Search NASA⌕ Search

SEARCH · Search NASA

Results for “Configuration Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Prime Time for Model-Predictive Control? Assessing the Technical and Market Readiness of Advanced Controls in Buildings

Despite three decades of extensive research and field testing that have consistently validated the benefits of Model Predictive Control (MPC) in building applications, the technology has seen limited market adoption. This paper evaluates the readiness of MPC for widespread deployment, showcases recent demonstrations and field tests across diverse building types, including residential, small commercial, large commercial, and campus settings. Our results demonstrate that MPC can optimize system operations to achieve load shifting, minimize curtailment of on-site generation, and reduce energy costs by up to 80 %, while maintaining or improving occupant comfort. We also show that MPC can effectively control large assets, such as MW-sized thermal storage systems, and respond to dynamic pricing signals. However, achieving scale remains difficult due to labor-intensive workflows, reliance on a “PhD-in-the-loop” for MPC design and maintenance, susceptibility to fragile data infrastructure, and persistent workforce education and acceptance barriers. To bridge this gap, we outline a transition from bespoke, labor intensive prototypes toward streamlined, segment-targeted deployment strategies that leverage model templates, semantic tools, and generative AI. By automating control configuration and reducing engineering effort, these recommendations provide a pathway for transforming successful research demonstrations into scalable, market ready solutions for MPC-based controls.

Pritoni, Marco↗

An Investigation of Heuristic Control Strategies for Multi-Electrolyzer Wind-Hydrogen Systems Considering Degradation

With the growing demand for renewable-energy-powered hydrogen generation and the corresponding increase in plant capacity, individually controlling many electrolyzer stacks will be critical for increasing the plant's lifetime and efficiency. This paper introduces a rule-based controller framework targeting electrolyzer degradation to explore the opportunity space in multi-stack hydrogen plant control. A novel control-oriented degradation model is also presented in this work, which quantifies the impact of steady power input, fluctuating power input, and the number of startup/shutdown cycles on electrolyzer degradation. Using a wind power input signal, 13 controller configurations are tested on 5 MW hydrogen plants consisting of 2, 5, 10, and 25 stacks. These configurations are evaluated on their capability to mitigate electrolyzer degradation and efficiently produce hydrogen from the time-varying input power. The results show that multi-stack control for degradation can extend the plant's lifetime by more than a factor of 3 with minimal impact on instantaneous hydrogen production.

control↗

NMR logging apparatus

Technologies including NMR logging apparatus and methods are disclosed. Example NMR logging apparatus may include surface instrumentation and one or more downhole probes configured to fit within an earth borehole. The surface instrumentation may comprise a power amplifier, which may be coupled to the downhole probes via one or more transmission lines, and a controller configured to cause the power amplifier to generate a NMR activating pulse or sequence of pulses. Impedance matching means may be configured to match an output impedance of the power amplifier through a transmission line to a load impedance of a downhole probe. Methods may include deploying the various elements of disclosed NMR logging apparatus and using the apparatus to perform NMR measurements.

47 OTHER INSTRUMENTATION↗

NMR logging apparatus

Technologies including NMR logging apparatus and methods are disclosed. Example NMR logging apparatus may include surface instrumentation and one or more downhole probes configured to fit within an earth borehole. The surface instrumentation may comprise a power amplifier, which may be coupled to the downhole probes via one or more transmission lines, and a controller configured to cause the power amplifier to generate a NMR activating pulse or sequence of pulses. Impedance matching means may be configured to match an output impedance of the power amplifier through a transmission line to a load impedance of a downhole probe. Methods may include deploying the various elements of disclosed NMR logging apparatus and using the apparatus to perform NMR measurements.

47 OTHER INSTRUMENTATION↗

Investigations on the heat flux and impurity for the HL-2M divertor

The controllability of the heat load and impurity in the divertor is very important, which could be one of the critical problems to be solved in order to ensure the success for a steady state tokamak. HL-2M has the advantage of the poloidal field (PF) coils placed inside the demountable toroidal field (TF) coils and close to the main plasma. As a result, it is possible to make highly accurate configuration control of the advanced divertor for HL-2M. The divertor target geometry of HL-2M has been designed to be compatible with different divertor configurations to study the divertor physics and support the high performance plasma operations. In this paper, the heat loads and impurities with different divertor configurations, including the standard X-point divertor, the snowflake-minus divertor and two tripod divertor configurations for HL-2M, are investigated by numerical simulations with the SOLPS5.0 code under the current design of the HL-2M divertor geometry. The plasmas with different conditions, such as the low discharge parameters with ${{I}_{\text{p}}}$ = 0.5 MA at the first stage of HL-2M and the high parameters with ${{I}_{\text{p}}}$ = 2.0 MA during the normal operations, are simulated. The heat load profiles and the impurity distributions are obtained, and the control of the peak heat load and the effect of impurity on the core plasma are discussed. The compatibility of different divertor configurations for HL-2M is also evaluated. It is seen that the excellent compatibility of different divertor configurations with the current divertor geometry has been verified. Here, the results show that the snowflake-minus divertor and the tripod divertor with ${{d}_{x}}=30\,\text{cm}$ present good performance in terms of the heat load profiles and the impurity distributions under different conditions, which may not have a big effect on the core plasma. In addition, it is possible to optimize the distance between the two X-points, ${{d}_{x}}$ , to achieve a better performance in terms of the parameters of discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary Requirements for NSLS-II Beam Containment Systems

Beam containment system (BCS) is the term used to describe the various active and passive devices designed to prevent excessive radiation levels in occupied areas by limiting beam energy and beam losses. BCS components provide protection function by controlling machine operation through the NSLS-II personnel protective system (PPS) and through local and remote alarms. All equipment designated as a component of the BCS beam containment system will be subject to formal configuration control and, depending on the magnitude of the resulting radiation fields, may require redundant sensors and electronic channels.

36 MATERIALS SCIENCE↗

VERA Infrastructure

The Virtual Environment for Reactor Applications (VERA) Infrastructure provides the infrastructure to build, configure, test, install, and package for release the VERAS suite of codes that is being developed by the Consortium for the Advanced Simulation of Light-water reactors (CASL). It includes the list of codes that can be built within VERA, the location on the configuration-controlled CASL development computer, the version number used in any particular software installation, the location of the third-party libraries used for testing VERA on a suite of the CASL testing and development computers, and the scripts to configure, build, test, install, and package for release a particular version of VERA. The VERA Infrastructure contains a list of scripts, configuration options, and utilities that are specific to CASL, but contain no physics or numeric, nuclear technology, or encryption technology.

Baird, Mark↗

Towards accurate prediction of configurational disorder properties in materials using graph neural networks

Abstract The prediction of configurational disorder properties, such as configurational entropy and order-disorder phase transition temperature, of compound materials relies on efficient and accurate evaluations of configurational energies. Previous cluster expansion methods are not applicable to configurationally-complex material systems, including those with atomic distortions and long-range orders. In this work, we propose to leverage the versatile expressive capabilities of graph neural networks (GNNs) for efficient evaluations of configurational energies and present a workflow combining attention-based GNNs and Monte Carlo simulations to calculate the disorder properties. Using the dataset of face-centered tetragonal gold copper without and with local atomic distortions as an example, we demonstrate that the proposed data-driven framework enables the prediction of phase transition temperatures close to experimental values. We also elucidate that the variance of the energy deviations among configurations controls the prediction accuracy of disorder properties and can be used as the target loss function when training and selecting the GNN models. The work serves as a fundamental step toward a data-driven paradigm for the accelerated design of configurationally-complex functional material systems.

Chemistry↗

DC compensation for power transformer through neutral DC injection

A power transmission system can include a transformer and compensator circuit(s), each coupled between a node of the transformer and a ground connection. The compensator circuit(s) can each be configured to counteract a DC signal component of an AC signal at the transformer. The compensator circuit(s) can include a converter circuit having an AC side and a DC side and configured to convert a DC voltage on the DC side to an AC signal at the AC side. The compensator circuit(s) can include a DC link coupled to the DC side of the converter circuit. The compensator circuit(s) can include a controller configured to measure a DC signal component between the load and the ground; to determine, based at least in part on the DC signal component, a compensating signal configured to counteract the DC signal component; and to inject, by the converter circuit, the compensating signal to counteract the DC signal component.

Burkes, Klaehn W.↗

Angular selective window systems: Assessment of technical potential for energy savings

Static angular selective shading systems block direct sunlight and admit daylight within a specific range of incident solar angles. The objective of this study is to quantify their potential to reduce energy use and peak demand in commercial buildings using state-of-the art whole-building computer simulation software that allows accurate modeling of the behavior of optically-complex fenestration systems such as angular selective systems. Three commercial systems were evaluated: a micro-perforated screen, a tubular shading structure, and an expanded metal mesh. This evaluation was performed through computer simulation for multiple climates (Chicago, Illinois and Houston, Texas), window-to-wall ratios (0.15-0.60), building codes (ASHRAE 90.1-2004 and 2010) and lighting control configurations (with and without). The modeling of the optical complexity of the systems took advantage of the development of state-of-the-art versions of the EnergyPlus, Radiance and Window simulation tools. Results show significant reductions in perimeter zone energy use; the best system reached 28% and 47% savings, respectively without and with daylighting controls (ASHRAE 90.1-2004, south facade, Chicago,WWR=0.45). As a result, angular selectivity and thermal conductance of the angle-selective layer, as well as spectral selectivity of low-emissivity coatings, were identified as factors with significant impact on performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The application of ICASPA to critical and safe mass calculations - 14586

ICASPA, an Improved Critical and Safe Parameters Algorithm, calculates the size of a fissile body for a given value of k-effective. ICASPA uses an iterative predictor/corrector algorithm in which the MONK9A code is used to derive a precise k-effective value for a given candidate body size; auxiliary equations are then used to adjust the body size. The process is repeated until MONK9A outputs the chosen target value of k-effective. EDF Energy operates eight nuclear power stations comprising one Pressurized Water Reactor (PWR) and seven Advanced Gas-cooled Reactor (AGR) stations. At these sites, the term 'fuel route' is used to encompass all of the ex-reactor arrangements for the handling and storage of fuel. The criticality safety cases for these fuel routes are based on the use of geometrically safe arrangements for the required quantities of fuel. The allowed quantities and arrangements of fuel are safely sub-critical, even under the contingency of accidental moderator ingress. The fuel route safety cases consider all credible potential fault conditions, including events such as dropped fuel. Any such events might change the geometry of the fuel elements, but it is difficult to calculate exact k-effective values for realistic models of dropped fuel. This difficulty is overcome by the use of an alternative approach in which limiting safe masses are calculated for bounding (worst-case) rearrangements of fuel rods and moderators, using geometries similar to those covered by criticality handbook data. Where required, the resulting safe masses are used to set safety case limits and conditions. For example, some fire extinguishants, such as water and ABC dry powder, are also effective moderators. Hence, in some fuel route areas, administrative criticality controls are used to either prohibit or limit the permitted quantities of these materials. This paper describes the work that has been carried out to adopt ICASPA as the approved calculation method for these safe mass calculations. The work has been carried out within the company quality assurance requirements for nuclear safety related software. It has involved the development of a configuration controlled version of ICASPA and the local verification and validation of the resulting code. The benefits from the adoption of ICASPA are also presented. These include accuracy improvements and, because the method uses the MONK9A code for k-effective calculations, the ability to use more sophisticated models for limiting case geometries. (authors)

42 ENGINEERING↗

Nominal and adversarial synthetic PMU data for standard IEEE test systems

GridSTAGE (Spatio-Temporal Adversarial scenario GEneration) is a framework for the simulation of adversarial scenarios and the generation of multivariate spatio-temporal data in cyber-physical systems. GridSTAGE is developed based on Matlab and leverages Power System Toolbox (PST) where the evolution of the power network is governed by nonlinear differential equations. Using GridSTAGE, one can create several event scenarios that correspond to several operating states of the power network by enabling or disabling any of the following: faults, AGC control, PSS control, exciter control, load changes, generation changes, and different types of cyber-attacks. Standard IEEE bus system data is used to define the power system environment. GridSTAGE emulates the data from PMU and SCADA sensors. The rate of frequency and location of the sensors can be adjusted as well. Detailed instructions on generating data scenarios with different system topologies, attack characteristics, load characteristics, sensor configuration, control parameters are available in the Github repository - https://github.com/pnnl/GridSTAGE. There is no existing adversarial data-generation framework that can incorporate several attack characteristics and yield adversarial PMU data. The GridSTAGE framework currently supports simulation of False Data Injection attacks (such as a ramp, step, random, trapezoidal, multiplicative, replay, freezing) and Denial of Service attacks (such as time-delay, packet-loss) on PMU data. Furthermore, it supports generating spatio-temporal time-series data corresponding to several random load changes across the network or corresponding to several generation changes. A Koopman mode decomposition (KMD) based algorithm to detect and identify the false data attacks in real-time is proposed in https://ieeexplore.ieee.org/document/9303022. Machine learning-based predictive models are developed to capture the dynamics of the underlying power system with a high level of accuracy under various operating conditions for IEEE 68 bus system. The corresponding machine learning models are available at https://github.com/pnnl/grid_prediction.

99 GENERAL AND MISCELLANEOUS↗

Systems and methods for regulating pressure of a filled-in gas

A system for regulating a pressure of a filled-in gas is presented. The system includes a reservoir that stores a reservoir gas adsorbed in a sorbent material at a storage temperature, a gas-filled tube containing the filled-in gas, a controller configured to determine a pressure change required in the filled-in gas based upon signals representative of a pressure of the filled-in gas inside the gas-filled tube and a required pressure threshold, determine an updated temperature of the sorbent material based upon the pressure change required in the filled-in gas, and regulate the pressure of the filled-in gas by controlling the reservoir to change the storage temperature of the sorbent material to reach the updated temperature of the sorbent material.

36 MATERIALS SCIENCE↗

Electric control of magnetization relaxation in thin film magnetic insulators.

Control of magnetization relaxation in magnetic insulators via interfacial spin scattering is demonstrated. The experiments use nanometer-thick yttrium iron garnet (YIG)/Pt layered structures, with the Pt layer biased by an electric voltage. The bias voltage produces a spin current across the Pt thickness. As this current scatters off the YIG surface, it exerts a torque on the YIG surface spins. This torque can reduce or enhance the damping and thereby decrease or increase the ferromagnetic resonance linewidth of the YIG film, depending on the field/current configuration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transient studies of an Integrated Gasification Combined Cycle (IGCC) plant with CO2 capture

Next-generation coal-fired power plants need to consider the option for CO2 capture as stringent governmental mandates are expected to be issued in near future. Integrated gasification combined cycle (IGCC) plants are more efficient than the conventional coal combustion processes when the option for CO2 capture is considered. However, no IGCC plant with CO2 capture currently exists in the world. Therefore, it is important to consider the operability and controllability issues of such a plant before it is commercially built. To facilitate this objective, a detailed plant-wide dynamic simulation of an IGCC plant with 90% CO2 capture has been developed in Aspen Plus Dynamics{reg_sign}. The plant considers a General Electric Energy (GEE)-type downflow radiant-only gasifier followed by a quench section. A two-stage water gas shift (WGS) reaction is considered for conversion of CO to CO2. A two-stage acid gas removal (AGR) process based on a physical solvent is simulated for selective capture of H2S and CO2. Compression of the captured CO2 for sequestration, an oxy-Claus process for removal of H2S and NH3, black water treatment, and the sour water treatment are also modeled. The tail gas from the Claus unit is recycled to the SELEXOL unit. The clean syngas from the AGR process is sent to a gas turbine followed by a heat recovery steam generator. This turbine is modeled as per published data in the literature. Diluent N2 is used from the elevated-pressure ASU for reducing the NOx formation. The heat recovery steam generator (HRSG) is modeled by considering generation of high-pressure, intermediate-pressure, and low-pressure steam. All of the vessels, reactors, heat exchangers, and the columns have been sized. The basic IGCC process control structure has been synthesized by standard guidelines and existing practices. The steady state results are validated with data from a commercial gasifier. In the future grid-connected system, the plant should satisfy the environmental targets and quality of the feed to other sections, wherever applicable, without violating the operating constraints, and without sacrificing the efficiency. However, it was found that the emission of acid gases may far exceed the environmental targets and the overshoot of some of the key variables may be unacceptable under transient operation while following the load. A number of operational strategies and control configurations is explored for achieving these stringent requirements. The transient response of the plant is also studied by perturbing a number of key inputs.

97 MATHEMATICS AND COMPUTING↗

Systems and methods for advanced grid integration of distributed generators and energy resources

A circuit for a smart photovoltaic (PV) inverter system and the smart PV inverter system are described. The circuit includes one or more strings coupled to an electrical load. Each of the one or more strings further includes one or more string members coupled in series, where each of the one or more string members comprises a voltage source and an inverter. The circuit also includes a controller to receive an output from an operator controller and control the strings, where the controller is configured to control the strings by providing a function command to a first string member of each of the one or more strings based on the output from the operator controller. The voltage source may also receive an output from an energy output device. Further, the inverter may be configured to convert the output of energy output device into an energy source of electrical load.

Bhowmik, Shibashis↗

Model Package Report: Central Plateau Vadose Zone Models

This model package report describes concisely the modeling objectives, conceptualization, implementation, uncertainty and sensitivity, configuration control, limitations, data needs, and recommendations for improvement of the Central Plateau Vadose Zone Models. This collection of models is developed to meet the vadose zone simulation needs of the Hanford Site Composite Analysis (CA), the Hanford Site Cumulative Impact Evaluation (CIE), and are expected to find other applications in Hanford Site remedial cleanup decision-making processes. This model package report describes and documents the development of the models themselves to fulfill technical approaches defined for the CA and the CIE. This report does not document any specific calculation using these models: instead, applications of individual vadose models to perform specific calculations will be documented in environmental calculation files, including inputs and results, as appropriate. Configuration management for the Central Plateau Vadose Zone Models is managed through assignment of unique sequential numerical version numbers and archival of the models in the Environmental Modeling Management Archive.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NIF Ignition Target 3D Point Design

We have developed an input file for running 3D NIF hohlraums that is optimized such that it can be run in 1-2 days on parallel computers. We have incorporated increasing levels of automation into the 3D input file: (1) Configuration controlled input files; (2) Common file for 2D and 3D, different types of capsules (symcap, etc.); and (3) Can obtain target dimensions, laser pulse, and diagnostics settings automatically from NIF Campaign Management Tool. Using 3D Hydra calculations to investigate different problems: (1) Intrinsic 3D asymmetry; (2) Tolerance to nonideal 3D effects (e.g. laser power balance, pointing errors); and (3) Synthetic diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗