Lunar atmosphere measurements.

Cold cathode ionization gauges were left on the lunar surface during Apollo missions 14 and 15 to measure the amount of lunar gas. The observed nighttime concentration is very low, about 200,000 per cu cm, which is less than the neon concentration that might be expected from the solar wind. This suggests that the lunar surface is not saturated with solar wind neon, and hence that less neon is being released from the surface than impinges upon it. The low nighttime concentration shows that contaminant gases from the Apollo operations freeze out at night or become adsorbed on the cold lunar surface. Observed daytime concentrations have been two orders of magnitude greater than the nighttime values and appear to be due mainly to contamination in the landing area. The rate at which the contamination is decreasing is characterized by a time constant of a few months. Gas clouds have been seen at times and these appear to have been released from Apollo hardware left on the lunar surface.

Johnson, F. S.

SPEAR-1: An experiment to measure current collection in the ionosphere by high voltage biased conductors

An experiment is described in which a high electrical potential difference, up to 45 kV, was applied between deployed conducting spheres and a sounding rocket in the ionosphere. Measurements were made of the applied voltage and the resulting currents for each of 24 applications of different high potentials. In addition, diagnostic measurements of optical emissions in the vicinity of the spheres, energetic particle flow to the sounding rocket, dc electric field and wave data were made. The ambient plasma and neutral environments were measured by a Langmuir probe and a cold cathode neutral ionization gauge, respectively. The payload is described and examples of the measured current and voltage characteristics are presented. The characteristics of the measured currents are discussed in terms of the diagnostic measurements and the in-situ measurements of the vehicle environment. In general, it was found that the currents observed were at a level typical of magnetically limited currents from the ionospheric plasma for potentials less than 12 kV, and slightly higher for larger potentials. However, due to the failure to expose the plasma contactor, the vehicle sheath modified the sphere sheaths and made comparisons with the analytic models of Langmuir-Blodgett and Parker-Murphy less meaningful. Examples of localized enhancements of ambient gas density resulting from the operation of the attitude control system thrusters (cold nitrogen) were obtained. Current measurements and optical data indicated localized discharges due to enhanced gas density that reduced the vehicle-ionosphere impedance.

Raitt, W. John

First field test of a novel optical gas analyser in the exhaust of Wendelstein 7-X

A novel optical gas analyser, designed for isotope-resolved exhaust composition measurement, was field-tested at Wendelstein 7-X (W7-X) to validate its laboratory-proven concept under operational fusion experiment conditions. The system, Optix, comprises a cold cathode remote plasma generator and a high-resolution Fabry–Perot spectrometer and was deployed in the exhaust line of W7-X during the OP2.3 campaign. The injection of 3 He and 4 He for minority ion-cyclotron heating provided a test case for helium isotope discrimination. Despite limitations due to background gas and low partial pressures of the target species, isotope-resolved spectral signatures were successfully observed, demonstrating the fundamental viability of the Optix approach. Additionally, the spectrometer was evaluated for plasma emission measurements from both core and edge sightlines. While helium line emission was detectable, interpretation was hindered by complex background signals, highlighting the benefits of controlled remote plasma generators for spectroscopy. This first deployment provides critical insight into pressure requirements, spectral resolution, and operational constraints, informing future applications of optical exhaust diagnostics in fusion devices.

magnetic confinement fusion

Lunar mass spectrometer test program

The procedures used and the results are described, which were obtained in a test program to demonstrate the performance of a candidate lunar mass spectrometer. The instrument was designed to sample and measure gases believed to exist in the lunar atmosphere at the surface. The instrument consists of a cold cathode ion source, a small quadrupole mass analyzer, and an off-axis electron multiplier ion-counting detector. Instrument resolution, sensitivity, and S/N ratio were demonstrated over the mass range 0-150 amu and over a partial pressure range from ntorr to ptorr. The subject analyzer was also prepared for extended testing, in conjunction with two other candidate instruments, in a large molecular beam vacuum facility.

Torney, F. L.

Development of reverse biased p-n junction electron emission

A cold cathode emitter of hot electrons for use as a source of electrons in vacuum gauges and mass spectrometers was developed using standard Norton electroluminescent silicon carbide p-n diodes operated under reverse bias conditions. Continued development including variations in the geometry of these emitters was carried out such that emitters with an emission efficiency (emitted current/junction current) as high as 3 x 10-0.00001 were obtained. Pulse measurements of the diode characteristics were made and showed that higher efficiency can be attained under pulse conditions probably due to the resulting lower temperatures resulting from such operation.

Fowler, P.

Lunar mass spectrometer test program

The procedures are described along with results obtained in a test program conducted to demonstrate the performance of a candidate lunar mass spectrometer. The instrument was designed to sample and measure gases believed to exist in the lunar atmosphere at the surface. The subject instrument consists of a cold cathode ion source, a small quadrupole mass analyzer and an off axis electron multiplier ion counting detector. The major program emphasis was placed on demonstrating instrument resolution, sensitivity and S/N ratio over the mass range 0-150 amu and over a partial pressure range from 10 to the minus 9th power to 10 to the minus 13th power torr. Ultrahigh vacuum tests were conducted and the minimum detectable partial pressure for neon, argon, krypton and xenon was successfully determined for the spectrometer using isotopes of these gases. With the exception of neon, the minimum detectable partial pressure is approximately 4 x 10 to the minus 14th power torr for the above gases.

Torney, F. L.

The impedance characteristic of a spherical probe in an isotropic plasma.

Experimental investigation of the impedance characteristic of a spherical plasma probe for a quantitative assessment of theoretical work, and of hydrodynamic or fluid theory in particular. A stable, low-temperature (about 500K) plasma was produced in nitrogen by a cold-cathode discharge, with a plasma frequency of the order of 15 MHz and with an electron collision frequency in the range from one to ten million per sec. Hydrodynamic probe theory was tested against the experimental results for the specific cases corresponding to the probe at floating potential and at space potential. Good agreement was obtained for both the real and imaginary parts. The real part of the impedance shows a peak near the plasma frequency, a small shift being explicable in terms of realistic sheath profiles. Electron density can thus be deduced rather accurately, and electron temperature approximately, on the basis of hydrodynamic theory. Accurate values of the electron-neutral collision frequency were also obtained for plasmas where the collision frequency was larger than 0.4 times the radian plasma frequency. At lower pressures the presence of collisionless or Landau damping was clearly established, and the more accurate kinetic theory is necessary to explain the experimental results.

Tarstrup, J.

Vacuum measurements on the lunar surface.

Results of measurements of neutral gas pressure on the lunar surface made with a cold cathode ionization gauge carried to the moon by Apollo 14. The vacuum quality at the landing site is much influenced by the adsorption of rocket gases and their later release. During surface operations by the astronauts, the pressure was near 10 to the minus 8th torr. No data were obtained between the time of the surface operations and lunar sunset about 12 days later, at which time the temperature fell rapidly to the vicinity of 100 K. The pressure was about 10 to the minus 12th torr shortly after sunset, but intermittent releases of gas, perhaps from within the moon itself, occasionally raised the pressure by less than an order of magnitude for as long as a day or two at a time and on one occasion to about 10 to the minus 10th torr for about an hour. At lunar sunrise, as the surface was warmed rapidly to about 300 K, the pressure rose rapidly to about 10 to the minus 10th torr, most likely due to the release of absorbed gases in the immediate landing area or on the landing module itself. For comparison with interplanetary vacuum conditions, the directed pressure of the solar wind is usually less than 10 to the minus 11th torr and the pressure of random gas motion within the solar wind, less than 10 to the minus 13th torr.

Johnson, F. S.

Apollo 15 surface science summary.

The Apollo 15 mission was the fourth manned lunar landing and the northernmost location yet visited. The landing site on the southeastern edge of the Imbrium Basin afforded the opportunity of studying several unique lunar features, the Apennine Mountains, Hadley Rille, and the Imbrium Basin fill. Detailed geological study of the data returned from the mission provided new insight into the structure and history of the Basin. A third Apollo Lunar Surface Experiment Package was deployed during the mission containing seven experiments: Passive Seismometer (PSE), Heat Flow (HFE), Surface Magnetometer (LSM), Suprathermal Ion Detector (SIDE), Cold Cathode Gauge (CCGE), Solar Wind Spectrometer (SWS), and a Dust Detector. We have been able to triangulate on the sources of moonquakes and to observe simultaneous nighttime and daytime changes in the moon's magnetic field, solar wind flux, and the neutral and ionized components of the moon's tenuous atmosphere.

Beattie, D. A.

The earth's atmosphere.

Topics discussed include the effects of solar radiation on the heat balance of the earth and its atmosphere, the physicomathematical models of the atmosphere and the computational schemes used in numerical investigations of the general circulation of the atmosphere, the effects of atmospheric turbulence on aeronautical systems, te chemistry of different regions of the atmosphere, the use of hot-filament and cold-cathode vacuum gauges to measure upper-atmosphere densities, methods of determining the air density at heights near a satellite's perigee by analyzing changes in its orbit, and an evaluation of various atmospheric models in the 100- to 1000-km altitude range.

Vaughan, W. W.

Design, fabrication, assembly and delivery of a laboratory prototype of a residual gas analyzer

The design, development, and testing of a wide mass range residual gas analyzer which will be one component of an integrated real time contamination monitor system are described. The instrument has been developed and tested to the laboratory prototype phase, demonstrating the performance that can be expected from a flight instrument of similar design. The instrument's analyzer is of the quadrupole type and a cold cathode ion source is employed as the ionizer. The associated electronics supply all necessary operating and mass sweep voltages for the ionizer, analyzer and electron multiplier ion detector. The instrument features a very fast linear electrometer with automatic range changing. The full mass range of 2 to 300 amu is automatically and repetitively scanned every sixty seconds and suitable telemetry outputs are provided for intensity and mass identification as well as a digital identification of the electrometer range.

Kreisman, W. S.

Meteoroid detector

A meteoroid detector is described which uses, a cold cathode discharge tube with a gas-pressurized cell in space for recording a meteoroid puncture of the cell and for determining the size of the puncture.

Mcmaster, L. R.

Observations of lunar atmosphere.

A cold cathode ionization gauge was left on the lunar surface by the Apollo 14 astronauts to measure the neutral gas density on the moon. The gauge has detected the presence of a very low concentration of atmospheric particles at night, about 200,000 per cu cm. Gas clouds of locally greater concentrations have been observed at times, and, while the possibility that these are artifacts associated with the Apollo hardware cannot be conclusively ruled out, the clouds appear to be of natural origin. Contaminant gases due to the Apollo operation dominate during the lunar day, but these may dissipate within a few months.

Johnson, F. S.

Role of pressure transients in the detection and identification of lunar surface gas sources.

The dynamic behavior of neutral gases emitted from lunar surface sources is investigated. Pressure transients to be expected from several types of possible lunar surface sources are constructed. An approximate method is developed to estimate the source-sensor separation distance and the amount of effluent release. The case for which the source location and effluent molecular weight can be determined from ancillary data is discussed. It is shown that, if such data are available, pressure transients detected by either Apollo lunar surface experiment package ion spectrometers or cold cathode gages can be used to determine the release rate and the total amount of effluent release from the source.

Hall, F. G.