At least 73 records · Page 4

Applications of Solid-State Transformers for Electric Power Grid HEMP/GMD Resilience

A high-altitude electromagnetic pulse (HEMP) or geomagnetic disturbance (GMD) can disrupt power grids by inducing low-frequency common-mode (CM) currents. When these currents flow through grounded transformers, they can bias the magnetic core, driving it into saturation and reducing performance or damaging equipment. This work presents a solid-state transformer (SST) to replace vulnerable assets and improve grid resilience. The paper reviews half-cycle saturation in conventional transformers, then describes an SST architecture that neutralizes and redirects CM currents during HEMP/GMD events. A prototype SST is built and validated, demonstrating stable CM-disturbance operation and protection of nearby transformers. Finally, large-scale simulations show how coordinated SST deployment mitigates CM disturbances and strengthens overall grid resilience.

four-leg inverter↗

Single-element balanced detector giving 65 dB CMRR at 30 MHz

We present a simple design for a single-element balanced detector (BD) that utilizes optical fibers in the sensing and reference channels with path length differences set to detect the differential signal at a desired frequency. With this approach, we easily achieve a common-mode rejection ratio of 65 dB, corresponding to the shot-noise limit of our setup. The CMRR demonstration is made in the MHz frequency range but could be extended to the kHz or GHz range. Using a single detector, the BD achieves stable CMRR over extended periods and does not require careful matching of detectors and amplification electronics. We demonstrate the single-element balanced detector design using the optical Kerr effect induced by a 30 MHz pulsed laser, showing a significant improvement over similar experiments using a commercial balanced detector.

Badilla-Nunez, Kelly [Georgia Institute of Technol↗

Short Circuit Detection and Voltage Sense for High Voltage Ionization Tube Power Supplies

Fermilab's PIP-II upgrade requires new rack-mounted power supplies for Beam Loss Monitor (BLM) ionization tubes compatible with the microTCA 4.1 standard, supporting high-side current measurement for short circuit detection, voltage sense telemetry, and low-side current measurement for beam loss readout. This work presents the design and preliminary schematic of such a supply. A resistive current sensing approach was chosen over inductive, optical, and Hall-effect alternatives for its independence from cable length and component availability. A 500 mΩ inline shunt steps the 2 kV common mode voltage down to roughly 70 V, producing a ~27 μV pulse during a short, which is amplified 500x, compared against a 14-bit DAC threshold, and latched to drive a fault line. Voltage sense steps the 2 kV output down at a 1V/1000V ratio, buffers it with a low bias current amplifier, and digitizes it via a 24-bit ADC over SPI. Onboard power is regulated from 12 V down to isolated 5 V and 3.3 V rails, with capacitive isolation on FPGA communication lines. Lumped parameter models were developed for the ionization tube (0.327 nF, 20 to 200 GΩ dynamic resistance) and the RG-58 coaxial cable to support the design. Component selection is complete and a preliminary schematic has been drawn in Altium Designer, forming the foundation for future prototyping and validation.

Yu, Kellen [Cornell U.]↗

Entropy Analysis of FPGA Interconnect and Switch Matrices for Physical Unclonable Functions

Random variations in microelectronic circuit structures represent the source of entropy for physical unclonable functions (PUFs). In this paper, we investigate delay variations that occur through the routing network and switch matrices of a field-programmable gate array (FPGA). The delay variations are isolated from other components of the programmable logic, e.g., look-up tables (LUTs), flip-flops (FFs), etc., using a feature of Xilinx FPGAs called dynamic partial reconfiguration (DPR). A set of partial designs is created to fix the placement of a time-to-digital converter (TDC) and supporting infrastructure to enable the path delays through the target interconnect and switch matrices to be extracted by subtracting out common-mode delay components. Delay variations are analyzed in the different levels of routing resources available within FPGAs, i.e., local routing and across-chip routing. Data are collected from a set of Xilinx Zynq 7010 devices, and a statistical analysis of within-die variations in delay through a set of the randomly-generated and hand-crafted interconnects is presented.

97 MATHEMATICS AND COMPUTING↗

Methods for Determining Blood Flow Through Intact Vessels of Experimental Animals Under Conditions of Gravitational Stress and in Extraterrestrial Space Capsules

Work during the initial six months of this program has proceeded along three lines: (1) technical development of blood flowmeter instrumentation: (2) surgical considerations related to special problems of chronic implantation of flowmeter probes: (3) study of the relationship between levels of blood flow and organ activity. Principal engineering effort has been focused on the fundamental phenomena operative in the flowmeter probe and on probe design. Two probes have been constructed and a third is nearing completion. A previously unrecognized source of zero drift has been discovered and corrected. has been designed, assembled, tested and successfully employed in work on the several probes. A significant innovation which has been introduced is the use of a transformer coupled input for suppression of unwanted common mode signals. New low noise transistor amplifiers with characteristics suitable for space vehicle packaging are being developed. Linearity of the present apparatus has been found to extend at least into the near turbulent flow region. Attention has been directed to the two vascular beds of physiologic interest that present particular problems with regard to chronic implantation of flowmeter probes, the myocardium and the liver. Surgical techniques have been perfected that will permit myocardial and liver blood flow measurement. Two groups of animals have successfully undergone surgery and await the implantation of probes. Studies of the relationship between organ blood flow and levels of physiologic activity have been initiated. The first organ system studied was the heart, For the first time autoregulatory mechanisms have been demonstrated within the myocardial vascular bed which rapidly and precisely maintain coronary blood flow at a level i n keeping with the magnitude of cardiac work, Following a summary statement of the status of the program, the work performed is described, A financial review of expenditures incurred and a proposal for future funding are appended,

Shaw, R. F.↗

Tiny biomedical amplifier combines high performance, low power drain

Transistorized, portable, high performance amplifier with low power drain facilitates biomedical studies on mobile subjects. This device, which utilizes a differential input to obtain a common-mode rejection, is used for amplifying electrocardiogram and electromyogram signals.

Deboo, G. J.↗

Amplifier improvement circuit

Stable input stage was designed for the use with a integrated circuit operational amplifier to provide improved performance as an instrumentation-type amplifier. The circuit provides high input impedance, stable gain, good common mode rejection, very low drift, and low output impedance.

Sturman, J.↗

Redundant electronic circuit provides fail-safe control

Circuit using dual control amplifiers and dual position demand potentiometers powered from separate sources is used for reliable hydraulic valve controller that prevents closure of valve when control circuits fail, and maintains valve control to close tolerance for more common modes of controller failure.

Archer, J. W.↗

Stable photosensor amplifiers

Minimization of common mode effects in differential amplifier arrangement which processes signals from two high impedance photosensors is achieved by connecting one photosensor in feedback loop of amplifier and using field effect transistors in the input circuit.

Fujimoto, H.↗

Rebalance electronics

Two basic types of strapdown gyroscope rebalance-electronics were analyzed and compared. These two types were a discrete-pulse ternary system and a width-modulated binary system. In the analyses, major emphasis was placed on the logic sections, the H-switches, the precision voltage reference loops, the noise performance, common-mode rejection, and loop compensation. Results of the analyses were used in identifying specific advantages and disadvantages of system details and in making accuracy and resolution comparisons. Sound engineering principles were applied in the development of both systems; however, it was concluded that each system has some disadvantages that are amenable to improvement.

Blalock, T. V.↗

Low cost instrumentation amplifier

Amplifier can be used for many applications requiring high input impedance and common mode rejection, low drift, and gain accuracy on order of one percent. Performance of inexpensive amplifier approaches that of some commercial instrumentation amplifiers in many specifications.

Sturman, J. C.↗

ASTP simulated lightning test report

A simulated lightning test was conducted on the backup spacecraft for the Apollo Soyuz Test Project mission (CSM-119) to determine the susceptibility of the Apollo spacecraft to damage from the indirect effects of lightning. It is demonstrated that induced lightning effects from low-level injected currents can be scaled linearly to those which are obtained in a full threat lightning stroke. Test results indicate that: (1) many of the power and signal critical circuits would fail if subjected to full-threat lightning, (2) pyrotechnic circuits are safe for full-threat lightning, and (3) common-mode voltages exceeded the failure criteria level for all but three of the circuits tested.

Blount, R. L.↗

Inexpensive pulse-train converter measures analog voltage

Converter measures small voltages or currents in presence of very large common-mode voltages (thousands of volts ac or dc). Advantages are low power consumption, transmission via single isolated channel, simplicity, and operation from single-polarity power supply.

Sturman, J. C.↗

Hybrid ECG signal conditioner

Circuit with high common-mode rejection has ability to filter and amplify accepted analog electrocardiogram (ECG) signals of varying amplitude, shape, and polarity. In addition, low power circuit develops standardized pulses that can be counted and averaged by heart/breath rate processor.

Rinard, G. A.↗

Retrofit energy conservation in residential buildings in southern California

The common energy conservation techniques (ECTs) that can be retrofit-installed into residential buildings are surveyed. The quantity of saved energy for heating and cooling attributable to each ECT is evaluated for three common modes of heating: natural gas heating at 60/therm; heating via heat pump at $1.20/therm; and electric resistance heating at $2.40/therm. In every case, a life cycle cost comparison is made between the long term revenue due to energy conservation and a safe and conventional alternative investment that might be available to the prudent homeowner. The comparison between investment in an ECT and the alternative investment is brought into perspective using the life cycle payback period and an economic Figure of Merit (FOM). The FOM allows for relative ranking between candidate ECTs. Because the entire spectrum of winter heating climates in California is surveyed, the decision maker can determine whether or not a considered ECT is recommended in a given climate, and under what conditions an ECT investment becomes attractive.

Turner, R. H.↗

Circuit transients due to negative bias arcs on a high-voltage solar array in low Earth orbit

Arcing to negatively biased, exposed solar cell interconnects on solar arrays placed in plasma environments was established. Arcing, however, may cause damaging interference with the operation of electrical power systems in spacecraft planned to be driven with high-voltage solar arrays. An analytical model was developed to estimate the effects of netagive bias arcs on solar array power system performance. Solar cell characteristics, plasma interactions, and power system features are modeled by a linear, lumped element transient circuit, and the time domain equations are solved. Numerical results for solar array common mode and load voltage transients are calculated for typical conditions. Acceptable load transients are found for a range of arc current amplitudes and time constants.

Metz, R. N.↗

Software fault-tolerance by design diversity DEDIX: A tool for experiments

The use of multiple versions of a computer program, independently designed from a common specification, to reduce the effects of an error is discussed. If these versions are designed by independent programming teams, it is expected that a fault in one version will not have the same behavior as any fault in the other versions. Since the errors in the output of the versions are different and uncorrelated, it is possible to run the versions concurrently, cross-check their results at prespecified points, and mask errors. A DEsign DIversity eXperiments (DEDIX) testbed was implemented to study the influence of common mode errors which can result in a failure of the entire system. The layered design of DEDIX and its decision algorithm are described.

Avizienis, A.↗

Circuit transients due to negative bias arcs-II

Two new models of negative-bias arcing on a solar cell power system in Low Earth Orbit are presented. One is an extended, analytical model and the other is a non-linear, numerical model. The models are based on an earlier analytical model in which the interactions between solar cell interconnects and the space plasma as well as the parameters of the power circuit are approximated linearly. Transient voltages due to arcs struck at the negative thermal of the solar panel are calculated in the time domain. The new models treat, respectively, further linear effects within the solar panel load circuit and non-linear effects associated with the plasma interactions. Results of computer calculations with the models show common-mode voltage transients of the electrically floating solar panel struck by an arc comparable to the early model but load transients that differ substantially from the early model. In particular, load transients of the non-linear model can be more than twice as great as those of the early model and more than twenty times as great as the extended, linear model.

Metz, R. N.↗