At least 73 records · Page 4

Analysis of flight effects on noise radiation from dual-flow coaxial jets

A theoretical study has been made of the effects of flight on noise from dual-flow coaxial jets. The theory is based on an instability free, vortex sheet flow model. It is shown that the flight effects are more favorable (and hence produce less forward-arc amplification) for coaxial jets than for single-stream jets. Further, the theory predicts that, like the single-stream jet case, flight effects induce noise amplification in the forward quadrant and attenuation in the aft quadrant and have virtually no effect at theta = 90 deg to the jet axis, where theta is the angle between the directions of convection and emission at the retarded time. Amplification in the forward quadrant diminishes as the inner flow velocity increases and becomes optimum when the outer-to-inner velocity ratio is about 0.5. The theory also shows that the higher the outer-to-inner area ratio, the lower the forward-arc amplification due to flight.

Dash, R.↗

Experimental study of coaxial nozzle exhaust noise

Experimental results are presented for static acoustic model tests of various geometrical configurations of coaxial nozzles operating over a range of flow conditions. The geometrical configurations consisted of nozzles with coplanar and non-coplanar exit planes and various exhaust area ratios. Primary and secondary nozzle flows were varied independently over a range of nozzle pressure ratios from 1.4 to 3.0 and gas temperatures from 280 to 1100 K. Acoustic data are presented for the conventional mode of coaxial nozzle operation as well as for the inverted velocity profile mode. Comparisons are presented to show the effect of configuration and flow changes on the acoustic characteristics of the nozzles.

Goodykoontz, J. H.↗

Noise suppression due to annulus shaping of an inverted-velocity-profile coaxial nozzle

An inverted velocity profile coaxial nozzle for use with supersonic cruise aircraft produces less jet noise than an equivalent conical nozzle. Furthermore, decreasing the annulus height (increasing radius ratio with constant flow) results in further noise reduction benefits. The annulus shape (height) was varied by an eccentric mounting of the annular nozzle with respect to a conical core nozzle. Acoustic measurements were made in the flyover plane below the narrowest portion of the annulus and at 90 deg and 180 deg from this point. The model-scale spectra are scaled up to engine size (1.07 m diameter) and the perceived noise levels for the eccentric and baseline concentric inverted velocity profile coaxial nozzles are compared over a range of operating conditions. The implications of the acoustic benefits derived with the eccentric nozzle to practical applications are discussed.

Goodykoontz, J.↗

Noise suppression due to annulus shaping of conventional coaxial nozzle

A method which shows that increasing the annulus width of a conventional coaxial nozzle with constant bypass velocity will lower the noise level is described. The method entails modifying a concentric coaxial nozzle to provide an eccentric outer stream annulus while maintaining approximately the same through flow as that for the original concentric bypass nozzle. Acoustical tests to determine the noise generating characteristics of the nozzle over a range of flow conditions are described. The tests involved sequentially analyzing the noise signals and digitally recording the 1/3 octave band sound pressure levels. The measurements were made in a plane passing through the minimum and maximum annulus width points, as well as at 90 degrees in this plane, by rotating the outer nozzle about its axis. Representative measured spectral data in the flyover plane for the concentric nozzle obtained at model scale are discussed. Representative spectra for several engine cycles are presented for both the eccentric and concentric nozzles at engine size.

Vonglahn, U.↗

Noise suppression due to annulus shaping of a conventional coaxial nozzle

Previous studies have shown that increasing the annulus width of a conventional coaxial nozzle with constant bypass velocity will lower the noise level. In the present model-scale study, the annulus was shaped by an eccentric mounting of the annular nozzle with respect to the conical core nozzle. Acoustic measurements were made in the flyover plane below the widest portion of the annulus and at 90 deg and 180 deg from this point. The model-scale spectra are scaled up to engine size (1.07 m diameter) and the perceived noise levels for the eccentric and concentric coaxial nozzles are compared over a limited range of operating conditions. The implications of the acoustic benefits derived from the eccentric nozzle to practical applications are discussed.

Von Glahn, U.↗

Noise suppression due to annulus shaping of an inverted-velocity-profile coaxial nozzle

Previous studies have shown that an inverted-velocity-profile coaxial nozzle for use with supersonic cruise aircraft produces less jet noise than an equivalent conical nozzle. Furthermore, decreasing the annulus height (increasing radius ratio with constant flow) results in further noise reduction benefits. In the present model-scale study, the annulus shape, that is, height, was varied by an eccentric mounting of the annular nozzle with respect to a conical core nozzle. Acoustic measurements were made in the flyover plane below the narrowest portion of the annulus and at 90 deg and 180 deg from this point. The model-scale spectra are scaled up to engine size (1.07 m diameter) and the perceived noise levels for the eccentric and baseline concentric inverted-velocity-profile coaxial nozzles are compared over a range of operating conditions. The implications of the acoustic benefits derived with the eccentric nozzle to practical applications are discussed.

Goodykoontz, J.↗

Coaxial phased array antenna

A coaxial antenna array for communicating circularly polarized electromagnetic radiation is disclosed. A pair of open ended antenna cavities is coaxially constructed and operates by excitation of linear radiation elements arranged within each of the cavities. A pair of crossed dipole radiation devices is centered within the inner cavity and operated by means of a phase shifting network circuit to transmit as well as receive circularly polarized radiation. Four monopole radiation devices are symmetrically arranged to operate in the outer cavity in phase quadrature by means of the phase shifting network circuit to both transmit and receive circularly polarized electromagnetic radiation. Combined operation of the two antenna cavities with a 180 deg phase differential between the fields related to the two antenna cavities provides a broad beam, relatively wide frequency bandwidth communication capability. Particular embodiments disclosed feature a generally square cavity array as well as a circular cavity array.

Ellis, H., Jr.↗

Coaxial prime focus feeds for paraboloidal reflectors

A TE11 - TM11 dual mode coaxial feed for use in prime focus paraboloidal antenna systems is investigated. The scattering matrix parameters of the internal bifurcation junction was determined by the residue calculus technique. The scattering parameters and radiation fields of the aperture were found from the Weinstein solution. The optimum modeing ratio for minimum cross-polarization was determined along with the corresponding optimum feed dimensions. A peak cross-polarization level of -58 dB is predicted. The frequency characteristics were also investigated and a bandwidth of 5% is predicted over which the cross-polarization remains below -30 dB, the input VSWR is below 1.15, and the phase error is less than 10 deg. Theoretical radiation patterns and efficiency curves for a paraboloidal reflector illuminated by this feed were computed. The predicted sidelobe level is below -30 dB and aperture efficiencies greater than 70% are possible. Experimental results are also presented that substantiates the theoretical results. In addition, experimental results for a 'short-cup' coaxial feed are given. The report includes extensive design data for the dual-mode feed along with performance curves showing cross-polarization as a function of feed parameters. The feed is useful for low-cost ground based receiving antennas for use in direct television satellite broadcasting service.

Collin, R. E.↗

Parametric analysis of hollow conductor parallel and coaxial transmission lines for high frequency space power distribution

A parametric analysis was performed of transmission cables for transmitting electrical power at high voltage (up to 1000 V) and high frequency (10 to 30 kHz) for high power (100 kW or more) space missions. Large diameter (5 to 30 mm) hollow conductors were considered in closely spaced coaxial configurations and in parallel lines. Formulas were derived to calculate inductance and resistance for these conductors. Curves of cable conductance, mass, inductance, capacitance, resistance, power loss, and temperature were plotted for various conductor diameters, conductor thickness, and alternating current frequencies. An example 5 mm diameter coaxial cable with 0.5 mm conductor thickness was calculated to transmit 100 kW at 1000 Vac, 50 m with a power loss of 1900 W, an inductance of 1.45 micron and a capacitance of 0.07 micron-F. The computer programs written for this analysis are listed in the appendix.

Jeffries, K. S.↗

Seam tracking performance of a Coaxial Weld Vision System and pulsed welding

This report describes a continuation of a series of tests on the Coaxial Weld Vision System at MSFC. The ability of the system to compensate for transients associated with pulsed current welding is analyzed. Using the standard image processing approach for root pass seam tracking, the system is also tested for the ability to track the toe of a previous weld bead, for tracking multiple pass weld joints. This Coaxial Weld Vision System was developed by the Ohio State University (OSU) Center for Welding Research and is a part of the Space Shuttle Main Engine Robotic Welding Development System at MSFC.

Gangl, K. J.↗

Thermal coefficient of delay for various coaxial and fiber-optic cables

Data are presented on the thermal coefficient of delay for various coaxial and fiber optic cables, as measured by the Frequency and Timing Systems Engineering Group and the Time and Frequency Systems Research Group. The measured pressure coefficient of delay is also given for the air-dielectric coaxial cables. A description of the measurement method and a description of each of the cables and its use at JPL and in the DSN are included. An improvement in frequency and phase stability by a factor of ten is possible with the use of fiber optics.

Lutes, G. F.↗

Liquid atomization by coaxial rocket injectors

The atomization characteristics of a scaled-down version of a coaxial rocket injector was investigated using a phase Doppler particle analyzer (PDPA). The injector was operated in the conventional mode with liquid being injected through its inner orifice and gas being injected through its outer annulus. The shearing action occurring at the liquid-gas interface causes the liquid jet to atomize. In this study, two different liquid-air systems, namely a water-air system and a liquid nitrogen-gaseous nitrogen system, were chosen for detailed investigation. This paper discusses the performance characteristics of the coaxial injector under different flow and geometric conditions. Specifically, the effects of injection gas pressure and the injector cavity size on variables such as the mean particle diameter, Sauter mean diameter, number density, volume flux, and velocity have been presented.

Sankar, S. V.↗

ALS LOX/H2 subscale coaxial injector testing

Tests of a 40K subscale LOX/H2 coaxial LOX swirl injector conducted without injector or chamber degradation are reported. Chamber pressures ranged from 1572 to 2355 psia with overall mixture ratios from 5.04 to 6.39. The highest characteristic velocities were measured when the mixture ratio across the injector face was uniform. Scarfing of the outer row LOX posts had the largest effect on chamber heating rates. As a result of the tests, the LSI design was modified to arrange the outer row LOX posts in a circular pattern, eliminate O/F biasing and fuel film cooling, and modify the interpropellant plate to allow for larger pressure differentials during the start and cutoff transients. Testing of a 100 K LOX/H2 coaxial LOX swirl injector involved chamber pressure ranging from 700 to 2500 psia with overall mixture ratios from 3.2 to 8.8. Stable combustion was observed to a fuel temperature of 90R and characteristic velocity efficiencies were good.

Dexter, Carol E.↗

Subscale LOX/hydrogen testing with a modular chamber and a swirl coaxial injector

To support basic injector and chamber technology, the response of a modular calorimeter chamber to an injector with swirl coaxial elements was investigated. The tests supported both the Advanced Launch System (ALS) and the Space Shuttle Main Engine programs. Original test plans included chamber pressures up to 2250 psia, the current ALS engine criteria, but hardware limitations forced conditions to be reduced. With four different chamber configurations, a variety of data was obtained with chamber pressures ranging from 1483 psia to 1679 psia and mixture ratios from 5.24 to 6.90. The swirl coaxial injector showed good chamber wall compatibility, despite misaligned elements, and its high performance was independent of fuel. Heating rates and wall temperatures were acceptable and close to predict profiles, and after scaling to a chamber pressure of 2250 psia, heating rates remained acceptable. In addition, a chamber spool made with the vacuum plasma spray process survived hot-fire testing with no detrimental effects.

Elam, Sandra K.↗

Initial drop size and velocity distributions for airblast coaxial atomizers

Phase Doppler measurements were used to determine initial drop size and velocity distributions after a complete disintegration of coaxial liquid jets. The Sauter mean diameter (SMD) distribution was found to be strongly affected by the structure and behavior of the preceding liquid intact jet. The axial measurement stations were determined from the photographs of the coaxial liquid jet at very short distances (1-2 mm) downstream of the observed break-up locations. Minimum droplet mean velocities were found at the center, and maximum velocities were near the spray boundary. Size-velocity correlations show that the velocity of larger drops did not change with drop size. Drop rms velocity distributions have double peaks whose radial positions coincide with the maximum mean velocity gradients.

Eroglu, H.↗

Coaxial line configuration for microwave power transmission study of YBa2Cu3O(7-delta) thin films

Microwave transmission measurements through YBa2Cu3O(7-delta) (YBCO) high-transition-temperature superconducting thin films on lanthanum aluminate (LaAlO3) have been performed in a coaxial line at 10 GHz. LaAlO3 substrates were ultrasonically machined into washer-shaped discs, polished, and coated with laser-ablated YBCO. These samples were mounted in a 50-ohm coaxial air line to form a short circuit. The power transmitted through the films as a function of temperature was used to calculate the normal state conductivity and the magnetic penetration depth for the films.

Chorey, C. M.↗

Characterization of coaxial rocket injector sprays under high pressure environments

The effect of elevated environment pressures on the atomization characteristics of a single element, scaled-down, shear-coaxial rocket injector has been investigated. In this study, the shear coaxial injector was operated with water and air as simulants for conventionally used liquid oxygen and hydrogen gas, respectively. The experiments were conducted in a specially designed high pressure rig. A two-component PDPA/DSA system was used to study the spray characteristics at different chamber pressures ranging from atmospheric to 100 psig. The study showed an overall increase in the droplet sizes at higher chamber pressures. This phenomenon is attributed to a decrease in the secondary atomization effects at higher chamber pressures which, in turn, is directly related to a decrease in the shear experienced by the droplets as they move axially through the pressure chamber.

Sankar, S. V.↗

Preliminary investigation of power flow and electrode phenomena in a multi-megawatt coaxial plasma thruster

The present report on preliminary results of theoretical and experimental investigations of power flow in a large, unoptimized, multimegawatt coaxial thruster evaluates the significance of these data for the development of efficient, megawatt-class magnetoplasmadynamic (MPD) thrusters. The good agreement obtained between thruster operational performance and model predictions suggests that ideal MHD processes, including those of a magnetic nozzle, play an important role in coaxial plasma thruster dynamics at power levels relevant to advanced space propulsion. An optimized magnetic nozzle design would aid the development of efficient, multimegawatt MPD thrusters.

Schoenberg, Kurt F.↗