Search NASA⌕ Search

SEARCH · Search NASA

Results for “COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Average-passage simulation of counter-rotating propfan propulsion systems as applied to cruise missiles

Counter-rotating propfan (CRP) propulsion technologies are currently being evaluated as cruise missile propulsion systems. The aerodynamic integration concerns associated with this application are being addressed through the computational modeling of the missile body-propfan flowfield interactions. The work described in this paper consists of a detailed analysis of the aerodynamic interactions between the control surfaces and the propfan blades through the solution of the average-passage equation system. Two baseline configurations were studied, the control fins mounted forward of the counter-rotating propeller and the control fins mounted aft of the counter-rotating propeller. In both cases, control fin-propfan separation distance and control fin deflection angle were varied.

Mulac, Richard A.↗

Proportional counters as low energy photon detectors

We investigated the response of an argon-methane proportional counter to monochromatic X-rays in the range 99 to 277 eV. The apparent nonlinearities in mean pulse height as a function of photon energy and the detailed shape of the pulse height distribution for each energy can be predicted quite precisely using the extensive atomic data available for argon. Based on this understanding, we propose a semi-empirical system for using a limited amount of calibration data to predict the full response of counters employing less well-characterized gases. Such accurate models of proportional counters are required to maximize the spectral information that can be derived from observed pulse height distributions.

Jahoda, Keith↗

Counter-balanced, multiple cable construction crane

The invention is a counter-balanced, multiple cable construction crane. The apparatus for hoisting payloads comprises a crane having a lifting means, the lifting means comprising an end effector means and three suspension means or cables. One end of each cable attaches to a different winding means located on the lifting means, and the other end of each cable attaches to a different point on the end effector, such that the three cables have a theoretical point of convergence with this point corresponding to the center of mass of the payload. Three controls command rotation of the winding means to a predetermined position. Accordingly, the crane provides precise and autonomous positioning of the payload without human guidance. The crane further comprises a counter-balancing means. Two controls position the counter-balancing means to offset the overturning moment which arises during the lifting of heavy payloads.

Mikulas, Martin M., Jr.↗

Imaging Gas Counters for X- and Gamma Ray Astronomy

Gas-filled detectors, such as proportional counters, have long been used in x-ray astronomy. They are robust, relatively easy to fabricate, and can provide large collecting areas with reasonable spatial and energy resolution. Despite coming of age in the 50's and 60's, their versatility is such that they are still planned for future missions. A vigorous development program, led mostly by the high energy physics community, has ensured continued improvements in proportional counter technology. These include multistep counters, microstrip technologies and optical avalanche chambers. High fill-gas pressures and the use of suitable converters permit operation up to 100s of GeV. The current status of imaging gas-filled detectors will be reviewed, concentrating on the lower energy region (less than 100 keV) but also briefly covering higher energy applications up to the GeV region. This review is not intended to be exhaustive and draws heavily on work currently in progress at MSFC.

Ramsey, Brian D.↗

A LiF silicon sandwich counter to measure water content of planetary surfaces

The neutron counter proposed here has a long history and was commercially available in a somewhat different form. This counter would be suitable for a rover or lander since it requires a rather long measuring time for each placement. It consists of two silicon wafer charged-particle counters with a layer of Li-6F deposited on the inner surface of one. The neutron detecting reaction is Li-6(n,H-3)He-4 in which the alpha particle and the triton are emitted from the Li-6 deposit back to back. If one of the detectors sees the alpha particle, the other will see the triton. This allows one to use a coincidence technique that virtually eliminates all background. The signals from each detector can be added together so that the total energy of the reaction, Q=4.6 MeV and the kinetic energy of the neutron, can be recorded.

Drake, D. M.↗

Wingtip mounted, counter-rotating proprotor for tiltwing aircraft

A tiltwing aircraft, capable of in-flight conversion between a hover and forward cruise mode, employs a counter-rotating proprotor arrangement which permits a significantly increased cruise efficiency without sacrificing either the size of the conversion envelope or the wing efficiency. A benefit in hover is also provided because of the lower effective disk loading for the counter-rotating proprotor, as opposed to a single rotation proprotor of the same diameter. At least one proprotor is provided on each wing section, preferably mounted on the wingtip, with each proprotor having two counter-rotating blade rows. Each blade row has a plurality of blades which are relatively stiff-in-plane and are mounted such that cyclic pitch adjustments may be made for hover control during flight.

Wechsler, James K.↗

Counter-propagating toroidal Alfvén eigenmodes in tokamaks

Mechanisms of destabilization of toroidal Alfvén eigenmodes (TAEs) in tokamaks are analyzed with the aim to reveal those leading to modes propagating in the direction opposite to plasma current, i.e. counter-propagating modes (ctr-TAE). Plasmas with fast-ions sources [such as neutral beam injection (NBI), ion cyclotron resonance heating, fusion reactions] and without them (Ohmic discharges) are considered. A particular NSTX-U experiment with NBI, where co- and counter-propagating TAEs were observed simultaneously (Podestà et al 2018 Nucl. Fusion 58 082023), is considered. It is concluded that both types of TAEs occurred because their destabilization was caused by the velocity anisotropy of beam ions, which overrode effects of spatial inhomogeneity of these ions.

Alfvénic instabilities↗

Preferential adsorption of noble gases in zeolitic tuff with variable saturation: A modeling study of counter-intuitive diffusive-adsorptive behavior

Noble gas transport through geologic media has important applications in the prediction and characterization of measured gas signatures related to underground nuclear explosions (UNEs). Retarding processes such as adsorption can cause significant species fractionation of radionuclide gases, which has implications for measured and predicted signatures used to distinguish radioxenon originating from civilian nuclear facilities or from UNEs. Accounting for the effects of variable water saturation in geologic media on tracer transport is one of the most challenging aspects of modeling gas transport because there is no unifying relationship for the associated tortuosity changes between different rock types, and reactive transport processes such as adsorption that are affected by the presence of water likewise behave differently between gas species. In this study, we perform numerical diffusive-adsorptive transport simulations to estimate gas transport parameters associated with bench-scale laboratory diffusion cell experiments measuring breakthrough in zeolitic and non-zeolitic rocks for a gaseous mixture of xenon, krypton, and SF 6 at varying degrees of water saturation (S w ). Counter-intuitive transport behavior was observed in the zeolitic rock experiments whereby breakthrough concentrations were significantly higher when the core was partially saturated (S w = 17 %) than under dry (S w = 0 %) conditions. Breakthrough of xenon was especially retarded in the dry core – likely due to comparatively high affinity of xenon for zeolitic adsorption sites – and estimated effective diffusion coefficients for all gases were approximately an order of magnitude lower than what is predicted by porosity-tortuosity models. We propose the counter-intuitive behavior observed is because water infiltration of zeolite nanopores reduces both the adsorptive capacity of the rock and the tortuosity of connected flow paths. We developed a two-site competitive kinetic Langmuir adsorption reaction for the porous media transport simulator in order to constrain transport parameters within zeolitic tuff, where differential adsorption to zeolite and non-zeolite pores was observed. We determined that liquid saturation-dependent diffusive-adsorptive transport is affected by subtle and at times competing processes that are specific to different gases, which have a significant overall influence on effective transport parameters.

58 GEOSCIENCES↗

Quantum-Enhanced Sensing of Axion Dark Matter with a Transmon-Based Single Microwave Photon Counter

We report an axion dark matter search with a haloscope equipped with a microwave photon counter. The haloscope is a tunable high quality factor three-dimensional microwave cavity placed in a magnetic field. The photon counter, operated cyclically, maps an incoming microwave photon onto the state of a superconducting transmon qubit. The measurement protocol continuously monitors the power emitted by the haloscope cavity as well as the dark count background and enables tuning of the cavity frequency to probe different axion masses. With this apparatus, we enhance by a factor of 20 the search speed that can be reached with quantum-limited linear amplifiers and set a new standard for probing the existence of axions with resonant detectors above 5 GHz. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MC-Lite: Development of a new lightweight multiplicity counter

This report details the development of a neutron multiplicity counter based on lithium doped plastic scintillators. This system has the capability to measure and discriminate fast neutrons, thermal neutrons, and gamma-rays allowing for multi-particle correlations in one device. The system was built and tested at Lawrence Livermore National Laboratory with Cf-252 in both bare configurations and surrounded by polyethylene and compared against the MC-15 multiplicity counter. Additionally, the detector was also placed outside of a subcritical assembly and demonstrated the ability to use correlated gamma-rays as a probe on the multiplication of the item.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Report: Multi-Instrument Comparison of AAF Condensation Particle Counters

Condensation particle counters (CPCs), also known as condensation nucleus counters (CNCs) are sophisticated instruments designed to measure the concentration of aerosol particles in the atmosphere. These devices are pivotal in environmental monitoring, industrial applications, and scientific research, particularly in atmospheric studies. CPCs are vital for understanding the role of aerosols in climate systems. Aerosols influence cloud formation, radiative forcing, and atmospheric chemistry. By providing accurate measurements of particle concentrations and distributions, CPCs contribute to models that predict atmospheric impact and weather patterns (Mei et al. 2021). CPCs operate by enlarging submicron particles, including those as small as a few nanometers, to sizes detectable by optical methods. This report delves into the mechanisms, importance, and contributions of CPCs to atmospheric research at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Aerial Facility (AAF), highlighting their role in advancing air quality assessment, pollution control, and atmospheric studies.

54 ENVIRONMENTAL SCIENCES↗

HIGHER EFFICIENCY FISSION COUNTER FOR NEUTRON DETECTION

Fission chambers containing 235U have been used for detection of neutrons for many decades. In these chambers 235U is electroplated on a metal which is one plate of an ionization chamber. Since the range of fission products from induced fission in the chamber is extremely short, these deposits from electroplating are so thin that the amount of 235U results in low neutron detection efficiency and the chamber needs high internal 235U surface area to increase efficiency. A typical ~8 in. long, ~2 in. diameter fission counter only contains < 2 g of 235U total, resulting in very low detection efficiency per incident neutron impinging on the outer surface of the detector. However, because of their large electronic pulses from fission products compared to gamma rays it is very easy to discriminate against gamma rays impinging on the detector. These types of chambers are produced commercially and are used worldwide in nuclear research and nuclear power reactors. ORNL has made a higher efficiency fission ionization chamber by using many thin concentric annuli to increase the area. A higher efficiency fission counter would be useful and can be made by incorporating 235U into a glass or ceramic scintillator. For nearly 100 years the green color in antique glass was produced by incorporation of depleted uranium (up to 20 wt. %) into a glass. The concept for this scintillation-optical-based fission detector is to dope a scintillator (either ceramic or glass) with 235U. Glass scintillators are commercially available doped with as much as 8 wt. % 6Li for neutron detection. In the 235U doped scintillator the fission product pulses would be double the size of those in an ion chamber since all fission products produce light in the scintillator whereas in the ionization chamber half do not go into the ionizing gas volume. These higher efficiency fission chambers would be very useful for a wide variety of research, nuclear research, and nuclear power reactor applications. Because of their smaller size and weight, they should be useful for space application such as monitoring of space nuclear power reactors. This report reviews existing fission chamber technology and suggests the development of these small high-efficiency fission chambers. Other fission isotopes could be used for other research applications.

Mihalczo, John [ORNL] (ORCID:0000000254292681)↗

Binary counter accumulates time by complementary preset

Binary counter reduces the number of logic elements required to furnish electrical control functions. The counter is automatically preset to the complement of the desired time increments in milliseconds. An output pulse is produced each time it reaches its capacity.

Marriner, G. E.↗

Four pi-recoil proportional counter used as neutron spectrometer

Study considers problems encountered in using 4 pi-recoil counters for neutron spectra measurement. Emphasis is placed on calibration, shape discrimination, variation of W, the average energy loss per ion pair, and the effects of differentiation on the intrinsic counter resolution.

Bennett, E. F.↗

Pental circuit may be used in conversionless decimal counter

Pental counter circuit, a five-stage ring of NOR gates, is used with a standard flip-flop and several AND gates to construct a decimal counter. Pental circuit eliminates the conversion circuitry which is used when binary circuits generate numeric information.

Galvin, D. H., Jr.↗

Complementary-MOS binary counter with parallel-set inputs

Metal oxide semiconductor four-stage binary counter contains reset capability as well as four parallel-set inputs gated in by a logic signal. Parallel-set inputs permit setting the counter into any of sixteen possible states.

Keller, K. R.↗

Inexpensive automatic ranging for digital voltmeters and frequency counters

Seven integrated circuits incorporated at very low cost into frequency counters and digital voltmeters performing a voltage-to-frequency conversion permit automatic range changing. Extra decades are switched into and out of the counting chain as a function of the counter during the previous counting period.

Roller, R. F.↗