Thermal Management System for an Electric Machine with Additively Manufactured Hollow Conductors with Integrated Heat Pipes: Preprint

This paper discusses steps taken to size a thermal management system for an aircraft propulsion electric machine containing additively manufactured coils integrated with heat pipes aimed at boosting its specific power. Experimental setups are used to size and characterize heat pipes for the application and 3D thermal FEA is used to determine optimum heat transfer coefficient of convective boundaries. Geometric details of fin-based surface area enhancement required to reach target combined overall heat transfer coefficient (U) and surface area (A) performance (UA) in W/K, is worked out for relevant boundaries and the resulting UA is verified in 3D thermal FEA. Thermal management system's UA (by extension specific power) sensitivity to coolant temperature is explored and temperature distribution plots of optimized machine components are presented and discussed.

additive manufacturing↗

Amorphous Indium-Zinc-Oxide Transparent Conductors for Thin Film PV: Preprint

Amorphous InZnO's (a-IZO) basic PV applicability has now been demonstrated in prototype CIGS, Si Heterojunction (SiHJ) and organic photovoltaics (OPV). However, to move beyond initial demonstration devices, improved TCO properties and processibility of the a-IZO films are needed. Here, RF-superimposed DC sputtering was used to improve the reliable deposition of a-IZO with conductivity > 3000 S/cm.

14 SOLAR ENERGY↗

Testing of the 3M Company ACCR Conductor

The 3M Company has developed a high-temperature low-sag conductor referred to as Aluminum- Conductor Composite-Reinforced or ACCR. The conductor uses an aluminum metal matrix material to replace the steel in conventional conductors so the core has a lower density and higher conductivity. The objective of this work is to accelerate the commercial acceptance by electric utilities of these new conductor designs by testing four representative conductor classes in controlled conditions. Overhead transmission lines use bare aluminum conductor strands wrapped around a steel core strands to transmit electricity. The typical cable is referred to as aluminum-conductor steel-reinforced (ACSR). The outer strands are aluminum, chosen for its conductivity, low weight, and low cost. The center strand is of steel for the strength required to support the weight without stretching the aluminum due to its ductility. The power density of a transmission corridor has been directly increased by increasing the voltage level. Transmission voltages have increased from 115-kV to 765- kV over the past 80 years. In the United States, further increasing the voltage level is not feasible at this point in time, so in order to further increase the power density of a transmission corridor, conductor designs that increase the current carrying capability have been examined. One of the key limiting factors in the design of a transmission line is the conductor sag which determines the clearance of the conductor above ground or underlying structures needed for electrical safety. Increasing the current carrying capability of a conductor increases the joule heating in the conductor which increases the conductor sag. A conductor designed for high-temperature and lowsag operation requires an engineered modification of the conductor materials. To make an advanced cable, the 3M Company solution has been the development of a composite conductor consisting of Nextel ceramic fibers to replace the steel core and an aluminum-zirconium alloy to improve the outer strands. The result is a cable that can carry more current than steelaluminum lines without sagging as much at higher temperatures. A unique facility called the Powerline Conductor Accelerated Testing (PCAT) Facility was built at ORNL for testing overhead conductors. The PCAT has been uniquely designed for testing overhead bare transmission line conductors at high currents and temperatures after they have been installed and tensioned to the manufacturer's specifications. The ability to operate a transmission line conductor in this manner does not exist elsewhere in the United States. Four classes of ACCR cable designed by 3M have been successfully test at ORNL – small, medium, large and small/compact. Based on these and other manufacturer tests, the 3M Company has successfully introduced the ACCR into the commercial market and has completed over twenty installations for utility companies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Damage Evolution of Double-Sided Copper Conductor on Multi-layer Flexible Substrate Under Bending

Abstract—Thin-film conductors continue to play an important role in flexible electronics, and thus, the performance and reliability of such conductors under mechanical loading such as stretch, bend, and twist need to be studied through experiments as well as simulations. This paper focuses on the damage evolution of the thin-film conductors under cyclic bending. Four types of double-sided copper conductors: straight trace without coverlay, straight trace with coverlay, notched trace without coverlay, and notched trace with coverlay on multi-layer substrates were studied in this work. The adaptive curvature flexure test method, which is suitable for thin-film bending, was employed in this work. Adaptive curvature flexure test is one where the flexible substrate with its conductor is positioned between two parallel plates, and the parallel plates are moved relative to each other such that the gap distance between the parallel plates changes in one of the configurations of the adaptive curvature flexure test. Different strain levels can be achieved easily in such an adaptive curvature flexure test by controlling the gap distance between the parallel plates. By subjecting flexible substrates with thin conductors to such bend tests, the fatigue life of the specimen was determined for different magnitudes of strain ranges. The results were then compared among the four types of conductors. Specimens were designed such that the conductors were placed on both sides of the substrate so that the one of the conductors would undergo tensile straining, while the other one would undergo compressive straining. It was shown that the fatigue life was highly dependent on the magnitude of strain range, and that the conductor on the compressive side failed sooner than that on the tensile side. The failed specimens were examined in a microscope at different number of cycles. Also, the resistance of the conductors, which is directly related to the reliability of thin-film conductors, was monitored in-situ during bending. The resistance change with the strain range change as well as the resistance progression with the number of cycles in tensile as well as compressive mode were determined, and such information is then used to create failure prediction models for thin-film conductors on flexible substrates.

damage evolution, flexible conductor, multi-layer ↗

Sensitivity Effects of High Temperature Overhead Conductors to Line Rating Variables

For traditional overhead transmission lines, the maximum allowable conductor operating temperature on ASCR, AAC, or AAAC lines for determining the static line ratings can be quite low, typically well under 100 C. At these low temperatures, the primary driver for determining static line ratings are assumptions made about the wind speed and direction and the ambient temperature. Assumptions for solar loading and emitted thermal radiation, driven by line emissivity and absorptivity, are secondary factors, and only provide small changes to the static ratings. However, when considering newer high temperature conductors such as ACSS, ACCR, ZTACIR, and ACCC® the maximum allowable conductor temperatures can be significantly higher, up to 250° C. This higher temperature shifts the importance of the emissivity assumptions of the overhead transmission line, due to the nature of the T4 dependence of the radiative heat loss compared to the T1 dependence of the convective heat loss, as well as shifting the dependency on local wind conditions. Typical assumptions in the United States for the emissivity/absorptivity of overhead transmission lines in determining the static ratings are to use a value of 0.5 for both parameters or set a value in the range of 0.7 to 0.9. Recent experimental tests at EPRI have shown that higher emissivity aging assumptions may not be valid in some regions of the US, and that actual values may be much lower (0.25-0.45) than older studies have predicted (0.8-0.9). Here, the assumptions of different US Regional Transmission Operators (RTOs) and different utilities within RTOs are examined for the static ratings for traditional lower operating temperatures up to 100° C as well as with the higher maximum temperature conductors associated with newer conductor designs at 250° C. The sensitivity of the static ratings is examined at both lower and higher temperature conductors with respect to overhead line emissivity and absorptivity, wind speed, wind direction, and solar loading, and ambient temperature. It is shown that the effects of the conductor absorptivity, solar flux and ambient temperature on the static rating are increased when the transmission line has a lower maximum conductor temperature. The effects of the conductor emissivity, wind direction and wind speed have increased effects on the static rating when the transmission line has a higher maximum conductor temperature. In addition, example weather data is used to calculate the conductor temperature with different line emissivity and absorptivity assumptions. This shows the effect of assumptions made for emissivity only has a minor impact for low temperature lines, but for high temperature transmission lines can cause a 150-200° C temperature swing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Testing of the 3M Company Composite Conductor

The 3M Company has developed a high-temperature low-sag conductor referred to as Aluminum-Conductor Composite-Reinforced or ACCR. The conductor uses an aluminum metal matrix material to replace the steel in conventional conductors. The objective of this work is to accelerate the commercial acceptance by electric utilities of this new conductor design by testing four representative conductor classes in controlled conditions. A unique facility called the Powerline Conductor Accelerated Testing (PCAT) Facility was built at ORNL for testing overhead conductors. The PCAT has been uniquely designed for testing overhead bare transmission line conductors at high currents and temperatures after they have been installed and tensioned to the manufacturer's specifications. The ability to operate a transmission line conductor in this manner does not exist elsewhere in the United States. Four classes of ACCR cable designed by the 3M Company have been successfully test at ORNL small, medium, large and small/compact. Based on these and other manufacturer tests, the 3M Company has successfully introduced the ACCR into the commercial market and has completed over twenty installations for utility companies.

Kisner, Roger A.↗

Aluminum Ultra-conductors for Energy-Efficient Aerospace Busbar Applications (Abstract)

In this project, we will develop aluminum ultra-conductors with graphene additives demonstrating enhanced electrical conductivity at 90 °C compared to electric grade aluminum alloy AA1100 (43% IACS at 90 °C). While ultra-conductivity has been developed in copper and copper alloys, it is yet to be reported extensively in aluminum-based materials. This project will scale initial work done at PNNL on aluminum ultra-conductors using shear-assisted processing and extrusion (ShAPETM), a novel solid phase processing technique. Ultra-conductors are an emerging class of composites, comprised of a metal substrate with small quantities of nanocrystalline additives such as graphene or carbon nanotubes that demonstrate enhanced conductivity at relevant operating temperatures. Aluminum ultra-conductors can improve efficiency and power density while reducing the demand for copper in a wide range of applications, such as power transmission cables and electric motors. Busbars are an important component in aerospace systems that require lightweight and high-current power distribution including both future electric vertical take-off and landing (eVTOL) aircrafts and current aircraft electrical systems. We will accelerate aluminum ultra-conductor composite formulation development using combinatorial synthesis and testing methods aided by process/microstructure modeling, developed previously at PNNL. Eaton will test the properties of the ShAPE aluminum ultra-conductor feedstock (used to make the busbars) in relevant operating conditions (20 – 90 °C), predict the improvement in busbar performance when manufactured with ultra-conductors over commercial conductors (such as AA1100), and perform technoeconomic analysis to evaluate the potential for commercialization of ShAPE aluminum ultra-conductors. The project is expected to have a budget of $\$375$K, with $\$300$K in federal funding and $\$75$K in-kind cost-share contribution from Eaton over a period of performance of 24 months. Of the $\$300$K of federal funds, $\$140$K is allocated for CRADA activities that generate intellectual property (IP), and the remaining $\$160$K is reserved for modeling, material testing, characterization, travel, and reporting-related activities.

36 MATERIALS SCIENCE↗