At least 73 records · Page 4

Pre-exercise hypervolemia and cycle ergometer endurance in men

Time to exhaustion at 87-91% of peak VO2 was measured in 5 untrained men (age: 31 +/- 8 years, body mass: 74.20 +/- 16.50 kg, body surface area: 1.90 +/- 0.24 m2, peak VO2: 2.87 +/- 0.40 l min-1, plasma volume: 3.21 +/- 0.88 l; means +/-SD) after consuming nothing (N) or two fluid formulations (10 ml kg-1, 743 +/- 161 ml): Performance 1 (P1), a multi-ionic carbohydrate drink, containing 55 mEq l-1 Na+, 4.16 g l-1 citrate, 20.49 g l-1 glucose, and 365 mOsm kg-1 H2O, and AstroAde (AA), a sodium chloride-sodium citrate hyperhydration drink, containing 164 mEq l-1 Na+, 8.54 g l-1 citrate, <5 mg l-1 glucose, and 253 mOsm kg-1 H2O. Mean (+/-SE) endurance for N, P1 and AA was 24.68 +/- 1.50, 24.55 +/- 1.09, and 30.50 +/- 3.44 min respectively. Percent changes in plasma volume (PV) from -105 min of rest to zero min before exercise were -1.5 +/- 3.2% (N), 0.2 +/- 2.2% (P1), and 4.8 +/- 3.0% (AA; P < 0.05). The attenuated endurance for N and P1 could not be attributed to differences in exercise metabolism (VE, RE, VO2) from the carbohydrate or citrate, terminal heart rate, levels of perceived exertion, forehead or thigh skin blood flow velocity, changes or absolute termination levels of rectal temperature. Thus, the higher level of resting PV for AA just before exercise, as well as greater acid buffering and possible increased energy substrate from citrate, may have contributed to the greater endurance.

NASA Center ARC↗

Plasma /Na+/, /Ca++/, and volume shifts and thermoregulation during exercise in man

Graded-exercise experiments are conducted on six trained male runners (19-23 yr) subjected to ergometer exercise in a program consisting of 30-min resting control period, 60 min of rest or exercise at work loads that resulted in a maximal oxygen uptake equivalent to 6% (resting), 23%, 43%, and 62% of maximal oxygen uptake, followed by 30 min of recovery. The parameters measured and discussed are rectal temperature (T-re), skin temperatures at different spots, maximal oxygen uptake, plasma volume (PV), and various plasma electrolyte and protein concentrations. The objectives are to determine whether the increased T-re during progressively greater work loads are related to plasma sodium ion and calcium ion concentrations, as well as to evaluate the influence of PV shifts on the electrolyte and osmotic concentrations. The results suggest that the shift (loss) in PV accounts for the increases in the plasma constituent concentrations that result in significant correlations with T-re.

Greenleaf, J. E.↗

Electrokinetic properties of polymer colloids

The surface of polymer colloids, especially polystyrene latexes, were modified for the purpose of controlling the electrokinetic properties of the resulting colloids. Achievement required a knowledge of electrical double layer charging mechanism, as a function of the electrolyte conditions, at the polymer/water interface. The experimental approach is to control the recipe formulation in the emulsion polymerization process so as to systematically vary the strong acid group concentration on the surface of the polymer particles. The electrophoretic mobility of these model particles will then be measured as a function of surface group concentration and as a function of electrolyte concentration and type. An effort was also made to evaluate the electrophoretic mobility of polystyrene latexes made in space and to compare the results with latexes made on the ground.

Micale, F. J.↗

Solubility of non-polar gases in electrolyte solutions

Solubility theory describes the effects of both concentration and temperature on solute activity coefficients. It predicts the salting-out effect and the decrease in solubility of non-polar gases with increased electrolyte concentration, and can be used to calculate heats of solution, entropies, and partial molal volumes of dissolved gases

Walker, R. L., Jr.↗

KOH concentration effect on cycle life of nickel-hydrogen cells

A cycle life test of Ni/H2 cells containing electrolytes of various KOH concentrations and a sintered type nickel electrode was carried out at 23 C using a 45 min accelerated low Earth orbit (LEO) cycle regime at 80 percent depth of discharge. One of three cells containing 26 percent KOH has achieved over 28,000 cycles, and the other two 19,000 cycles, without a sign of failure. Two other cells containing 31 percent KOH electrolyte, which is the concentration presently used in aerospace cells, failed after 2,979 and 3,620 cycles. This result indicates that the cycle life of the present type of Ni/H2 cells may be extended by a factor of 5 to 10 simply by lowering the KOH concentration. Long cycle life of a Ni/H2 battery at high depth-of-discharge operation is desired, particularly for an LEO spacecraft application. Typically, battery life of about 30,000 cycles is required for a five year mission in an LEO. Such a cycle life with presently available cells can be assured only at a very low depth-of-discharge operation. Results of testing already show that the cycle life of an Ni/H2 cell is tremendously improved by simply using an electrolyte of low KOH concentration.

Lim, Hong S.↗

KOH concentration effect on cycle life of nickel-hydrogen cells. III - Cycle life test

A cycle life test of Ni/H2 cells containing electrolytes of various KOH concentrations and a sintered type nickel electrode was carried out at 23 C using a 45 min accelerated low earth orbit (LEO) cycle regime at 80 percent depth of discharge. One of three cells containing 26 percent KOH has achieved over 28,000 cycles, and the other two 19,000 cycles, without a sign of failure. Two other cells containing 31 percent KOH electrolyte, which is the concentration presently used in aerospace cells, failed after 2,979 and 3,620 cycles. This result indicates that the cycle life of the present type of Ni/H2 cells may be extended by a factor of 5 to 10 simply by lowering the KOH concentration. Long cycle life of a Ni/H2 battery at high depth-of-discharge operation is desired, particularly for an LEO spacecraft application. Typically, battery life of about 30,000 cycles is required for a five year mission in an LEO. Such a cycle life with presently available cells can be assured only at a very low depth-of-discharge operation. Results of testing already show that the cycle life of an Ni/H2 cell is tremendously improved by simply using an electrolyte of low KOH concentration.

Lim, H. S.↗

Effect of silicate ions on electrode overvoltage

The influence of the addition of a silicate to a caustic solution (KOH) is studied in order to determine the degree to which silicates inhibit the corrosion of chrysotile under conditions of electrolysis at working temperatures of 100 C and above. In an alkaline solution containing various silicate concentrations, current density was increased and electrode overvoltage was measured. Results show that silicate ion concentrations in the electrolyte increase with temperature without effecting electrochemical performance up to 115 C at 700 MA/sqcm. At this point the concentration is about 0.5 g Si/100 g KOH. Beyond this limit, electrolytic performance rapidly degenerates due to severe oxidation of the electrodes.

Gras, J. M.↗

Bed-rest studies: Fluid and electrolyte responses

Confinement in the horizontal position for 2 to 3 weeks results in a chronic decrease in plasma volume, increased interstitial fluid volume, and unchanged or slightly increased extracellular fluid volume. Concentrations of blood electrolytes, glucose, and nitrogenous constituents remain within normal limits of variability when maintenance levels of isometric or isotonic exercise are performed for 1 hr/day. Hematocrit and plasma osmolality can be elevated significantly throughout bed rest (BR). Significant diuresis occurs on the first day, and increases in urine Na and Ca continue throughout BR, although voluntary fluid intake is unchanged. Urine Na and K are evaluated during the second week of BR in spite of stabilization of PV and extracellular volume. The initial diuresis probably arises from the extracellular fluid while subsequent urine loss above control levels must come from the intracellular fluid. Preservation of the extracellular volume takes precedance over maintenance of the intracellular fluid volume. The functioning of a natriuretic factor (hormone) to account for the continued increased loss of Na in the urine is suggested.

Greenleaf, J. E.↗

Bed-rest studies - Fluid and electrolyte responses

Confinement in the horizontal position for 2 to 3 weeks results in a chronic decrease in plasma volume, increased interstitial fluid volume, and unchanged or slightly increased extracellular fluid volume. Concentrations of blood electrolytes, glucose, and nitrogenous constituents remain within normal limits of variability when maintenance levels of isometric or isotonic exercise are performed for 1 hr/day. Hematocrit and plasma osmolality can be elevated significantly throughout bed rest (BR). Significant diuresis occurs on the first day, and increases in urine Na and Ca continue throughout BR, although voluntary fluid intake is unchanged. Urine Na and K are evaluated during the second week of BR in spite of stabilization of PV and extracellular volume. The initial diuresis probably arises from extracellular fluid while subsequent urine loss above control levels must come from the intracellular fluid. Preservation of the extracellular volume takes precedance over maintenance of the intracellular fluid volume. The functioning of a natriuretic factor (hormone) to account for the continued increased loss of Na in the urine is suggested. Previously announced in STAR as N83-24160

Greenleaf, J. E.↗

Electrolyte cells measure oxygen fugacities

System that uses calcia-stabilized zirconia-ceramic electrolyte in oxygen concentration cell can directly measure oxygen fugacity in vertical-quench furnace, redox-control system. System can independently vary temperature and oxygen fugacity during experiments, and can record these parameters as function of time.

Williams, R. J.↗

Electrocatalysis of fuel cell reactions: Investigation of alternate electrolytes

Oxygen reduction and transport properties of the electrolyte in the phosphoric acid fuel cell are studied. A theoretical expression for the rotating ring-disk electrode technique; the intermediate reaction rate constants for oxygen reduction on platinum in phosphoric acid electrolyte; oxygen reduction mechanism in trifluoromethanesulfonic acid (TFMSA), considered as an alternate electrolyte for the acid fuel cells; and transport properties of the phosphoric acid electrolyte at high concentrations and temperatures are covered.

Chin, D. T.↗

Electrocatalysis of fuel cell reactions: Investigation of alternate electrolytes

Oxygen reduction and transport properties of the electrolyte in the phosphoric acid fuel cell are studied. The areas covered were: (1) development of a theoretical expression for the rotating ring disk electrode technique; (2) determination of the intermediate reaction rate constants for oxygen reduction on platinum in phosphoric acid electrolyte; (3) determination of oxygen reduction mechanism in trifluoreomethanesulfonic acid (TFMSA) which was considered as an alternate electrolyte for the acid fuel cells; and (4) the measurement of transport properties of the phosphoric acid electrolyte at high concentrations and temperatures.

Chin, D. T.↗

Mathematical modeling of a thermovoltaic cell

A new type of battery named 'Vaporvolt' cell is in the early stage of its development. A mathematical model of a CuO/Cu 'Vaporvolt' cell is presented that can be used to predict the potential and the transport behavior of the cell during discharge. A sensitivity analysis of the various transport and electrokinetic parameters indicates which parameters have the most influence on the predicted energy and power density of the 'Vaporvolt' cell. This information can be used to decide which parameters should be optimized or determined more accurately through further modeling or experimental studies. The optimal thicknesses of electrodes and separator, the concentration of the electrolyte, and the current density are determined by maximizing the power density. These parameter sensitivities and optimal design parameter values will help in the development of a better CuO/Cu 'Vaporvolt' cell.

White, Ralph E.↗

A mathematical model of a CuO/Cu Vaporvolt cell

A new type of battery named 'Vaporvolt' cell is in the early stage of its development. A mathematical model of a CuO/Cu 'Vaporvolt' cell is presented that can be used to predict the potential and the transport behavior of the cell during discharge. A sensitivity analysis of the various transport and electrokinetic parameters indicates which parameters have the most influence on the predicted energy and power density of the 'Vaporvolt' cell. This information can be used to decide which parameters should be optimized or determined more accurately through further modeling or experimental studies. The optimal thicknesses of electrodes and separator, the concentration of the electrolyte, and the current density are determined by maximizing the power density. These parameter sensitivities and optimal design parameter values will help in the development of a better CuO/Cu 'Vaporvolt' cell.

Kawanami, Makoto↗

CD4(+)/CD8(+) T-lymphocyte Ratio: Effects of Rehydration before Exercise in Dehydrated Men

Effects of fluid ingestion on CD4+/CD8+ T-lymphocyte cell ratios were measured in four dehydrated men (ages 30-46 yr) before and after 70 min of supine submaximal (71 % VO(sub 2max) lower extremity cycle exercise. Just before exercise, Evans blue dye was injected for measurement of plasma volume. The subjects then drank one of six fluid formulations (12 ml/kg) in 3-4 min. All six mean post-hydration (pre-exercise) CD4+/CD8+ ratios (Becton-Dickinson Fluorescence Activated Cell Sorter and FACScan Consort-30 software program were below the normal range of 1.2-1.5; mean (+/- SE) and range were 0.77 +/- 0.12 and 0.39-1.15, respectively. The post-exercise ratios increased: mean = 1.36 =/- 0.15 (P less than 0.05) and range = 0.98-1.98. Regression of mean CD4+/CD8+ ratios on mean plasma osmolality resulted in pre- and post-exercise correlation coefficients of -0.76 (P less than 0.10) and -0.92 (P less than 0.01), respectively. The decreased pre-exercise ratios (after drinking) were probably not caused by the Evans blue dye but appeared to be associated more with the stress (osmotic) of dehydration. The increased post-exercise ratios to normal levels accompanied the rehydration and were not due to the varied electrolyte and osmotic concentrations of the ingested fluids or to the varied vascular volume shifts during exercise. Thus, the level of subject hydration and plasma osmotality may be factors involved in the mechanism of immune system modulation induced by exercise.

Greenleaf, John E.↗

Process for producing nickel electrode having lightweight substrate

A nickel electrode having a lightweight porous nickel substrate is subjected to a formation cycle involving heavy overcharging and under-discharging in a KOH electrolyte having a concentration of 26% to 31%, resulting in electrodes displaying high active material utilization.

Lim, Hong S.↗

Electrochemical Detection of the Molecules of Life

All forms of life on Earth contain cellular machinery that can transform and regulate chemical energy through metabolic pathways. These processes are oxidation-reduction reactions that are performed by four key classes of molecules: flavins, nicotinamaides, porphyrins, and quinones. By detecting the electrochemical interaction of these redox-active molecules with an electrode, a method of differentiating them by their class could be established and incorporated into future life-detecting missions. This body of work investigates the electrochemistry of ubiquitous molecules found in life and how they may be detected. Molecules can oxidise or reduce the surface of an electrode - giving or receiving electrons - and these interactions are represented by changes in current with respect to an applied voltage. This relationship varies with: electrolyte type and concentration, working electrode material, the redox-active molecule itself, and scan rate. Flavin adenine dinucleotide (FAD), riboflavin, nicotinamide adenine dinucleotide (NADH), and anthraquinone are all molecules found intracellularly in almost all living organisms. An organism-synthesised extracellular redox-active molecule, Plumbagin, was also selected as part of this study. The goal of this work is to detect these molecules in seawater and assess its application in searching for life on Ocean Worlds.

astrobiolog↗