap chalcopyrite photocathodes generating over 10 mA/cm 2 , developed innovative strategies to protect them from corrosion, and engineered novel integration methods to circumvent thin film materials mechanical, chemical and thermal incompatibility. In Task 1 “Modeling and synthesis of chalcopyrite photocathodes”, we expanded our library of wide bandgap chalcopyrites for PEC water splitting. With support from LLNL’s “Computational Materials Diagnostics and Optimization of PEC Devices”, LBNL’s “photophysical” and NREL’s “I-III-VI Compound Semiconductors for Water-Splitting” nodes, we investigated two new chalcopyrite candidates for PEC water splitting: Cu(In,Al)Se 2 and Cu(In,B)Se 2 . We also further developed ordered vacancy compounds, such as CuGa 3 Se 5 , with unprecedented durability during PEC waters splitting in acidic solutions. In Task 2 “Interfaces engineering for enhanced efficiency and durability”, we addressed both the non-ideal band-edge positions of chalcopyrites with respect to water redox potentials, as well as their chemical instability under PEC water splitting, with a buried-junctions approach. With help from NREL’s “High-Throughput Experimental Thin Film Combinatorial Capabilities” and “Corrosion Analysis of Materials” nodes, we engineered environmentally friendly n-type buffers, including Mn x Zn 1-x O, to adjust the chalcopyrite band-edge positions and achieved photovoltages as high as 925 mV. Also, we integrated non-precious catalytic-protecting layers, such as WO 3 , to enhance the water splitting long-term stability of chalcopyrite absorbers. Finally, in Task 3 “Hybrid photoelectrode device integration”, we proposed an innovative method to bond wide bandgap photocathodes onto narrow bandgap PV drivers at room temperature using conductive polymers. Our semi-monolithic approach addressed fundamental processing incompatibility issues, as both the photocathode and the PV driver are processed separately. Proof-of-concept whole-chalcopyrite tandems were obtained by consecutive exfoliation and transfer of fully integrated 1.85 eV CuGa 3 Se 5 and 1.13 eV CuInGaSe 2 stacks from their Mo/SLG substrates onto a new single FTO host substrate.

08 HYDROGEN↗

Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology

Refrigerator technology has advanced significantly over the last couple of decades. Today’s refrigerators use only about 25% of the energy that was required to power models built in 1975. Even as they continually improve efficiency to meet standards, refrigerators have increased in size by almost 20%, added energy-consuming features such as through-the-door ice, and provide more benefits than ever before. However, a few challenges and technology gaps are preventing further improvement of the demand responsiveness and efficiency of the refrigerators. One of the major technology gaps in existing refrigerators is their outdated de-icing process. When the evaporator generates frost, an old-fashioned resistive heating element melts the ice. Most refrigerators have a timed defrost cycle, rather than an active system that could monitor the state of the frost. In these systems, not only is the precious electricity used at its least efficient form of conversion (direct conversion of electricity to heat), but also all the latent heat associated with the ice is wasted during the melting process. On top of that, the refrigerator needs to work harder to pull the temperature down after defrosting, and, last but not least, the food quality is severely impacted by the temperature swings during the defrost cycle. According to a study, the EU alone wastes 89 million tons of food in the supply chain every year. Any temperature swing during defrosting (about 6F according to Emerson for low-temperature cases) can negatively impact the shelf life of meat and other products for multiple days. All these issues can happen during the peak demand time of the electric grid. Unlike the conventional systems, the proposed novel advanced micro-vibrational deicing process uses no heat for defrosting. Instead, it uses the micro vibrations generated by a piezoelectric or vibration-generating module to mechanically break ice from the heat exchanger almost instantaneously. The project titled “Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology, performed by Ultrasonic Technology Solutions, LLC (UTS) of Knoxville, TN, in collaboration with Emerson (now Copeland), represents the final phase of a multi-year effort funded under the U.S. Department of Energy’s Building Technologies Office (BTO) BENEFIT FOA 2020. Initiated on October 1, 2021, and completed after a nine-month no-cost extension ending September 30, 2025, this project aimed to develop and validate a novel micro-vibrational mechanical defrosting system, achieving more than 25% improvement in defrosting energy efficiency over conventional baseline defrosting technologies. Over sixteen quarters, the project advanced from fundamental ice-mechanical characterization and prototype development to full-scale system integration and validation. Initial efforts established project management infrastructure and characterized ice adhesion properties, followed by the design and fabrication of early aluminum-based prototypes for resonance frequency testing. Subsequent quarters saw rapid technical progression, including the identification of optimal piezoelectric and motor-based vibration mechanisms, the demonstration of effective de-icing over 6x6-inch aluminum surfaces. The team achieved its Go/No-Go milestone by exceeding the 25% energy-efficiency improvement target—reaching up to 3,340% under optimized conditions—and later confirmed that motor-driven systems offered superior performance and energy efficiency compared to piezoelectric alternatives. Continued refinement led to the development of amplifier systems on printed circuit boards, improved control and instrumentation hardware, and integration into full-scale heat exchanger (HX) prototypes at both UTS and Copeland facilities. Multiple vibration-mounting studies and frost-growth experiments guided mechanical optimization and noise-mitigation strategies, achieving a 17.5 dB reduction in sound pressure level and verifying robust mechanical performance. Advanced analyses, including modal and harmonic simulations, established a quantitative understanding of vibrational behavior and de-icing efficiency across >1000 cm² systems. The final project phase successfully demonstrated scalable integration within reach-in and chest freezer prototypes, confirmed >25% efficiency improvements in large-area systems, and completed a comprehensive business model and scale-up strategy identifying electric defrost systems as the primary beachhead market. The culmination of this DOE-supported effort establishes micro-vibrational defrosting as a viable, high-efficiency, low-noise, and demand-flexible de-icing technology, paving the way for commercial deployment and broader application in next-generation refrigeration systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Case report: Fatal Legionella infection diagnosed via by metagenomic next-generation sequencing in a patient with chronic myeloid leukemia

Legionella is an aerobic, gram-negative, intracellular pathogen and is an important cause of community-acquired pneumonia. Legionella pneumophila is the most common causative agent of Legionella pneumonia. Clinical diagnosis of Legionella pneumonia is challenging due to the lack of specific clinical manifestations and the low positive rates of conventional pathogen detection methods. In this study, we report a case of a patient with chronic myeloid leukemia who developed rigors and high fever after chemotherapy and immunotherapy. Chest computed tomography revealed consolidation in the left lower lobe of the lung and ground-glass opacities in both lower lobes. Multiple blood cultures showed Escherichia coli , Staphylococcus aureus , Bacillus licheniformis , and positive results in the β-D-glucan test (G test). The patient was treated with various sensitive antimicrobial agents, including meropenem plus fluconazole, meropenem plus carpofungin, and vancomycin. Unfortunately, the patient’s condition gradually worsened and eventually resulted in death. On the following day of death, metagenomic next-generation sequencing (mNGS) of 1whole blood revealed L. pneumophila pneumonia with concurrent bloodstream infection (blood mNGS reads 114,302). These findings suggest that when conventional empirical antimicrobial therapy proves ineffective for critically ill patients with pneumonia, the possibility of combined Legionella infection must be considered, and mNGS can provide a diagnostic tool in such cases.

Bu, Chunhong↗

Evaluation of Deep Learning Model Architectures for Point-of-Care Ultrasound Diagnostics

Point-of-care ultrasound imaging is a critical tool for patient triage during trauma for diagnosing injuries and prioritizing limited medical evacuation resources. Specifically, an eFAST exam evaluates if there are free fluids in the chest or abdomen but this is only possible if ultrasound scans can be accurately interpreted, a challenge in the pre-hospital setting. In this effort, we evaluated the use of artificial intelligent eFAST image interpretation models. Widely used deep learning model architectures were evaluated as well as Bayesian models optimized for six different diagnostic models: pneumothorax (i) B- or (ii) M-mode, hemothorax (iii) B- or (iv) M-mode, (v) pelvic or bladder abdominal hemorrhage and (vi) right upper quadrant abdominal hemorrhage. Models were trained using images captured in 27 swine. Using a leave-one-subject-out training approach, the MobileNetV2 and DarkNet53 models surpassed 85% accuracy for each M-mode scan site. The different B-mode models performed worse with accuracies between 68% and 74% except for the pelvic hemorrhage model, which only reached 62% accuracy for all model architectures. These results highlight which eFAST scan sites can be easily automated with image interpretation models, while other scan sites, such as the bladder hemorrhage model, will require more robust model development or data augmentation to improve performance. With these additional improvements, the skill threshold for ultrasound-based triage can be reduced, thus expanding its utility in the pre-hospital setting.

47 OTHER INSTRUMENTATION↗

Respiration Signal Pattern Analysis for Doppler Radar Sensor with Passive Node and Its Application in Occupancy Sensing of a Stationary Subject

Doppler radar node occupancy sensors are promising for applications in smart buildings due to their simple circuits and price advantage compared to quadrature radar sensors. However, single-channel sensitivity limitations may result in low sensitivity and misinterpreted motion rates if the detected subject is at or close to “null” points. We designed and tested a novel method to eliminate such limits, demonstrating that passive nodes can be used to detect a sedentary person regardless of position. This method is based on characteristics of chest motion due to respiration, found via both simulations and experiments based on a sinusoidal model and a more realistic model of cardiorespiratory motion. In addition, respiratory rate variability is considered to distinguish a true human presence from a mechanical target. Sensor node data were collected simultaneously with an infrared camera system, which provided a respiration signal reference, to test the algorithm with 19 human subjects and a mechanical target. The results indicate that a human presence was detected with 100% accuracy and successfully differentiated from a mechanical target in a controlled environment. The developed method can greatly improve the occupancy detection accuracy of single-channel radar-based occupancy sensors and facilitate their adoption in smart building applications.

Song, Chenyan↗