Search NASA⌕ Search

SEARCH · Search NASA

Results for “Construction & building technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Effects of multiple simultaneous faults on characteristic fault detection features of a heat pump in cooling mode

Faults in air-cooled vapor compression air-conditioning systems are known to reduce performance, including efficiency, capacity, and lifespan. Their effects have been studied, and fault detection and diagnostic (FDD) methods have been developed as tools for field technicians to install or repair systems, or for monitoring to alert operators to the fault’s presence. Most of this work has focused on faults that occur singly. It is likely that in some systems, multiple faults occur simultaneously, but it is uncertain what effects this may have on diagnostics. Here, this paper describes a laboratory study of a split system air source heat pump in which combinations of two, three, and four simultaneous faults occur. The study includes all combinations of: improper evaporator airflow; overcharge or undercharge of refrigerant; liquid line restrictions; and non-condensable gas in the refrigerant, each at multiple fault intensities. Fault features – those characteristics that can be determined from measurements, for use in diagnostics – are analyzed, and the key fault features are presented. A robust existing method for determining refrigerant charge, the virtual refrigerant charge sensor (VRC) is tested using the multiple fault data, in order to understand how its performance is impacted by the combined faults. The VRC performs well, typically able to correctly determine whether a system is undercharged or overcharged, but the magnitude estimates are impacted. The results suggest that simple subcooling-based methods of charging a system are likely to provide unsatisfactory results when other faults are present.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A zone-level occupancy counting system for commercial office spaces using low-resolution time-of-flight sensors

Understanding the locations of occupants in a commercial built environment is critical for realizing energy savings by delivering lighting, heating, and cooling only where it is needed. In this paper, we present an indoor occupancy counting system using a sparse array of inexpensive, low-resolution, and privacy-preserving time-of-flight sensors. We develop and validate an algorithm for zonal occupancy counting that can deal with multiple people walking underneath the sensors in arbitrary directions, and evaluate the system both in realistic simulations of office spaces and in a real-world installation. Finally, we found that our system has an error rate of around 0.4%, resulting in highly accurate person localization and zone counting using only a few sensors per space.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of common faults on an air conditioner with a microtube condenser and analysis of fault characteristic features

Split system air conditioners are widely used to cool residential buildings, because of their low cost and simplicity. However, their efficiency is impacted by installation faults, which include: improper refrigerant charge (undercharge or overcharge), improper evaporator airflow, liquid line restrictions (LL), and the presence of non-condensable gas (NC) in the refrigerant. No known previously published research has studied the effect of these four faults on a system equipped with a microtube condenser, which has smaller tube size than a traditional condenser and therefore holds less refrigerant charge, but has a different configuration than a microchannel. Furthermore, very few have studied the impacts of LL and NC. Herein this paper describes laboratory fault tests of a microtube-equipped system, compares the fault impacts with those of a traditional system, and considers the characteristic fault features. The tested system uses R-410A refrigerant and has a scroll compressor, a fixed orifice expansion device, and two fin-tube heat exchangers. The tests were carried out under steady operation with a range of fault intensities and operating conditions. The microtube system’s performance degradation from faults is similar to systems with traditional heat exchangers, despite the reduced capacity to hold refrigerant charge.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building envelope anomaly characterization and simulation using drone time-lapse thermography

Defects in building envelopes deteriorate over time without being visible to the human eye, while significantly impacting energy performance due to unaccounted heat transfer. Defects can be characterized in the infrared (IR) spectrum. However, IR readings are typically recorded at singular points in time, when in several cases anomalies can only be revealed at specific times of the day, possibly in different seasons of the year. This paper presents a novel workflow for 3D envelope defect characterization and modeling using aerial time-lapse IR data collection using drones. A comprehensive envelope thermal profile is developed for a case study building employing the photogrammetry software Agisoft Photoscan, which generates temporal IR inspections of building skins using multiple thermography orthomosaics. Point-cloud data is then translated into a CAD model and thermal zones for whole Building Energy Modeling (BEM) using Honeybee as a frontend to EnergyPlus to showcase the potential of inclusion of detailed 4D data. Envelope contributions in this case study’s anomalies showed heat losses of 6447.6 kWh, and Energy Use Intensity (EUI) differences of ~2 kWh/m 2 /year from the baseline. Finally, why there is currently little translation of this work in BEM software is discussed, while identifying limitations and future research in the employment of time-lapse thermography using drones for more accurate building envelope inspection and modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Incorporating two-dimensional conduction modeling techniques into an energy simulation program: The EnergyPlus radiant system example

Due to the inherent complexity of multi-dimensional solutions for transient conduction in a multilayered building element, most heat balance-based algorithms assume that conduction occurs only in one dimension—through the building element between the inside and outside environments. Usually, since the length and width of the elements are much greater than the thickness of the element, this is a valid assumption. However, there are some cases such as hydronic radiant slabs where this assumption may not lead to an accurate estimate of the energy consumption of the system. In a hydronic radiant slab, water tubes are embedded in a slab, and hot or chilled water is circulated to meet any heating or cooling loads. The energy consumption of such a system will depend highly on the temperature of the water being sent to the slab (i.e., produced by the boiler or chiller). The temperature of the water that must be sent to the slab will depend on the spacing of the tubes, the multilayer construction of the building element, and the boundary conditions to which the construction is exposed. Thus, to accurately predict the energy consumption of such a system, a transient two-dimensional heat conduction model must be integrated with a heat balance-based simulation. This paper demonstrates the potential loss of accuracy associated with the one-dimensional radiant system models by providing a comparison of one- and two-dimensional solutions using EnergyPlus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Biaxial steel plated concrete constitutive models for composite structures: Implementation and validation

The Steel-plated Concrete (SC) technique is an alternative construction technique with faster onsite construction speed, reduced construction time, and increased structural performance. Aiming to predict the force transfer mechanism of SC elements, an innovative constitutive model package is proposed by implementing experimental-based biaxial steel plate concrete models into the nonlinear finite element (FE) model “Membrane Model of SC (MM-CS).” First, the formulation and implementation of the MM-SC is illustrated in detail, including the equilibrium and compatibility equations and the implementation of constitutive models. Next, various experimental data of SC members are selected and simulated using the proposed MM-SC model. In this research, two types of structures, SC panels and framed SC shear walls, and three types of loading conditions, including uniaxial compression, pure shear, and combined axial-flexural-shear tests, are analyzed respectively. Good agreements were obtained between the reported results and the FE simulation results in terms of yield capacity and ultimate capacity, proving the reliability of the implemented analytical constitutive material models and the biaxial membrane model formulations.

42 ENGINEERING↗

Formulation and calibration of two-dimensional constitutive models for composite structures based on panel tests

Steel Plate Concrete (SC) composite members have been widely adopted because of its cost-efficiency and enhanced structural behavior. While researchers have attempted to study its in-plane shear behavior in the past twenty years, very limited number of large-scale pure shear tests were performed due to the challenge of experimental set-up and the availability of facilities. In this paper, a series of uniaxial loading tests and two full-scale pure shear panel tests of SC members were reported, on which the “mechanics-based Membrane Model of SC elements (MM-SC)” is developed. The MM-SC model is based on the fixed-angle crack formulation and the smeared-crack formulation, in which the experimental-based uniaxial constitutive models are implemented, considering the local buckling of faceplate, the tension stiffening of steel plate, the strength degradation of cracked concrete and the confinement effect of concrete. The proposed MM-SC model is subsequently incorporated into the object-oriented software OpenSEES. Finally, the simulation results of proposed model well predict the SC test observations in terms of critical branch points and structural behaviors, including initial stiffness, cracking strength, post-crack stiffness, yield strength, maximum strength, and failure modes.

42 ENGINEERING↗

Towards the applications of mechanophore incorporated feedstocks for additive manufacturing

The ability to additively-manufacture mechanically responsive molecules, known as mechanophores (MPs), that are incorporated into polymer feedstocks provides opportunities for self-healing, real-time damage detection, and improvements in quality assurance and control capabilities to several industries (wind energy technology, building and construction, etc.) who are adopting additive manufacturing (AM). However, before the applications are realized and industrially adopted, further research and development regarding MP-incorporated AM feedstock availability, production scale-up, and processability and printability is needed. Here, the goal of this review is to bridge the gap between the bench top and real world applications of AM of MPs by identifying high impact application spaces and highlighting the challenges that need to be overcome for widespread adoption. The state-of-the-art of AM of MP-incorporated feedstocks is reviewed, followed by a discussion of potential future applications, current challenges, and research areas that work toward commercialization of AM of MP-incorporated feedstocks.

36 MATERIALS SCIENCE↗

Impact of transportation network companies on urban congestion: Evidence from large-scale trajectory data

We collect vehicle trajectory data from major transportation network companies (TNCs) in New York City (NYC) in 2017 and 2019, and we use the trajectory data to understand how the growth of TNCs has impacted traffic congestion and emission in urban areas. By mining the large-scale trajectory data and conduct the case study in NYC, we confirm that the rise of TNC is the major contributing factor that makes urban traffic congestion worse. From 2017 to 2019, the number of for-hire vehicles (FHV) has increased by over 48% and served 90% more daily trips. These resulted in an average citywide speed reduction of 22.5% on weekdays, and the average speed in Manhattan decreased from 11.76 km/h in April 2017 to 9.56 km/h in March 2019. The heavier traffic congestion may have led to 136% more NOx, 152% more CO and 157% more HC emission per kilometer traveled by the FHV sector. Our results show that the traffic condition is consistently worse across different times of the day and at different locations in NYC. And we build the connection between the number of available FHVs and the reduction in travel speed between the two years of data and explain how the rise of TNC may impact traffic congestion in terms of moving speed and congestion time. Our findings provide valuable insights for different stakeholders and decision-makers in framing regulation and operation policies towards more effective and sustainable urban mobility.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗