Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONDENSER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Investigation of Condensing Ice Heat Exchangers for MTSA Technology Development

Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal, carbon dioxide (CO2) and humidity control for a Portable Life Support Subsystem (PLSS). Metabolically-produced CO2 present in the ventilation gas of a PLSS is collected using a CO2selective adsorbent via temperature swing adsorption. The temperature swing is initiated through cooling to well below metabolic temperatures. Cooling is achieved with a sublimation heat exchanger using water or liquid carbon dioxide (LCO2) expanded below sublimation temperature when exposed to low pressure or vacuum. Subsequent super heated vapor, as well as additional coolant, is used to further cool the astronaut. The temperature swing on the adsorbent is then completed by warming the adsorbent with a separate condensing ice heat exchanger (CIHX) using metabolic heat from moist ventilation gas. The condensed humidity in the ventilation gas is recycled at the habitat. The water condensation from the ventilation gas is a significant heat transfer mechanism for the warming of the adsorbent bed because it represents as much as half of the energy potential in the moist ventilation gas. Designing a heat exchanger to efficiently transfer this energy to the adsorbent bed and allow the collection of the water is a challenge since the CIHX will operate in a temperature range from 210K to 280K. The ventilation gas moisture will first freeze and then thaw, sometimes existing in three phases simultaneously. A NASA Small Business Innovative Research (SBIR) Phase 1 contract was performed to investigate condensing and icing as applied to MTSA to enable higher fidelity modeling and assess the impact of geometry variables on CIHX performance for future CIHX design optimization. Specifically, a design tool was created using analytical relations to explore the complex, interdependent design space of a condensing ice heat exchanger. Numerous variables were identified as having nontrivial contributions to performance such as hydraulic diameter, heat exchanger effectiveness, ventilation gas mass flow rate and surface roughness. Using this tool, four test articles were designed and manufactured to map to a full MTSA subassembly (the adsorbent bed, the sublimation heat exchanger for cooling and the condensing ice heat exchanger for warming). The design mapping considered impacts due to CIHX geometry as well as subassembly impacts such as thermal mass and thermal resistance through the adsorbent bed. The test articles were tested at simulated PLSS ventilation loop temperature, moisture content and subambient pressure. Ice accumulation and melting were observed. Data and test observations were analyzed to identify drivers of the condensing ice heat exchanger performance. This paper will discuss the analytical models, the test article designs, and testing procedures. Testing issues will be discussed to better describe data and share lessons learned. Data analysis and subsequent conclusions will be presented.

Padilla, Sebastian↗

Deepak Condenser Model (DeCoM)

Development of the DeCoM comes from the requirement of analyzing the performance of a condenser. A component of a loop heat pipe (LHP), the condenser, is interfaced with the radiator in order to reject heat. DeCoM simulates the condenser, with certain input parameters. Systems Improved Numerical Differencing Analyzer (SINDA), a thermal analysis software, calculates the adjoining component temperatures, based on the DeCoM parameters and interface temperatures to the radiator. Application of DeCoM is (at the time of this reporting) restricted to small-scale analysis, without the need for in-depth LHP component integrations. To efficiently develop a model to simulate the LHP condenser, DeCoM was developed to meet this purpose with least complexity. DeCoM is a single-condenser, single-pass simulator for analyzing its behavior. The analysis is done based on the interactions between condenser fluid, the wall, and the interface between the wall and the radiator. DeCoM is based on conservation of energy, two-phase equations, and flow equations. For two-phase, the Lockhart- Martinelli correlation has been used in order to calculate the convection value between fluid and wall. Software such as SINDA (for thermal analysis analysis) and Thermal Desktop (for modeling) are required. DeCoM also includes the ability to implement a condenser into a thermal model with the capability of understanding the code process and being edited to user-specific needs. DeCoM requires no license, and is an open-source code. Advantages to DeCoM include time dependency, reliability, and the ability for the user to view the code process and edit to their needs.

Patel, Deepak↗

Mars Atmospheric CO2 Condensation Above the North and South Poles as Revealed by Radio Occultation, Climate Sounder, and Laser Ranging Observations

We study the condensation of CO2 in Mars atmosphere using temperature profilesretrieved from radio occultation measurements from Mars Global Surveyor (MGS) as wellas the climate sounding instrument onboard the Mars Reconnaissance Orbiter (MRO),and detection of reflective clouds by the MGS Mars Orbiter Laser Altimeter (MOLA). Wefind 11 events in 1999 where MGS temperature profiles indicate CO2 condensation andMOLA simultaneously detects reflective clouds. We thus provide causal evidence thatMOLA non-ground returns are associated with CO2 condensation, which strongly indicatestheir nature being CO2 clouds. The MGS and MRO temperature profiles together revealthe seasonal expansion and shrinking of the area and the vertical extent of atmosphericsaturation. The occurrence rate of atmospheric saturation is maximized at high latitudes inthe middle of winter. The atmospheric saturation in the northern polar region exhibits moreintense seasonal variation than in the southern polar region. In particular, a shrinking ofsaturation area and thickness from LS 270 to 300 in 2007 is found; this is probablyrelated to a planet-encircling dust storm. Furthermore, we integrate the condensation areaand the condensation occurrence rate to estimate cumulative masses of CO2 condensatesdeposited onto the northern and southern seasonal polar caps. The precipitation flux isapproximated by the particle settling flux which is estimated using the impulse responses ofMOLA filter channels. With our approach, the total atmospheric condensation mass canbe estimated from these observational data sets with average particle size as the onlyfree parameter. By comparison with the seasonal polar cap masses inferred from thetime-varying gravity of Mars, our estimates indicate that the average condensate particleradius is 822 mm in the northern hemisphere and 413 mm in the southern hemisphere.Our multi-instrument data analysis provides new constraints on modeling the global climateof Mars.

MOLA↗

Lignin Extraction and Condensation as a Function of Temperature, Residence Time, and Solvent System in Flow-through Reactors

Solvolytic extraction of lignin from biomass is a critical step in lignin-first biorefining, including the reductive catalytic fractionation (RCF) process. Key to optimal RCF processing is the ability to rapidly extract lignin from biomass at high delignification extents and transfer the lignin molecules to a catalyst surface in a time frame that minimizes lignin condensation reactions. Here, we use a flow-through reactor to study the effects of temperature (175-250 °C), residence time (9 to 36 min), and solvent composition (methanol and methanol-water) on lignin extraction and condensation. We evaluated three metrics at each condition: total delignification, delignification rate, and extent of condensation, the latter measured by a decrease in monomer yield for batch hydrogenolysis reactions of solvolysis liquor compared to batch RCF reactions. We observe that delignification is predominantly determined by temperature, while residence time dictates the lignin condensation extent. Moreover, the extent of both extraction and condensation increased in the methanol-water solvent system compared to that in the methanol system. Lignin extracted in methanol is stable up to 18-min residence times at or below 225 °C, while a majority of the lignin extracted in methanol-water is condensed with a 9-min residence time at 200 °C. These results can inform reactor designs and solvent selection for lignin-first biorefining processes that aim to physically separate the biomass and catalyst.

09 BIOMASS FUELS↗

Flexible and Extensive Platinum Ion Gel Condensers for Programmable Catalysis

Catalytic condensers composed of ion gels separating a metal electrode from a platinum-on-carbon active layer were fabricated and characterized to achieve more powerful, high surface area dynamic heterogeneous catalyst surfaces. Ion gels comprised of poly(vinylidene difluoride)/1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl) imide were spin coated as a 3.8 μm film on a Au surface, after which carbon sputtering of a 1.8 nm carbon film and electron-beam evaporation of 2 nm Pt clusters created an active surface exposed to reactant gases. Electronic characterization indicated that most charge condensed within the Pt nanoclusters upon application of a potential bias, with the condenser device achieving a capacitance of ∼20 μF/cm 2 at applied frequencies of up to 120 Hz. The maximum charge of ∼10 14 |e – | cm –2 was condensed under stable device conditions at 200 °C on catalytic films with ∼10 15 sites cm –2 . Grazing incidence infrared spectroscopy measured carbon monoxide adsorption isobars, indicating a change in the CO* binding energy of ∼19 kJ mol –1 over an applied potential bias of only 1.25 V. Condensers were also fabricated on flexible, large area Kapton substrates allowing stacked or tubular form factors that facilitate high volumetric active site densities, ultimately enabling a fast and powerful catalytic condenser that can be fabricated for programmable catalysis applications.

Catalysis↗

Designing a validation experiment for radio frequency condensation

Abstract Theoretical studies have suggested that nonlinear effects can lead to ‘radio frequency (RF) condensation’, where an initially broad current profile can coalesce in islands when they reach sufficient width. In suitable conditions, RF condensation can ‘self-focus’ the driven current to the center of an island, improving stabilization efficiency and reducing control complexity. In unsuitable conditions, the effect can prematurely deplete the RF energy before it reaches the island center, impairing stabilization. It is predicted that the RF condensation effect can significantly impact reactor-scale tokamaks. This paper presents a set of simulations investigating the conditions under which RF condensation might be encountered in present-day tokamaks. For concreteness, the calculations use equilibrium reconstructions for two shots from DIII-D and AUG. The Current Condensation Amid Magnetic Islands (OCCAMI) simulation code has been used for this investigation. The code takes as its input a numerically specified axisymmetric EFIT equilibrium solution, and it perturbatively constructs a 3D field with an island embedded at the appropriate rational surface. In the OCCAMI code, the GENRAY code is used for ray tracing and for calculating the power deposition along a ray trajectory, and GENRAY is coupled self-consistently to a solution of the thermal diffusion equation in the island. The simulation results described in the paper illuminate the conditions required for experimental validation of the theory of RF condensation. The simulations also provide an explanation of why the effect was not noticed in experiments prior to the publication of theoretical papers on the subject.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lignin Extraction and Condensation as a Function of Temperature, Residence Time, and Solvent System in Flow-through Reactors

Solvolytic extraction of lignin from biomass is a critical step in lignin-first biorefining, including the reductive catalytic fractionation (RCF) process. Key to optimal RCF processing is the ability to rapidly extract lignin from biomass at high delignification extents and transfer the lignin molecules to a catalyst surface in a time frame that minimizes lignin condensation reactions. Here, we use a flow-through reactor to study the effects of temperature (175–250 °C), residence time (9 to 36 min), and solvent composition (methanol and methanol–water) on lignin extraction and condensation. We evaluated three metrics at each condition: total delignification, delignification rate, and extent of condensation, the latter measured by a decrease in monomer yield for batch hydrogenolysis reactions of solvolysis liquor compared to batch RCF reactions. We observe that delignification is predominantly determined by temperature, while residence time dictates the lignin condensation extent. Moreover, the extent of both extraction and condensation increased in the methanol–water solvent system compared to that in the methanol system. Lignin extracted in methanol is stable up to 18-min residence times at or below 225 °C, while a majority of the lignin extracted in methanol–water is condensed with a 9-min residence time at 200 °C. These results can inform reactor designs and solvent selection for lignin-first biorefining processes that aim to physically separate the biomass and catalyst.

biorefining↗

Switchable Wettability for Condensation Heat Transfer

Condensation proceeds as dropwise or filmwise depending on the wettability of the condensing surface. These two modes of condensation have disparate heat transfer coefficients, with dropwise often exceeding filmwise. This work reports a surface with switchable superhydrophilic to hydrophobic wetting behavior that can exhibit both modes of condensation. Relative to the highly-wetting state which yields filmwise condensation, the non-wetting state exhibits dropwise condensation and twice the heat transfer coefficient. Relevance to thermal management is additionally discussed.

Heat transfer↗

CFD Validation and Scaling of a Condenser Used in an ISRU Propellant Production System

This work develops a Computational Fluid Dynamics (CFD) model of a Commercial-Off-The-Shelf (COTS) condenser used for ground-based testing of an In-Situ Resource Utilization (ISRU) propellant production system. STAR-CCM+ was used to simulate water condensing through the condenser downstream of a methanation reactor. The computational data of the digital model is validated with test cases using nitrogen and water in ambient conditions. After validation with the test data, the digital model can be used to predict scale at higher production targets. The StarCCM+ simulation of the digital model shows good agreement with the test data provided. From the simulation, the condensation rate calculated was 18.3 g/hr and the process gas mass flow rate was 709.2 g/hr. The test data measured an average 16.9 g/hr condensation rate and 693.6 g/hr process gas mass flow rate. The simulation shows a 7.3% error in the water condensation and 2.2% error in the process gas at the outlet.

Condenser↗

Amphiphilic nanopores that condense undersaturated water vapor and exude water droplets

Condensation of water vapor in confined geometries, known as capillary condensation, is a fundamental phenomenon with far-reaching implications. While hydrophilic pores enable liquid formation from undersaturated vapor without energy input, the condensate typically remains confined, limiting practical utility. Here, we explore the use of amphiphilic nanoporous polymer-infiltrated nanoparticle films that condense and release liquid water under isothermal and undersaturated conditions. By tuning the polymer fraction and nanoparticle size, we optimize condensation and droplet formation. As vapor pressure increases, voids fill with condensate, which subsequently exudes onto the surface as microscopic droplets. This behavior, enabled by a balance of polymer hydrophobicity and capillarity, reveals how amphiphilic nanostructures can drive accessible water collection. Our findings provide design insights for materials supporting energy-efficient water harvesting and heat management without external input.

Science & Technology - Other Topics↗

Performance Evaluation of Low-Cost Condensers Immersed in the Water Tank of a Heat Pump Water Heater

This paper reports the effect of low-cost immersed condensers on the performance of a heat pump water heater (HPWH) that does not require a water-circulating pump. The proposed design is based on the immersion of an L-style condenser coil through an opening in the top of the water tank. The novel design aims to eliminate the need for the water-circulating pumps, thereby substantially improving efficiency and reducing costs and maintenance of the HPWH system. Comprehensive computational fluid dynamics (CFD) simulations and experimental tests were performed, and the results showed that the CFD simulations were close to the experimental data. Further results confirm that the L-style condenser can introduce buoyancy-driven flow and eliminate temperature stratification in the studied HPWH water tank, thereby improving the heat transfer coefficient and coefficient of performance of the HPWH. The testing results further showed that the L-style condenser enabled more than 53% higher coefficient of performance and 400% higher heat transfer coefficient compared with the straight vertical condenser, and achieved much faster water heating. Furthermore, the effects of immersed condensers with different circuits on the HPWH performance were evaluated and compared. All results indicate that the current energy-saving and inexpensive HPWH technology is technically valid, and the benefits of performance improvement and low cost are attractive in future HPWH design.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Disequilibrium condensation environments in space - A frontier in thermodynamics

The thermal-disequilibrium aspect of the problem of dust-particle formation from a gas phase in an open space environment is discussed in an effort to draw attention to the space condensation environment as an interesting arena for application and extension of the ideas and formalisms of nonequilibrium thermodynamics. It is shown that quasi-steady states with a disequilibrium between the gas-phase kinetic temperature and the condensed-phase internal temperature appear to be the norm of condensation environments in space. Consideration of the case of condensation onto a bulk condensed phase indicates that these quasi-steady states may constitute Prigogine dissipative structures. It is suggested that a proper study of the process of condensation in a space environment should include any effects arising from thermal disequilibrium.

De, B. R.↗

Development of a condenser for the dual catalyst water recovery system

Conceptual evaporation/condensation systems suitable for integration with the catalytic water recovery method were evaluated. The primary requirements for each concept were its capability to operate under zero-gravity conditions, condense recovered water from a vapor-noncondensable gas mixture, and integrate with the catalytic system. Specific energy requirements were estimated for concepts meeting the primary requirements, and the concept most suitable for integration with the catalytic system was proposed. A three-man rate condenser capable of integration with the proposed system, condensing water vapor in presence of noncondensables and transferring the heat of condensation to feed urine was designed, fabricated, and tested. It was treated with steam/air mixtures at atmospheric and elevated pressures and integrated with an actual catalytic water recovery system. The condenser has a condensation efficiency exceeding 90% and heat transfer rate of approximately 85% of theoretical value at coolant temperature ranging from 7 to 80 deg C.

Budinikas, P.↗

Condensation modes in sheared magnetic fields

The present study of the condensation modes in coronal cylindrical plasmas, with attention to magnetic shear effects on stability, notes that such shear is insignificant in the initiation of condensation in the case of low beta coronal plasmas. The effects of magnetic field shear, twist, and strength on condensation modes differ, depending on the wave vector. The stability of condensation modes strongly depends on the choice of equilibrium temperature and density profiles. If plasma temperature increases with twist but density does not, condensation modes are unstable for low field twist; by contrast, if plasma density increases with twist but temperature does not, condensation modes are unstable for high twist.

An, C.-H.↗

Study of toluene rotary fluid management device and shear flow condenser performance for a space-based organic Rankine power system

Management of two-phase fluid and control of the heat transfer process in microgravity is a technical challenge that must be addressed for an orbital Organic Rankine Cycle (ORC) application. A test program was performed in 1-g that satisfactorily demonstrated the two-phase management capability of the rotating fluid management device (RFMD) and shear-flow condenser. Operational tests of the RFMD and shear flow condenser in adverse gravity orientations, confirmed that the centrifugal forces in the RFMD and the shear forces in the condenser were capable of overcoming gravity forces. In a microgravity environment, these same forces would not have to compete against gravity and would therefore be dominant. The specific test program covered the required operating range of the Space Station Solar Dynamic Rankine Cycle power system. Review of the test data verified that: fluid was pumped from the RFMD in all attitudes; subcooled states in the condenser were achieved; condensate was pushed uphill against gravity; and noncondensible gases were swept through the condenser.

Havens, Vance↗

Mathematical Modeling of Loop Heat Pipes with Multiple Capillary Pumps and Multiple Condensers: Stead State Stimulations - Part 1

Loop Heat Pipes (LHPs) have proven themselves as reliable and robust heat transport devices for spacecraft thermal control systems. So far, the LHPs in earth-orbit satellites perform very well as expected. Conventional LHPs usually consist of a single capillary pump for heat acquisition and a single condenser for heat rejection. Multiple pump/multiple condenser LHPs have shown to function very well in ground testing. Nevertheless, the test results of a dual pump/condenser LHP also revealed that the dual LHP behaved in a complicated manner due to the interaction between the pumps and condensers. Thus it is redundant to say that more research is needed before they are ready for 0-g deployment. One research area that perhaps compels immediate attention is the analytical modeling of LHPs, particularly the transient phenomena. Modeling a single pump/single condenser LHP is difficult enough. Only a handful of computer codes are available for both steady state and transient simulations of conventional LHPs. No previous effort was made to develop an analytical model (or even a complete theory) to predict the operational behavior of the multiple pump/multiple condenser LHP systems. The current research project offered a basic theory of the multiple pump/multiple condenser LHP operation. From it, a computer code was developed to predict the LHP saturation temperature in accordance with the system operating and environmental conditions.

Hoang, Triem T.↗

Calculated Condenser Performance for a Mercury-Turbine Power Plant for Aircraft

As part of an investigation af the application of nuclear energy to various types of power plants for aircraft, calculations have been made to determine the effect of several operating conditions on the performance of condensers for mercury-turbine power plants. The analysis covered 8 range of turbine-outlet pressures from 1 to 200 pounds per square inch absolute, turbine-inlet pressures from 300 to 700 pounds per square inch absolute,and a range of condenser cooling-air pressure drops, airplane flight speeds, and altitudes. The maximum load-carrying capacity (available for the nuclear reactor, working fluid, and cargo) of a mercury-turbine powered aircraft would be about half the gross weight of the airplane at a flight speed of 509 miles per hour and an altitude of 30,000 feet. This maximum is obtained with specific condenser frontal areas of 0.0063 square foot per net thrust horsepower with the condenser in a nacelle and 0.0060 square foot per net thrust horsepower with the condenser submerged in the wings (no external condenser drag) for a turbine-inlet pressure of 500 pounds per square inch absolute, a turbine-outlet pressure of 10 pounds per square inch absolute, and 8 turbine-inlet temperature of 1600 F.

Doyle, Ronald B.↗

The Relationship Between Catalyst and Solvent in Hydrogenation via Condensed Phase Heterogeneous Catalysis

To understand a system is to understand its components and their sum. Cascading interactions between catalyst, solvent, and reagent create a complex web of influences when heterogeneous catalysis meets the condensed phase. Due to the importance of heterogeneous catalysis in chemical manufacturing, and the present and growing potential of condensed phase chemistries, the understanding of these interactions is of paramount importance. To develop condensed phase heterogeneous catalysis, the field needs to develop understanding of the role of solvent in heterogeneous catalytic hydrogenation. While no small feat, fields such as biofuel and petroleum refining have established certain applicable generalities that can bridge the knowledge gap in emerging technologies such as integrated carbon capture and conversion to materials (IC 3 M). In this review, we thoughtfully probe the current paradigm of condensed phase catalysis by challenging the idea that catalyst and solvent are independent reaction design choices. Challenges such as lack of experimental stability studies and poor resolution on our conceptualization of the condensed phase environment are discussed. Parameters such as viscosity and the dielectric constant, and their role on reaction activity and stability are explored. Knowledge gained from established biomass and petroleum processes is discussed and used to anticipate behavior in novel processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗