Search NASASearch

SEARCH · Search NASA

Results for “CORROSION RESISTANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Adhesive bonding and the use of corrosion resistant primers

The use of an anti-corrosive primer has been shown to be essential to assure survival of a bonded structure in a hostile environment, particularly if a stress is to be applied to the adhesively bonded joint during the environmental exposure. For example, the Lockheed L-1011 TriStar assembly, after exhaustive evaluation tests specifies use of chromate filled inhibitive polysulfide sealants, and use of corrosion inhibiting adhesive primers prior to structural bonding with film adhesive.

Hockridge, R. R.

Corrosion-resistant ceramic thermal barrier coating

Two-layer thermal barrier coating, consisting of metal-CrA1Y bond coating and calcium silicate ceramic outer layer, greatly improves resistance of turbine parts to hot corrosion from fuel and air impurities. Both layers can be plasma sprayed, and ceramic layer may be polished to reduce frictional losses. Ceramic provides thermal barrier, so parts operate cooler metal temperatures, coolant flow can be reduced, or gas temperatures increased. Lower grade fuels also can be used.

Hodge, P. E.

Corrosion-Resistant Ball Bearings

Self-lubricating bearing system withstands highly corrosive environment of wastewater-recycling unit. New bearings contain cobalt-based-alloy balls and races, graphite/polyimide polymer ball cages, and single integral polytetrafluoroethylene seals on wet sides. Materials and design prevent corrosion by acids and provide lubrication.

Zdankiewicz, E. M.

Wide-temperature corrosion-resistant pressure regulator

Simplified design and all-metal-and-ceramic-components make pressure regulator compatible with corrosive fluids such as fluorine and hydrazine, and extends operating-temperature range. Flexure guidance eliminates hysteresis and friction, and self-generated contaminations are diminished enough to produce nearly unlimited maintenance-free lifetime.

Wichmann, H.

Corrosion resistance of sodium sulfate coated cobalt-chromium-aluminum alloys at 900 C, 1000 C, and 1100 C

The corrosion of sodium sulfate coated cobalt alloys was measured and the results compared to the cyclic oxidation of alloys with the same composition, and to the hot corrosion of compositionally equivalent nickel-base alloys. Cobalt alloys with sufficient aluminum content to form aluminum containing scales corrode less than their nickel-base counterparts. The cobalt alloys with lower aluminum levels form CoO scales and corrode more than their nickel-base counterparts which form NiO scales.

Santoro, G. J.

Characterization of the corrosion resistance of several alloys to dilute biologically active solutions

Sulfate reducing bacteria and acid producing bacteria/fungi detected in hygiene waters increased the corrosion rate in aluminum alloy. Biologically active media enhanced the formation of pits on metal coupons. Direct observation of gas evolved at the corrosion sample, coupled with scanning electron microscopy (SEM) and energy dispersive x-ray analysis of the corrosion products indicates that the corrosion rate is increased because the presence of bacteria favor the reduction of hydrogen as the cathodic reaction through the reaction of oxygen and water. SEM verifies the presence of microbes in a biofilm on the surface of corroding samples. The bacterial consortia are associated with anodic sites on the metal surface, aggressive pitting occurs adjacent to biofilms. Many pits are associated with triple points and inclusions in the aluminum alloy microstructure. Similar bacterial colonization was found on the stainless steel samples. Fourier transform Infrared Spectroscopy confirmed the presence of carbonyl groups in pitted areas of samples exposed to biologically active waters.

Walsh, Daniel W.

The stress corrosion resistance and the cryogenic temperature mechanical properties of annealed Nitronic 60 bar material

Ambient and cryogenic temperature mechanical properties and the ambient temperature stress corrosion properties of annealed, straightened, and centerless ground Nitronic 60 stainless steel alloy bar material are presented. The mechanical properties of longitudinal specimens were evaluated at test temperatures from ambient to liquid hydrogen. The tensile test data indicated increasing strength with decreasing temperature to -196 C. Below liquid nitrogen temperature the smooth tensile and notched tensile strengths decreased slightly while the elongation and reduction of area decreased drastically. The Charpy V-notched impact energy decreased steadily with decreasing test temperature. Stress corrosion tests were performed on longitudinal tensile specimens and transverse C-ring specimens exposed to: alternate immersion in a 3.5% NaCl bath; humidity cabinet; and a 5% salt spray atmosphere. The longitudinal tensile specimens experienced no corrosive attack. Approximately 3/4 of the transverse C-rings exposed to alternate immersion and to salt spray experienced a pitting attack on the top and bottom ends. Additional stress corrosion tests were performed on transverse tensile specimens. No failures occurred in the 90% stressed specimens exposed for 90 days in the alternate immersion and salt spray environments

Montano, J. W. L.

The stress corrosion resistance and the cryogenic temperature mechanical properties of hot rolled Nitronic 32 bar material

The ambient and cryogenic temperature mechanical properties and the ambient temperature stress corrosion properties of hot rolled and centerless ground Nitronic 32 stainless steel bar material are presented. The mechanical properties of longitudinal specimens were evaluated at test temperatures from ambient to liquid hydrogen. The tensile test data indicated increasing smooth tensile strength with decreasing temperature to liquid hydrogen temperature. However, below -200 F (-129.0 C) the notched tensile strength decreased slightly and below -320 F (-196.0 C) the decrease was significant. The elongation and reduction of area decreased drastically at temperatures below -200 F (-129.0 C). The Charpy V-notched impact energy decreased steadily with decreasing test temperature. Stress corrosion tests were performed on longitudinal tensile specimens stressed to 0, 75, and 90 percent of the 0.2 percent yield strength and on transverse 'C'-ring specimens stressed to 75 and 90 percent of the yield strength and exposed to: alternate immersion in a 3.5 percent NaCl bath, humidity cabinet environment, and a 5 percent salt spray atmosphere. The longitudinal tensile specimens experienced no corrosive attack; however, the 'C'-rings exposed to the alternate immersion and to the salt spray experienced some shallow etching and pitting, respectively. Small cracks appeared in two of the 'C'-rings after one month exposure to the salt spray.

Montano, J. W. L.

The Stress Corrosion Resistance and the Cryogenic Temperature Mechanical Behavior of 18-3 Mn (Nitronic 33) Stainless Steel Parent and Welded Material

The ambient and cryogenic temperature mechanical properties and the ambient temperature stress corrosion results of 18-3 Mn (Nitronic 33)stainless steel, longitudinal and transverse, as received and as welded (TIG) material specimens manufactured from 0.063 inch thick sheet material, were described. The tensile test results indicate an increase in ultimate tensile and yield strengths with decreasing temperature. The elongation remained fairly constant to -200 F, but below that temperature the elongation decreased to less than 6.0% at liquid hydrogen temperature. The notched tensile strength (NTS) for the parent metal increased with decreasing temperature to liquid nitrogen temperature. Below -320 F the NTS decreased rapidly. The notched/unnotched (N/U) tensile ratio of the parent material specimens remained above 0.9 from ambient to -200 F, and decreased to approximately 0.65 and 0.62, respectively, for the longitudinal and transverse directions at liquid hydrogen temperature. After 180 days of testing, only those specimens exposed to the salt spray indicated pitting and some degradation of mechanical properties.

Montano, J. W.

Monitoring the corrosion resistance of cold-spray coatings with membrane-based sensors

In this presentation, the MBES shows the ability to detect the change in exposed environment even with cold-spray coatings. Corrosion rates from the cold-spray coating were comparable to a 316 stainless steel sample. Defects in the coating did not impact sensor performance in terms of corrosion rate or water content detection. Energy dispersive X-ray spectroscopy was used to document ion migration into the membrane.

Rendon, Arnaldo

Preliminary Design and Testing of Candidate Coating Materials Applied to Inconel Bubblers for Improved Corrosion Resistance

The US Department of Energy (DOE) Office of Environmental Management Technology Development (EM-TD) has requested Savannah River National Laboratory (SRNL) evaluate ceramic coating materials that can extend the service life of Hanford melter bubblers. The proposed Task will focus on the development of ceramic coating materials for Inconel bubblers to reduce corrosion and increase the service life of the bubblers.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Fabrication and Testing of Solid-Solution Strengthened Corrosion Resistant Alloys For Service in Molten Fluoride Environments

The demand for higher system thermal efficiencies requires the operation of power generation cycles and heat conversion systems at progressively higher temperatures. As the system operating temperature increases, existing materials may not provide adequate mechanical properties or environmental compatibility or both. There is an increasing commercial interest in the development and deployment of liquid-fueled Molten Salt Reactors (MSRs). Hastelloy®N, the highest performing candidate MSR structural alloy, is not capable of operations at temperatures above 700°C, thus limiting the performance of these systems. Using an Integrated Computational Materials Engineering (ICME)-approach and small laboratory scale heats, ORNL developed a class of patented alloys covered by U.S. Patent 9, 435, 011 B2, “Creep-resistant, Cobalt-free alloys for high temperature, liquid-salt heat exchanger systems,” similar to Hastelloy®N in that they are primarily solid solution strengthened. In contrast to precipitation strengthened alloys, the microstructure of solid solution alloys and hence the high temperature mechanical properties are stable for extended periods of time allowing long reactor operating life. The new alloys have shown to possess good resistance to liquid fluorides at temperatures up to 850°C and have significantly improved creep properties when compared to Hastelloy®N. The purpose of the CRADA project was for ORNL to collaborate with Haynes International- a materials producer, MetalTek International- a foundry, and Kairos Power – an advanced reactor developer – to scale-up selected alloys, evaluate their properties, and identify one solid solution strengthened alloy that can meet the property requirements for the reactor being developed by Kairos Power and other similar liquid fluoride-salt cooled reactors. As part of the project, eight alloys were down-selected and fabricated in larger industrial scale heats by Haynes International. Resistance to molten salt was evaluated in flowing FLiNaK and FLiBe by Kairos Power using their Rotating Cage Loop (RCL) system. Accounting for iron deposition during these tests, the new alloys displayed very low net mass change showing excellent corrosion performance in molten salt. Creep properties evaluated at ORNL were found to be better than that of Hastelloy®N and 316 stainless steel. Long-term stabilities of the alloys evaluated by Haynes International showed that these alloys have excellent thermal stability in the temperature range 704.4-815.6°C, with the change in strength and ductility being less than 10-15% after a 4000-hour exposure at 815.6°C. Autogenously Gas Tungsten Arc Welding (GTAW) welded samples showed less than 10% change in yield strength / ultimate tensile strength / total elongation compared to the basemetal, indicating that the alloys have excellent weldability. Three parts were successfully investment-cast using one alloy with very little voiding showing feasibility of fabricating parts using the casting process. This project enabled extensive interaction between the material producer Haynes International, casting supplier MetalTek, and reactor developer Kairos Power. This facilitated testing of materials and components produced using the newly developed alloys by the end-user. This allowed the generation of critical dataset required for down-selection of a few promising alloys for further development. This data is also currently being shared with other reactor designers for them to evaluate the suitability of this alloy for their reactor design. The availability of this alloy will ultimately enable the design and development and deployment of MSRs with increased temperature of operation and thus, improved efficiencies.

99 GENERAL AND MISCELLANEOUS