Search NASA⌕ Search

SEARCH · Search NASA

Results for “CHLORIDE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The sodium chloride primary pressure gauge

The failure of a central force model for sodium chloride is discussed. It is noted that it does not closely satisfy the Cauchy conditions at low temperatures, and that it fails the central force requirement of the Love condition. The available shock data for sodium chloride and its analysis is examined, and two reasons why the Hugoniot transformation pressure is likely to be less than 231 kbar are discussed. The important (but unjustified) theoretical assumptions made in converting Hugoniot to isothermal data is discussed; it is noted that serious error can enter for very large pressures for a given material and that at such high pressures the isothermal data should thus be considered only semiquantitative even if the Hugoniot data itself is accurate. An alternate method of estimating the isothermal transformation pressure from the Hugoniot transformation pressure is used. This method is based on the temperature derivative of the transformation pressure. On this basis it is concluded that an upper bound for the isothermal transformation of NaCl (to a CsCl-type structure) at room temperature is 257 kbar; it is noted that the actual value may be considerably less than this.

Ruoff, A. L.↗

Adsorption and chemical reaction of gaseous mixtures of hydrogen chloride and water on aluminum oxide and application to solid-propellant rocket exhaust clouds

Hydrogen chloride (HCl) and aluminum oxide (Al2O3) are major exhaust products of solid rocket motors (SRM). Samples of calcination-produced alumina were exposed to continuously flowing mixtures of gaseous HCl/H2O in nitrogen. Transient sorption rates, as well as maximum sorptive capacities, were found to be largely controlled by specific surface area for samples of alpha, theta, and gamma alumina. Sorption rates for small samples were characterized linearly with an empirical relationship that accounted for specific area and logarithmic time. Chemisorption occurred on all aluminas studied and appeared to form from the sorption of about a 2/5 HCl-to-H2O mole ratio. The chemisorbed phase was predominantly water soluble, yielding chloride/aluminum III ion mole ratios of about 3.3/1 suggestive of dissolved surface chlorides and/or oxychlorides. Isopiestic experiments in hydrochloric acid indicated that dissolution of alumina led to an increase in water-vapor pressure. Dissolution in aqueous SRM acid aerosol droplets, therefore, might be expected to promote evaporation.

Cofer, W. R., III↗

Effect of oxygen, methyl mercaptan, and methyl chloride on friction behavior of copper-iron contacts

Sliding friction experiments were conducted with an iron rider on a copper disk and a copper rider on an iron disk. The sputter cleaned iron and copper disk surfaces were saturated with oxygen, methyl mercaptan, and methyl chloride at atmospheric pressure. Auger emission spectroscopy was used to monitor the surfaces. Lower friction was obtained in all experiments with the copper rider sliding on the iron disk than when the couple was reversed. For both iron and copper disks, methyl mercaptan gave the best surface coverage and was most effective in reducing friction. For both iron and copper disks, methyl chloride was the least effective in reducing friction. With sliding, copper transferred to iron and iron to copper.

Buckley, D. H.↗

Hazards of lithium thionyl chloride batteries

Two different topics which only relate in that they are pertinent to lithium thionyl chloride battery safety are discussed. The first topic is a hazards analysis of a system (risk assessment), a formal approach that is used in nuclear engineering, predicting oil spills, etc. It is a formalized approach for obtaining assessment of the degree of risk associated with the use of any particular system. The second topic is a small piece of chemistry related to the explosions that can occur with lithium thionyl chloride systems. After the two topics are presented, a discussion is generated among the Workshop participants.

Parry, J. M.↗

The chemistry of sodium chloride involvement in processes related to hot corrosion

Sodium chloride is one of the primary contaminants that enter gas turbine engines and contribute, either directly or indirectly, to the hot corrosion degradation of hot-gas-path components. The paper surveys the results of laboratory experiments along with thermodynamic and mass transport calculations, intended for elucidating the behavior of sodium chloride in combustion environments. It is shown that besides being a source of sodium for the formation of corrosive liquid Na2SO4, the NaCl itself contributes in other indirect ways to the material degradation associated with the high-temperature environmental attack. In addition, the experimental results lend credence to the conceptual scheme presented schematically (behavior of NaCl in a turbine engine combustion gas environment) and resolve conflicting aspects of relevant NaCl misconceptions.

Stearns, C. A.↗

Concentration distribution of methyl chloride in the atmosphere

Electron capture gas chromatography techniques were used to obtain measurements of methyl chloride concentrations in the atmosphere, at latitudes ranging from about 65 N to 90 S. Most of the measurements were made over the Pacific Ocean. Average global concentrations within the boundary layer were found to be 815 plus or minus 25 pptv in 1977 and 755 plus or minus 37 pptv in 1978. Lower concentrations were observed above the boundary layer with average values of 629 plus or minus 23 pptv and 618 plus or minus 23 pptv in 1977 and 1978, respectively. Within 20 deg of the equator, the boundary layer concentrations were significantly higher than those above the boundary layer. The sources, the sinks, the budgets, and the latitudinal distributions of methyl chloride are discussed in the paper.

Rasmussen, R. A.↗

Effect of chloride contamination in MON-1 propellant on crack growth properties of metals

The effect of a high level of chloride content (800 ppm) in MON-1 propellant on the crack growth properties of seven materials was investigated. Sustained load tests were conducted at 49 C (120 F) temperature with thin gauge tensile specimens having a semi-elliptical surface flaw. Alloys included aluminum 1100, 3003, 5086 and 6061; corrosion resistant steel types A286 and 347; and titanium 6Al-4V. The configurations tested with precracked flaws exposed to MON-1 were: parent or base metal, center weld, and heat affected zone. It was concluded that this chloride level in MON-1 does not affect the stress corrosion, crack growth properties of these alloys after 1000 hour exposure duration under high stresses.

Moran, C. M.↗

Case-positive versus case-negative designs for low-rate lithium thionyl chloride cells

Case polarity design choices are discussed. Two examples of case-negative designs are presented. One battery is thionyl chloride limited and the other is lithium limited. The case-positive design is thionyl chloride limited. It is found that the case-positive/case-negative design consideration does not seem to have much bearing on storage. However, during low rate discharge, the case-negative cells show a steadily decreasing capacity as you go to lower and lower rates.

Mahy, T. X.↗

Hydrogen chloride measurements in the Space Shuttle exhaust cloud - First launch, April 12, 1981

Partitioning of hydrogen chloride between the aerosol and gaseous phases in the first Space Shuttle exhaust cloud was experimentally investigated as the exhaust cloud was diluted with ambient air. Airborne measurements were obtained of gaseous hydrogen chloride (HCl), total HCl, relative humidity, and temperature to determine the conditions controlling HCl aerosol formation in the Shuttle exhaust cloud. Two segments of the cloud, each at a significantly different relative humidity, were monitored. Equilibrium predictions of HCl aerosol formation agreed with the measured HCl partitioning at the higher and lower relative humidity conditions, but do not agree at the aerosol formation threshold region. Measurements were taken in the Shuttle exhaust cloud from 8.6 min until 2 h and 8 min after launch. HCl concentrations ranged from 17.5 to 0.9 ppm and relative humidity from 86% to less than 10%.

Sebacher, D. I.↗

Interaction of hydrogen chloride and water with oxide surfaces. III - Titanium dioxide

The adsorption of hydrogen chloride and water vapors on five TiO2 powders in both the anatase and rutile crystalline forms was studied as a function of temperature, pressure, and outgas conditions. The adsorbents were characterized utilizing X-ray powder diffraction, scanning electron microscopy, surface area analysis, indicator method, microelectrophoresis, XPS, and infrared spectroscopy. It was found that both outgas temperature and adsorption temperature influenced the adsorption of water vapor on TiO2, while water vapor adsorption on TiO2 was completely reversible. It is argued that the number of hydroxyl groups present on the surface determines the adsorption capacity of water on the different titanium dioxides. It was found that heats of immersion in water were affected significantly by outgas temperature. Hydrogen chloride adsorption isotherms at 30 C measured on TiO2 after outgassing at 100-400 C showed that a part of the total HCl adsorbed was irreversibly adsorbed. The highest HCl adsorption capacity per unit area was exhibited by anatase, while pure rutile exhibited the lowest adsorption capacity.

Siriwardane, R. V.↗

Surface chloride salt formation on Space Shuttle exhaust alumina

Aluminum oxide samples from the exhaust of Space Shuttle launches STS-1, STS-4, STS-5, and STS-6 were collected from surfaces on or around the launch pad complex and chemically analyzed. The results indicate that the particulate solid-propellant rocket motor (SRM) alumina was heavily chlorided. Concentrations of water-soluble aluminum (III) ion were large, suggesting that the surface of the SRM alumina particles was rendered soluble by prior reactions with HCl and H2O in the SRM exhaust cloud. These results suggest that Space Shuttle exhaust alumina particles are good sites for nucleation and condensation of atmospheric water. Laboratory experiments conducted at 220 C suggest that partial surface chloriding of alumina may occur in hot Space Shuttle exhaust plumes.

Cofer, W. R., III↗

Measuring Sodium Chloride Contents of Aerosols

Amount of sodium chloride in individual aerosol particles measured in real time by analyzer that includes mass spectrometer. Analyzer used to determine mass distributions of active agents in therapeutic or diagnostic aerosols derived from saline solutions and in analyzing ocean spray. Aerosol particles composed of sodium chloride introduced into oven, where individually vaporized on hot wall. Vapor molecules thermally dissociated, and some of resulting sodium atoms ionized on wall. Ions leave oven in burst and analyzed by spectrometer, which is set to monitor sodium-ion intensity.

Sinha, M. P.↗

The 5-(4-Ethynylophenoxy) isophthalic chloride

Sulfone-ester polymers containing pendent ethynyl groups and a direct and multistep process for preparing them are disclosed. The multistep process involves the conversion of a pendent bromo group to the ethynyl group while the direct route involves reating hydroxy-terminated sulfone oligomer or polymers with a stoichiometric amount of 5-(4-ethynylphenoxy) isophthaloyl chloride. The 5-(4-ethynylphenoxy) isophthaloyl chloride and the process for preparing it are also disclosed.

Hergenrother, P. M.↗

Optimization of the lithium/thionyl chloride battery

The progress which has been made in modeling the lithium/thionyl chloride cell over the past year and proposed research for the coming year are discussed. A one-dimensional mathematical model for a lithium/thionyl chloride cell has been developed and used to investigate methods of improving cell performance. During the course of the work a problem was detected with the banded solver being used. It was replaced with one more reliable. Future work may take one of two directions. The one-dimensional model could be augmented to include additional features and to investigate in more detail the cell temperature behavior, or a simplified two-dimensional model for the spirally wound design of this battery could be developed to investigate the heat flow within the cell.

White, Ralph E.↗

Reaction of iron with hydrogen chloride-oxygen mixtures at 550 C

The reaction of iron with 1 percent HCl/0-50 percent O2/Ar has been studied at 550 C with thermogravimetry to monitor kinetics and scanning electron microscopy to characterize product morphologies. In addition, the volatile species were identified with an atmospheric pressure sampling mass spectrometer. The reaction of 1 percent HCl/Ar produces FeCl2. The reactions of 1 percent HCl/1, 10, 50 percent O2/Ar produce Fe2O3, Fe3O4, FeCl2, and FeCl3. In each case condensed phase chlorides form at the oxide/metal interface where the oxygen potential is low. The 10 and 50 percent oxygen mixtures have kinetics in the first 3 hr similar to pure oxidation with some deviations due to iron-chloride formation. The 1 percent oxygen mixture shows enhanced reaction rates over oxidation, very likely due to the formation of a porous scale.

Jacobson, N. S.↗

Characterization of cobalt(II) chloride-modified condensation polyimide films

The effect of solvent extraction on the properties of cobalt(II) chloride-modified polyimide films was investigated. Solvent-cast films were prepared from solutions of cobalt chloride in poly(amide acid)/N,N-dimethylacetamide (DMAc) and were subsequently dried and cured in static air, forced air, or inert gas ovens with controlled humidity. The films were extracted by either of the three processes (1) soaking in a tray with distilled water at room temperature, (2) soxhlett extraction with distilled water, or (3) soxhell extraction with DMAc. Extraction with DMAc was found to remove both cobalt and chlorine from the films and to slightly increase bulk thermal stability and both surface resistivity and electrical resistivity.

Rancourt, J. D.↗

Copper chloride cathode for a secondary battery

Higher energy and power densities are achieved in a secondary battery based on molten sodium and a solid, ceramic separator such as a beta alumina and a molten catholyte such as sodium tetrachloroaluminate and a copper chloride cathode. The higher cell voltage of copper chloride provides higher energy densities and the higher power density results from increased conductivity resulting from formation of copper as discharge proceeds.

Bugga, Ratnakumar V.↗

Molybdenum In Cathodes Of Sodium/Metal Chloride Cells

Cyclic voltammetric curves of molybdenum wire in NaAlCl4 melt indicate molybdenum chloride useful as cathode material in rechargeable sodium/metal chloride electrochemical cells. Batteries used in electric vehicles, for electric-power load leveling, and other applications involving high energy and power densities.

Bugga, Ratnakumar V.↗