Search NASA⌕ Search

SEARCH · Search NASA

Results for “Coincidence counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A new algorithm for estimating radioxenon concentrations

A new algorithm (Xcounts) is introduced for estimating the activity concentrations of the xenon isotopes 131m Xe, 133m Xe, 133 Xe, and 135 Xe using beta-gamma coincidence data. The algorithm simultaneously estimates the decay counts associated with the four xenon isotopes, background, and radon in contrast to the net-counts method that uses sequential residual removal to account for background and interreferences. Calibration data for background counts are determined from gas-background measurements and simulation. In Xcounts, the false positive count rates for 131m Xe and 133m Xe are lower than the false positive rates for 133 Xe and 135 Xe. This algorithm appears to reliably detect the metastable isotopes at lower activity levels than the net-counts method and have similar performance for the other isotopes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast event-based electron counting for small-molecule structure determination by MicroED

Electron counting helped realize the resolution revolution in single-particle cryoEM and is now accelerating the determination of MicroED structures. Its advantages are best demonstrated by new direct electron detectors capable of fast (kilohertz) event-based electron counting (EBEC). This strategy minimizes the inaccuracies introduced by coincidence loss (CL) and promises rapid determination of accurate structures. We used the Direct Electron Apollo camera to leverage EBEC technology for MicroED data collection. Given its ability to count single electrons, the Apollo collects high-quality MicroED data from organic small-molecule crystals illuminated with incident electron beam flux densities as low as 0.01–0.045 e − /Å 2 /s. Under even the lowest flux density (0.01 e − /Å 2 /s) condition, fast EBEC data produced ab initio structures of a salen ligand (268 Da) and biotin (244 Da). Each structure was determined from a 100° wedge of data collected from a single crystal in as few as 50 s, with a delivered fluence of only ∼0.5 e − /Å 2 . Fast EBEC data collected with a fluence of 2.25 or 3.33 e − /Å 2 also facilitated a 1.5 Å structure of thiostrepton (1665 Da). While refinement of these structures appeared unaffected by CL, a CL adjustment applied to EBEC data further improved the distribution of intensities measured from the salen ligand and biotin crystals. However, CL adjustment only marginally improved the refinement of their corresponding structures, signaling the already high counting accuracy of detectors with counting rates in the kilohertz range. Overall, by delivering low-dose structure-worthy data, fast EBEC collection strategies open new possibilities for high-throughput MicroED.

EBEC↗

Distinguishing fissile uranium isotopes using an active well neutron coincidence counter

Proposed thorium-based nuclear fuel cycles are likely to require quantification and verification of 233 U within nuclear material. Because of their similar fission cross sections, active neutron nondestructive assay (NDA) systems may respond similarly to 233 U and 235 U. Traditional safeguards equipment has been optimized for 235 U and 238 U quantification associated with conventional uranium/plutonium fuel cycles and may not be directly applicable to 233 U quantification when mixed with other actinides. This work used models of the large volume active well coincidence counter (LV-AWCC) at Oak Ridge National Laboratory to evaluate the performance of this neutron NDA system to differentiate fissile uranium isotopes. The models were developed to simulate NDA system performance in response to a number of triangular radiation signature training device sources within the central cavity or well. This work predicted that the LV-AWCC can effectively differentiate 233 U from 235 U in certain modes of operation. In active mode, the LV-AWCC with the cadmium liner results in different doubles count rates between the fissile isotopes for a given fissile uranium mass. Without the cadmium liner, the uranium isotopes provide a statistically indistinguishable doubles count rate response for the fissile masses considered in this work (up to approximately 150 g). The cadmium liner serves to harden the neutron interrogation spectrum, which better exploits the notable difference in the 233 U and 235 U fission cross sections at approximately 1 eV. In passive mode, the two fissile isotopes exhibit different doubles and singles count rates regardless of liner presence because the passive source strength of 233 U is approximately 2 orders of magnitude stronger than that of 235 U due to the shorter half-life and correspondingly higher (α, n) yield. We conclude that using neutron interrogation in the LV-AWCC, two measurements are needed to quantify 233 U content in mixed uranium items. The first measurement is used to determine the total fissile uranium mass using a mode that cannot distinguish fissile isotopes (i.e., where a similar response is observed for both fissile uranium isotopes such as active doubles without cadmium or using a thermal neutron interrogation source). In conclusion, the second measurement is used to determine the 233 U content by using a differentiating technique (e.g., passive doubles, passive doubles to singles ratio, active doubles with cadmium).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep Learning Approach for High-accuracy Electron Counting of Monolithic Active Pixel Sensor-type Direct Electron Detectors at Increased Electron Dose

Abstract Electron counting can be performed algorithmically for monolithic active pixel sensor direct electron detectors to eliminate readout noise and Landau noise arising from the variability in the amount of deposited energy for each electron. Errors in existing counting algorithms include mistakenly counting a multielectron strike as a single electron event, and inaccurately locating the incident position of the electron due to lateral spread of deposited energy and dark noise. Here, we report a supervised deep learning (DL) approach based on Faster region-based convolutional neural network (R-CNN) to recognize single electron events at varying electron doses and voltages. The DL approach shows high accuracy according to the near-ideal modulation transfer function (MTF) and detector quantum efficiency for sparse images. It predicts, on average, 0.47 pixel deviation from the incident positions for 200 kV electrons versus 0.59 pixel using the conventional counting method. The DL approach also shows better robustness against coincidence loss as the electron dose increases, maintaining the MTF at half Nyquist frequency above 0.83 as the electron density increases to 0.06 e−/pixel. Thus, the DL model extends the advantages of counting analysis to higher dose rates than conventional methods.

Materials Science↗

233 U oxide Measurement Campaign Data: Passive and Active Neutron Multiplicity Measurements of Uranium Oxide Samples at Oak Ridge National Laboratory

During FY2023, three measurement campaigns were conducted at Oak Ridge National Laboratory. The goal was to quantify the neutron signatures of samples of uranium oxide containing uranium 233 and uranium-235. This report presents the neutron multiplicity data obtained using the large volume active well coincidence counter (LV-AWCC).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A PIPS + SrI 2 (Eu) detector for atmospheric radioxenon monitoring

The PIPS–SrI 2 (Eu) is a prototype atmospheric radioxenon detection system designed at Oregon State University in support of international efforts towards monitoring clandestine nuclear weapon testing activities. This detector aims to address some shortcomings found in currently deployed beta–gamma atmospheric radioxenon detection systems, such as lackluster energy resolution and memory effect, by employing modern detection materials and readout. The system uses a PIPSBox, a silicon-based gas cell, for electron detection, and a pair of ultrabright, D-shaped SrI 2 (Eu) scintillators coupled to silicon photomultipliers for photon detection. A custom eight-channel digital pulse processor equipped with a field programmable gate-array (FPGA) identifies electron–photon coincidences between the volumes in near real-time. Gas samples of the four radioxenon isotopes of interest were independently measured with the PIPS–SrI 2 (Eu) detection system to determine energy resolution and efficiency. Application of FPGA-based coincidence discrimination in near real-time reduced the ambient background count rate by 95.85 ± 0.04%. Using parameters from the Xenon International gas processing unit and assuming a blank sample and zero memory effect the minimum detectable concentrations (MDCs) for the isotopes were calculated to be 0.12 ± 0.03, 0.27 ± 0.05, 0.15 ± 0.02, and 1.00 ± 0.08 mBq/m 3 air for 131m Xe, 133 Xe, 133m Xe, and 135 Xe, respectively. These MDC estimates compare well with other radioxenon detection systems employed in the International Monitoring System (IMS) and indicate that the PIPS–SrI 2 (Eu) is in compliance with the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO) sensitivity requirement of ≤ 1 mBq/m 3 for 133 Xe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Statistical Validation of Multiple Related Data Sets—Case Study Using Interstellar Boundary Explorer Satellite Data

Abstract Space scientists often face the question of whether data collected by different instruments are measurements of the same source population. This paper proposes a statistical validation method for evaluating the agreement between such related data sets. It offers a detailed case study focused on validating a new data set from the Interstellar Boundary Explorer (IBEX) mission, which serves as a practical how-to guide for similar analyses. Since 2008, the IBEX satellite has been gathering data on heliospheric energetic neutral atoms (ENAs) while being exposed to various sources of background noise, such as cosmic rays and solar energetic particles. The IBEX mission initially released only a qualified triple-coincidence (qABC) data product, which was designed to provide observations of ENAs free of background contamination. Further measurements revealed that the qABC data were in fact susceptible to contamination, having relatively low ENA counts and high background rates. To mitigate this issue, the mission team recently considered releasing a certain qualified double-coincidence (qBC) data product, which has roughly twice the detection rate of the qABC data product. This paper presents a simulation-based validation of the new qBC data product against the already-released qABC data product. The results show that the qBCs can plausibly be said to be measuring the same source population as the qABCs up to an average absolute deviation of 3.6%. Visual diagnostics provide additional confirmation of source rate coherence across data products. The framework introduced here is general and can be applied to other validation problems both within and outside the field of space physics.

79 ASTRONOMY AND ASTROPHYSICS↗

High-count-rate effects in event processing for the XRISM/Resolve X-ray microcalorimeter. II. Energy scale and resolution in orbit

The Resolve instrument on the X-ray Imaging and Spectroscopy Mission (XRISM) uses a 36 pixel microcalorimeter designed to deliver high-resolution, non-dispersive X-ray spectroscopy. Although it is optimized for extended sources with low count rates, Resolve observations of bright point sources are still able to provide unique insights into the physics of these objects, as long as high-count-rate effects are addressed in the analysis. These effects include the loss of exposure time for each pixel, changes in the energy scale, and changes in the energy resolution. To investigate these effects under realistic observational conditions, we observed the bright X-ray source, the Crab Nebula, with XRISM at several offset positions with respect to the Resolve field of view and with continuous illumination from 55 Fe sources on the filter wheel. For the spectral analysis, we excluded data where exposure-time loss was too significant to ensure reliable spectral statistics. The energy scale at 6 keV shows a slight negative shift in the high-count-rate regime. The energy resolution at 6 keV worsens as the count rate in electrically neighboring pixels increases, but can be restored by applying a nearest-neighbor coincidence cut (“cross-talk cut”). We examined how these effects influence the observation of bright point sources, using GX 13+1 as a test case, and identified an eV-scale energy offset at 6 keV between the inner (brighter) and outer (fainter) pixels. Users who seek to analyze velocity structures on the order of tens of km s–1 should account for such high-count-rate effects. These findings will aid in the interpretation of Resolve data from bright sources and provide valuable considerations for designing and planning for future microcalorimeter missions.

X-rays: general↗

$\mathrm{α}$ decay of the longest-lived Cm isotope: $^{247}_{96}\mathrm{Cm}$

We report alpha decay of 247 Cm was studied fifty years ago using a 1.6 Bq source containing 99.4 % 247 Cm and levels in 243 Pu were deduced. Using the same source, γ-ray spectra were measured with a more efficient Ge detector. A γ-ray spectrum was also measured in coincidence with α particles for a period of two months and has 80 times more counts than the previously published spectrum. Gamma-ray energies were determined with higher precision and four new γ rays were identified. A new high-energy γ ray of 564.5 keV was observed, which is interpreted as a transition between a level at 564.5 keV and the ground state of 243 Pu. The 564.5-keV level has been tentatively assigned to the 7/2 - [743] Nilsson state.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of cosmogenic activation above ground for the DarkSide-20k experiment

The activation of materials due to exposure to cosmic rays may become an important background source for experiments investigating rare event phenomena. DarkSide-20k, currently under construction at the Laboratori Nazionali del Gran Sasso, is a direct detection experiment for galactic dark matter particles, using a two-phase liquid-argon Time Projection Chamber (TPC) filled with 49.7 tonnes (active mass) of Underground Argon (UAr) depleted in 39 Ar. Despite the outstanding capability of discriminating γ / β background in argon TPCs, this background must be considered because of induced dead time or accidental coincidences mimicking dark-matter signals and it is relevant for low-threshold electron-counting measurements. Here, the cosmogenic activity of relevant long-lived radioisotopes induced in the experiment has been estimated to set requirements and procedures during preparation of the experiment and to check that it is not dominant over primordial radioactivity; particular attention has been paid to the activation of the 120 t of UAr used in DarkSide-20k. Expected exposures above ground and production rates, either measured or calculated, have been considered in detail. From the simulated counting rates in the detector due to cosmogenic isotopes, it is concluded that activation in copper and stainless steel is not problematic. The activity of 39 Ar induced during extraction, purification and transport on surface is evaluated to be 2.8% of the activity measured in UAr by DarkSide-50 experiment, which used the same underground source, and thus considered acceptable. Other isotopes in the UAr such as 37 Ar and 3 H are shown not to be relevant due to short half-life and assumed purification methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Integrated Approach to Precision Neutron Measurements in a Dynamic Environment [Slides]

Any quantity of special nuclear material must be accurately quantified for health, safety, and security concerns. High-Level Neutron Coincidence Counters (HLNCCs) are detectors used for assaying the mass of special nuclear material. HLNCCs record a neutron count rate over some period of time which is compared to a calibration curve to determine the quantity of special nuclear material present within the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon counting with intensified charge coupled device (ICCD) – II. Laser induced breakdown spectroscopy (LIBS) spectral measurement

This study explores the application of photon counting (PC) to enhance the resolution of spectra acquired by an intensified charge-coupled device (ICCD) detector, with a focus on analytical atomic emission spectrometry using laser-induced breakdown spectroscopy (LIBS) as a use-case example. It demonstrates that, for spectra obtained with the same spectrometer–ICCD system, PC provides higher spectral resolution compared to conventional analog detector readout. This enhancement is particularly evident in the line wings of spectral peaks, facilitating better discrimination of isotopic peaks in the measured spectra. Although PC does not improve the resolution of an optical spectrometer directly, it rectifies the resolution lost caused by signal spreading in conventional ICCD analog measurement. However, similar to other counting techniques, excessive photons compromise detector linearity due to signal pileup. A correction model is proposed to mitigate the pileup effect, resulting in improved linearity and dynamic range in PC measurements. Additionally, the study reveals unexpected periodic structures in the flatfield image of the ICCD, which cause non-uniform detector gain in conventional analog as well as PC measurement modes and must be addressed for high-precision measurements.

47 OTHER INSTRUMENTATION↗

Estimation of Possible Primary Biological Particle Emissions and Rupture Events at the Southern Great Plains ARM Site

We use 10 years of data from the Department of Energy (DoE) Atmospheric Radiation Measurements (ARM) United States Southern Great Plains (SGP) site with nearby regional pollen and fungal spore measurements to indirectly estimate the seasonal influence of these two primary biological aerosol particles (PBAP). We estimate possible primary emissions of larger PBAP and PBAP rupture events, which form submicron organic aerosol during precipitation or high relative humidity. High pollen counts at two urban stations near SGP occur during late winter/early spring (day of year (DOY) 50–120) and late summer (DOY 240–310). Around 4–19 days per year show possible pollen events (PPE) when near-surface lidar observations of daily linear particle depolarization ratio >0.1 are coincident with high organic aerosol fraction. For PPE days with rainfall, aerosol size distribution observations show enhanced submicron particle concentrations consistent with pollen rupture events. For fungal spores, high fungal spore counts occur during late spring/early summer (DOY 110–195) and late summer/autumn (DOY 220–340). Based on size distribution observations, up to 7% of days have possible fungal spore rupture events (PFE) with higher aerosol number count specifically over the range expected for fungal spore fragment mobility diameter (20–50 nm). These short-lived PFE correlate with rainfall or occur after prolonged exposure to rainfall (e.g., >10 h). While the SGP site lacks direct measurements of bioaerosol and large particle sizes, this analysis suggests that PBAP primary emissions and rupture events could occur about 32 days per year, representing an important component of the aerosol budget during seasonal emissions.

54 ENVIRONMENTAL SCIENCES↗

Improvements to the 115g/115m Cd Nuclear Data

Repeated measurements of the isotope 115m Cd by Los Alamos National Laboratory (LANL), Pacific Northwest National Laboratory (PNNL), and Atomic Weapons Establishment (AWE) have revealed a consistent discrepancy between beta and gamma counting. This suggests that a significant disparity exists between the true value of the isotope’s gamma-ray branching ratios and the values reported by the National Nuclear Data Center (NNDC). Enriched 114 Cd was irradiated using thermal neutrons to produce a high-purity 115m/g Cd source for counting and analysis using traditional singles gamma-ray spectroscopy, liquid scintillation counting, gas-proportional counting, and analysis using the new Gamma-Alpha-Beta-Gamma (GABγ) and Gamma-Alpha-Beta Radio-Isotope EvaLuator (GABRIEL) coincidence detection systems. Using the D-T fusion generated neutrons, reduces the wait time required to let the short-lived 115Cd ground state decay away by leveraging the 1:1 production ratio of the ground and metastable state of 115 Cd from the 115 In (n,p) reaction relative to the 10:1 production ratio of the ground and metastable isotopes of 115 Cd by thermal neutron capture on 114 Cd. However, the much higher flux in from the Washington State University TRIGA reactor is a more rapid method of production of 115m/gCd but requires access to enriched 114 Cd. High purity 115m/g Cd samples were analyzed on regular intervals over a period of 140-days. The activity of 115m Cd measured by beta and gamma show a clear discrepancy using the current best known gamma-ray decay branching ratios. Based on these observations and measurements, a set of new branching ratio recommendations have been produced using conventional counting techniques and the advanced GAB? and GABRIEL instruments.

07 ISOTOPE AND RADIATION SOURCES↗

Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET

Objective. Standard signal processing approaches for scintillation detectors in positron emission tomography (PET) derive accurate estimates for 511 keV photon time of interaction and energy imparted to the detection media from aggregate characteristics of electronic pulse shapes. The ultimate realization of a scintillation detector for PET is one that provides a unique timestamp and position for each detected scintillation photon. Detectors with these capabilities enable advanced concepts for three-dimensional (3D) position and time of interaction estimation with methods that exploit the spatiotemporal arrival time kinetics of individual scintillation photons. Approach. In this work, we show that taking into consideration the temporal photon emission density of a scintillator, the channel density of an analog silicon photomultiplier (SiPM) array, and employing fast electronic readout with digital signal processing, a detector that counts and timestamps scintillation photons can be realized. To demonstrate this approach, a prototype detector was constructed, comprising multichannel electronic readout for a bismuth germanate (BGO) scintillator coupled to an SiPM array. Main Results. In proof-of-concept measurements with this detector, we were able to count and provide unique timestamps for 66% of all optical photons, where the remaining 34% (two-or-more-photon pulses) are also independently counted, but each photon bunch shares a common timestamp. We show this detector concept can implement 3D positioning of 511 keV photon interactions and thereby enable corrections for time of interaction estimators. The detector achieved 17.6% energy resolution at 511 keV and 237 ± 10 ps full-width-at-half-maximum coincidence time resolution (CTR) (fast spectral component) versus a reference detector. We outline the methodology, readout, and approach for achieving this detector capability in first-ever, proof-of-concept measurements for scintillation photon counting detector with analog silicon photomultipliers. Significance. The presented detector concept is a promising design for large area, high sensitivity TOF-PET detector modules that can implement advanced event positioning and time of interaction estimators, which could push state-of-the-art performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reduction of detection limit and quantification uncertainty due to interferent by neural classification with abstention

Many measurements in the physical sciences can be cast as counting experiments, where the number of occurrences of a physical phenomenon informs the prevalence of the phenomenon's source. Often, detection of the physical phenomenon (termed signal) is difficult to distinguish from naturally occurring phenomena (termed background). In this case, the discrimination of signal events from background can be performed using classifiers, and they may range from simple, threshold-based classifiers to sophisticated neural networks. These classifiers are often trained and validated to obtain optimal accuracy, however we show that the optimal accuracy classifier does not generally coincide with a classifier that provides the lowest detection limit, nor the lowest quantification uncertainty. Here, we present a derivation of the detection limit and quantification uncertainty in the classifier-based counting experiment case. We also present a novel abstention mechanism to minimize the detection limit or quantification uncertainty a posteriori. We illustrate the method on two data sets from the physical sciences, discriminating Ar-37 and Ar-39 radioactive decay from non-radioactive events in a gas proportional counter, and discriminating neutrons from gammas in an inorganic scintillator and report results therefrom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high-resolution record of Late Holocene drought in the eastern Sierra Nevada (California, USA) from June Lake carbonate geochemistry

As historic drought conditions become more common in western North America, Late Quaternary hydroclimate records become vital for putting present anthropogenic conditions into a longer-term context. Here, we establish a high-resolution record of drought for the eastern Sierra Nevada (California) using lacustrine carbonates from well-dated sediment cores. We used oxygen and carbon stable-isotope ratios, combined with high-resolution scanning X-ray fluorescence counts of calcium (Ca) and titanium (Ti), to reconstruct the drought record over the last 4600 years in June Lake. We found elevated δ 18 O and δ 13 C carbonate isotope values coinciding with peaks in both total inorganic carbon and Ca/Ti, suggesting enhanced carbonate precipitation in response to evaporative concentration of lake water. At least six intervals of prolonged (centennial-scale) carbonate deposition were identified, including three pulses during the Late Holocene Dry Period (LHDP; ~3500–2000 cal yr BP), the Medieval Climate Anomaly (~1200–800 cal yr BP), and the Current Warm Period, which began around 100 cal yr BP. This record highlights the complexities of the LHDP, an interval that was more variable at June Lake than has been previously described in regional records.

54 ENVIRONMENTAL SCIENCES↗

Precision test of statistical dynamics with state-to-state ultracold chemistry

Chemical reactions represent a class of quantum problems that challenge both the current theoretical understanding and computational capabilities1. Reactions that occur at ultralow temperatures provide an ideal testing ground for quantum chemistry and scattering theories, because they can be experimentally studied with unprecedented control, yet display dynamics that are highly complex. Here we report the full product state distribution for the reaction 2KRb → K 2 + Rb 2 . Ultracold preparation of the reactants allows us complete control over their initial quantum degrees of freedom, whereas state-resolved, coincident detection of both products enables the probability of scattering into each of the 57 allowed rotational state-pairs to be measured. Our results show an overall agreement with a state-counting model based on statistical theory, but also reveal several deviating state-pairs. In particular, we observe a strong suppression of population in the state-pair closest to the exoergicity limit as a result of the long-range potential inhibiting the escape of products. Finally, the completeness of our measurements provides a benchmark for quantum dynamics calculations beyond the current state of the art.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗