Search NASA⌕ Search

SEARCH · Search NASA

Results for “COAXIAL CABLE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Development of a capacitance measurement for pulsed magnetic fields

Capacitance measurements are crucial for probing the electrical properties of materials. In this study, we develop and implement a capacitance measurement technique optimized for pulsed magnetic fields. Our approach employs an auto-balancing bridge method, leveraging a high-bandwidth transimpedance amplifier to mitigate parasitic contributions from coaxial cables. This technique enables precise capacitance measurements in rapidly changing magnetic fields, as demonstrated in experiments on the magnetoelectric material NiCo 2 TeO 6 . The results reveal strong magnetoelectric coupling, including a pronounced hysteresis in capacitance that coincides with magnetization measurements and an enhanced energy dissipation peak at high sweep rates. Compared to traditional LCR meter measurements in DC fields, our method exhibits excellent agreement while providing additional insight into field-induced phase transitions. This work establishes a robust methodology for capacitance measurements under extreme conditions and opens new opportunities for studying multiferroic and correlated electron systems under high magnetic fields.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantum State Transfer between Heterogeneous 3D QPUs

We present detailed analyses and microwave simulations of a quantum interconnect architecture that couples two distinct three-dimensional quantum processing units (QPUs): (i) a two-cell superconducting radio-frequency (SRF) cavity coupled to multiple transmon qubits and (ii) a waveguide-based cavity hosting a planar circuit with transmons and resonators. The modules are linked via a low-loss superconducting coaxial cable, which serves as a quantum bus. Finite-element electromagnetic simulations are performed to optimize coupling strengths and mode frequencies for high-fidelity quantum state transfer between cavities. These simulation results provide a comprehensive blueprint for the experimental realization of a flexible quantum interconnect architecture, coupling heterogeneous QPUs.

Yaker, Joey [Fermilab]↗

Booster cavity damper redesign for PIP-II

A new Higher Order Mode (HOM) damper was designed and is undergoing testing for the Booster accelerator cavity at Fermilab. In anticipation of the PIP-II upgrade, it was discovered that the higher intensity of PIP-II may cause beam instability due to an excited mode at 106 MHz. This unfortunately corresponds with the cavity’s 2nd order harmonic mode, which will sweep from 86-105.7 MHz. The new damper is a modification of an existing damper that was designed to reduce an existing static HOM at 83 MHz, with the new design intending to cover the 2nd order HOM as well. The existing damper uses an inductive coupling loop to extract RF energy from the cavity which then goes through a filter in order to reflect the fundamental frequency back into the cavity while passing HOMs to a dump load. The new damper intends to replace the filter portion of the system with a wider band variant while also changing the topology from a coaxial cable loop filter to a componentized PCB-based design. Primary design challenges include bandwidth coverage, impedance matching of the various modes, long term thermal and mechanical stability, radiation hardness, and high voltage handling. Initial designs achieved the desired damping but were found to quickly succumb to destructive arcing due to the voltages present. More finalized designs intend to address this problem through circuit design modifications as well as the use of hardier components.

Pieper, Dustin [Fermilab]↗

Booster Cavity Damper Redesign for PIP-II

A new Higher Order Mode (HOM) damper was designed and tested for the Booster accelerator cavity at Fermilab. In anticipation of the PIP-II upgrade, it was discovered that the higher beam intensity of PIP-II may cause beam instability due to an excited mode at 106 MHz. This unfortunately corresponds with the cavity s 2nd order harmonic mode, which will sweep from 86-105.7 MHz. The new damper is a modification of an existing damper that was designed to reduce an existing static HOM at 83 MHz, with the new design intending to cover the 2nd order HOM as well. The existing damper uses an inductive coupling loop to extract RF energy from the cavity which then goes through a filter in order to reflect the fundamental frequency back into the cavity while passing HOMs to a dump load. The new damper intends to replace the filter portion of the system with a wider band variant while also changing the topology from a coaxial cable loop filter to a componentized PCB-based design. Primary design challenges include bandwidth coverage, impedance matching of the various modes, long term thermal and mechanical stability, radiation hardness, and high voltage handling. Initial designs achieved the desired damping but were found to quickly succumb to destructive arcing due to the voltages present. More finalized designs intend to address this problem through circuit design modifications as well as the use of hardier components.

Pieper, Dustin [Fermilab]↗

PIP-II LLRF Master Oscillator and Precision Reference Line - Station Level Design and Testing

The PIP-II superconducting linac at Fermilab requires a highly stable RF Reference Line to maintain phase syn- chronization throughout the accelerator. Temperature- induced changes in the electrical length of long coaxial cables can introduce phase drift and measurement errors. The reference-line architecture mitigates these effects by phase averaging the forward and reflected RF signals, while a phase-locked loop anchors the system to the mas- ter oscillator. This work focuses on the characterization, validation, and mechanical integration of station-level RF assemblies using CAD modeling, vector network analyzer measurements, and spectrum analyzer testing. PID-controlled thermal plates will stabilize critical RF components and further reduce temperature-dependent phase and amplitude variations. These methods sup- port repeatable, standardized designs that can be reliably integrated across the different reference-line stations.

Mosher, Alexander [U. Illinois, Chicago]↗

Masers for the telstar satellite communications experiment

This paper discusses the design and characteristics of ruby traveling-wave masers operating at 4 gc. These masers, characterized by an average gain of ≈35 db over a bandwidth of 25 mc, are equipped with waveguide input transmission lines, rather than the previously employed coaxial cables. This change results in an over-all noise temperature of 3.5°K for these devices, rather than the 10°K exhibited by earlier masers. The maser noise temperature now closely approximates sky temperatures, which set the ultimate limit on earthbound receiver sensitivity. The improvements to be had by further reduction in amplifier noise are therefore almost negligible. A less well known maser property, i.e., its freedom from distortion, even when driven well into gain saturation, is discussed.

TELSTAR SATELLITE↗

Economical weatherproof helical antenna

Semi-rigid coaxial cable forms the helical element of antennas. Antennas are inexpensive, corrosion resistant, require minimum maintenance, and can be easily transported and assembled.

Cribb, H. E.↗

Catheter transducer and circuit

Simple integrated circuit located at transducer, enables use of single coaxial cable for both input and output connections. Circuit is sensitive to changes in RC time constant, has much improved sensitivity characteristics, and is unaffected by changes in cable capacitance effects.

Harrison, D. R.↗

Digital data command bus

Command bus constructed from coaxial cable has short segments of its outer jacket and shield removed and replaced with small ferrite cores carrying multiturn windings connected to decoder. Device reduces number of wire pairs required to communicate command data to systems and subsystems.

Milligan, G. C.↗

A vacuum chamber feedthrough

Simple and inexpensive microwave feedthrough has been designed which transfers 130 ns, 5kV pulse into vacuum chamber. Feedthrough may be used over wide range and is adaptable to most coaxial cables, since either multistrand or single strand center conductor cable can be used.

Brown, V. D.↗