Search NASA⌕ Search

SEARCH · Search NASA

Results for “Carlo”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Monte Carlo Analysis as a Trajectory Design Driver for the Transiting Exoplanet Survey Satellite (TESS) Mission

The Transiting Exoplanet Survey Satellite (TESS) will be injected into a highly eccentric Earth orbit and fly 3.5 phasing loops followed by a lunar flyby to enter a mission orbit with lunar 2:1 resonance. Through the phasing loops and mission orbit, the trajectory is significantly affected by lunar and solar gravity. We have developed a trajectory design to achieve the mission orbit and meet mission constraints, including eclipse avoidance and a 30-year geostationary orbit avoidance requirement. A parallelized Monte Carlo simulation was performed to validate the trajectory after injecting common perturbations, including launch dispersions, orbit determination errors, and maneuver execution errors. The Monte Carlo analysis helped identify mission risks and is used in the trajectory selection process.

monte carlo↗

A Study into Validating a Coupled Method of Characteristics and Direct Simulation Monte Carlo Method Against Empirical Data

The following will outline the methodology and results of validating a coupled Method of Characteristics (MOC) and Direct Simulation Monte Carlo (DSMC) method. This research focused specifically on modeling plume impingement, induced by Reaction Control System (RCS) thrusters that flew on the National Aeronautics and Space Administration’s (NASA’s) space shuttle Discovery. For each simulation, the continuum portion of the RCS thruster was simulated using MOC for solving hyperbolic Partial Differential Equations (PDEs) and computed with the NASA code, Reacting and Multi-phase Program (RAMP). The solution was then implemented as a starting condition into the NASA DSMC code, Direct Simulation and Monte Carlo Analysis Code (DAC). Typically, DSMC models rely on code-to-code validation for fidelity. The significance of this research is in its ability to validate its models against empirical data. Prior to computing solutions for these simulations, the mesh size and structure were optimized and many variants of DSMC input parameters were iterated on in order to acquire a reliable, mesh-independent, fully optimized numerical solution. This research will discuss the mathematical formulation of MOC for nozzle flow and DSMC for rarefied gases. Additionally, it will provide an explanation of how to implement these mathematical concepts into the two solvers: RAMP and DAC. Ultimately, this research will demonstrate that the overall process illustrated produces results in good agreement with empirical data. As a consequence, the methodology presented is granted an increased level of confidence and will greatly contribute to the aerospace industry and its effort in understanding and predicting rarefied flow fields.

Direct Simulation Monte Carlo Analysis Code↗

Monte-carlo maneuver analysis for the microwave anisotropy probe

The results of this trajectory replication are presented, followed by the results of monte-carlo maneuver simulations. The results are subject to two important assumptions: that linearization is valid (as the software used for the monte-carlo simulation, LAMBIC, is based on a linearization of the trajectory about the nominal) and that the planned human-in-the-loop lunar targeting may be approximated by targeting to a fixed aimpoint.

monte-carlo↗

Parallel Grand-Canonical Monte Carlo (ParaGrandMC) User’s Manual Version 2.0

This manual describes the commands and command line options for the Parallel Grand Canonical Monte Carlo version 2.0 (ParaGrandMC.2.0) simulation code. This is a highly scalable parallel FORTRAN 2003 code for simulating the thermodynamic evolution of materials at the atomic level, and predicting their thermodynamic state, phase diagram, chemical composition and mechanical properties. The code is specifically designed to simulate multi-component alloy systems, predict solid-state phase transformations such as austenite-martensite transformations, precipitate formation, recrystallization, capillary effects at interfaces, surface absorption, etc., which can aid the design of novel metallic alloys. While the software is mainly tailored for modeling metal alloys, it can also be used for other types of solid-state systems, and to some degree for liquid or gaseous systems, including multiphase systems forming solid-liquid-gas interfaces. In addition to performing Monte Carlo (MC) simulations, the code can also perform Molecular Dynamics (MD) and Langevin Dynamics (LD) simulations, which can be combined and interchanged with MC for faster and more efficient system evolution. A detailed description of the MC part of the code is provided in the NASA ParaGrandMC report: NASA/CR–2016-219202; http://www.sti.nasa.gov.

High performance computing↗

Applying Monte Carlo Simulation to Launch Vehicle Design and Requirements Verification

- This presentation applies statistics to launch vehicle design, but the methods may be used for other engineering applications - Vehicle Models: What do we know when? How to separate parameters for making Monte Carlo runs - Known when assembling the vehicle but not during design - Known prior to committing to flight - Unknown at lift off - How do we correctly model the vehicle during the design phases? - Number of Monte Carlo samples - Requirements success - Design parameter values

Monte Carlo↗

Computer simulation of supersonic rarefied gas flow in the transition region, about a spherical probe; a Monte Carlo approach with application to rocket-borne ion probe experiments

This report describes a Monte Carlo simulation of transition flow around a sphere. Conditions for the simulation correspond to neutral monatomic molecules at two altitudes (70 and 75 km) in the D region of the ionosphere. Results are presented in the form of density contours, velocity vector plots and density, velocity and temperature profiles for the two altitudes. Contours and density profiles are related to independent Monte Carlo and experimental studies, and drag coefficients are calculated and compared with available experimental data. The small computer used is a PDP-15 with 16 K of core, and a typical run for 75 km requires five iterations, each taking five hours. The results are recorded on DECTAPE to be printed when required, and the program provides error estimates for any flow field parameter.

Horton, B. E.↗

FASTER 3: A generalized-geometry Monte Carlo computer program for the transport of neutrons and gamma rays. Volume 2: Users manual

A description of the FASTER-III program for Monte Carlo Carlo calculation of photon and neutron transport in complex geometries is presented. Major revisions include the capability of calculating minimum weight shield configurations for primary and secondary radiation and optimal importance sampling parameters. The program description includes a users manual describing the preparation of input data cards, the printout from a sample problem including the data card images, definitions of Fortran variables, the program logic, and the control cards required to run on the IBM 7094, IBM 360, UNIVAC 1108 and CDC 6600 computers.

Jordan, T. M.↗

Discrete ordinates-Monte Carlo coupling: A comparison of techniques in NERVA radiation analysis

In the radiation analysis of the NERVA nuclear rocket system, two-dimensional discrete ordinates calculations are sufficient to provide detail in the pressure vessel and reactor assembly. Other parts of the system, however, require three-dimensional Monte Carlo analyses. To use these two methods in a single analysis, a means of coupling was developed whereby the results of a discrete ordinates calculation can be used to produce source data for a Monte Carlo calculation. Several techniques for producing source detail were investigated. Results of calculations on the NERVA system are compared and limitations and advantages of the coupling techniques discussed.

Lindstrom, D. G.↗

The response of a 300 micron silicon detector to monoenergetic neutrons determined by the use of the Monte Carlo technique

The response of a 300 micron thick silicon detector to an incident monoenergetic neutron beam is evaluated by the Monte Carlo method for the cases of both a shielded and a bare detector. The result of Monte Carlo calculation, using elastic, inelastic, and absorption reactions indicates that the response of the silicon detector to neutrons is basically due to the elastic scattering. In addition, the gamma rays generated in the shield of the detector will result in a response which is 3 or 4 orders of magnitude smaller than response to incident photons. The response of a bare silicon detector is calculated for neutron energies up to 6 MeV and bias energies from 50 to 250 KeV. It is found that the maximum response for a 300 micron thick silicon detector is less than .004 c/n within this selected neutron and bias energy range. When the pulse height defect is introduced in the calculation the results at low energy neutrons were reduced.

Tahezadeh, M.↗

Monte Carlo Simulation of Nonlinear Radiation Induced Plasmas

A Monte Carlo simulation model for radiation induced plasmas with nonlinear properties due to recombination was, employing a piecewise linearized predict-correct iterative technique. Several important variance reduction techniques were developed and incorporated into the model, including an antithetic variates technique. This approach is especially efficient for plasma systems with inhomogeneous media, multidimensions, and irregular boundaries. The Monte Carlo code developed has been applied to the determination of the electron energy distribution function and related parameters for a noble gas plasma created by alpha-particle irradiation. The characteristics of the radiation induced plasma involved are given.

Wang, B. S.↗

Monte Carlo inversion of seismic data

The analytic solution to the linear inverse problem provides estimates of the uncertainty of the solution in terms of standard deviations of corrections to a particular solution, resolution of parameter adjustments, and information distribution among the observations. It is shown that Monte Carlo inversion, when properly executed, can provide all the same kinds of information for nonlinear problems. Proper execution requires a relatively uniform sampling of all possible models. The expense of performing Monte Carlo inversion generally requires strategies to improve the probability of finding passing models. Such strategies can lead to a very strong bias in the distribution of models examined unless great care is taken in their application.

Wiggins, R. A.↗

Monte Carlo investigation of transient acoustic fields in partially or completely bounded medium

A simple repetitive calculation was used to investigate what happens to the field in terms of the signal paths of disturbances originating from the energy source. The computation allowed the field to be reconstructed as a function of space and time on a statistical basis. The suggested Monte Carlo method is in response to the need for a numerical method to supplement analytical methods of solution which are only valid when the boundaries have simple shapes, rather than for a medium that is bounded. For the analysis, a suitable model was created from which was developed an algorithm for the estimation of acoustic pressure variations in the region under investigation. The validity of the technique was demonstrated by analysis of simple physical models with the aid of a digital computer. The Monte Carlo method is applicable to a medium which is homogeneous and is enclosed by either rectangular or curved boundaries.

Thanedar, B. D.↗

Monte Carlo simulation of astronaut light flash observations on Apollo and Skylab missions

Monte Carlo calculations are performed to study the relation between cosmic ray nuclei and visual flashes observed by astronauts, in space. A satisfactory overall fit to all available data excluding the Skylab observations in the South Atlantic Anomaly (SAA) has been achieved by varying three visual system parameters: effective retinal thickness, minimum projected track length inside retina and minimum energy loss rate. All light flash data from space excluding the SAA observations can be understood fully upon the basis of the primary cosmic ray charge and energy spectra together with the fitted values of the three visual system parameters. Monte Carlo simulations of the SAA observations suggest the existence of a previously unobserved multiply-charged component of the inner radiation belt.

Osborne, W. Z.↗

Monte Carlo analysis of uncertainty propagation in a stratospheric model. 2: Uncertainties due to reaction rates

A concise stratospheric model was used in a Monte-Carlo analysis of the propagation of reaction rate uncertainties through the calculation of an ozone perturbation due to the addition of chlorine. Two thousand Monte-Carlo cases were run with 55 reaction rates being varied. Excellent convergence was obtained in the output distributions because the model is sensitive to the uncertainties in only about 10 reactions. For a 1 ppby chlorine perturbation added to a 1.5 ppby chlorine background, the resultant 1 sigma uncertainty on the ozone perturbation is a factor of 1.69 on the high side and 1.80 on the low side. The corresponding 2 sigma factors are 2.86 and 3.23. Results are also given for the uncertainties, due to reaction rates, in the ambient concentrations of stratospheric species.

Stolarski, R. S.↗

Determination of three-dimensional radiative exchange factors for the Space Shuttle by Monte Carlo

A program was developed to predict radiative exchange factors in three-dimensional configurations with curved, specularly-reflecting surfaces using the Monte Carlo method. It was shown that this can be done efficiently by using the normal Monte Carlo method for closed configurations and/or high surface emissivities, while Energy Partitioning should be used for open configurations and/or low surface emissivities. Comparison with experiments on the Space Shuttle radiator panels showed that the simple model of gray, diffuse emission is sufficient for the prediction of exchange factors between actual (silver-coated teflon) surfaces. For solar-irradiation exchange factors on the Space Shuttle, on the other hand, spectral and directional variations of surface properties must be taken into account.

Modest, M. F.↗

Uncertainty propagation in a stratospheric model. I - Development of a concise stratospheric model. II - Monte Carlo analysis of imprecisions due to reaction rates

The paper discusses the development of a concise stratospheric model which uses iteration to obtain coupling between interacting species. The one-dimensional, steady-state, diurnally-averaged model generates diffusion equations with appropriate sources and sinks for species odd oxygen, H2O, H2, CO, N2O, odd nitrogen, CH4, CH3Cl, CCl4, CF2Cl2, CFCl3, and odd chlorine. The model evaluates steady-state perturbations caused by injections of chlorine and NO(x) and may be used to predict ozone depletion. The model is used in a Monte Carlo study of the propagation of reaction-rate imprecisions by calculating an ozone perturbation caused by the addition of chlorine. Since the model is sensitive to only 10 of the more than 50 reaction rates considered, only about 1000 Monte Carlo cases are required to span the space of possible results.

Rundel, R. D.↗

Monte Carlo modeling of exospheric bodies - Mercury

In order to study the interaction with the surface, a Monte Carlo program is developed to determine the distribution with altitude as well as the global distribution of density at the surface in a single operation. The analysis presented shows that the appropriate source distribution should be Maxwell-Boltzmann flux if the particles in the distribution are to be treated as components of flux. Monte Carlo calculations with a Maxwell-Boltzmann flux source are compared with Mariner 10 UV spectrometer data. Results indicate that the presently operating models are not capable of fitting the observed Mercury exosphere. It is suggested that an atmosphere calculated with a barometric source distribution is suitable for more realistic future exospheric models.

Smith, G. R.↗

A comparative study of Conroy and Monte Carlo methods applied to multiple quadratures and multiple scattering

An efficient numerical method of multiple quadratures, the Conroy method, is applied to the problem of computing multiple scattering contributions in the radiative transfer through realistic planetary atmospheres. A brief error analysis of the method is given and comparisons are drawn with the more familiar Monte Carlo method. Both methods are stochastic problem-solving models of a physical or mathematical process and utilize the sampling scheme for points distributed over a definite region. In the Monte Carlo scheme the sample points are distributed randomly over the integration region. In the Conroy method, the sample points are distributed systematically, such that the point distribution forms a unique, closed, symmetrical pattern which effectively fills the region of the multidimensional integration. The methods are illustrated by two simple examples: one, of multidimensional integration involving two independent variables, and the other, of computing the second order scattering contribution to the sky radiance.

Deepak, A.↗