DOE-CEA Benchmark on SFR ASTRID Innovative Core: N
ASTRID is a fast reactor being designed by CEA to
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
ASTRID is a fast reactor being designed by CEA to
This paper presents a nuclear data uncertainty propagation analysis for two CEA's Sodium-cooled Fast Reactor designs: the SFR V2B and CFV cores. The nuclear data covariance matrices are provided by the DER/SPRC/LEPh's nuclear data team (see companion paper) for several major isotopes. From the current status of this analysis, improvements on certain nuclear data reactions are highlighted as well as the need for new specific integral experiments in order to meet the technological breakthroughs proposed by the CFV core. (authors)
Soon after the Tokai Mura criticality accident, the French nuclear authority addressed nuclear operators to take measures regarding criticality safety. In CEA in particular after a thorough assessment of the late 1990's - early 2000's practices, the decision was taken to put up a training program in criticality safety for young (and 'old') nuclear safety specialists. The evolution of the training practices for the IQC (Ingenieurs Qualifies en Criticite - Engineers Qualified in Criticality safety) are presented hereafter, beginning with the first training session set up in October 2001 until now. This primarily deals with the kind of audience this training addresses (professional background), what is taught, learned, used later on and how one becomes an IQC. Furthermore, a discussion involves who recognizes the qualification, how long does one need to become a real criticality safety specialist on an operational basis, how the staff uses (or not) the knowledge and how this ensemble contributes to the professional careers advancement (criticality safety is a strong 'card'). The methodological documents in support of the IQC are also presented, particularly the last version of the 'criticality guide fiches (files, cards, sheets)' collection which summarizes the main aspects and principles of criticality safety (including the rudiments of neutron physics, criticality control modes, double contingency principle, etc.). (authors)
Abstract not provided.
The decladding units on the Marcoule nuclear site in southeast France were commissioned in the early 1960's to receive spent fuel cartridge for interim storage in pools and to prepare them for dissolution. After decladding, the uranium slugs were sent to the reprocessing plant for dissolution. The units were shut down in 1997. All the operational and process equipment was dismantled and transferred to the ANDRA waste repository between 1998 and 2001. During cleanup of the G2-G3 interim storage pool all the internal components (baskets and machinery) mounted on the civil engineering structures were cut up. In November 2007, a UNGG fuel slug in its aluminum cartridge was found at the bottom of the pool. Similarly, while iron slugs (used to control plutonium-producing reactors) were being sorted, five de-cladded uranium slugs were found between 2006 and 2008. As the processing facilities had already been dismantled, it was decided to send these fuel cartridges to a laboratory for dissolution. The project was to recover and condition the cartridge and slugs and transport them safely to the laboratory. This required the design of dedicated equipment due in particular to the high dose rate and pyro-phoricity hazard. The procedure also required safety clearance by the regulatory authorities for the operations within the facility and for the transport of radioactive materials. The cartridge was dissolved in May 2009, 18 months after it was discovered. Based on the experience acquired, the retrieval of the uranium slugs was completed in March 2011 after a year of preparation. (authors)
Abstract not provided.
No abstract available
Modeling droplet condensation via CFD codes can be very tedious, time consuming, and inaccurate. CFD codes may be tedious and time consuming in terms of using Lagrangian particle tracking approaches or particle sizing bins. Also since many codes ignore conduction through the droplet and or the degradating effect of heat and mass transfer if noncondensible species are present, the solutions may be inaccurate. The modeling of a condensing spray chamber where the significant size of the water droplets and the time and distance these droplets take to fall, can make the effect of droplet conduction a physical factor that needs to be considered in the model. Furthermore the presence of even a relatively small amount of noncondensible has been shown to reduce the amount of condensation. It is desirable then to create a modeling tool that addresses these issues. The path taken to create such a tool is illustrated. The application of this tool and subsequent results are based on the spray chamber in the Spacecraft Propulsion Research Facility (B2) located at NASA's Plum Brook Station that tested an RL-10 engine. The platform upon which the condensation physics is modeled is SINDAFLUINT. The use of SINDAFLUINT enables the ability to model various aspects of the entire testing facility, including the rocket exhaust duct flow and heat transfer to the exhaust duct wall. The ejector pumping system of the spray chamber is also easily implemented via SINDAFLUINT. The goal is to create a transient one dimensional flow and heat transfer model beginning at the rocket, continuing through the condensing spray chamber, and finally ending with the ejector pumping system. However the model of the condensing spray chamber may be run independently of the rocket and ejector systems detail, with only appropriate mass flow boundary conditions placed at the entrance and exit of the condensing spray chamber model. The model of the condensing spray chamber takes into account droplet conduction as well as the degrading effect of mass and heat transfer due to the presence of noncondensibles. The one dimension model of the condensing spray chamber makes no presupposition on the pressure profile within the chamber, allowing the implemented droplet physics of heat and mass transfer coupled to the SINDAFLUINT solver to determine a transient pressure profile of the condensing spray chamber. Model results compare well to the RL-10 engine pressure test data.
Modeling droplet condensation via CFD codes can be very tedious, time consuming, and inaccurate. CFD codes may be tedious and time consuming in terms of using Lagrangian particle tracking approaches or particle sizing bins. Also since many codes ignore conduction through the droplet and or the degradating effect of heat and mass transfer if noncondensible species are present, the solutions may be inaccurate. The modeling of a condensing spray chamber where the significant size of the water droplets and the time and distance these droplets take to fall, can make the effect of droplet conduction a physical factor that needs to be considered in the model. Furthermore the presence of even a relatively small amount of noncondensible has been shown to reduce the amount of condensation [Ref 1]. It is desirable then to create a modeling tool that addresses these issues. The path taken to create such a tool is illustrated. The application of this tool and subsequent results are based on the spray chamber in the Spacecraft Propulsion Research Facility (B2) located at NASA's Plum Brook Station that tested an RL-10 engine. The platform upon which the condensation physics is modeled is SINDAFLUINT. The use of SINDAFLUINT enables the ability to model various aspects of the entire testing facility, including the rocket exhaust duct flow and heat transfer to the exhaust duct wall. The ejector pumping system of the spray chamber is also easily implemented via SINDAFLUINT. The goal is to create a transient one dimensional flow and heat transfer model beginning at the rocket, continuing through the condensing spray chamber, and finally ending with the ejector pumping system. However the model of the condensing spray chamber may be run independently of the rocket and ejector systems detail, with only appropriate mass flow boundary conditions placed at the entrance and exit of the condensing spray chamber model. The model of the condensing spray chamber takes into account droplet conduction as well as the degrading effect of mass and heat transfer due to the presence of noncondensibles. The one dimension model of the condensing spray chamber makes no presupposition on the pressure profile within the chamber, allowing the implemented droplet physics of heat and mass transfer coupled to the SINDAFLUINT solver to determine a transient pressure profile of the condensing spray chamber. Model results compare well to the RL-10 engine pressure test data.
Explore the source record for details and available documents.
Abstract Not Provided
Explore the source record for details and available documents.
Abstract not provided.
Explore the source record for details and available documents.
Abstract not provided.
Trip report from the aerial gamma spectroscopy exercise in France in 2019, to be provided to Lithuanian State Border Guard Service (SBGS) as answers to their technical questions.
Purpose: To evaluate the role of serum carcinoembryonic antigen (CEA) as a predictor of response to preoperative chemoradiotherapy (CRT) and prognostic factor for rectal cancer. Materials and Methods: The study retrospectively evaluated 352 locally advanced rectal cancer patients who underwent preoperative CRT followed by surgery. Serum CEA levels were determined before CRT administration (pre-CRT CEA) and before surgery (post-CRT CEA). Correlations between pre-CRT CEA levels and rates of good response (Tumor regression grade 3/4) were explored. Patients were categorized into three CEA groups according to their pre-/post-CRT CEA levels (ng/mL) (Group A: pre-CRT CEA {<=} 3; B: pre-CRT CEA >3, post-CRT CEA {<=}3; C: pre- and post-CRT CEA >3 ng/mL), and their oncologic outcomes were compared. Results: Of 352 patients, good responses were achieved in 94 patients (26.7%). The rates of good response decreased significantly as the pre-CRT CEA levels became more elevated (CEA [ng/mL]: {<=}3, 36.4%; 3-6, 23.6%; 6-9, 15.6%; >9, 7.8%; p < 0.001). The rates of good response were significantly higher in Group A than in Groups B and C (36.4% vs. 17.3% and 14.3%, respectively; p < 0.001). The 3-year disease-free survival rate was significantly better in Groups A and B than in Group C (82% and 79% vs. 57%, respectively; p = 0.005); the CEA grouping was identified as an independent prognostic factor (p = 0.025). Conclusions: In locally advanced rectal cancer patients, CEA levels could be of clinical value as a predictor of response to preoperative CRT and as an independent prognostic factor after preoperative CRT and curative surgery.