Search NASA⌕ Search

SEARCH · Search NASA

Results for “Chemistry, Analytical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A projection-based analytical Jacobian framework for chemical kinetics applications

A major challenge in simulating complex combustion systems with detailed chemical kinetic models is the cost of integrating the chemical source terms, often done using stiff ODE solvers that require frequent Jacobian evaluations. Using analytically derived Jacobian matrices instead of divided-difference-based numerical Jacobian approximations can significantly reduce the associated computational cost. However, ambiguities arise in the formulation of analytical Jacobians because the chemical state of the system, or state vector, can be expressed in multiple ways, involving variables that are typically not independent from one another. Here, in this work, the consequences of those ambiguities on practical calculations are characterized in detail, and a generalized, projection-based framework is proposed as a mitigation strategy. Performances are assessed in a series of test cases involving a variety of configurations and numerical solution approaches. Results show that with proper treatment, commonly used analytical Jacobian formulations can be considered as equivalent for practical purposes, thereby alleviating concerns that the state vector chosen to express the governing equations and corresponding analytical Jacobian may significantly impact the accuracy of the simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effective kinetics driven by dynamic concentration gradients under coupled transport and reaction

Biogeochemical reaction kinetics are generally established from batch reactors where concentrations are uniform. In natural systems, many biogeochemical processes are characterized by spatially and temporally variable concentration gradients that often occur at scales which are not resolved by field measurements or biogeochemical and reactive transport models. Yet, it is not clear how these sub-scale chemical gradients affect reaction kinetics compared to batch kinetics. Here we investigate this question by studying the paradigmatic case of localized pulses of solute reacting with a solid or a dissolved species in excess. Additionally, we consider non-linear biogeochemical reactions, representative of mineral dissolution, adsorption and redox reactions, which we quantify using simplified power-law kinetics. The combined effect of diffusion and reaction leads to effective kinetics that differ quantitatively and qualitatively from the batch kinetics. Depending on the nonlinearity (reaction order) of the local kinetics, these effects lead to either enhancement or decrease of the overall reaction rate, and result in a rich variety of reaction dynamics. We derive analytical results for the effective kinetics, which are validated by comparison to direct numerical simulations for a broad range of Damköhler numbers and reaction order. Our findings provide new insights into the interpretation of imperfectly mixed lab experiments, the effective kinetics of field systems characterized by intermittent reactant release and the integration of sub-scale concentration gradients in reactive transport models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

4D-STEM of Beam-Sensitive Materials

We report that a scanning electron nanobeam diffraction, or 4D-STEM (four-dimensional scanning transmission electron microscopy), is a flexible and powerful approach to elucidate structure from "soft" materials that are challenging to image in the transmission electron microscope because their structure is easily damaged by the electron beam. In a 4D-STEM experiment, a converged electron beam is scanned across the sample, and a pixelated camera records a diffraction pattern at each scan position. This four-dimensional data set can be mined for various analyses, producing maps of local crystal orientation, structural distortions, crystallinity, or different structural classes. Holding the sample at cryogenic temperatures minimizes diffusion of radicals and the resulting damage and disorder caused by the electron beam. The total fluence of incident electrons can easily be controlled during 4D-STEM experiments by careful use of the beam blanker, steering of the localized electron dose, and by minimizing the fluence in the convergent beam thus minimizing beam damage. This technique can be applied to both organic and inorganic materials that are known to be beam-sensitive; they can be highly crystalline, semicrystalline, mixed phase, or amorphous. One common example is the case for many organic materials that have a π-π stacking of polymer chains or rings on the order of 3.4-4.2 Å separation. If these chains or rings are aligned in some regions, they will produce distinct diffraction spots (as would other crystalline spacings in this range), though they may be weak or diffuse for disordered or weakly scattering materials. We can reconstruct the orientation of the π-π stacking, the degree of π-π stacking in the sample, and the domain size of the aligned regions. This Account summarizes illumination conditions and experimental parameters for 4D-STEM experiments with the goal of producing images of structural features for materials that are beam-sensitive. We will discuss experimental parameters including sample cooling, probe size and shape, fluence, and cameras. 4D-STEM has been applied to a variety of materials, not only as an advanced technique for model systems, but as a technique for the beginning microscopist to answer materials science questions. It is noteworthy that the experimental data acquisition does not require an aberration-corrected TEM but can be produced on a variety of instruments with the right attention to experimental parameters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Further Investigations of Racemic and Chiral Molecular Sieves of the STW Topology

Large single crystals of pure-silica STW-type molecular sieves are prepared using 1,2,3,4,5-pentamethylimidazolium (12345PMI) and 2-ethyl-1,3,4-trimethylimidazolium (2E134TMI) as organic structure-directing agents (OSDAs) and α-amino acid additives. The effects of the amount and type of amino acid on the crystallization of pure-silica STW materials are investigated. Room-temperature single-crystal X-ray diffractometry shows that 12345PMI better fits the STW cage than 2E134TMI and is fully consistent with computed simulations. The synthesis of an enantioenriched R-STW-type molecular sieve having a Si/Ge ratio of 2.2 is achieved using a chiral, dicationic OSDA that contains two stereocenters. Furthermore, the conformation of the chiral OSDA in the chiral framework has been obtained from a Rietveld refinement using synchrotron powder diffraction data and is the first structure refinement of an enantioenriched, inorganic molecular sieve prepared from a pure, asymmetric OSDA.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of Temperature on Flow Fouling of Smooth and Nonwetting Surfaces

Mineral fouling (scaling) of heat transfer surfaces is a pervasive problem in heat exchangers, chemical reactors, and other equipment in energy, environmental, and process industrial applications. Many of the applications involve dynamic flow of fluids with the impurity minerals and, furthermore, operate at elevated temperature. Strategies to mitigate fouling under these conditions are of much value in industrial applications. This paper presents a comparative study of temperature-dependent mineral fouling deposition on smooth surfaces and nonwetting superhydrophobic and lubricant-infused surfaces under dynamic flow conditions. The surfaces are represented in a unified manner using the viscosity ratio of the infused material within the porous asperities on a surface to that of the flowing fluid such that the spectrum of surfaces from superhydrophobic to smooth is captured by the range of viscosity ratios from 0 to ∞. Using a forced convection experimental setup, deposition of calcium sulfate on the surfaces is quantified in terms of asymptotic fouling resistance over a range of temperature, Reynolds number, and mineral foulant supersaturation. Through a systematic set of accelerated fouling experiments, an empirical relationship for the asymptotic fouling resistance is developed in terms of Reynolds number, foulant concentration, temperature, and surface type. The empirical model is validated with a comprehensive set of experimental data from this study as well as from the literature. Optimum nonwetting surface designs for minimizing fouling resistance compared to conventional smooth surfaces are developed as a function of temperature. The results of the study offer insight into the temperature-dependent fouling of surfaces under flow conditions and a rational design of fouling-resistant nonwetting surfaces that can be readily translated to practice.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spray Mechanism of Contained-Electrospray Ionization

Analytical characteristics of contained electrospray ionization (ESI) are summarized in terms of its potential to modify the analyte solution during the stages of droplet formation to provide opportunities to generate native versus denatured biomolecular gas-phase ions, without the need for bulk-phase analyte modifications. The real-time modification of the charged microdroplets occurs in a cavity that is included in the outlet of the contained-ESI ion source. Close examination of the inside of the cavity using a high-speed camera revealed the formation of discrete droplets as well as thin liquid films in the droplets wake. When operated at 20 psi N2 pressure, the droplets were observed to move at an average speed of 8 mm/s providing ~1 s mixing time in a 10 mm cavity length. Evidence is provided for the presence of highly reactive charged droplets based on myoglobin charge state distribution, apo-myoglobin contents, and ion mobility drift time profiles under different spray conditions. Mechanistic insights for the capture of vapor-phase reagents and droplet dynamics as influenced by different operational modes are also described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Highlighting the Importance of Authentic Reference Chemicals in the Unambiguous Identification of Unknowns during Routine Sample Analysis─An OPCW Proficiency Test Case

The unequivocal identification of unknown chemicals during routine sample analysis is a constant occurrence in the field of analytical chemistry. The process can be painstakingly tedious, particularly in situations where a tentatively identified unknown may possess isomeric counterparts yielding identical accurate mass values and very similar mass spectra. In this work, we present the experimental process involved in the correct identification of 1,4-oxathiane 4,4-dioxide and differentiation from its constitutional isomer, 2-hydroxyethyl vinyl sulfone, when present in a silica gel matrix featured in the 54th Environmental Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency test. After discovering that the library-generated mass spectrum for 2-hydroxyethyl vinyl sulfone in a preliminary gas chromatography–mass spectrometry (GC-MS) analysis did not match the one from an authentic reference chemical, we embarked on an unknown structure determination campaign involving GC-MS, liquid chromatography-tandem mass spectrometry (LC-MS-MS), and nuclear magnetic resonance (NMR) spectroscopy. All of the information obtained, coupled to the synthesis of an authentic reference chemical, was used to determine the identity of the unknown as 1,4-oxathiane 4,4-dioxide. The process described in this work highlights the important role played by authentic reference chemicals in the identification of unknown chemicals during routine sample analysis.

Chemistry↗

Temperature-dependent complex dielectric permittivity: a simple measurement strategy for liquid-phase samples

Abstract Microwaves (MWs) are an emerging technology for intensified and electrified chemical manufacturing. MW heating is intimately linked to a material’s dielectric permittivity. These properties are highly dependent on temperature and pressure, but such datasets are not readily available due to the limited accessibility of the current methodologies to process-oriented laboratories. We introduce a simple, benchtop approach for producing these datasets near the 2.45 GHz industrial, medical, and scientific (ISM) frequency for liquid samples. By building upon a previously-demonstrated bireentrant microwave measurement cavity, we introduce larger pressure- and temperature-capable vials to deduce temperature-dependent permittivity quickly and accurately for vapor pressures up to 7 bar. Our methodology is validated using literature data, demonstrating broad applicability for materials with dielectric constant ε' ranging from 1 to 100. We provide new permittivity data for water, organic solvents, and hydrochloric acid solutions. Finally, we provide simple fits to our data for easy use.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analytic gradients for relativistic exact-two-component equation-of-motion coupled-cluster singles and doubles method

A first implementation of analytic gradients for spinor-based relativistic equation-of-motion coupled-cluster singles and doubles method using an exact two-component Hamiltonian augmented with atomic mean-field spin–orbit integrals is reported. To demonstrate its applicability, we present calculations of equilibrium structures and harmonic vibrational frequencies for the electronic ground and excited states of the radium mono-amide molecule (RaNH 2 ) and the radium mono-methoxide molecule (RaOCH 3 ). Spin–orbit coupling is shown to quench Jahn–Teller effects in the first excited state of RaOCH 3 , resulting in a C 3v equilibrium structure. Furthermore, the calculations also show that the radium atoms in these molecules serve as efficient optical cycling centers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Liquid-to-gas transfer of sodium in a liquid anode glow discharge

Solute transfer from the liquid to the gas phase in plasmas has been widely used in analytical chemistry often focused on liquid cathode discharges. In this study, we report on time-resolved absolute density measurements of sodium in a glow discharge plasma with a NaCl solution anode using two-photon absorption laser induced fluorescence. The averaged maximum sodium density is found to be similar to the electron density in the discharge consistent with plasma-induced vapor generation. Random sodium flashes were also observed extending into the plasma afterglow and are attributed to sodium particles falling back on the liquid surface. Cataphoresis can explain the location of the maximum sodium density near the cathode side of the electrode gap rather than near the liquid anode region.

chemical vapor generation↗

CFM-ID 4.0 – a web server for accurate MS-based metabolite identification

The CFM-ID 4.0 web server (https://cfmid.wishartlab.com) is an online tool for predicting, annotating and interpreting tandem mass (MS/MS) spectra of small molecules. It is specifically designed to assist researchers pursuing studies in metabolomics, exposomics and analytical chemistry. More specifically, CFM-ID 4.0 supports the: 1) prediction of electrospray ionization quadrupole time-of-flight tandem mass spectra (ESI-QTOF-MS/MS) for small molecules over multiple collision energies (10 eV, 20 eV, and 40 eV); 2) annotation of ESI-QTOF-MS/MS spectra given the structure of the compound; and 3) identification of a small molecule that generated a given ESI-QTOF-MS/MS spectrum at one or more collision energies. The CFM-ID 4.0 web server makes use of a substantially improved MS fragmentation algorithm, a much larger database of experimental and in silico predicted MS/MS spectra and improved scoring methods to offer more accurate MS/MS spectral prediction and MS/MS-based compound identification. Compared to earlier versions of CFM-ID, this new version has an MS/MS spectral prediction performance that is ~22% better and a compound identification accuracy that is ~35% better on a standard (CASMI 2016) testing dataset. CFM-ID 4.0 also features a neutral loss function that allows users to identify similar or substituent compounds where no match can be found using CFM-ID’s regular MS/MS-to-compound identification utility. Finally, the CFM-ID 4.0 web server now offers a much more refined user interface that is easier to use, supports molecular formula identification (from MS/MS data), provides more interactively viewable data (including proposed fragment ion structures) and displays MS mirror plots for comparing predicted with observed MS/MS spectra. These improvements should make CFM-ID 4.0 much more useful to the community and should make small molecule identification much easier, faster, and more accurate.

59 BASIC BIOLOGICAL SCIENCES↗

Cold Testing for Characterization of Oxide Feed Impurities in Support of the ARIES Program

The Advanced Recovery and Integrated Extraction System (ARIES) Program converts surplus plutonium metal components into an oxide powder form and packages the material for final disposition. In support of the ARIES program, over a metric ton (MT) of plutonium has been removed from surplus nuclear weapons since 1998 and packaged for long-term storage in 3013 cans. The oxide production rate is anticipated to increase substantially over the next decade in support of dilute and dispose goals. Analytical chemistry data from destructive analysis of the resulting 70+ blend lots to date has been reported for contaminants in the product oxide. Changes in the Pu product specification for Pu oxide product, induced by a different pit mix, the LANL swap program and processing Alternate (non-Pit Pu) Feed Stock (AFS) metals, will affect the level and the mix of these contaminants in the upcoming years. With these changes in feed material, it will be important to provide fast and efficient measurement of elemental impurities in the oxide to be certain that the process is under control and to monitor the anticipated changes from the historical blend lot data. Non-destructive methods need to be evaluated for the characterization of the plutonium oxide product and the quantification of the impurities at the current and anticipated levels. A feasibility study has begun to investigate the applicability of new spectroscopic methods for oxide impurity characterization. To this end, here we describe the preparation of surrogate materials to support these investigations, and the results of a feasibility study investigating the use of LIBS (Laser Induced Breakdown Spectroscopy) to characterize the surrogate materials as calibration standards.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

C-AAC Occupancy and Transition Out of CMR [Slides]

This in-depth evaluation was performed in order to gather information for a plan and time estimate of C-AAC space cleanout and handover to the CMR facility once programmatic operations are relocated to other facilities. C-AAC space ownership in CMR wings 1, 5, 7, and 9 have been identified down to the Team level (see subsequent slides and other supporting documentation). This plan assumes that C-AAC activities that support Pu sustainment efforts (Wings 1, 5, and 7) are relocated to PF-4 and RLUOB in mid/end FY24 and current projects in Wing 9 are completed by the end of FY24/mid FY25 (cessation of C-AAC programmatic operations in CMR). This plan assumes that no other programmatic activities are initiated in CMR (e.g. MOX fuel rods). Timing and order of cleanout of programmatic laboratory and office spaces in wings 1, 5, and 7 is dependent upon analytical chemistry operations being established and relocated to RLUOB and PF-4. Timing and order of cleanout of programmatic laboratory and office spaces in wing 9 is dependent upon completion of current projects (MR&R, Thermo Fisher drum, etc.). As C-AAC Teams move out of the CMR building and into other facilities, the spaces occupied by those teams are planned to be targeted for in depth cleanout in the order that teams and capabilities are relocated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Energy X-ray Diffraction Microscopy for Nuclear Forensics FY2022 Project Report

Morphological information on nuclear material has been identified using visible light and scanning electron microscopy. These identify qualitative differences in particle morphology. Three-dimensional imaging of materials through alternating scanning electron microscopy imaging and focused ion beam milling has also been used. Unfortunately, these techniques are time- and labor-intensive, with significant sample preparation required and lengthy analysis times. Further, the resulting 3D images are qualitative, require manual identification, and do not capture statistically-representative populations. High energy X-ray 3D imaging using a direct-beam or diffracted-beam (High-Energy Diffraction Microscopy) have been developed at the Advanced Photon Source and can produce quantitative information on grains (phase, location, etc.) and pores (size distribution, sphericity) in a material. These techniques require only minutes to characterize a sample volume and are non-destructive, thus suitable for a wide range of existing samples and for confirmatory analyses to be carried out using conventional microscopy techniques. In this first year of the project, all uranium oxide samples were synthesized and characterized using conventional analyses by the analytical chemistry laboratory. Conventional analysis methods included powder x-ray diffraction, scanning electron microscopy, impurity analysis via inductively coupled plasma mass spectrometry, and infrared spectroscopy. Impurity analysis shows a drop in boron content from UO 3 to the lowest U 3 O 8 calcination temperature, but otherwise no appreciable difference in any sample. Analysis of diffraction data shows a flip of peaks from UO 3 dominated for the 600 °C calcined sample to U 3 O 8 dominated at 700 °C and 800 °C. Analysis of scanning electron microscopy images shows that with increased calcination temperature the size distribution of particles seems to increase and broaden. Both of these last findings are in line with previously published data, though this work used significantly fewer particles to simply show similar trends instead of getting truly quantitative particle analysis. Infrared analysis similarly shows ingrowth of U 3 O 8 as calcination temperature is increased, along with depression of peaks associated with UO 3 and water. Samples were prepared for analysis at the Advanced Photon Source at beamline 1-ID. It is anticipated that analysis will occur in November of 2022. AI/ML techniques to de-noise data coming out of 1-ID during the analyses was also developed during this time using previously gathered data. Preliminary results using a self-supervision technique called Noise2Selfshow good de-noising of data. Once the uranium oxide samples are analyzed, real data will be used to test the de-noising and other AI/ML techniques that may be developed in the second year of the project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Novel Harsh Environment Materials and Fabrication Techniques for Wireless Sensor Applications (Final Report)

The overarching goal of this project is to establish a center of excellence program at the University of Maine that is focused on Harsh Environmental Materials and Fabrication Techniques for Wireless Sensor Applications. UMaine is well-positioned to build on previous successes in the areas of materials science research and sensor engineering. Since 1980, the Laboratory for Surface Science & Technology (LASST) has been a very successful interdisciplinary UMaine research center with a well-established infrastructure to investigate surfaces, interfaces, thin films, and micro/nano-fabrication. This infrastructure established through NSF, DOE, DOD, NASA, the State of Maine, and industry includes (i) a 3,500 ft2 clean room with nano/microfabrication and photolithography instrumentation, (ii) thin film synthesis, processing and characterization, (iii) surface and thin film analytical chemistry tools, and (iv) device packaging, electronic testing, wireless devices, system fabrication, and sensor test facilities. This strong foundation is the basis for a planned significant growth in R&D capacity currently underway. To that end, since the start of this project in the Fall of 2019, LASST has undergone a transition to become a new interdisciplinary center at UMaine, named the Frontier Institute for Research in Sensor Technologies (FIRST). This new focus represents a commitment and investment by UMaine that aligns with the proposed DOE-EPSCoR theme, capitalizing on the state-of-the-art instrumentation to form an energized group of faculty and students pursuing advances in sensor materials, devices, and applications.

36 MATERIALS SCIENCE↗