Search NASA⌕ Search

SEARCH · Search NASA

Results for “Combined effect testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Effects of Coatings on Water Intrusion and Strain Gauge Durability in Submerged Fatigue Conditions: Preprint

Marine energy structures are typically made using composite materials and are repeatedly loaded by currents and waves. Submersion and repeated loading lead to two environmental effects: moisture intrusion and mechanical fatigue. To understand the combined effects of moisture intrusion and mechanical fatigue on marine energy structures, submerged fatigue testing can be used. Submerged fatigue testing often requires submerged instrumentation to validate component manufacturing methods and models. Measuring strain is critical for understanding marine energy component loads. One common method for measuring strain is by using foil strain gauges, but the durability of strain gauges in submerged fatigue conditions was not well-understood. To increase strain gauge durability and protection from contamination, delamination, and water intrusion, strain gauge coatings may be applied over strain gauges and wire connections. In this study, strain gauges were adhered to composite coupons, coated, and mechanically tested in a water tank. Cycles to composite failure, cycles to strain gauge failure, strains, and strain gauge failure modes were used to measure the effects of strain gauge coatings on composite fatigue life and strain gauge durability. The methods developed and measurements taken at the coupon scale in this study will be used to inform methods and designs for subsequent submerged subcomponent testing, full-scale testing, and standards development. The benefits of designing marine energy structures to informed standards and designs are decreased lifetime costs and increased reliability and energy production, ultimately leading to a sustainable and low-carbon energy system.

composite fatigue testing↗

Pool Boiling Reliability Tests and Degradation Mechanisms of Microporous Copper Inverse Opal (CuIOs) Structures

The rising power density in electronic systems requires thermal management solutions that are both high-performing and reliable. Porous materials such as Copper Inverse Opal (CuIOs) have unique structural features, including high permeability and high thermal conductivity, to enhance pool boiling performance. However, there is little understanding of the degradation mechanism of such porous materials under pool boiling conditions. In this study, samples of 10 ..mu..m thick CuIOs with 4.8 ..mu..m diameter, covering silicon substrate of area 11 mm x 11 mm, with various heated areas ranging from 2.5 mm x 2.5 mm to 10 mm x 10 mm, were tested in 100 degrees C deionized water at a constant heat flux of 110 Wcm -2 for 3-to-7 days. The combined effect of erosion and corrosion caused structural degradation of the CuIOs. The directly heated area had the most severe degradation while the edge of the heater and the unheated area showed progressively less degradation, maintaining some CuIOs structure even after the 7-day reliability test. Among all the tested samples with various heater sizes, the 2.5 mm x 2.5 mm heater sample - in which the heater size was designed to be comparable to the water bubble characteristic length - had the largest critical heat flux (CHF) up to 300 Wcm -2 with a superheat ~ 13 degrees C. Additionally, CuIOs with a smaller heated area performed better in terms of reliability. This study offers preliminary insights into CuIOs degradation mechanisms, contributing to the development of more robust thermal management solutions. We expect that electroless plating of CuIOs with gold (Au), nickel (Ni), and atomic layer deposition (ALD) aluminum oxide (Al 2 O 3 ) in combination with appropriate application-specific coolants will further improve the reliability and lifetime of the CuIOs.

boiling-induced degradation↗

Pool Boiling Reliability Tests and Degradation Mechanisms of Microporous Copper Inverse Opal (CuIOs) Structures: Preprint

The rising power density in electronic systems requires thermal management solutions that are both high-performing and reliable. Porous materials such as Copper Inverse Opals (CuIOs) have unique structural features, including high permeability and high thermal conductivity, to enhance pool boiling performance. However, there is little understanding of the degradation mechanism of such porous materials under pool boiling conditions. In this study, samples of 10-micrometer-thick CuIOs with 4.8-micrometer diameter, covering silicon substrate of area 11-mm by 11-mm, with various heated areas ranging from 2.5-mm by 2.5-mm to 10-mm by 10-mm, were tested in 100 degrees C deionized water at a constant heat flux of 110 watts per square cm for 3-7 days. The combined effect of erosion and corrosion caused structural degradation of the CuIOs. The directly heated area had the most severe degradation while the edge of the heater and the unheated area showed progressively less degradation, maintaining some CuIOs structure even after the 7-day reliability test. Among all the tested samples with various heater sizes, the 2.5-mm by 2.5-mm heater sample - in which the heater size was designed to be comparable to the water bubble characteristic length - had the largest critical heat flux (CHF) up to 300 watts per square cm with a superheat of approximately 13 degrees C. Additionally, CuIOs with a smaller heated area performed better in terms of reliability. This study offers preliminary insights into CuIOs degradation mechanisms, contributing to the development of more robust thermal management solutions. We expect that electroless plating of CuIOs with gold (Au), nickel (Ni), and atomic layer deposition of aluminum oxide in combination with appropriate application-specific coolants will further improve the reliability and lifetime of the CuIOs.

boiling-induced degradation↗

Regulating Anionic Redox via Mg Substitution in Mn-Rich Layered Oxide Cathodes Enabling High Electrochemical Stability for Sodium-Ion Batteries

Here, with the limited resources and high cost of lithium-ion batteries (LIBs) and the ever-increasing market demands, sodium-ion batteries (SIBs) gain much interest due to their economical sustainability, and similar chemistry and manufacturing processes to LIBs. As cathodes play a vital role in determining the energy density of SIBs, Mn-based layered oxides are promising cathodes due to their low cost, environmental friendliness, and high theoretical capacity. However, the main challenge is structural instability upon cycling at high voltage. Herein, Mg is introduced into the P2-type Na 0.62 Ni 0.25 Mn 0.75 O 2 cathode to enhance electrochemical stability. By combining electrochemical testing and material characterizations, it is found that substituting 10 mol% Mg can effectively alleviate the P2–O2 phase transition, Jahn-Teller distortion, and irreversible oxygen redox. Moreover, structural integrity is greatly improved. These lead to enhanced electrochemical performances. With the optimized sample, a remarkable capacity retention of 92% in the half cell after 100 cycles and 95% in the full cell after 170 cycles can be achieved. Altogether, this work provides an alternative way to stabilize P2-type Mn-based layer oxide cathodes, which in turn, put forward the development of this material for the next-generation SIBs.

25 ENERGY STORAGE↗

Clear as mud redefined: Tunable transparent mineral scaffolds for visualizing microbial processes below ground

Microbes inhabiting complex porous microenvironments in sediments and aquifers catalyze reactions that are critical to global biogeochemical cycles and ecosystem health. However, the opacity and complexity of porous sediment and rock matrices have considerably hindered the study of microbial processes occurring within these habitats. Here, we generated microbially compatible, optically transparent mineral scaffolds to visualize and investigate microbial colonization and activities occurring in these environments, in laboratory settings and in situ. Using inexpensive synthetic cryolite mineral, we produced optically transparent scaffolds mimicking the complex 3D structure of sediments and rocks by adapting a suspension-based, freeze-casting technique commonly used in materials science. Fine-tuning of parameters, such as freezing rate and choice of solvent, provided full control of pore size and architecture. The combined effects of scaffold porosity and structure on the movement of microbe-sized particles, tested using velocity tracking of fluorescent beads, showed diverse yet reproducible behaviors. The scaffolds we produced are compatible with epifluorescence microscopy, allowing the fluorescence-based identification of colonizing microbes by DNA-based staining and fluorescence in situ hybridization (FISH) to depths of 100 µm. Additionally, Raman spectroscopy analysis indicates minimal background signal in regions used for measuring deuterium and 13 C enrichment in microorganisms, highlighting the potential to directly couple D 2 O or 13 C stable isotope probing and Raman-FISH for quantifying microbial activity at the single-cell level. To demonstrate the relevance of cryolite scaffolds for environmental field studies, we visualized their colonization by diverse microorganisms within rhizosphere sediments of a coastal seagrass plant using epifluorescence microscopy. The tool presented here enables highly resolved, spatially explicit, and multimodal investigations into the distribution, activities, and interactions of underground microbes typically obscured within opaque geological materials until now.

36 MATERIALS SCIENCE↗

Metal Oxide Varistor (MOV) Lifetime Estimation with Impulse-Based Testing in PV Inverter Systems: Preprint

Surges caused by lightning strikes could damage electrical components in photovoltaic (PV) systems. Metal oxide varistors (MOVs) are commonly used to protect PV systems from lightning strikes. In this paper, a holistic impulse-based MOV lifetime estimation framework is proposed. The impacts of peak current and fault duration induced by lightning events are considered in the MOV lifetime estimation framework. Moreover, the impact of different parameter combinations on MOV lifetime estimation is analyzed. The effectiveness of the proposed work is validated in a PV inverter test system developed in MATLAB/Simulink.

lifetime estimation↗

Utility Combined Heat and Power (CHP) Programs

This issue brief provides an overview of energy efficiency portfolios offered by electric and gas utilities that include CHP incentive programs, with examples of program drivers, structures, and eligibility criteria. The document discusses best practices for designing and administering a utility CHP incentive program, including cost-effectiveness tests and market outreach strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Understanding the limitations and potential of micro tensile testing of tungsten and needs for crystal plasticity modelling

Tungsten is the leading plasma facing material candidate due to its exceptional properties. Understanding the response to neutron irradiation is crucial for the lifetime evaluation of tungsten. The limited space in nuclear reactors and the high levels of radioactivity of the specimens after irradiation are significant barriers to accurately measuring the mechanical properties after neutron irradiation. Testing of micro tensile specimens is one approach to reduce the total amount of irradiated material needed for a set of mechanical testing experiments. However, micro samples are not necessarily measuring the bulk material properties, as size effects produce higher measured mechanical properties than is observed in engineering size counterparts. Determining the minimal sample size for reliable bulk property measurement, combined with modeling efforts, is essential. We conducted room temperature tensile tests on tungsten micro tensile specimens fabricated with focused ion beam, plasma focused ion beam and femto-second laser ablation system to dimension of 2×2×7?µm³, 7×7×18?µm³, and 80×100×233?µm³ (width×thickness×gauge-length), respectively. Elevated tensile testing was performed up to 475°C on 5×5×18?µm³ specimens fabricated with focused ion beam. The smallest specimens exhibited a high degree of ductility and strength, whereas the largest specimens demonstrated behavior akin to bulk tungsten. To investigate the effects introduced by the micro specimen fabrication processes and to obtain the necessary bulk dislocation density for the crystal plasticity model, we employed X-ray diffraction depth profiling. This measurement was performed using different X-ray sources with varying penetration depths. Finally, the potential and limitations of micro mechanical tests for tungsten will be discussed.

36 - MATERIALS SCIENCE↗

The estimation of Poisson’s ratio by time-averaging and Cornu’s method for isotropic beams

Prior research suggests that direct static (e.g., uniaxial testing) and dynamic (e.g., ultrasonic wave propagation analysis) measurements differ in the estimation of Poisson’s ratio because anisotropies and heterogeneities in the sample material affect the two types of tests differently. Even assuming isotropic and homogeneous material properties, prior research further suggests that discrepancies between static/dynamic test results will exist because the error of the diagnostic techniques for the measurand are inherently different. Finally, thermodynamic effects are not present in static tests but can significantly affect dynamic test results. Given the potential for all these variables to produce discrepancies, it would be helpful to have the measurement of Poisson’s ratio obtainable from the same theory and experimental measurements by either static or dynamic testing methods. Our finite element calculations show that by combining time-averaged scanning digital holography with Cornu’s method, it is theoretically possible to estimate the effective Poisson’s ratio from the anticlastic contours at the antinode of the first out-of-plane bending mode shape. This is true regardless of frequency and therefore applicable for both static and dynamic measurements. Our results show that the estimate of Poisson’s ratio by Cornu’s method using data from simulations of mode shapes approaches the true value of Poisson’s ratio. Additionally, our research suggests that beam geometry and boundary conditions are fundamental factors limiting the convergence of the estimate of Poisson’s ratio to the true value of Poisson’s ratio regardless of performing a static or dynamic test.

42 ENGINEERING↗

Unraveling the Combined Photothermal Stability of Common Perovskite Solar Cell Compositions

In halide perovskite solar cells, certain compositions, especially those with a high mixture of anions, degrade rapidly. Here, in this study, a degradation study compares the photo (exposure to light), thermal (exposure to elevated temperatures), and photo-plus-thermal (combination) stability of three representative perovskite compositions chosen for their relatively high performance and to independently test anion versus cation effects. Based upon experience and reports, the compositions studied are triple cation with a high Br ratio (Cs 0.05 (FA 0.98 MA 0.02 ) 0.95 Pb(I 0.5 Br 0.5 ) 3 ), all iodide with a moderately high Cs ratio (FA 0.8 Cs 0.2 PbI 3 ), and FA-dominated triple cation (Cs 0.05 (FA 0.98 MA 0.02 ) 0.95 Pb(I 0.98 Br 0.02 ) 3 ). Cs 0.05 (FA 0.98 MA 0.02 ) 0.95 Pb(I 0.98 Br 0.02 ) 3 displayed the best combined photo-plus-thermal stability. Degradation mechanisms were investigated by comparing the morphology, surface composition, and bulk and interface carrier dynamics. Under the harshest aging conditions (photo-plus-thermal), phase segregation and vaporization of organic cations occurred, along with the appearance of high-energy states indicating the interaction with C 60 . The findings were verified on perovskite films blade-coated in air used in devices (FTO/NiOx/SAM/Perovskite/C 60 /BCP/Cu), achieving an efficiency of 21.9% alongside correlated stability.

14 SOLAR ENERGY↗

Post-irradiation Heating Tests of As-Irradiated AGR-3/4 TRISO Fuel Compacts

Four post-irradiation heating tests of fuel compacts from the U.S. Advanced Gas Reactor (AGR)-3/4 irradiation experiment were completed. In addition to tristructural isotropic (TRISO)-coated driver fuel, each compact contained designed-to-fail (DTF) particles with fuel kernels coated only in pyrocarbon so as to simulate exposed kernels. Tests at 1600/1700°C, 1400°C, and 1200°C were performed to measure fission product release as a function of time and temperature. Silver release was highest in the 1200°C test, supporting the observation that silver release rates are highest in the 1100–1300°C range. Compared to tests of AGR-1 compacts with no exposed kernels, the Cs-134 and Kr-85 releases were noticeably higher in AGR-3/4. The exposed kernels’ contributions to Eu and Sr release are inconclusive, due to the difficulty in distinguishing among the combined effects of higher irradiation temperatures in these particular AGR-3/4 compacts, the presence of the DTF particles, and the Fuel Accident Condition Simulator (FACS) test temperatures. These data can be used to make inferences about fission product retention in exposed kernels as a function of time and temperature.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Direct TPE measurement via $e^+p/e^-p$ scattering at low $\varepsilon$ in Hall A

The proton elastic form factor ratio can be measured either via Rosenbluth separation in an experiment with unpolarized beam and target, or via the use of polarization degrees of freedom. However, data produced by these two approaches show a discrepancy, increasing with $Q^2$. The proposed explanation of this discrepancy - two-photon exchange - has been tested recently by three experiments. The results support the existence of a small two-photon exchange effect but cannot establish that theoretical treatments at the measured momentum transfers are valid. At larger momentum transfers, theory remains untested, and without further data, it is impossible to resolve the discrepancy. Additionally, a positron beam at Jefferson Lab allows us to directly measure two-photon exchange over an extended $Q^2$ and $\epsilon$ range with high precision. With this, we can validate whether the effect reconciles the form factor ratio measurements, and test several theoretical approaches, valid in different parts of the tested $Q^2$ range. In this proposal, we describe a measurement program in Hall A that combines the Super BigBite, BigBite, and High Resolution Spectrometers to directly measure the two-photon effect. Though the limited beam current of the positron beam will restrict the kinematic reach, this measurement will have very small systematic uncertainties, making it a clean probe of two photon exchange.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cosmology From CMB Lensing and Delensed EE Power Spectra Using 2019-2020 SPT-3G Polarization Data

From CMB polarization data alone we reconstruct the CMB lensing power spectrum, comparable in overall constraining power to previous temperature-based reconstructions, and an unlensed E -mode power spectrum, with clear detections of the third through tenth acoustic peaks. The observations, taken in 2019 and 2020 with the South Pole Telescope (SPT) and the SPT-3G camera, cover 1500 deg 2 at 95, 150, and 220 GHz with arcminute resolution and roughly 4.9 µ K-arcmin coadded noise in polarization. The power spectrum estimates, together with systematic parameter estimates and a joint covariance matrix, follow from a Bayesian analysis using the Marginal Unbiased Score Expansion (MUSE) method. The E -mode spectrum at ℓ > 2000 and lensing spectrum at L > 350 are the most precise to date. Assuming the ΛCDM model, and using only these SPT data and priors on τ and absolute calibration from Planck, we find H 0 = 66.81 ± 0.81 km/s/Mpc, comparable in precision to the Planck determination and in 5.4 σ tension with the most precise H 0 inference derived via the distance ladder. We also find S 8 ≡ σ 8 (Ω m /0.3) 0.5 = 0.850 ± 0.017, providing further independent evidence of a slight tension with low-redshift structure probes. The ΛCDM model provides a good simultaneous fit to the combined Planck, ACT, and SPT data, and thus passes a powerful test. Combining these CMB datasets with BAO observations, we explore extensions to the ΛCDM model. We find that the effective number of neutrino species, spatial curvature, and primordial helium fraction are consistent with standard model values, and that the 95% confidence upper limit on the neutrino mass sum is 0.075 eV, close to the minimum sum expected from observations of solar and atmospheric neutrino oscillations. The SPT data are consistent with the somewhat weak (< 3 σ ) preference for excess lensing power seen in Planck and ACT data relative to predictions of the ΛCDM model given the combined Planck, ACT, and BAO data sets. Finally, we also detect at greater than 3 σ the influence of non-linear evolution in the CMB lensing power spectrum and discuss it in the context of the S 8 tension. Forthcoming SPT-3G analyses will feature deeper and wider observations in temperature and polarization, providing even tighter constraints and more powerful tests of the ΛCDM model.

79 ASTRONOMY AND ASTROPHYSICS↗

Smoothing and flattening the universe through slow contraction versus inflation

In a systematic study, we use an equivalent pair of improved numerical relativity codes based on a tetrad-formulation of the classical Einstein-scalar field equations to examine whether slow contraction or inflation (or both) can resolve the homogeneity, isotropy and flatness problems. Our finding, based on a set of gauge/frame invariant diagnostics and the models considered, is that slow contraction robustly and rapidly smooths and flattens spacetime beginning from initial conditions that are outside the perturbative regime of the flat Friedmann-Robertson-Walker metric, whereas inflation fails these tests. We present new numerical evidence supporting the conjecture that the combination of ultralocal evolution and an effective equation-of-state with pressure much greater than energy density is the key to having robust and rapid smoothing. The opposite of ultralocality occurs in expanding spacetimes, which is the leading obstruction to smoothing following a big bang.

79 ASTRONOMY AND ASTROPHYSICS↗

Iodine effective diffusion coefficients through volcanic rock: Influence of iodine speciation and rock geochemistry

Accurate prediction of the subsurface transport of iodine species is important for the assessment of long-term nuclear waste repository performance, as well as monitoring compliance with the Comprehensive Nuclear-Test-Ban Treaty, given that radioiodine decays into radioxenon. However, the transport of iodine through intact geologic media is not well understood, compromising our ability to assess risk associated with radioiodine migration. The current study's goal is to quantify the matrix diffusion of iodine species through saturated volcanic rock, with particular attention paid to the redox environment and potential speciation changes. Here, diffusion experiments were run for iodide through lithophysae-rich lava, lithophysae-poor lava, and welded tuff, whereas iodate diffusion was studied through welded tuff. Iodine transport was compared with a conservative tracer, HDO, and effective diffusion coefficients were calculated. Likely due to a combination of size and anion exclusion effects, iodine species diffused more slowly than the conservative tracer through all rock types tested. Furthermore, oxidation of iodide to iodate was observed in the lithophysae-poor lava, affecting transport. Results provide much needed data for subsurface transport models that predict radioiodine migration from underground sources, and indicate the pressing need for geochemical and redox interactions to be incorporated into these models.

58 GEOSCIENCES↗

A microfluidic system that replicates pharmacokinetic (PK) profiles in vitro improves prediction of in vivo efficacy in preclinical models

Test compounds used on in vitro model systems are conventionally delivered to cell culture wells as fixed concentration bolus doses; however, this poorly replicates the pharmacokinetic (PK) concentration changes seen in vivo and reduces the predictive value of the data. Herein, proof-of-concept experiments were performed using a novel microfluidic device, the Microformulator, which allows in vivo like PK profiles to be applied to cells cultured in microtiter plates and facilitates the investigation of the impact of PK on biological responses. We demonstrate the utility of the device in its ability to reproduce in vivo PK profiles of different oncology compounds over multiweek experiments, both as monotherapy and drug combinations, comparing the effects on tumour cell efficacy in vitro with efficacy seen in in vivo xenograft models. In the first example, an ERK1/2 inhibitor was tested using fixed bolus dosing and Microformulator-replicated PK profiles, in 2 cell lines with different in vivo sensitivities. The Microformulator-replicated PK profiles were able to discriminate between cell line sensitivities, unlike the conventional fixed bolus dosing. In a second study, murine in vivo PK profiles of multiple Poly(ADP-Ribose) Polymerase 1/2 (PARP) and DNA-dependent protein kinase (DNA-PK) inhibitor combinations were replicated in a FaDu cell line resulting in a reduction in cell growth in vitro with similar rank ordering to the in vivo xenograft model. Additional PK/efficacy insight into theoretical changes to drug exposure profiles was gained by using the Microformulator to expose FaDu cells to the DNA-PK inhibitor for different target coverage levels and periods of time. We demonstrate that the Microformulator enables incorporating PK exposures into cellular assays to improve in vitro–in vivo translation understanding for early therapeutic insight.

Singh, Dharaminder (ORCID:0000000346306403)↗

Stable and radioactive carbon isotope partitioning in soils and saturated systems: a reactive transport modeling benchmark study

This benchmark provides the first rigorous test of a three-isotope system [ 12 C, 13 C, and 14 C] subject to the combined effects of radioactive decay and both stable equilibrium and kinetic fractionation. We present a series of problems building in complexity based on the cycling of carbon in both organic and inorganic forms. The key components implement (1) equilibrium fractionation between multiple coexisting carbon species as a function of pH, (2) radioactive decay of radiocarbon with associated mass-dependent speciation demonstrating appropriate correction of the Δ 14 C value in agreement with reporting convention, and (3) kinetic stable isotope fractionation due to the oxidation of organic carbon to inorganic forms as a function of time and space in an open, through-flowing system. Participating RTM codes are CrunchTope, ToughReact, Hytec, and The Geochemist’s Workbench. Across all problem levels, simulation results from all RTMs demonstrate good agreement.

58 GEOSCIENCES↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 degrees C from ~40 degrees C) and a different failure mode were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy).

balance of systems↗