Search NASASearch

SEARCH · Search NASA

Results for “Calibrating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

X-ray sources for in situ wavelength calibration of x-ray imaging crystal spectrometers

X-ray sources for a range of wavelengths are being considered for in situ calibration of X-ray Imaging Crystal Spectrometers (XICSs) and for monitoring line shifts due to changes in the crystal temperature, which can vary during experimental operation over a day [A. Ince-Cushman et al., Rev. Sci. Instrum. 79, 10E302 (2008), L. Delgado-Aparicio et al., Plasma Phys. Control. Fusion 55, 125011 (2013)]. Such crystal temperature dependent shifts, if not accounted for, could be erroneously interpreted as Doppler shifts leading to errors in plasma flow-velocity measurements. The x-ray sources encompass characteristic x-ray lines falling within the wavelength range of 0.9–4.0 Å, relevant for the XICSs on present and future fusion devices. Several technological challenges associated with the development of x-ray sources for in situ calibration are identified and are being addressed in the design of multiple x-ray tubes, which will be installed inside the spectrometer housing of the XICS for the JT-60SA tokamak. These x-ray sources will be especially useful for in situ calibration between plasma discharges. Here, in this paper, laboratory experiments are described that were conducted with a Cu x-ray source, a heated quartz (102) crystal, and a pixelated Pilatus detector to measure the temperature dependent shifts of the Cu Kα 1 and Kα 2 lines at 1.5405 and 1.5443 Å, respectively, and to evaluate the 2d-lattice constant for the Bragg reflecting crystal planes as a function of temperature, which, in the case of in situ wavelength calibration, would have to be used for numerical analysis of the x-ray spectra from the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Simultaneous energy and mass calibration of large-radius jets with the ATLAS detector using a deep neural network

The energy and mass measurements of jets are crucial tasks for the Large Hadron Collider experiments. This paper presents a new calibration method to simultaneously calibrate these quantities for large-radius jets measured with the ATLAS detector using a deep neural network (DNN). To address the specificities of the calibration problem, special loss functions and training procedures are employed, and a complex network architecture, which includes feature annotation and residual connection layers, is used. The DNN-based calibration is compared to the standard numerical approach in an extensive series of tests. The DNN approach is found to perform significantly better in almost all of the tests and over most of the relevant kinematic phase space. In particular, it consistently improves the energy and mass resolutions, with a 30% better energy resolution obtained for transverse momenta $p$ T > $500$ GeV.

47 OTHER INSTRUMENTATION

Composition Quantification of SiGeSn Alloys Through Time-of-Flight Secondary Ion Mass Spectrometry: Calibration Methodologies and Validation With Atom Probe Tomography

Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) is a powerful technique for elemental compositional analysis and depth profiling of materials. However, it encounters the problem of matrix effects that hinder its application. In this work, we introduce a pioneering ToF-SIMS calibration method tailored for SixGeySnz ternary alloys. SixGe1-x and Ge1-zSnz binary alloys with known compositions are used as calibration reference samples. Through a systematic SIMS quantification study of SiGe and GeSn binary alloys, we unveil a linear correlation between secondary ion intensity ratio and composition ratio for both SiGe and GeSn binary alloys, effectively mitigating the matrix effects. Extracted relative sensitivity factor (RSF) value from SixGe1-x (0.07 < x < 0.83) and Ge1-zSnz (0.066 < z < 0.183) binary alloys are subsequently applied to those of SixGeySnz (0.011 < x < 0.113, 0.863 < y < 0.935 and 0.023 < z < 0.103) ternary alloys for elemental compositions quantification. These values are cross-checked by Atom Probe Tomography (APT) analysis, an indication of the great accuracy and reliability of as-developed ToF-SIMS calibration process. Furthermore, the proposed method and its reference sample selection strategy in this work provide a low-cost as well as simple-to-follow calibration route for SiGeSn composition analysis, thus driving the development of next-generation multifunctional SiGeSn-related semiconductor devices.

36 MATERIALS SCIENCE

Measuring X-Ray Emission Line Shapes in Neutral Species for XRISM Calibration

Space X-ray spectrometers such as the Resolve instrument on XRISM require precise calibration in order to interpret the spectra of astrophysical objects. Key components of the calibration are the energy scale and the core line spread function, both of which vary with photon energy. A major issue in the calibration of high-resolution spectrometers is locating good calibrators with well-known and stable intrinsic line shapes. Neutral fluorescence is widely used, but inner-shell transitions in neutral atoms often exhibit complex, poorly documented line shapes that vary with excitation conditions. Here, in this study, we present empirical measurements of K-shell transitions in neutral O and F below 1 keV using an engineering model XRISM calorimeter array, an electron bombardment modulated X-ray source, and an electron beam ion trap (EBIT) to provide a precise energy reference. In addition, we report measurements of the Mo Lα complex with the transition-edge microcalorimeter spectrometer (TEMS), which reveal strong satellite structure and sensitivity of the line shape to the incident exciting spectrum. Together, these results demonstrate the need for empirical line-shape models, highlight the nonstationary nature of neutral fluorescence features, and define a path toward developing transfer standards for XRISM and future precision instruments such as Athena/X-IFU.

Astronomy and AstroPhysics

Absolute timing calibration of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

The Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM) is designed to have a good timing capability with the mission-level requirement of 1 ms as the absolute time tagging accuracy to suffice the needs for observatory science. In the ground calibration campaign, the absolute and relative timing offsets were measured using pulsed X-rays from the modulated X-ray sources. These offsets were used to determine calibration parameters, the Resolve timing coefficients, which are used in the offline correction of event times. In the orbit, reevaluation of the timing coefficients was carried out using the Crab pulsar, which was observed in two periods, one in the performance verification phase and the other in the guest observation phase. We report the absolute timing calibration of XRISM/Resolve using the ground and in-orbit data. Although the requirement is likely satisfied with the ground parameters, the timing coefficients have been refined using the in-orbit calibration to improve the timing accuracy. In addition, for the first time, we present the interpretation of the absolute timing offset originating from the analog and digital processing of X-ray events unique to a microcalorimeter spectrometer and present a complete view of the timing error of the Resolve instrument.

Astronomy and AstroPhysics

Ground calibration plan for the Athena/X-IFU microcalorimeter spectrometer

The X-ray Integral Field Unit is the X-ray imaging spectrometer on board one of ESA’s next large missions, Athena. Athena is set to investigate the theme of the Hot and Energetic Universe, with a launch planned in the late-2030s. Based on a high-sensitivity transition edge sensor (TES) detector array operated at very low temperature (50 mK), X-IFU will provide spatially resolved high-resolution spectroscopy of the X-ray sky in the 0.2 to 12 keV energy band, with an energy resolution goal of 4 eV up to 7 keV [3 eV design goal]. This work presents the current calibration plan of the X-IFU. It provides the requirements applicable to the X-IFU calibration, describes the overall calibration strategy, and details the procedure and sources needed for the ground calibration of each parameter or characteristics of the X-IFU.

47 OTHER INSTRUMENTATION

INL CRMO XRF Special Report No. 3: INL CRMO XRF Calibration Methods for the Analysis of Ceramics and Brick

This report details the analytical methods used by the Idaho National Laboratory Cultural Resource Management Office to characterize ceramic and brick artifacts using X-ray fluorescence spectrometry. More specifically, this report provides details on instrumentation, analysis times, and matrix-specific calibration protocols for ceramic materials. Calibration curves were developed to adjust raw instrumental output for 13 elements using a suite of reference standards made from historic brick borrowed from the Yale Peabody Museum. Calibration curves were validated by plotting predicted values against published reference values for the calibration set as well as a certified soil reference standard (SRM 2711a).

36 MATERIALS SCIENCE

Model Calibration with Markov Chain Monte Carlo Tutorial

The purpose of this tutorial is to demonstrate how to use Markov chain Monte Carlo (MCMC) to calibrate a model. By calibration, we mean the selection of model parameters (and, when relevant, structures). A common goal in model development and diagnostics is calibration, or the identification of model structures and parameters which are consistent with data. While models can be calibrated through hand-tuning parameters or minimizing simple error metrics such as root-mean-square-error (RMSE), these approaches can underrepresent the probabilistic nature of the data-generating process, as well as the potential for multiple model configurations to be consistent with the data. Probabilistic uncertainty quantification, which is the topic of this notebook, can address these concerns. This tutorial is presented as an appendix to the e-book: Addressing Uncertainty in MultiSector Dynamics Research.

Markov chain Monte Carlo

Further Development of the Tamped Richtmyer-Meshkov Instability Method and Application to Molybdenum Dynamic Strength Calibration and Tabulation

The high pressure and high strain rate dynamic strength of Mo is experimentally and computationally investigated in the 3–20 GPa stress, 50–600 C temperature, and 10 5 –10 6 /s strain rate regimes using a modified tamped Richtmyer-Meshkov instability (RMI) method. Modifications to the tamped RMI method include a method to determine loading states during strain, a new strength calibration function based on interface shape, and a robust uncertainty quantification method. These modifications improve fidelity of the tamped RMI method, allowing evaluation of the compensating effects of pressure hardening, strain rate hardening, strain hardening, and thermal softening. The new calibration function based on interface shape is not limited to sinusoidal corrugations and could be applied to additional interface shapes. Plate impact experiments are performed at Argonne National Laboratory’s Advanced Photon Source’s Dynamic Compression Sector operated by Washington State University (DCS), driving a planar shock front through a corrugated Mo-D 2 O or Mo-C 8 F 18 interface, forcing the corrugation to significantly deform. The extent of interfacial deformation, RMI growth, is experimentally observed using X-ray phase contrast imaging at the DCS. RMI jet lengths and jet shapes are extracted from the experimental radiographs, then used to calibrate numerical simulations performed with the Sandia National Laboratories (SNL) hydrocode CTH. Mo yield strength, Y, as a function of shock pressure, P, strain rate, $\dot{\varepsilon }$, accumulated strain, ϵ, relative volumetric compression, RD , and temperature, T , is determined for each impact experiment and presented. The calibrated Mo yield strength values range 1.2–1.8 GPa, with strength generally decreasing as the impact stress increases. This trend is likely caused by thermal softening or strain localization. The tabular yield strength versus loading condition data presented in this paper can be used to fit complex strength models.

Voorhees, T. J. [Sandia National Lab. (SNL-CA), Li

Long-term thermal stability and calibration of Type-II fiber Bragg grating array inscribed in radiation-hardened fibers

This paper investigates the long-term thermal stability of Type-II fiber Bragg grating (FBG) arrays, inscribed by femtosecond laser in radiation-hardened fiber, for potential applications as multiplexed sensors in high-temperature energy systems. The thermal stability of FBG sensors was assessed through 16 thermal cycles from room temperature (RT) to 750 ℃ about two months, involving 100 FBG sensors. The results show that the absolute temperature drift of FBG sensors can be reduced to less than 0.4 pm/day after 54 h thermal annealing process at a constant temperature of 800 ℃. As temperature sensors, the FBGs demonstrated stable performance, achieving a standard deviation (STD) of 1.8 pm (corresponding to a temperature resolution of 0.118 ℃) post-annealing. Repeated thermal cycles revealed a random drift of 2.3 pm in the FBG wavelength at RT. Polynomial fitting was explored as a calibration method to convert FBG wavelength shifts into absolute temperature measurements. By optimizing calibration temperature points (RT, 200 ℃, 400 ℃, and 750 ℃), the study shows that cubic polynomial calibration using four points yields an average R2 of 0.9997 and an RMSE of 3.58 ℃ across the entire temperature range (RT to 750 ℃). This approach represents an 11.53-fold improvement over empirical slope calibration and a 1.34-fold improvement over four-point piecewise fitting. The findings indicate that Type-II FBGs inscribed in radiation-hardened fibers can function as accurate temperature sensors, with performance on par with or exceeding that of thermocouples. With their multiplexing capability, robust signal transmission over long lead cables, and immunity to electromagnetic interference, FBG sensors offer a promising alternative to traditional electronic sensors for energy system monitoring.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018

Calibrating cryogenic temperature of TEM specimens using EELS

Cryogenic Scanning/Transmission Electron Microscopy has been established as a leading method to image sensitive biological samples and is now becoming a powerful tool to understand materials' behavior at low temperatures. However, achieving precise local temperature calibration at low temperatures remains a challenge, which is especially crucial for studying phase transitions and emergent physical properties in quantum materials. In this study, we employ electron energy loss spectroscopy (EELS) to measure local cryogenic specimen temperatures. Here we use the temperature-dependent characteristics of aluminum's bulk plasmon peak in EEL spectra, which shifts due to changes in electron density caused by thermal expansion and contraction. We successfully demonstrate the versatility of this method by calibrating different liquid nitrogen cooling holders in various microscopes, regardless of whether a monochromated or non-monochromated electron beam is used. Temperature discrepancies between the actual temperature and the setpoint temperatures are identified across a range from room temperature to 100 K. This work demonstrates the importance of temperature calibrations at intermediate temperatures and presents a straightforward, robust method for calibrating local temperatures of cryogenically-cooled specimens in electron microscopes.

36 MATERIALS SCIENCE

Ex situ calibration of the scattered-light time-history diagnostic on the National Ignition Facility

The scattered-light time-history diagnostic (SLTD) suite measures time-resolved scattered light in three wavelength bands: stimulated Brillouin scattering (350–352 nm), stimulated Raman scattering (430–760 nm), and plasma emission at half the laser frequency (695–735 nm), at 15 locations around the National Ignition Facility (NIF) target chamber. The SLTD, along with the full-aperture backscatter station (FABS), collects scattered light from direct- and indirect-drive inertial confinement fusion experiments. The SLTD calibration was revisited after a discrepancy between FABS and SLTD measurements was observed on NIF polar direct-drive experiments. An integrated calibration of the SLTD was performed for the first time, and individual components were also calibrated for the wavelengths of 351, 527, and 532 nm. The optical transmission of the instrument was measured to be (1.12 ± 0.04) × 10 –7 and (1.96 ± 0.11) × 10 –7 for the wavelengths of 351 and 532 nm, respectively. The revised calibration at 351 nm brings the SLTD measured scattered energy in agreement with the FABS measured scattered energy after additionally accounting for the degradation of an optical element in FABS. Furthermore, this decreased the inferred absorption by 7% for a representative experiment. However, discrepancies remain between FABS and SLTD measurements in the SRS band (532 nm).

47 OTHER INSTRUMENTATION

Characterization of the response of radiochromic film to quasi-monoenergetic x rays through a cross-calibration with image plates

Radiochromic film (RCF) and image plates (IPs) are both commonly used detectors in diagnostics fielded at inertial confinement fusion (ICF) and high-energy-density physics (HEDP) research facilities. Due to the intense x-ray background in all ICF/HEDP experiments, accurately calibrating the optical density of RCF as a function of x-ray dose, and the photostimulated luminescence per photon of IPs as a function of x-ray energy, is necessary for interpreting experimental results. Various measurements of the sensitivity curve of different IPs to x rays have been performed [Izumi et al., Proc. SPIE 8850, 885006 (2013) and Rosenberg et al., Rev. Sci. Instrum. 90(1), 013506 (2019)]; however, calibrating RCF is a tedious process that depends on factors such as the orientation in which the RCF is scanned in the film scanner and the batch of RCF used. These issues can be mitigated by cross-calibrating RCF with IPs to enable the use of IPs for the determination of dose on the RCF without scanning the RCF. Here, the first cross-calibration of RCF with IPs to quasi-monoenergetic titanium, copper, and molybdenum K-line x rays is presented. It is found that the IP-inferred dose rates on the RCF for the Ti and Mo x rays agree well with the measured dose rates, while the IP-inferred dose rate for the Cu x rays is larger than the measured dose rate by ∼2×. Explanations for this discrepancy and plans for future work are discussed.

Instruments & Instrumentation

Weak Lensing Mass Calibration of the ACT DR5 Galaxy Clusters with the DES Year 3 Weak Lensing Data

We use weak gravitational lensing measurements from Year 3 Dark Energy Survey data to calibrate the masses of 443 galaxy clusters selected via the Sunyaev-Zel'dovich effect from Atacama Cosmology Telescope Data Release 5 maps of the cosmic microwave background. We incorporate redshift and SZ measurements for individual clusters into a hierarchical model for the stacked lensing signals and perform Bayesian analyses to constrain the hydrostatic mass bias of the clusters. Our treatment of systematic uncertainties includes a prescription for measuring and accounting for the weak lensing boost factor, consideration of a miscentering effect, as well as marginalization over uncertainties in the source galaxy photometric redshift distributions and shear calibration. The resultant constraints on the normalization of the mass-observable relation have a precision of approximately 7%, with the mean WL halo mass of M $_{500c}$ = 5.4 × 10$^{14}$ M $_{⊙}$. We measure the bias between the true cluster mass and the mass estimated from the SZ signal based on an X-ray-calibrated scaling relation assuming hydrostatic equilibrium, to be 1 - b = 0.74$^{+0.06}$ $_{-0.05}$ over the full sample. When splitting the clusters into high (z = 0.43-0.70) and low (z = 0.15-0.43) redshift bins, we measure 1 - b = 0.58$^{+0.06}$ $_{-0.05}$ and 0.81$^{+0.08}$ $_{-0.06}$, respectively. When introducing additional freedom in redshift and mass to the hydrostatic bias model, we find that 1 - b decreases with redshift (with the power law of -1.8$^{+0.5}$ $_{-0.6}$, 99.95% confidence), consistent with findings from other recent studies, while we do not find any significant trend in mass. We also demonstrate that our result is robust against various systematics such as a scale cut, priors on baryonic and miscentering parameters, and degree of scatter in mass-observable relation. The weak-lensing mass calibration presented in this study will be a useful tool for using the ACT clusters as probes of astrophysics, and as a step towards using their abundance as a cosmological probe.

Shin, T. [Carnegie Mellon U.] (ORCID:0000000263895

The design, implementation, and performance of the LZ calibration systems

LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low energy nuclear recoils. Surrounding the TPC, two veto detectors immersed in an ultra-pure water tank enable reducing background events to enhance the discovery potential. Intricate calibration systems are purposely designed to precisely understand the responses of these three detector volumes to various types of particle interactions and to demonstrate LZ's ability to discriminate between signals and backgrounds. In this paper, we present a comprehensive discussion of the key features, requirements, and performance of the LZ calibration systems, which play a crucial role in enabling LZ's WIMP-search and its broad science program. The thorough description of these calibration systems, with an emphasis on their novel aspects, is valuable for future calibration efforts in direct dark matter and other rare-event search experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Anode sensitivity calibration of photomultiplier tubes used as a readout of the ELOSS detector

We present and discuss the methodology and results for an anode sensitivity calibration of Photomultiplier Tubes (PMTs) that serve as the optical readout of the Energy Loss Optical Scintillation System (ELOSS). The ELOSS detector, under development at the Facility for Rare Isotope Beams (FRIB), is a gaseous Xe scintillation-based detector designed to identify the atomic number (Z) of nuclear reaction fragments by energy-loss measurement. Variation in the anode sensitivity from tube to tube of commercially available PMTs limits ELOSS from reaching its ultimate Z resolution. A methodical approach to calibrating PMT anode sensitivities to a single target value by systematic PMT gain corrections is presented. Although the calibration process is discussed in terms of its impact on ELOSS performance, the presented method is applicable to any optical detector system composed of a large number of PMTs needing anode sensitivity calibration.

Instrumentation for heavy-ion accelerators

Electromagnetic energy calibration of the SoLid detector with horizontal muons

SoLid is a neutrino experiment at very-short baselinesearching for active-to-sterile oscillations of reactorantineutrinos. The detection principle is based on the pairing oftwo types of solid scintillators: polyvinyl toluene and $^{6}$Li:ZnS(Ag), which is a new technology used in this field ofPhysics. In addition to good neutron-gamma discrimination, thissetup allows the detector to be highly segmented; the basicdetection unit is a 5 cm cube. High segmentation provides numerousadvantages including precise localisation of the Inverse Beta Decay(IBD) products, the derivation of an antineutrino energy estimatorbased on the isolated positron energy, and a powerful backgroundreduction tool that relies on the topological signature of thesignal. Finally, the system is read out by a network ofwavelength-shifting fibres coupled to photosensors. A relativeelectromagnetic calibration is performed with horizontal cosmicmuons. This source poses the simplest calibration problem in which asingle detection unit is involved. In addition, large muon energydeposits allow us to perform a calibration at the most detailedlevel (i.e. per fibre) and to accurately define the fraction ofenergy escaping to neighbouring detection cells. A statisticalprecision at the sub-percent level is reached. The paper alsodiscusses two methods to calibrate the absolute energy scale andpresents their implementation and results. The first method relieson horizontal muons, though the precision is limited to around 10%because of the uncertainty in the energy distribution of suchmuons. A novel, alternative method based on the radioactiveamericium-beryllium source is proposed. It takes advantage of theelectron-positron pair-production process and provides a calibrationpoint at 3.4 MeV (i.e. in the core of the IBD positronspectrum). The paper is concluded with various cross-check includinga determination of the energy spectrum of the standard cosmogenicbackground candle: $^{12}$B.

Abreu, Y. [Antwerp U.]

Deep-field analytical calibration

The next generation of imaging surveys, including the Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST), Euclid, and the Nancy Grace Roman Space Telescope, will provide unprecedented constraints on cosmology using weak gravitational lensing. To fully exploit this statistical power, shear measurement methods must achieve sub- per cent accuracy while mitigating systematic biases from noise, the point-spread function (PSF), blending, and shear-dependent detection. The analytical calibration framework (AnaCal) has demonstrated such accuracy but requires adding noise to images, reducing effective depth. We introduce Deep-Field Analytical Calibration (DEEP-FIELD AnaCal), an extension of AnaCal that uses deep-field images to compute shear responses while preserving the statistical power of wide-field data. We validate DEEP-FIELD AnaCal on isolated and blended galaxy image simulations with LSST-like conditions, finding it meets the stringent requirement of multiplicative bias $|m| < 3\times 10^{-3}$ at 99.7 per cent confidence. Compared to standard AnaCal applied to wide-field images, DEEP-FIELD AnaCal increases the effective galaxy number density from 17 to 30 arcmin$^{-2}$ for simulated 10-yr LSST data. With deep fields $10\times$ longer than the wide field, we find pixel noise variance in shear estimation is reduced by 30 per cent and overall uncertainty by $\sim 25~{{\ \rm per\ cent}}$. Finally, using the LSST Deep Drilling Fields strategy, we assess sample variance and find an equivalent calibration uncertainty of $\lesssim 0.3~{{\ \rm per\ cent}}$. These results demonstrate that DEEP-FIELD AnaCal offers a promising path to achieve the required shear calibration for upcoming weak lensing surveys.

79 ASTRONOMY AND ASTROPHYSICS