Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

AbacusSummit Halo Light Cone Catalogs

This is a set of halo light cone catalogs from the AbacusSummit suite of cosmological N-body simulations (abacussummit.readthedocs.io/). They are a value-added data product provided by post-processing the simulation output. The main application of the halo light cone catalogs is the construction of realistic mock galaxy catalogues and weak lensing maps on the sky. The algorithm (described in Hadzhiyska et al. 2021) associates CompaSO halos from 29 redshift epochs spanning z = 0.1-2.5 with their particles at the time of light-cone crossing. It then records the halo and particle information into an easily accessible product, which can be read with the CompaSO reader. The 25 base resolution boxes at fiducial cosmology have a halo light cone catalog covering an octant of the sky to z approx 0.8 and about 2000 deg2 extending to z approx 2.4. The huge boxes provide light cone information of the full sky until z approx 2.18 and extend further towards the corners of the box (available until z = 2.25). Galaxy mock catalogs on the sky can be generated easily though the AbacusHOD script providing an extended HOD framework (see Yuan et al. 2021, for details), which has been modified to work with the halo light cone catalogs. The available tracers are luminous red galaxies (LRGs), emission-line galaxies (ELGs), and quasi-stellar objects (QSOs).

79 ASTRONOMY AND ASTROPHYSICS↗

Fast Electron Generation in Cones with Ultra-Intense Laser Pulses

Experimental results from copper cones irradiated with ultra-intense laser light are presented. Spatial images and total yields of Cu K{sub {alpha}} fluorescence were measured as a function of the laser focusing properties. The fluorescence emission extends into the cone approximately 300 {micro}m from the cone tip and cannot be explained by ray tracing including cone wall absorption. In addition the total fluorescence yield from cones is an order of magnitude higher than for equivalent mass foil targets. Indications are that the physics of the laser cone interaction is dominated by preplasma created from the long duration, low energy pre-pulse from the laser.

42 ENGINEERING↗

Evaluation of radiosurgery techniques–Cone-based linac radiosurgery vs tomotherapy-based radiosurgery

Performances of radiosurgery of intracranial lesions between cone-based Linac system and Tomotherapy-based system were compared in terms of dosimetry and time. Twelve patients with single intracranial lesion treated with cone-based Linac radiosurgery system from 2005 to 2009 were replanned for Tomotherapy-based radiosurgery treatment. The conformity index, homogeneity index (HI), and gradient score index (GSI) of each case was calculated. The Wilcoxon matched-pair test was used to compare the 3 indices between both systems. The cases with regular target (n = 6) and those with irregular target (n = 6) were further analyzed separately. The estimated treatment time between both systems was also compared. Significant differences were found in HI (p = 0.05) and in GSI (p = 0.03) for the whole group. Cone-based radiosurgery was better in GSI whereas Tomotherapy-based radiosurgery was better in HI. Cone-based radiosurgery was better in conformity index (p = 0.03) and GSI (p = 0.03) for regular targets, whereas Tomotherapy-based radiosurgery system performed significantly better in HI (p = 0.03) for irregular targets. The estimated total treatment time for Tomotherapy-based radiosurgery ranged from 24 minutes to 35 minutes, including 15 minutes of pretreatment megavoltage computed tomography (MVCT) and image registration, whereas that for cone-based radiosurgery ranged from 15 minutes for 1 isocenter to 75 minutes for 5 isocenters. As a rule of thumb, Tomotherapy-based radiosurgery system should be the first-line treatment for irregular lesions because of better dose homogeneity and shorter treatment time. Cone-based Linac radiosurgery system should be the treatment of choice for regular targets because of the better dose conformity, rapid dose fall-off, and reasonable treatment time.

61 RADIATION PROTECTION AND DOSIMETRY↗

Propagation of attosecond electron bunches along the cone-and-channel target

Generation and propagation of attosecond electron bunches along a cone-and-channel target are investigated by particle-in-cell simulation. The target electrons are pulled out by the oscillating electric field of an intense laser pulse irradiating a cone target and accelerated forward along the cone walls. It is shown that the energetic electrons can be further guided and confined by a channel attached to the cone tip. The propagation of these electrons along the channel induces a strong quasistatic magnetic field as well as a sheath electric field since a part of the energetic electrons expands into the surrounding vacuum. The electromagnetic field in turn confines the surface currents. With the cone-and-channel target the energetic electrons can be much better collimated and propagate much farther than that from the classical cone target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Initial cone-in-shell fast-ignition experiments on OMEGA

Fast ignition is a two-step inertial confinement fusion concept where megaelectron volt electrons ignite the compressed core of an imploded fuel capsule driven by a relatively low-implosion velocity. Initial surrogate cone-in-shell, fast-ignitor experiments using a highly shaped driver pulse to assemble a dense core in front of the cone tip were performed on the OMEGA/OMEGA EP Laser [T. R. Boehly et al., Opt. Commun. 133, 495 (1997); L. J. Waxer et al., Opt. Photonics News 16, 30 (2005)]. With optimal timing, the OMEGA EP pulse produced up to {approx}1.4 x 10{sup 7} additional neutrons which is a factor of {approx}4 more neutrons than without short-pulse heating. Shock-breakout measurements performed with the same targets and drive conditions demonstrate an intact cone tip at the time when the additional neutrons are produced. Velocity interferometer system for any reflector measurements show that x-rays from the shell's coronal plasma preheat the inner cone wall of thin-walled Au cones, while the thick-walled cones that are used in the integrated experiments are not affected by preheat.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of increased nanostructure cone growth on Cr due to grazing-incidence Ta seed atom deposition in a He plasma

Nanostructure cone growth on chromium during helium plasma exposure in the PISCES-A linear plasma device is found to increase with the deposition of heavy tantalum atoms. Tantalum is found to be especially effective at increasing cone growth if the tantalum is incident on the surface at a grazing angle (~5° or less). Tantalum atoms at grazing incidence are observed to be dominantly deposited at the cone tips, consistent with reduced sputtering of the cone tips and increased cone growth. Monte-Carlo simulations are found to be qualitatively consistent with the experimental observation that grazing-incidence heavy atom deposition on a lighter substrate will tend to increase cone growth.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TOWARD AN EMPIRICAL THEORY OF PULSAR EMISSION. IX. ON THE PECULIAR PROPERTIES AND GEOMETRIC REGULARITY OF LYNE AND MANCHESTER'S 'PARTIAL CONE' PULSARS

Lyne and Manchester identified a group of some 50 pulsars they called 'partial cones' which they found difficult to classify and interpret. They were notable for their asymmetric average profiles and asymmetric polarization position angle (PPA) traverses, wherein the steepest gradient (SG) point fell toward one edge of the total intensity profile. Over the last two decades, this population of pulsars has raised cautions regarding the core/cone model of the radio pulsar emission beam which implies a high degree of order, symmetry, and geometric regularity. In this paper, we reinvestigate this population 'partial cone' pulsars on the basis of new single pulse polarimetric observations of 39 of them, observed with the Giant Meterwave Radio Telescope in India and the Arecibo Observatory in Puerto Rico. These highly sensitive observations help us to establish that most of these 'partial cones' exhibit a core/cone structure just as did the 'normal' pulsars studied in the earlier papers of this series. In short, we find that many of these 'partial cones' are partial in the sense that the emission above different areas of their polar caps can be (highly) asymmetric. However, when studied closely we find that their emission geometries are overall identical to a core/double cone structure encountered earlier-that is, with specific conal dimensions scaling as the polar cap size. Further, the 'partial cone' population includes a number of stars with conal single profiles that are asymmetric at meter wavelengths for unknown reasons (e.g., like those of B0809+74 or B0943+10). We find that aberration-retardation appears to play a role in distorting the core/cone emission-beam structure in rapidly rotating pulsars. We also find several additional examples of highly polarized pre- and postcursor features that do not appear to be generated at low altitude but rather at high altitude, far from the usual polar flux tube emission sites of the core and conal radiation.

79 ASTRONOMY AND ASTROPHYSICS↗

MMTF DISCOVERY OF GIANT IONIZATION CONES IN MR 2251-178: IMPLICATIONS FOR QUASAR RADIATIVE FEEDBACK

We report the discovery of giant ionization cones in the 140 kpc nebula around quasar MR 2251-178 based on deep [O III] {lambda}5007/H{beta} and [N II] {lambda}6583/H{alpha} flux ratio maps obtained with the Maryland-Magellan Tunable Filter on the Baade-Magellan 6.5 m Telescope. These cones are aligned with the weak double-lobed radio source observed on smaller scale (<30 kpc). They have an opening angle {approx}120 Degree-Sign {+-} 10 Degree-Sign and subtend {approx}65%-90% of 4{pi} sr, where the uncertainty takes into account possible projection effects. The material in the outer ionization cones is matter-bounded, indicating that all ionizing photons emitted through the cones escape from the system. The quasar ionizing flux is {approx}2-3 times fainter outside of these cones, despite the largely symmetric geometry of the nebula in [O III]. Overall, adding up the contributions from both inside and outside the cones, we find that {approx}65%-95% of the quasar ionizing radiation makes its way out of the system. These results emphasize the need for line ratio maps to quantify the escape fraction of ionizing radiation from quasars and the importance of quasar radiative feedback on the intergalactic medium.

79 ASTRONOMY AND ASTROPHYSICS↗

Twelve inequivalent Dirac cones in two-dimensional ZrB 2

Theoretical evidence of the existence of 12 inequivalent Dirac cones at the vicinity of the Fermi energy in monolayered ZrB 2 is presented. Two-dimensional ZrB 2 is a mechanically stable d- and p-orbital compound exhibiting a unique electronic structure with two Dirac cones out of high-symmetry points in the irreducible Brillouin zone with a small electron-pocket compensation. First-principles calculations demonstrate that while one of the cones is insensitive to lattice expansion, the second cone vanishes for small perturbation of the vertical Zr position. Internal symmetry breaking with external physical stimuli, along with the relativistic effect of spin-orbit coupling, is able to remove selectively the Dirac cones. A rational explanation in terms of d- and p-orbital mixing is provided to elucidate the origin of the infrequent Dirac cones in a flat structure. In conclusion, the versatility of transition-metal d orbitals combined with the honeycomb lattice provided by the B atoms yields particular features in a two-dimensional material.

36 MATERIALS SCIENCE↗

Magnetic field induced antiferromagnetic cone structure in multiferroic BiFeO 3

Neutron diffraction measurements were performed under high magnetic fields up to 17 T in a multiferroic BiFeO 3 single crystal, in which an intermediate magnetic (IM) phase has been found between the cycloid and canted antiferromagnetic phases [S. Kawachi et al., Phys. Rev. Mater. 1, 024408 (2017)]. We clearly found that the incommensurate magnetic peaks, which split perpendicular to the magnetic field in the cycloid phase, rotate by 90 deg to align parallel to the field in the IM phase. The magnetic structure in the IM phase can be best described by an antiferromagnetic cone (AF cone) structure. The transition from the cycloid to AF cone is of first order and the direction of the magnetic wave vector and the easy plane of the cycloidal component are rotated by 90 deg without changing the cycloidal modulation period, whereas the transition from the AF cone to canted antiferromagnetic phase is gradual and the cone angle becomes smaller gradually without changing the modulation period. Interestingly, the cycloidal component as well as the cone angle in the IM phase shows a large hysteresis between the field increasing and decreasing processes. Finally, this result, combined with the magnetostriction with a large hysteresis previously reported in the IM phase, suggests a strong magnetoelastic coupling.

36 MATERIALS SCIENCE↗

High-resolution helical cone-beam micro-CT with theoretically-exact reconstruction from experimental data

Purpose: In this paper we show that optimization-based autofocus may be used to overcome the instabilities that have, until now, made high-resolution theoretically-exact tomographic reconstruction impractical. To our knowledge, this represents the first successful use of theoretically-exact reconstruction in helical micro computed tomography (micro-CT) imaging. We show that autofocus-corrected, theoretically-exact helical CT is a viable option for high-resolution micro-CT imaging at high cone-angles ({approx}50 deg.). The elevated cone-angle enables better utilization of the available X-ray flux and therefore shorter image acquisition time than conventional micro-CT systems. Methods: By using the theoretically-exact Katsevich 1PI inversion formula, we are not restricted to a low-cone-angle regime; we can in theory obtain artefact-free reconstructions from projection data acquired at arbitrary high cone-angles. However, this reconstruction method is sensitive to misalignments in the tomographic data, which result in geometric distortion and streaking artefacts. We use a parametric model to quantify the deviation between the actual acquisition trajectory and an ideal helix, and use an autofocus method to estimate the relevant parameters. We define optimal units for each parameter, and use these to ensure consistent alignment accuracy across different cone-angles and different magnification factors. The tomographic image is obtained from a set of virtual projections in which software correction for hardware misalignment has been applied. Results: We make significant modifications to the autofocus method that allow this method to be used in helical micro-CT reconstruction, and show that these developments enable theoretically-exact reconstruction from experimental data using the Katsevich 1PI (K1PI) inversion formula. We further demonstrate how autofocus-corrected, theoretically-exact helical CT reduces the image acquisition time by an order of magnitude compared to conventional circular scan micro-CT. Conclusions: Autofocus-corrected, theoretically-exact cone-beam reconstruction is a viable option for reducing acquisition time in high-resolution micro-CT imaging. It also opens up the possibility of efficiently imaging long objects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic cone beam CT angiography of carotid and cerebral arteries using canine model

Purpose: This research is designed to develop and evaluate a flat-panel detector-based dynamic cone beam CT system for dynamic angiography imaging, which is able to provide both dynamic functional information and dynamic anatomic information from one multirevolution cone beam CT scan. Methods: A dynamic cone beam CT scan acquired projections over four revolutions within a time window of 40 s after contrast agent injection through a femoral vein to cover the entire wash-in and wash-out phases. A dynamic cone beam CT reconstruction algorithm was utilized and a novel recovery method was developed to correct the time-enhancement curve of contrast flow. From the same data set, both projection-based subtraction and reconstruction-based subtraction approaches were utilized and compared to remove the background tissues and visualize the 3D vascular structure to provide the dynamic anatomic information. Results: Through computer simulations, the new recovery algorithm for dynamic time-enhancement curves was optimized and showed excellent accuracy to recover the actual contrast flow. Canine model experiments also indicated that the recovered time-enhancement curves from dynamic cone beam CT imaging agreed well with that of an IV-digital subtraction angiography (DSA) study. The dynamic vascular structures reconstructed using both projection-based subtraction and reconstruction-based subtraction were almost identical as the differences between them were comparable to the background noise level. At the enhancement peak, all the major carotid and cerebral arteries and the Circle of Willis could be clearly observed. Conclusions: The proposed dynamic cone beam CT approach can accurately recover the actual contrast flow, and dynamic anatomic imaging can be obtained with high isotropic 3D resolution. This approach is promising for diagnosis and treatment planning of vascular diseases and strokes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical Note: Suppression of artifacts arising from simultaneous cone-beam imaging and RF transponder tracking in prostate radiotherapy

Purpose: Artifacts in treatment-room cone-beam reconstructions have been observed at the authors' center when cone-beam acquisition is simultaneous with radio frequency (RF) transponder tracking using the Calypso 4D system (Calypso Medical, Seattle, WA). These artifacts manifest as CT-number modulations and increased CT-noise. The authors present a method for the suppression of the artifacts. Methods: The authors propose a three-stage postprocessing technique that can be applied to image volumes previously reconstructed by a cone-beam system. The stages are (1) segmentation of voxels into air, soft-tissue, and bone; (2) application of a 2D spatial-filter in the axial plane to the soft-tissue voxels; and (3) normalization to remove streaking along the axial-direction. The algorithm was tested on patient data acquired with Synergy XVI cone-beam CT systems (Elekta, Crawley, United Kingdom). Results: The computational demands of the suggested correction are small, taking less than 15 s per cone-beam reconstruction on a desktop PC. For a moderate loss of spatial-resolution, the artifacts are strongly suppressed and low-contrast visibility is improved. Conclusions: The correction technique proposed is fast and effective in removing the artifacts caused by simultaneous cone-beam imaging and RF-transponder tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Auto calibration of a cone-beam-CT

Purpose: This paper introduces a novel autocalibration method for cone-beam-CTs (CBCT) or flat-panel CTs, assuming a perfect rotation. The method is based on ellipse-fitting. Autocalibration refers to accurate recovery of the geometric alignment of a CBCT device from projection images alone, without any manual measurements. Methods: The authors use test objects containing small arbitrarily positioned radio-opaque markers. No information regarding the relative positions of the markers is used. In practice, the authors use three to eight metal ball bearings (diameter of 1 mm), e.g., positioned roughly in a vertical line such that their projection image curves on the detector preferably form large ellipses over the circular orbit. From this ellipse-to-curve mapping and also from its inversion the authors derive an explicit formula. Nonlinear optimization based on this mapping enables them to determine the six relevant parameters of the system up to the device rotation angle, which is sufficient to define the geometry of a CBCT-machine assuming a perfect rotational movement. These parameters also include out-of-plane rotations. The authors evaluate their method by simulation based on data used in two similar approaches [L. Smekal, M. Kachelriess, S. E, and K. Wa, 'Geometric misalignment and calibration in cone-beam tomography,' Med. Phys. 31(12), 3242-3266 (2004); K. Yang, A. L. C. Kwan, D. F. Miller, and J. M. Boone, 'A geometric calibration method for cone beam CT systems,' Med. Phys. 33(6), 1695-1706 (2006)]. This allows a direct comparison of accuracy. Furthermore, the authors present real-world 3D reconstructions of a dry human spine segment and an electronic device. The reconstructions were computed from projections taken with a commercial dental CBCT device having two different focus-to-detector distances that were both calibrated with their method. The authors compare their reconstruction with a reconstruction computed by the manufacturer of the CBCT device to demonstrate the achievable spatial resolution of their calibration procedure. Results: Compared to the results published in the most closely related work [K. Yang, A. L. C. Kwan, D. F. Miller, and J. M. Boone, 'A geometric calibration method for cone beam CT systems,' Med. Phys. 33(6), 1695-1706 (2006)], the simulation proved the greater accuracy of their method, as well as a lower standard deviation of roughly 1 order of magnitude. When compared to another similar approach [L. Smekal, M. Kachelriess, S. E, and K. Wa, 'Geometric misalignment and calibration in cone-beam tomography,' Med. Phys. 31(12), 3242-3266 (2004)], their results were roughly of the same order of accuracy. Their analysis revealed that the method is capable of sufficiently calibrating out-of-plane angles in cases of larger cone angles when neglecting these angles negatively affects the reconstruction. Fine details in the 3D reconstruction of the spine segment and an electronic device indicate a high geometric calibration accuracy and the capability to produce state-of-the-art reconstructions. Conclusions: The method introduced here makes no requirements on the accuracy of the test object. In contrast to many previous autocalibration methods their approach also includes out-of-plane rotations of the detector. Although assuming a perfect rotation, the method seems to be sufficiently accurate for a commercial CBCT scanner. For devices which require higher dimensional geometry models, the method could be used as a initial calibration procedure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cone beam x-ray luminescence computed tomography: A feasibility study

Purpose: The appearance of x-ray luminescence computed tomography (XLCT) opens new possibilities to perform molecular imaging by x ray. In the previous XLCT system, the sample was irradiated by a sequence of narrow x-ray beams and the x-ray luminescence was measured by a highly sensitive charge coupled device (CCD) camera. This resulted in a relatively long sampling time and relatively low utilization of the x-ray beam. In this paper, a novel cone beam x-ray luminescence computed tomography strategy is proposed, which can fully utilize the x-ray dose and shorten the scanning time. The imaging model and reconstruction method are described. The validity of the imaging strategy has been studied in this paper. Methods: In the cone beam XLCT system, the cone beam x ray was adopted to illuminate the sample and a highly sensitive CCD camera was utilized to acquire luminescent photons emitted from the sample. Photons scattering in biological tissues makes it an ill-posed problem to reconstruct the 3D distribution of the x-ray luminescent sample in the cone beam XLCT. In order to overcome this issue, the authors used the diffusion approximation model to describe the photon propagation in tissues, and employed the sparse regularization method for reconstruction. An incomplete variables truncated conjugate gradient method and permissible region strategy were used for reconstruction. Meanwhile, traditional x-ray CT imaging could also be performed in this system. The x-ray attenuation effect has been considered in their imaging model, which is helpful in improving the reconstruction accuracy. Results: First, simulation experiments with cylinder phantoms were carried out to illustrate the validity of the proposed compensated method. The experimental results showed that the location error of the compensated algorithm was smaller than that of the uncompensated method. The permissible region strategy was applied and reduced the reconstruction error to less than 2 mm. The robustness and stability were then evaluated from different view numbers, different regularization parameters, different measurement noise levels, and optical parameters mismatch. The reconstruction results showed that the settings had a small effect on the reconstruction. The nonhomogeneous phantom simulation was also carried out to simulate a more complex experimental situation and evaluated their proposed method. Second, the physical cylinder phantom experiments further showed similar results in their prototype XLCT system. With the discussion of the above experiments, it was shown that the proposed method is feasible to the general case and actual experiments. Conclusions: Utilizing numerical simulation and physical experiments, the authors demonstrated the validity of the new cone beam XLCT method. Furthermore, compared with the previous narrow beam XLCT, the cone beam XLCT could more fully utilize the x-ray dose and the scanning time would be shortened greatly. The study of both simulation experiments and physical phantom experiments indicated that the proposed method was feasible to the general case and actual experiments.

60 APPLIED LIFE SCIENCES↗

SU-E-J-109: Testing the KV Imaging Center Congruence with Radiation Isocenter of Small MLC and SRS Cone Field On Two Machines

Purpose: Orthogonal kV image pairs are used for target localization when fiducial markers are implanted. CBCT is used to verify cone SRS setup. Therefore it is necessary to evaluate the isocenter congruence between radiation fields and kV imaging center. This study used a simple method to evaluate the isocenter congruence, and compared the results for MLC and cone fields on two different Linacs. Methods: Varian OBI block was attached on the couch. It has a central 1mm BB with markers on three surfaces to align with laser. KV and MV images were taken at four cardinal angles. A 3x3cm2 MLC field and a 20mm cone field were irradiated respectively. On each kV image, the distance from BB center to the kV graticule center were measured. On the MV image of MLC field, the center of radiation field was determined manually, while for cone field, the Varian AM maintenance software was used to analyze the distance between BB and radiation field. The subtraction of the two distances gives the discrepancy between kV and radiation centers. Each procedure was repeated on five days at Trilogy and TrueBeam respectively. Results: The maximum discrepancy was found in the longitudinal direction at 180° gantry angel. It was 1.5±0.1mm for Trilogy and 0.6±0.1mm for TrueBeam. For Trilogy, although radiation center wobbled only 0.7mm and image center wobbled 0.8mm, they wobbled to the opposite direction. KV Pair using gantry 180° should be avoided in this case. Cone vs. kV isocenter has less discrepancy than MLC for Trilogy. Conclusion: Radiation isocenter of MLC and cone field is different, so is between Trilogy and TrueBeam. The method is simple and reproducible to check kV and radiation isocenter congruence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bright and durable field emission source derived from refractory taylor cones

A method of producing field emitters having improved brightness and durability relying on the creation of a liquid Taylor cone from electrically conductive materials having high melting points. The method calls for melting the end of a wire substrate with a focused laser beam, while imposing a high positive potential on the material. The resulting molten Taylor cone is subsequently rapidly quenched by cessation of the laser power. Rapid quenching is facilitated in large part by radiative cooling, resulting in structures having characteristics closely matching that of the original liquid Taylor cone. Frozen Taylor cones thus obtained yield desirable tip end forms for field emission sources in electron beam applications. Regeneration of the frozen Taylor cones in-situ is readily accomplished by repeating the initial formation procedures. The high temperature liquid Taylor cones can also be employed as bright ion sources with chemical elements previously considered impractical to implement.

36 MATERIALS SCIENCE↗

Techniques for optimizing nanotips derived from frozen taylor cones

Optimization techniques are disclosed for producing sharp and stable tips/nanotips relying on liquid Taylor cones created from electrically conductive materials with high melting points. A wire substrate of such a material with a preform end in the shape of a regular or concave cone, is first melted with a focused laser beam. Under the influence of a high positive potential, a Taylor cone in a liquid/molten state is formed at that end. The cone is then quenched upon cessation of the laser power, thus freezing the Taylor cone. The tip of the frozen Taylor cone is reheated by the laser to allow its precise localized melting and shaping. Tips thus obtained yield desirable end-forms suitable as electron field emission sources for a variety of applications. In-situ regeneration of the tip is readily accomplished. These tips can also be employed as regenerable bright ion sources using field ionization/desorption of introduced chemical species.

36 MATERIALS SCIENCE↗